• 제목/요약/키워드: Diode/diode laser

검색결과 1,017건 처리시간 0.035초

저출력 레이저 치료기의 광 출력 특성 (Characteristics of Optical Power of Low Level Laser Apparatus)

  • 천민우;김성환;박용필;유성미;박노봉;이희갑
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.496-496
    • /
    • 2007
  • Low level laser has various therapy effects. This paper performed the basic study for fabricating the low level laser therapy apparatus, and one of the goals of this paper was to make this apparatus used handily. The apparatus has been fabricated using the laser diode and microprocessor unit. The apparatus used a 660nm Laser diode for blood stream improvement and was designed for a pulse width modulation type to increase stimulation effects. In result, we could get the light power of 660nm wavelength and the 1~10Hz irradiation frequency could be controlled stably.

  • PDF

CD-ROM 드라이브의 대물렌즈 입자오염이 Laser Diode의 Power와 Photo Diode의 RF Signal에 미치는 영향 (Effect of Particle Contamination on Objective Lens in a CD-ROM Drive on Laser Diode Power and Photo Diode RF Signal)

  • 배양일;황정호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1429-1434
    • /
    • 2003
  • A number of dust particles are intruded into ODD(Optical disk drive) due to the flow caused by disk rotation and are adhered to a lens or disk surface. The space between the disk and the lens is being reduced. Someone indicates the problems of this drive that are relatively small data storing capacity and slow access time. In recent, the problems of this optical disk drive mentioned above are being solved by adding the speed of the disk's revolution, making the actuator high-speed or light, and making the beam spot size smaller than making the space narrow between disk and lens. These particle contamination affects seriously RF Signal, readout signal in an ODD. Especially, the affected parts by a particle contamination in an ODD's readout signal are objective lens and media.

  • PDF

High-brightness Phosphor-conversion White Light Source Using InGaN Blue Laser Diode

  • Ryu, Han-Youl;Kim, Dae-Hwan
    • Journal of the Optical Society of Korea
    • /
    • 제14권4호
    • /
    • pp.415-419
    • /
    • 2010
  • A phosphor-conversion white light source is demonstrated using an InGaN-based blue laser diode (LD) and a yellow-emitting phosphor excited by the blue LD. The photometric and colorimetric properties of this blue-LD-based white light source are characterized. When injection current of the LD is 100 mA, luminous flux and luminous efficiency of the white light are found to be over 5 lm and 10 lm/W, respectively. When injection current is >90 mA, luminance is estimated to be larger than 10 Mcd/$cm^2$. In addition, color characteristics of the white light such as chromaticity coordinates, a correlated color temperature, and a color rendering index are found to be quite stable as current and temperature of the LD varies. The demonstrated LD-based white light source is expected to be used in high-brightness illumination applications with good color stability.

655nm 레이저 다이오드 조사에 따른 생물학적 특성 평가 (The biomedical effect of 655nm Laser Diode irradiation)

  • 천민우;김성환;박용필;이호식;김태곤;박노봉
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 추계학술대회 논문집 Vol.21
    • /
    • pp.397-398
    • /
    • 2008
  • This paper performed the basic study for fabricating the low level laser therapy apparatus, and one of the goals of this paper was to make this apparatus used handily. The apparatus has been fabricated using the 655nm laser diode and microprocessor unit. The apparatus used a 655 nm laser diode for laser medical therapy and was designed for a pulse width modulation type to increase stimulation effects. And then, each experiment was performed to irradiation group and non-irradiation group for cells. MTT assay method was chosen to verify the cell increase of two groups and the effect of irradiation on cell proliferation was examined by measuring 590nm transmittance of ELISA reader. As a result, the cell increase of cells was verified in irradiation group as compared to non-irradiation group.

  • PDF

레이저 절단에서 광소자를 이용한 가공공정 모니터링 (Process Monitoring in Laser Beam Cutting by Photo Diode)

  • 장욱진;김봉채;김재도
    • 한국정밀공학회지
    • /
    • 제13권12호
    • /
    • pp.30-37
    • /
    • 1996
  • On-line process control equipment for CO$_{2}$ laser cutting is not available for industrial applications. The major part of the industrial laser cutting machines are adjusted off-line by highly educated engineers. The quality inspection of the sample is visual and referred to different quality scales. Due to the lack of automation the potential laser users hesitate to implement the cutting method. The first step toward an automation of the process is the development of a process monitoring system and the research is cincentrated on the area of on-line quality monitoring during CO$_{2}$ laser cutting. The method is based on the detection of the emitted light from the cutting front by photo diode. The developed monitoring system consists of the OP Amplifier, A/D convertor, power supply and PC. The signal from the photo diode has been undertaken from Fourier analysis and statistical analysis with real time. The photograph of striation pattern was taken by metallurgical microscope. As a result, it is possible to predict the striation pattern according to the beam traveling speed.

