The Movable Hydraulic Model Test for Exchange of Intake Weir in the Nakdong River (낙동강 취수보개체를 위한 이동상 수리모형실험)

  • 김성원
    • Journal of Environmental Science International
    • /
    • v.9 no.1
    • /
    • pp.35-42
    • /
    • 2000
  • In this study, the movable bed model testing was carried out so as to analyze bed profile changes including predicting scouring and deposition of bed profile and to solve hydraulic problems affecting with bed and both-bank between upstream and downstream of intake weir in the Nakdong river channel. The movable bed model testing consists of fundamental test, movable model test and numerical analysis method respectively. The fundamental test was enforced to analyze relationship of discharge and sediment load in the tilting flume. When the movable model test was worked, it was shown that sediment budget between input sediment load and output sediment load was balanced exactly. As a result of movable model test, it was presented that scouring and deposition changes in quantities between the upstream and downstream of modification weir were less than those of nature and planning weir. Finally, numerical analysis method was operated by 1-dimensional bed profile changes model ; HEC-6 model so as to complement unsolving hard problems during movable model test. So, modification weir will sustained the stable bed profile changes than any other weirs in the study channel.

  • PDF

A Study on the PET/CT Fusion Imaging (PET/CT 결합영상진단 검사에 관한 연구)

  • Kim, Jong Gyu
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.36 no.2
    • /
    • pp.193-198
    • /
    • 2004
  • PET/CT combines the functional information from a positron emission tomography (PET) exam with the anatomical information from a computed tomography (CT) exam into one single exam. A CT scan uses a combination of x-rays and computers to give the radiologist a non-invasive way to see inside your body. One advantage of CT is its ability to rapidly acquire two-dimensional pictures of your anatomy. Using a computer these 2-D images can be presented in 3-D for in-depth clinical evaluation. A PET scan detects changes in the cellular function - how your cells are utilizing nutrients like sugar and oxygen. Since these functional changes take place before physical changes occur, PET can provide information that enables your physician to make an early diagnosis. The PET exam pinpoints metabolic activity in cells and the CT exam provides an anatomical reference. When these two scans are fused together, your physician can view metabolic changes in the proper anatomical context of your body. PET/CT offers significant advantages including more accurate localization of functional abnormalities, and the distinction of pathological from normal physiological uptake, and improvements in monitoring treatment. A PET/CT scan allows physicians to measure the body's abnormal molecular cell activity to detect cancer (such as breast cancer, lung cancer, colorectal cancer, lymphoma, melanoma and other skin cancers), brain disorders (such as Alzheimer's disease, Parkinson's disease, and epilepsy), and heart disease (such as coronary artery disease).

  • PDF

Investigation of the Performance of the Alternative Refrigerant HFC-134a through Capillary tube : Numerical Analysis (대체냉매 HFC-134a의 모세관 성능에 관한 수치해석적 연구)

  • Kim, C.N.;Park, Y.M.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.3
    • /
    • pp.169-178
    • /
    • 1993
  • Performance charts of capillary tubes for R-134a are presented. The calculation is based on the one-dimensional, adiabatic flow through capillary tube. The length of capillary tube changes with inlet pressure, mass flux, inlet quality(or subcooling), and inside diameter. The length for R-134a is shorter by 12.5~23% than that for R-12 as mass flux varies, by 13~18.5% as inlet pressure changes, by 15~15.2% as inside diameter changes, and by 3.6~20% as subcooling(or quality) changes. In general, the length for R-134a is shorter than that for R-12 by 10~20%. Pressure drop per unit length for R-134a is greater than that for R-12 since specific volume of R-134a is larger that of R-12 and vapor pressure of R-134a is greater than that of R-12. Flash point of R-134a is ahead of that of R-12.

  • PDF

Implications of the Periodicity in NMR Chemical Shifts and Temperature Coefficients of Amide Protons in Helical Peptides

  • Suh, Jeong-Yong;Choi, Byong-Seok
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.8 no.2
    • /
    • pp.127-138
    • /
    • 2004
  • We obtained the chemical shifts of amide protons (NHs) in helical peptides at various temperatures and trifluoroethanol (TFE) concentrations using 2-dimensional NMR spectroscopy. These NH chemical shifts and their temperature dependence exhibited characteristic periodicity of 3-4 residues per cycle along the helix, where downfield shifted NHs showed larger temperature dependence. In an attempt to understand these observations, we focused on hydrogen bonding changes in the peptides and examined the validity of two possible explanations: (1) changes in intermolecular hydrogen bonding caused by differential solvation of backbone carbonyl groups by TFE, and (2) changes in intramolecular hydrogen bonding due to disproportionate variations in the hydrogen bonding within the peptide helix. Interestingly, the slowly exchanging NHs, which were on the hydrophobic side of the helix, showed consistently larger temperature dependences. This could not be explained by the differential solvation assumption, because the slowly exchanging NHs would become more labile if the preceding carbonyl groups were preferentially solvated by TFE. We suggest that the disproportionate changes in intramolecular hydrogen bonding better explain both the temperature dependence and the exchange behavior observed in this study.

