• 제목/요약/키워드: Dimensional measurement accuracy

검색결과 353건 처리시간 0.034초

반무한보의 진동 인텐시티 계측에 대한 연구 (A Study on Structural Intensity Measurement of Semi-infinite Beam)

  • 이덕영;박성태
    • 소음진동
    • /
    • 제7권1호
    • /
    • pp.43-53
    • /
    • 1997
  • This paper investigated the practical use for measuring the structural intensity (power flow per width of cross section) in a uniform semi-infinite beam in flexural vibration. The structural intensity is obtained as a vector at a measurement point, One-dimensional structural intensity can be obtained from 4-point cross spectral measurement, or 2-point measurement on the assumption of far field. The measurement errors due to finite difference approximation and phase mismatch of accelerometers are examined. For precise measurements, it would be better to make the value of k$\delta$(wave number x space between accelerometers) between 0.5 and 1.0. Formulation of the relation between bending waves in structures and structural intensity makes it possible to separate the wave components by which one can get a state of the vibration field. Experimental results are obtained from 2- and 4-point measurement performed at 200mm (near field) and 400mm (far field) apart from excitation point in random excitation. the results are compared with the theoretical values and measured values of input power spectrum in order to verify the accuracy of structural intensity method, 2-point method is suggested as the practical structural intensity method.

  • PDF

Accuracy of three-dimensional cephalograms generated using a biplanar imaging system

  • Park, Ha-Yeon;Lee, Jae-Seo;Cho, Jin-Hyoung;Hwang, Hyeon-Shik;Lee, Kyung-Min
    • 대한치과교정학회지
    • /
    • 제48권5호
    • /
    • pp.292-303
    • /
    • 2018
  • Objective: Biplanar imaging systems allow for simultaneous acquisition of lateral and frontal cephalograms. The purpose of this study was to compare measurements recorded on three-dimensional (3D) cephalograms constructed from two-dimensional conventional radiographs and biplanar radiographs generated using a new biplanar imaging system with those recorded on cone-beam computed tomography (CBCT)-generated cephalograms in order to evaluate the accuracy of the 3D cephalograms generated using the biplanar imaging system. Methods: Three sets of lateral and frontal radiographs of 15 human dry skulls with prominent facial asymmetry were obtained using conventional radiography, the biplanar imaging system, and CBCT. To minimize errors in the construction of 3D cephalograms, fiducial markers were attached to anatomical landmarks prior to the acquisition of radiographs. Using the 3D $Ceph^{TM}$ program, 3D cephalograms were constructed from the images obtained using the biplanar imaging system (3D $ceph_{biplanar}$), conventional radiography (3D $ceph_{conv}$), and CBCT (3D $ceph_{cbct}$). A total of 34 measurements were obtained compared among the three image sets using paired t-tests and Bland-Altman plotting. Results: There were no statistically significant differences between the 3D $ceph_{biplanar}$ and 3D $ceph_{cbct}$ measurements. In addition, with the exception of one measurement, there were no significant differences between the 3D $ceph_{cbct}$ and 3D $ceph_{conv}$ measurements. However, the values obtained from 3D $ceph_{conv}$ showed larger deviations than those obtained from 3D $ceph_{biplanar}$. Conclusions: The results of this study suggest that the new biplanar imaging system enables the construction of accurate 3D cephalograms and could be a useful alternative to conventional radiography.

Clinical Validity of Tooth Size Measurements Obtained via Digital Methods with Intraoral Scanning

  • Mohammed, Alnefaie;Sun-Hyung, Park;Jung-Yul, Cha;Sung-Hwan, Choi
    • Journal of Korean Dental Science
    • /
    • 제15권2호
    • /
    • pp.132-140
    • /
    • 2022
  • Purpose: Dental diagnostic records derived from study models are a popular method of obtaining reliable and vital information. Conventional plaster models are the most common method, however, they are being gradually replaced by digital impressions as technology advances. Moreover, three-dimensional dental models are becoming increasingly common in dental offices, and various methods are available for obtaining them. This study aimed to evaluate the accuracy of the measurement of dental digital models by comparing them with conventional plaster and to determine their clinical validity. Materials and Methods: The study was conducted on 16 patients' maxillary and mandibular dental models. Tooth size (TS), intercanine width (ICW), intermolar width (IMW), and Bolton analysis were taken by using a digital caliper on a plaster model obtained from each patient, while intraoral scans were manually measured using two digital analysis software. A one-way analysis of variance test was used to compare the dental measurements of the three methods. Result: No significant differences were reported between the TS, the ICW and IMW, and the Bolton analysis through the conventional and two digital groups. Conclusion: Measurements of TS, arch width, and Bolton analysis produced from digital models have shown acceptable clinical validity. No significant differences were observed between the three dental measurement techniques.

