• 제목/요약/키워드: Dimensional measurement accuracy

검색결과 344건 처리시간 0.031초

시각측정시스템의 캘리브레이션 및 측정성능 검토 (Calibration and INvestigation into Measurement Performance of a Visual Sensing System)

  • 김진영;조형석
    • 한국정밀공학회지
    • /
    • 제16권8호
    • /
    • pp.113-121
    • /
    • 1999
  • It is necessary to calibrate measurement systems to enhance its measurement accuracy. The visual sensing system that is presented in our previous work has to be calibrated, too. It is a multiple mirror system for three-dimensional measurement, which is composed of a camera and a series of mirrors. It is important to calibrate the positions and orientations of the mirrors relative to the camera because they have direct influence on the relationship between the image plane and the task space. This paper presents the calibration method for the visual sensing system. To confirm the measurement performance of the implemented system. its measurement accuracy in measuring the locations in three-dimensional space is investigated. A series of experiments for measuring the locations of the circle-shaped marks are performed. Experimental results show that the sensing system can be effectively used for three-dimensional measurement.

  • PDF

2차원 프로브에 의한 NC공작기계의 운동 정밀도 측정 -제2보 직선운동 정밀도 측정- (Measurement of Motion Accuracy by Two-dimensional Probe on NC Machine Tools -2nd Report, Measurement of the Linear Motion Accuracy-)

  • 전언찬;소산전중덕;제정신;각전윤일랑
    • 한국정밀공학회지
    • /
    • 제14권7호
    • /
    • pp.15-21
    • /
    • 1997
  • This paper presented a linear motion accuracy by using two-dimensional probe with the master block and the square for NC machine tools. This measuring system could be measured motion error due to numerical control system. The results of measurement and simulation for motion error were similar, and so, this system had enough accuracy to measure a linear motion accuracy for NC machine tools. The experimental results are as follows. 1. This measuring system could be measured motion error due to mumerical control system. 2. The results of measurement and simulation for motion error were similar. 3. This measuring system had enough accuracy to measure a linear motion accuracy for NC machine tools.

  • PDF

비젼프로브를 가지는 3차원 측정기를 위한 형상 측정 시스템 묘듈 개발 (Vision Inspection Module for Dimensional Measurement in CMM having Vision Probe)

  • 이일환;박희재;김구영
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 추계학술대회 논문집
    • /
    • pp.379-383
    • /
    • 1995
  • In this paper, vision inspection module for dimensional measurement has been developed. For high accuracy of CMM, camera calibration and edge detection with subpixel accuracy have been implemented. In measurement process, the position of vision probe can be recognized in PC by serial communication with CMM controller. The developed vision inspection module can be widely applied to the practical measurement process.

  • PDF

기상측정(機上測定) 시스템 개발 (Development of On-the-Machine Measurement(OMM) System)

  • 이승우;김선호
    • 산업공학
    • /
    • 제11권1호
    • /
    • pp.199-205
    • /
    • 1998
  • This paper describes the development of on-the-machine measuring(OMM) system which can directly measure the two and three dimensional machined accuracy using a scanning probe in milling machine. Two algorithms, NC program based continuous path(CP) measurement and CAD data assisted point to point(PTP) measurement, are developed for three dimensional measurements, with consideration of the characteristics of the scanning probe. The algorithms are used to develop an auto measuring system. The delveloped system is compared with the CMM (Coordinate Measuring Machine) in terms of accuracy and repeatability. The OMM system is expected to realize measurement time reduction and hence result in high productivity.

  • PDF

Stereoscopic micro-PTV기법의 개발 (Development of Stereoscopic Micro-PTV Method)

  • 유청환;김형범
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2007년도 추계학술대회
    • /
    • pp.109-113
    • /
    • 2007
  • Micro-PIV is a well-known method for measurement of two- dimensional, two-component velocity in the microfluidic devices. Lots of the micro fluidic devices generate three-dimensional flow and 3D measurement of velocity is helpful to understand the physics of micro flow phenomena. In this study, we developed new micro 3D measurement method by applying 2-frame PTV in stereoscopic micro system. In this study, we did the validation study of SMPTV by using the simulated flow model to verify the accuracy and the feasibility of measurement and compared with SMPIV method. The results showed that SMPTV provides better spatial resolution and measurement accuracy than SMPIV method.

  • PDF

디지털 치과모형의 정확도 평가 방법에 대한 고찰 (A review on the accuracy assessment methods of 3-dimensional digital dental models)

  • 박지수;임영준;이정원;김봉주
    • 구강회복응용과학지
    • /
    • 제35권2호
    • /
    • pp.55-63
    • /
    • 2019
  • 본 논문은 기존에 선행되었던 연구들을 바탕으로 디지털 모형의 정확도를 평가하는 여러 가지 방법에 관하여 정리하였다. 디지털 모형의 정확도 평가 시, 시험자 교육과 인공적 지표의 사용을 통해 오차를 줄일 수 있다. 디지털 치아 모형의 정확도 평가법은 크게 선형 측정법, 2차원 단면 분석법, 3차원 최적합 분석법으로 분류할 수 있다. 스캐너의 기술이 발전함에 따라 디지털 인상 기술과 전통적 인상법의 정확도를 비교하는 많은 연구들이 이루어지고 있다. 다양한 방법을 이용하여 디지털 모형의 정확도를 평가할 수 있으며, 앞으로 스캐너의 기술 향상 및 3차원 모형 분석 소프트웨어의 개발에 따라 디지털 모형의 정확도 평가 방법이 더욱 효과적으로 변화할 것이라 생각된다. 이 논문에서는 디지털 모형의 정확도를 평가하는 방법들에 대해 소개하고, 각각의 상황에 따른 효과적인 정확도 분석법에 대해 알아보고자 한다.

