• 제목/요약/키워드: Dimensional stabilizer

검색결과 22건 처리시간 0.019초

ANALYSES ON FLOW FIELDS AND PERFORMANCE OF A CROSS-FLOW FAN WITH VARIOUS SETTING ANGLES OF A STABILIZER

  • Kim D. W.;Kim H. S.;Park S. K.;Kim Youn J
    • 한국전산유체공학회지
    • /
    • 제10권1호
    • /
    • pp.107-112
    • /
    • 2005
  • A cross-flow fan is generally used on the region within the low static pressure difference and the high flow rate. It relatively makes high dynamic pressure at low rotating speed because a working fluid passes through an impeller blade twice and blades have a forward curved shape. At off-design points, there are a rapid pressure head reduction, a noise increase and an unsteady flow. Those phenomena are remarkably influenced by the setting angle of a stabilizer. Therefore, it should be considered how the setting angle of a stabilizer affects on the performance and the flow fields of a cross-flow fan. It is also required to investigate the effect of the volumetric flow rate before occurring stall. Two-dimensional, unsteady governing equations are solved using a commercial code, STAR-CD, which uses FVM. PISO algorithm, sliding grid system and standard k - ε turbulence model are also adopted. Pressure and velocity profiles with various setting angles are graphically depicted. Furthermore, the meridional velocity profiles around the impeller are plotted with different flow rates for a given rotating speed.

최소모델영역 연산자를 모델제한조건으로 적용한 2차원 MT 역산 (An Application of Minimum Support Stabilizer as a Model Constraint in Magnetotelluric 2D Inversion)

  • 이성곤
    • 한국지구과학회지
    • /
    • 제30권7호
    • /
    • pp.834-844
    • /
    • 2009
  • 본 연구에서는 최소모델영역 연산자를 MT(magnetotelluric) 2차원 역산 알고리듬에 적용하여 역산 해의 대비를 향상시키고자 하였다. 이를 위하여 creeping법에 기초한 최소자승 역산에 최소모델영역 연산자를 수치적으로 유도하여 알고리듬을 구현하였으며, 공간함수로서의 평활화 상수를 도입한 ACB (Active Constraint Balancing) 법을 동시에 적용하여 최소모델영역 연산자를 이용할 때 단점으로 지적되었던 역산 해의 안정성을 향상시켰다. 고립된 단일 이상체 모델에 대한 수치실험을 통하여 MT 역산에 있어서 최소영역 연산자의 효과를 기존의 2차 미분연산자와 비교 분석하여 MT 역산에서의 특징을 고찰하였다. 또한 다중 이상체 모델에 대한 실험을 통하여 Occam 역산과 비교하여 최소모델영역 연산자를 이용한 역산 해의 특징을 비교 분석하였으며 현장 자료에의 적용을 통하여 그 적용성을 살펴보았다.

증기발생기 전열관에 작용되는 정적 하중 평가 (Estimation of Static Load Applied on Steam Generator Tubes)

  • 박범진;박재학;조영기
    • 한국압력기기공학회 논문집
    • /
    • 제7권1호
    • /
    • pp.35-40
    • /
    • 2011
  • If a plugged tube in a steam generator is broken, it may damage nearby intact tubes. To prevent this damage, it is recommended that a stabilizer is installed into the plugged tube. However, the installation cost of a stabilizer is very high. So studies are required to determine the conditions on which the installation is necessary. For this purpose static loads and dynamic loads applied on a tube should be known to estimate the residual strength and remaining fatigue and wear life of a plugged tube. Two-dimensional and three-dimensional computational fluid dynamics (CFD) analyses are performed to obtain the drag coefficient for cross flow to a tube. Using the obtained drag coefficient, the static load can be estimated and the residual strength of a plugged tube can be calculated. An inclined flow problem is also analyzed and the vertical and horizontal forces are obtained and discussed.

스태빌라이져 위치 및 리어가이더 형상변화에 따른 횡류홴의 성능특성 연구 (Performance of a Cross-Flow Fan with Various Stabilizer Positions and Rearguider Shapes)

  • 김동원;김형섭;윤태석;박성관;김윤제
    • 한국유체기계학회 논문집
    • /
    • 제7권4호
    • /
    • pp.7-15
    • /
    • 2004
  • The design point of the cross-flow fan is generally based on the region within low static pressure and high flow rate. It relatively makes high dynamic pressure at low speed because a working fluid passes through an impeller blade twice. However, it has low static pressure efficiency between $30\%$ and $40\%$ because of relative high impact loss. The purpose of this study is to research the reciprocal relation among each parameter. Experiments and numerical analyses are conducted on effects of a stabilizer and a rearguider on performance analysis of a cross-flow fan. Two-dimensional, unsteady governing equations are solved using FVM, PISO algorithm, sliding grid system and standard $k-{\epsilon}$ turbulence model. Experiments are also carried out to estimate the performance of the modeled cross-flow fan. It is clarified that the rearguider of Archimedes type has excellent results for the most part.