  • PDF

Vibration-based delamination detection of composites using modal data and experience-based learning algorithm

  • Luo, Weili;Wang, Hui;Li, Yadong;Liang, Xing;Zheng, Tongyi
    • Steel and Composite Structures
    • /
    • v.42 no.5
    • /
    • pp.685-697
    • /
    • 2022
  • In this paper, a vibration-based method using the change ratios of modal data and the experience-based learning algorithm is presented for quantifying the position, size, and interface layer of delamination in laminated composites. Three types of objective functions are examined and compared, including the ones using frequency changes only, mode shape changes only, and their combination. A fine three-dimensional FE model with constraint equations is utilized to extract modal data. A series of numerical experiments is carried out on an eight-layer quasi-isotropic symmetric (0/-45/45/90)s composited beam for investigating the influence of the objective function, the number of modal data, the noise level, and the optimization algorithms. Numerical results confirm that the frequency-and-mode-shape-changes-based technique yields excellent results in all the three delamination variables of the composites and the addition of mode shape information greatly improves the accuracy of interface layer prediction. Moreover, the EBL outperforms the other three state-of-the-art optimization algorithms for vibration-based delamination detection of composites. A laboratory test on six CFRP beams validates the frequency-and-mode-shape-changes-based technique and confirms again its superiority for delamination detection of composites.

Crosstalk evaluation in multiview autostereoscopic three-dimensional displays with an optimized diaphragm applied

  • Peng, Yi-Fan;Li, Hai-Feng;Zheng, Zhen-Rong;Xia, Xin-Xing;Yao, Zhi;Liu, Xu
    • Journal of Information Display
    • /
    • v.13 no.2
    • /
    • pp.83-89
    • /
    • 2012
  • The crosstalk evaluation of multiview autostereoscopic three-dimensional (3D) displays is discussed, with both the human and technical factors investigated via image quality assessment. In the imaging performance measurements and analysis for a multiview autostereoscopic display prototype equipment, it was inferred that crosstalk would have both a positive and a negative effect on the imaging performance of the equipment. The importance of the attached diaphragm in the crosstalk evaluation was proposed and then experimentally verified, using the developed prototype equipment. The luminance distribution and crosstalk situation were given, with two different diaphragm arrays applied. The analysis results showed that the imaging performance of this 3D display system can be improved with minimum changes to the system structure.

Three dimensional finite element analysis of 4 inch smart flange on offshore pipeline

  • Moghaddam, Ali Shaghaghi;Mohammadnia, Saeid
    • Ocean Systems Engineering
    • /
    • v.4 no.4
    • /
    • pp.279-291
    • /
    • 2014
  • Smart flanges are used for pipeline and riser repair in subsea. In a typical case in the gas export pipeline project, the end cap bolts of a 4inch smart flange were broken during operation, and in turn leakage occurred. This work presents the detail of three dimensional finite element analysis of the smart flange to support the observed end cap bolts failure. From finite element analysis it turns out that in the presence of external bending moment, an uneven contact distribution is present between seal and end cap, which in turn changes the uniform load distribution on bolts and threaten the integrity of bolts. On the other hand, 3D finite element analysis of interaction between pipeline and seabed is presented by means of Abaqus to explore the distribution of bending moment along the pipeline route. It is found that lateral buckling occurs in the pipeline which introduces large bending moment.

An Image Depth Estimation Algorithm based on Pixel-wise Confidence and Concordance Correlation Coefficient (픽셀단위 상대적 신뢰도와 일치상관계수를 이용한 영상의 깊이 추정 알고리즘)

  • Kim, Yeonwoo;Lee, Chilwoo
    • Journal of Korea Multimedia Society
    • /
    • v.21 no.2
    • /
    • pp.138-146
    • /
    • 2018
  • In this paper, we describe an algorithm for extracting depth information from a single image based on CNN. When acquiring three-dimensional information from a single two-dimensional image using a deep-learning technique, it is difficult to accurately predict the edge portion of the depth image because it is a part where the depth changes abruptly. in this paper, we introduce the concept of pixel-wise confidence to take advantage of these characteristics. We propose an algorithm that estimates depth information from a highly reliable flat part and propagates it to the edge part to improve the accuracy of depth estimation.

The Analysis of H-Shape Rolling by the Finite Element Method (유한요소법에 의한 H형강 압연공정의 해석)

  • 신현우;김낙수;박종진
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.5
    • /
    • pp.1095-1105
    • /
    • 1993
  • Shape rolling processes to produce H-section beams are numerically simulated by the simplified three-dimensional finite element method. The 2-dimensional finite element method, used for the generalized plane strain condition, is combined with the slab method. Computer simulation results of the 19-passes in H-section beam rolling in practice include the grid distortions, the cross-sectional area changes, the roll separating forces, and the roll torques. Also, the amount of side spread can be found during the multi-pass rolling simulations. The finite element mesh system is remeshed with I-DEAS whenever the billet distorts severely. This study would contribute to CAD/CAM of shape rolling process through the optimal roll pass schedule.

Factors Affecting the Magnitude of the Metal-Insulator Transition Temperature in AMo4O6 (A=K, Sn)

  • Jung, Dong-Woon;Choi, Kwang-Sik;Kim, Sung-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.7
    • /
    • pp.959-964
    • /
    • 2004
  • A low-dimensional metal frequently exhibits a metal-insulator transition through a charge-density-wave (CDW) or a spin-density-wave (SDW) which accompany it's structural changes. The transition temperature is thought to be determined by the amount of energy produced during the transition process and the softness of the original structure. $AMo_4O_6$ (A=K, Sn) are known to be quasi-one dimensional metals which exhibit metalinsulator transitions. The difference of the transition temperatures between $KMo_4O_6$ and $SnMo_4O_6$ (A=K, Sn) is examined by investigating their electronic and structural properties. Fermi surface nesting area and the lattice softness are the governing factors to determine the metal-insulator transition temperature in $AMo_4O_6$ compounds.