Precision Evaluation of Three-dimensional Feature Points Measurement by Binocular Vision

  • Xu, Guan;Li, Xiaotao;Su, Jian;Pan, Hongda;Tian, Guangdong
    • Journal of the Optical Society of Korea
    • /
    • 제15권1호
    • /
    • pp.30-37
    • /
    • 2011
  • Binocular-pair images obtained from two cameras can be used to calculate the three-dimensional (3D) world coordinate of a feature point. However, to apply this method, measurement accuracy of binocular vision depends on some structure factors. This paper presents an experimental study of measurement distance, baseline distance, and baseline direction. Their effects on camera reconstruction accuracy are investigated. The testing set for the binocular model consists of a series of feature points in stereo-pair images and corresponding 3D world coordinates. This paper discusses a method to increase the baseline distance of two cameras for enhancing the accuracy of a binocular vision system. Moreover, there is an inflexion point of the value and distribution of measurement errors when the baseline distance is increased. The accuracy benefit from increasing the baseline distance is not obvious, since the baseline distance exceeds 1000 mm in this experiment. Furthermore, it is observed that the direction errors deduced from the set-up are lower when the main measurement direction is similar to the baseline direction.

정밀 좌표측정용 머신비전 시스템의 광학적 해석에 관한 연구 (A Study on the optical aspects of machine vision based dimensional measurement system)

  • Lee, E.H.
    • 한국정밀공학회지
    • /
    • 제11권2호
    • /
    • pp.149-163
    • /
    • 1994
  • A novel method of dimensional measurement using machine vision, which is called Landmark Tracking System, has been developed. Its advantages come form tracking only the bright, standard shaped "landmarks" which are made from retroreflective sheets. In the design of the LTS, it is essential to know the relationship between optical parameters and their influence on system performance. Such optical parameters include the brightness of landmark image, the illumination system design, and the choice of imaging optics. And the performance of retroreflective material also plays important role in the LTS performances. Influences of such optical parameters on LTS's dimensional measurement characteristics are investigated, with respect to the retroreflective material, the imaging optics, and the illumination system. Measuremtn errors due to parameter variations are also analyzed. Experiments are performed with a LTS prototype. Retroreflective characteristics are verified, and the LTS's measurement performances are measured in the form of repeatability and accuracy. Experimental results shgow that the LTS has repeatability better than 1/30,000 of a field of view(30 degrees), and accuracy better tha 1/3,000 of a field fo view.d fo view.

  • PDF

무선 센서를 활용한 요추 가동 범위의 실시간 3차원 측정 (Real-time 3-Dimensional Measurement of Lumbar Spine Range of Motion using a Wireless Sensor)

  • 정우혁;지혜미;박재현
    • 제어로봇시스템학회논문지
    • /
    • 제18권8호
    • /
    • pp.713-718
    • /
    • 2012
  • Lumber spine range of motion has been used to measure of physical and functional impairment by various tools from a ruler to 3D kinematic devices. However, pre-existing tools have problems in either movement or accuracy and reliability limitations. Accurate devices are limited by fixed space whereas simple devices are limited in measuring complex movements with less accuracy. In order to solve the location, movement and accuracy limitations at once, we have developed a novice measurement device equipped with accelerometer sensor and gyroscope sensor for getting three-dimensional information of motion. Furthermore, Kalman filter was applied to the algorithm to improve accuracy. In addition, RF wireless communication was added for the user to conveniently check measured data in real time. Finally, the measurement method was improved by considering the movement by a reference point. An experiment was conducted to test the accuracy and reliability of the device by conducting a test-retest reliability test. Further modification will be conducted to used the device in various joints range of motion in clinical settings in the future.

Draw-Wire센서를 이용한 파이프 플랜지 계측시스템 (Pipe Flange Measurement System Using Draw-Wire Sensor)

  • 윤재웅;윤강섭;이수철
    • 한국정밀공학회지
    • /
    • 제20권8호
    • /
    • pp.62-69
    • /
    • 2003
  • In most shipyards, the measurement of 3-dimensional relative position of pipes should be connected in the block depends on the manual operation. It results a very tedious and inefficient procedure, thus the proper measurement system is needed to improve productivity and accuracy. This paper describes the development of pipe measurement system including system concepts, measuring procedures, system calibration, and its accuracy and productivity. And also, the possibility and things to be improved for application in shipyard are discussed in this paper.