박판성형 변형률 측정 오차보정에 관한 연구 (Study on the Error Compensation in Strain Measurement of Sheet Metal Forming)

  • 한병엽;차지혜;금영탁
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2003년도 춘계학술대회논문집
    • /
    • pp.270-273
    • /
    • 2003
  • The strain measurement of the panel in the sheet metal forming is essential work which provides experimental data needed to die design, process design, and product inspection. To measure efficiently the complex geometry strain, the 3-dimensional automative strain measurement system, which has high accuracy in theory, but has some 3∼5% errors in practice, is often used. The object of this study is to develop the error compensation technology to eliminate the strain, errors resulted when formed panels are measured using an automated strain measurement system. To achieve the study object, the position error calibration method correcting coordinates of the grid node recognized by a camera using error functions is suggested. Then the position errors were found by calculating the difference in the position of the cube node between real coordinates and measured coordinates in toms of node coordinates and the error calibration equations were derived by regressing the position errors. In order to show the validation of the suggested position error calibration method, finite element analysis and current calibration method was performed for the initial-blankformed.

  • PDF

위상이동 그림자 무아레방법을 이용한 형상측정법의 정확도 개선에 관한 연구 (A Study on the Improvement of Accuracy of Surface Measurement in the Phase-Shifting Shadow Moir$\'{e}$ Method)

  • 강영준;유원재;권용기
    • 한국정밀공학회지
    • /
    • 제15권10호
    • /
    • pp.96-102
    • /
    • 1998
  • In this study, the theory and application of phase-shifting shadow moire topography is focused on the non-contact measurement of object surfaces for practical use in the field of production engineering. Shadow moire topography has been studied during last few decades in the area of the optical physics, and now its mathmatical theory has been established. Generally, in case of the classical shadow moire topography, the sensitivity is a few tenths of millimeter in best cases. Here we tried the application of phase-shifting method to the conventional shadow moire topography. But the reference grating and the deformed grating are mutually dependent because it is impossible to obtain uniform phase shifts on the whole Held. Therefore it is difficult to use a phase-shifting method in shadow moire topography. However, it was shown that constant phase-shifting was able to be measured by moving both the grating and light source. Finally we obtained a better result by using this procedure and applied the phase-shifting shadow moire to three dimensional object measurement.

  • PDF

유방에 대한 길이 파라미터를 이용한 3차원 유방 부피의 예측 개선 (Accuracy Improvement of Breast Volume Estimation Using Length Parameters of Breast)

  • 이현영;홍경희
    • 복식문화연구
    • /
    • 제14권5호
    • /
    • pp.840-849
    • /
    • 2006
  • Breast volume has been approximately estimated under the assumption that the shape of breast is a corn. However, women's breast is more like a bulged bag in reality. In this paper, three methods of breast volume estimation were compared to find out the more accurate method. The shape of the breast is assumed as a hemisphere in the first estimation method and a corn in the second one. In the third method, arc along the cross sectional shape of breast was utilized in the calculation. Comparisons among the methods were made using the actual 3D volume measurement of thirty seven women's breast. As results, the third method was the best one for the normal breast type, especially for the lower part of the breast ($R^2=0.74$) which is the crucial design parameter of the brassiere. Assumption of the shape of breast as a corn was reasonably acceptable when the breast is sagged. It was expected that when women wore brassiere, the accuracy of the third method would increase more, since the shape of breast becomes more symmetrical.