  • PDF

Treatment of Oral Leukoplakia with Diode Laser: a Pilot Study on Indian Subjects

  • Kharadi, Usama A Rashid;Onkar, Sanjeev;Birangane, Rajendra;Chaudhari, Swapnali;Kulkarni, Abhay;Chaudhari, Rohan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권18호
    • /
    • pp.8383-8386
    • /
    • 2016
  • Background: To evaluate the safety, convenience and effectiveness of 940nm diode laser for treatment of homogenous leukoplakia. Materials and Methods: Ten patients having homogenous leukoplakia which were diagnosed clinically were selected from an Indian dental educational institution for the study. Toludine blue staining was applied locally over the lesion. The area where there was increased uptake of stain was excised using a 940 nm EZLASE TM diode laser (BIOLASE-USA). Results: Although various treatment modalities have been tried and the search continues for novel treatment modalities for complete removal of homogenous leukoplakia, from results of our preliminary pilot study it is clear that the use of 940 nm diode laser as a treatment modality for homogenous leukoplakia is a good substitute. Healing was perfect without any complication within a duration of 1 month. Pain intensity was also mild and absolutely zero on the VAS scale after 1 month follow up. Conclusions: 940 nm diode lasers are safe and can be effectively used as a treatment modality of homogenous leukoplakia, without any complication and without compromising health and oral function of patients. Considering recurrence factor, long term follow up for patients is a must.

Outcome of 980 nm diode laser vaporization for benign prostatic hyperplasia: A prospective study

  • Mithani, M. Hammad;El Khalid, Salman;Khan, Shariq Anis;Sharif, Imran;Awan, Adnan Siddiq;Mithani, Shoaib;Majeed, Irfan
    • Investigative and Clinical Urology
    • /
    • 제59권6호
    • /
    • pp.392-398
    • /
    • 2018
  • Purpose: To evaluate the initial experience and outcome of photo-selective vaporization of the prostate (PVP) for benign prostatic hyperplasia (BPH) in Pakistan with the use of a 980 nm diode laser. Materials and Methods: A prospective study was performed from November 2016 to December 2017. A total of 100 patients diagnosed with bladder outlet obstruction secondary to BPH who planned for PVP were enrolled in the study. PVP was carried out with a diode laser at 980 nm (Biolitec Diode 180W laser) in a continuous wave with a 600 nm (twister) fiber. Baseline characteristics and perioperative data were compared. Postoperative outcomes were evaluated by International Prostate Symptom Score (IPSS), post void residual (PVR) and maximum urinary flow rate (Qmax) at 3 and 6 months after surgery. Results: The mean age was $65.82{\pm}10.42$, mean prostate size was $67.35{\pm}16.42$, operative time was $55.85{\pm}18.01$ and total energy was $198.68{\pm}49.12kJ$. At 3 months and 6 months, significant improvements were noted (p<0.001) in IPSS $7.04{\pm}1.69$ (-18.92), Qmax $19.22{\pm}4.75mL/s$ (+13.09) and and PVR $18.89{\pm}5.39mL$ (-112.80). Most frequent problems were burning micturition (35%) and terminal dysuria (29%). No significant difference in postoperative hemoglobin was seen in patients who were on anti-platelet drugs. Conclusions: PVP with a diode laser is a safe and effective procedure for the treatment of BPH and is also safe in patients who are on anti-platelet agents.

The Laser Range Finder for the Mobile Robot Navigation using a Lock-in Amplifier

  • Yoon, Hee-Sun;Shin, Myung-Kwan;Park, Kyi-Hwan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1423-1426
    • /
    • 2005
  • Map building is the most important thing for the mobile robots navigation. It requires specific vision system such as CCD camera, range finding system, and many other things. Laser range finder has highly collimated beams can be obtained easily, thus achieving lateral resolution. Laser Diode is used for a continuous laser source. The Automatic Current Control Circuit and the Bias-T is used for mix AC signal with DC bias. This signal is used for driving Laser Diode. The main idea of the calculating distance is detecting phase shift between reference signal and detected signal by photo detector. For the signal processing, the Lock-in amplifier system is addressed in this paper. We used a diffused reflected beam to detect phase shift in this system. But this beam is minuteness signal so it can be easily buried in nose. Lock-in amplifier is used to measure the amplitude and phase of signals which are buried in noise.

  • PDF

난반사체를 이용한 다이오드 횡여기 Nd:YAG 레이저의 최적화 설계 및 분석 (Optimum design and analysis of a diode side-primped Nd:YAG laser with a diffusive reflector)

  • 이성만;윤미정;김선국;김현수;차병헌;문희종
    • 한국광학회지
    • /
    • 제12권6호
    • /
    • pp.489-495
    • /
    • 2001
  • 난반사체를 이용한 다이오드 횡여기 Nd:YAG 레이저 헤드의 설계코드를 개발하여 레이저 결정 내 홉수된 빔의 균일성과 최대 레이저 출력을 갖는 설계요소의 조건에 관해 분석하고, 수치해석 방법으로 열렌즈 효과를 고려한 레이저 공진기의 레이저 출력을 계산하고 실험치와 비교 분석하였다. 1,080W의 여기광 출력에서 측정된 약 504 W의 레이저 출력은 열렌즈 효과를 고려하여 수치 해석적으로 계산된 레이저 출력과 레이저 공진기의 안정영역에서 거의 일치함을 확인하였다.

  • PDF

Treating Oral Leukoplakia with a 532-nm Pulsed Diode Laser

  • Im, Nu-Ri;Kim, Byoungjae;Kim, Jian;Baek, Seung-Kuk
    • Medical Lasers
    • /
    • 제8권1호
    • /
    • pp.39-42
    • /
    • 2019
  • A 50-year-old Korean female with oral erythro-leukoplakia was treated using a 532-nm Diode laser at 6 Watts with a pulsed width of 25 milliseconds. After two months following the laser treatment, the resected region was well-healed without any significant scar contracture. We suggest that the use of the 532-nm Diode laser can be a safe and effective treatment modality for patients suffering from oral leukoplakia.