버터플라이 밸브 하류 유동의 안정화에 관한 연구 (An Experimental Study on the Flow Stabilization in the Downstream Region of a Butterfly-Type Valve)

  • 박상원;이상우
    • 대한기계학회논문집B
    • /
    • 제24권11호
    • /
    • pp.1417-1427
    • /
    • 2000
  • A flow stabilizer, which is made of a honeycomb and three different mesh screens, is located downstream of a butterfly-type valve, for the reduction of flow disturbances behind the valve. Mean flow and turbulence measurements as well as flow visualizations are conducted in the downstream region of the deepens the non-uniformity of the streamwise velocity component and turbulence. The mesh screens considerably reduce the turbulence and enhance the uniformity of mean velocities. The combination of the honeycomb and the three mesh screens results in an efficient reduction in the flow disturbances. In addition, the flow stabilizer proves to have a good performance in the suppression of turbulence at a short distance.

횡류팬의 최적설계방안 (Optimum Design of a Cross Flow Fan)

  • 김동훈;박형구
    • 한국전산유체공학회지
    • /
    • 제8권4호
    • /
    • pp.50-57
    • /
    • 2003
  • Cross-flow fans are widely used in various applications, due to their large capacity of mass flow and size compactness. The flow field of the cross-flow fan is, however, complex and has many design parameters. Thus, the general design guide has not been sufficiently established yet and the design strategies of cross-flow fans have been mostly based on experiments. In the present study, the performance and their two-dimensional flow characteristics are numerically analyzed by using the STAR-CD(commercial computational fluid dynamics code). The simulation is done by varying the several design parameters such as the impeller blade shapes and the gap between the stabilizer and impeller. The computational results are compared with the experimental data at the fan outlet region. Finally, some helpful guides for the optimum design of cross-flow fans are proposed.

Optimum Design of a Cross Flow Fan

  • Kim Dong-Hoon;Park Hyung-Koo
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2003년도 The Fifth Asian Computational Fluid Dynamics Conference
    • /
    • pp.260-262
    • /
    • 2003
  • Cross-flow fans are widely used in various applications, due to their large capacity of mass flow and size compactness. The flow field of the cross-flow fan is, however, complex and has many design parameters. Thus, the general design guide has not been sufficiently established yet and the design strategies of cross-flow fans have been based on experiments. In the present study, the performance and their two-dimensional flow characteristics are numerically analyzed by using the STAR-CD(commercial computational fluid dynamics code). The simulation is done by varying the several design parameters such as the impeller blade shapes and the gap between the stabilizer and impeller. The computational results are compared with the experimental data at the fan outlet region. Finally some helpful guides for the optimum design of cross-flow fans are proposed.

  • PDF

횡류팬의 최적설계방안 (Optimum Design of a Cross Flow Fan)

  • 김동훈;박형구
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2003년도 추계 학술대회논문집
    • /
    • pp.176-181
    • /
    • 2003
  • The cross-flow fans are widely used in various applications, due to their large capacity of mass flow and the size compactness. The flow fields of the cross-flow fan is, however, complex and it has many design parameters. Thus the general design guide has not sufficiently established yet, and the design strategies of cross-flow fans have been based on experiments. In the present study, the cross-flow fan performance and its two-dimensional flow characteristics are numerically analyzed by using the STAR-CD. The simulation is done by varying the several design parameters such as impeller blade shapes, the gap between the stabilizer and impeller. The computational results are compared with the experimental data at the fan outlet region. Finally some helpful guides for the optimum design of the cross-flow fan are proposed.

  • PDF

리어가이더 시작각 변화가 횡류홴 성능에 미치는 영향 (Effects of Starting Angles of a Rearguider on the Performance of a Cross-Flow Fan)

  • 김형섭;김동원;윤태석;박성관;김윤제
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1981-1986
    • /
    • 2004
  • A cross-flow fan relatively makes high dynamic pressure at low speed because a working fluid passes through an impeller blade twice and blades have a forward curved shape. Therefore, the performance of a cross-flow fan is influenced 25% by the impeller, 60% by the rearguider and the stabilizer, 15% by the heat exchanger. At the low flow rate, there exists a rapid pressure head reduction, a noise increase and an unsteady flow against a stabilizer and a rearguider. Moreover, it is difficult to analyze the reciprocal relations of the cross-flow fan because each parameter is independent. Numerical analyses are conducted with different starting angles of the rearguider. Two-dimensional, unsteady governing equations are solved, using FVM, PISO algorithm, sliding grid system and ${\kappa}-{\varepsilon}$ standard turbulence model.

  • PDF

LES에 의한 RAC 실내기의 유동장 개선에 관한 전산유동해석 (Computational Flow Analysis on the Flow Field Improvement of an Indoor RAC by LES)

  • 김장권;오석형
    • 동력기계공학회지
    • /
    • 제16권3호
    • /
    • pp.29-36
    • /
    • 2012
  • The computational flow analysis using LES technique was introduced to investigate the flow field improvement of an indoor RAC chassis consisting of a rear-guider, a stabilizer and a cross-flow fan. This unsteady three-dimensional numerical analysis was carried out by the commercial SC/Tetra software. The edge blocks were adopted in this study as a tool for the flow field improvement of an indoor RAC. In view of the results so far achieved, the edge blocks cause the center of an eccentric vortex to be stable along all length of a cross-flow fan, and then, the static pressure and the velocity vector show a stable distributions. In consequence, because the edge blocks eliminate a reverse flow near the edges, an exhausting flow becomes to be stable and uniform.