  • PDF

Accuracy of virtual models in the assessment of maxillary defects

  • Kamburoglu, Kivanc;Kursun, Sebnem;Kilic, Cenk;Ozen, Tuncer
    • Imaging Science in Dentistry
    • /
    • 제45권1호
    • /
    • pp.23-29
    • /
    • 2015
  • Purpose: This study aimed to assess the reliability of measurements performed on three-dimensional (3D) virtual models of maxillary defects obtained using cone-beam computed tomography (CBCT) and 3D optical scanning. Materials and Methods: Mechanical cavities simulating maxillary defects were prepared on the hard palate of nine cadavers. Images were obtained using a CBCT unit at three different fields-of-views (FOVs) and voxel sizes: 1) $60{\times}60mm$ FOV, $0.125mm^3$ ($FOV_{60}$); 2) $80{\times}80mm$ FOV, $0.160mm^3$ ($FOV_{80}$); and 3) $100{\times}100mm$ FOV, $0.250mm^3$ ($FOV_{100}$). Superimposition of the images was performed using software called VRMesh Design. Automated volume measurements were conducted, and differences between surfaces were demonstrated. Silicon impressions obtained from the defects were also scanned with a 3D optical scanner. Virtual models obtained using VRMesh Design were compared with impressions obtained by scanning silicon models. Gold standard volumes of the impression models were then compared with CBCT and 3D scanner measurements. Further, the general linear model was used, and the significance was set to p=0.05. Results: A comparison of the results obtained by the observers and methods revealed the p values to be smaller than 0.05, suggesting that the measurement variations were caused by both methods and observers along with the different cadaver specimens used. Further, the 3D scanner measurements were closer to the gold standard measurements when compared to the CBCT measurements. Conclusion: In the assessment of artificially created maxillary defects, the 3D scanner measurements were more accurate than the CBCT measurements.

라이다 데이터와 항공 정사영상을 활용한 인공 제방선 지도화 (Mapping Man-Made Levee Line Using LiDAR Data and Aerial Orthoimage)

  • 정윤재;박현철;정연인;조명희
    • 한국지리정보학회지
    • /
    • 제14권1호
    • /
    • pp.84-93
    • /
    • 2011
  • 제방선 지도화는 하천지역의 환경보호와 하천 범람 방지, 그리고 하천 개발에 있어 매우 중요하다. 라이다(LiDAR)와 항공 정사영상(aerial ortho-image)과 같은 원격탐사 데이터의 활용은 대상 지역에 접근하지 않고도 대상 지역에 관한 지형 정보를 얻을 수 있다는 점 때문에, 하천 지도화 작업에 효율적이다. 라이다 자료는 얕은 물을 관통하는 능력과 높은 수직 정확도 때문에 하천구역 지도화 작업에 활용되어 오고 있다. 영상자료의 활용 또한 영상처리 기법을 이용하여 여러 특징들을 추출할 수 있다는 점 때문에 하천 지도화 작업에 효율적이다. 본 논문에서는 라이다와 항공 정사영상을 각각 활용하여 3차원 제방선 지도화 작업을 수행하였다. 그리고 지상 실측정보들을 통해 두 자료로부터 추출된 제방선들의 정확도를 측정하고, 두 측정 결과들을 비교한다. 통계적인 결과에서 나타나듯이 라이다를 활용하여 추출된 3차원 제방선이 항공 정사영상을 활용하여 추출된 3차원 제방선에 비해 수평 및 수직 정확도가 훨씬 더 높다는 것을 보여준다.

역복사 해석을 위한 혼합형 유전 알고리듬에 관한 연구 (A Study on a Hybrid Genetic Algorithm for the Analysis of Inverse Radiation)

  • 김기완;백승욱;김만영;유홍선
    • 대한기계학회논문집B
    • /
    • 제27권10호
    • /
    • pp.1516-1523
    • /
    • 2003
  • An inverse radiation analysis is presented for the estimation of the boundary emissivities for an absorbing, emitting, and scattering media with diffusely emitting and reflecting opaque boundaries. The finite-volume method is employed to solve the radiative transfer equation for a two-dimensional irregular geometry. A hybrid genetic algorithm is proposed for improving the efficiency of the genetic algorithm and reducing the effects of genetic parameters on the performance of the genetic algorithm. After verifying the performance of the proposed hybrid genetic algorithm, it is applied to inverse radiation analysis in estimating the wall emissivities in a two-dimensional irregular medium when the measured temperatures are given at only four data positions. The effect of measurement errors on the estimation accuracy is examined.

Application of 3-D Scanner to Analysis of Functional Instability of the Ankle

  • Han, Cheng-Chun;Kubo, Masakazu;Matsusaka, Nobuou;Ishimatsu, Takakazu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1971-1975
    • /
    • 2003
  • This paper describes a technique, which analyzes the functional instability of the ankle using three-dimensional scanner. The technique is based on the structured light pattern projection method, which is performed by using one digital still camera and one LCD projector. This system can be easily realized with the low cost. The measuring result has high accuracy. The measuring error is about 0.2 mm or less. Using this technique the three-dimensional posture of the leg and foot of the target person are measured and analyzed.

  • PDF