• Title/Summary/Keyword: Dimensional Control

Search Result 2,862, Processing Time 0.035 seconds

The Influence of Rearfoot Motion Control through Marathon Shoes On and Off (마라톤화 착용 시 후족제어에 미치는 영향)

  • Kim, Young-Jae;Jang, Sung-Il
    • Korean Journal of Applied Biomechanics
    • /
    • v.15 no.2
    • /
    • pp.69-81
    • /
    • 2005
  • In this study using two-dimensional system of the analysis of image, when normal males in their twenties who have normal foot and step with heel first are walking and running, they who are wearing running shoes or barefoot are testing and comparing the exchange factors of heel control. There are following results of this test by verifying them with T-Test. 1) When they are running, there are two big different gap which is $6.05^{\circ}$ between barefoot and wearing the running shoes. The former is $174.79^{\circ}{\pm}6.31$ and the latter is $180.84^{\circ}{\pm}4.69$. But it is not statistically significant. The angle of first step with heel is $100.42^{\circ}{\pm}3.95$ with barefoot and $93.97^{\circ}{\pm}094$ with wearing the running shoes. In this case, it is statistically significant(p<.01) 2) When they are running, the angle of the Achilles' tendon has different gap which is $5.24^{\circ}$ between barefoot and wearing the running shoes. The former is $179.70^{\circ}{\pm}4.23$ and the latter is $184.94^{\circ}{\pm}4.09$. It is not statistically significant. The angle of minimal step with heel is $96.30^{\circ}{\pm}3.07$ with barefoot and $90.84^{\circ}{\pm}0.44$ with wearing the running shoes. In this case, it is statistically significant(p<.01). 3) In the angle of the Achilles' tendon and the angle of first step with heel, when they are walking, the angle of the Achilles' tendon has different gap which is $1.81^{\circ}$ between barefoot and wearing the running shoes. The former is $6.39^{\circ}{\pm}0.83$ and the latter is $8.20^{\circ}{\pm}1.85$. It is not statistically significant. The angle of first step with heel is $2.32^{\circ}{\pm}0.51$ with barefoot and $3.22^{\circ}{\pm}1.44$ with wearing the running shoes. It is not statistically significant. 4) In the angle of the take-off of Achilles' tendon, when they are walking, the angle of the take-off of Achilles' tendon has different gap which is $3.88^{\circ}$ between barefoot and wearing the running shoes. The former is $177.62^{\circ}{\pm}8.78$ and the latter is $173.74^{\circ}{\pm}16.31$. It is statistically significant(p<.05). Therefore, they are running, the angle of the take-off of Achilles' tendon is $178.37^{\circ}{\pm}19.28$ with barefoot and $171.26^{\circ}{\pm}12.18$ with wearing the running shoes. It is statistically significant(p<.05).

Proteomic Analysis of Cytokinin Induced Proteins in Arabidopsis (단백체를 이용한 애기장대 Cytokinin 유도 단백질의 분석)

  • Liang Ying-Shi;Cha Joon-Yung;Ermawati Netty;Jung Min-Hee;Bae Dong-Won;Lee Chang-Won;Son Dae-Young
    • Journal of Plant Biotechnology
    • /
    • v.32 no.4
    • /
    • pp.251-256
    • /
    • 2005
  • Cytokinins are essential plant hormones that play crucial roles in various aspects of plant growth and development. To better understand the molecular mechanisms of cytokinin action, we identified cytokinin related proteins by a proteomic approach. Proteins extracted from control and trans-zeatin treated Arabidopsis seedlings were separated and analyzed by two dimensional gel analysis. Differentially expressed protein spots were identified with peptide mass fingerprinting based on matrix assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry and database searching, We obtained ten up-regulated and one down-regulated proteins upon t-zeatin treatment. The expression of the following proteins was induced; pollen allergen like protein, L-ascorbate peroxidase, tetrapyrrole methylase family protein, SGT1 protein homolog, disease resistance related protein, maternal embryogenesis control protein, paxneb related protein, gluthathione S-transferase and IAA amino acid hydrolase homolog.

Characterization of tissue conditioner containing chitosan-doped silver nanoparticles (키토산-은나노 복합체가 함유된 의치 연성이장재 특성에 관한 연구)

  • Nam, Ki Young;Lee, Chul Jae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.4
    • /
    • pp.275-281
    • /
    • 2020
  • Purpose: Development of a latent antimicrobial soft liner is strongly needed to overcome a possible inflammation related with its dimensional degrade or surface roughness. Modified tissue conditioner (TC) containing chitosan-doped silver nanoparticles (ChSN) complexes were synthesized and assessed for their characterizations. Materials and methods: ChSN were preliminarily synthesized from silver nitrate (AgNO3), sodium borohydride (NaBH4) as a reducing agent and chitosan biopolymer as a capping agent. Ultraviolet-visible and Fourier transform infrared spectroscopy were conducted to confirm the stable reduction of nanoparticles with chitosan. Modified TC blended with ChSN by 0 (control), 1.0, 3.0 and 5.0 % mass fraction were mechanically tested by ultimate tensile strength (UTS), silver ion elution and color stability (n=7). Results: At 24 hour and 7 day storage periods, UTS values were not significant (P>.05) as compared with pristine TC (control) and silver ion was detected with the dose-dependent values of ChSN incorporated. Color stability of TC were influenced by ChSN add, with the higher doses, the significantly greater color changes (P<.05). Conclusion: A stable synthesized ChSN was acquired and modified TC loading ChSN was characterized as silver ion releasing without detrimental physical property. For its clinical application, antimicrobial test, color control and multifactor investigations are still required.

Analysis of influence on water quality and harmful algal blooms due to weir gate control in the Nakdong River, Geum River, and Yeongsan River (낙동강, 금강 및 영산강 가동보 운영이 수질 및 녹조현상에 미치는 영향 분석)

  • Seo, Dongil;Kim, Jaeyoung;Kim, Jinsoo
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.10
    • /
    • pp.877-887
    • /
    • 2020
  • A 3-Dimensional hydrodynamic and water quality model was applied to evaluate the effects of weir gate operations on water quality and harmful algal bloom (HAB) occurrences at selected locations in the Nakdong River, Geum River, and Yeongsan River. For the Geum River and Yeongsan River, when the gates are left open, annual and summer Chl-a and HABs were decreased at upstream locations, Sejong Weir and Seungchon Weir, but summer average concentrations of Chl-a and HABs were increased at downstream locations, Baekje Weir and Juksan Weir. For the open scenario, the reduced hydraulic residence time in the upper stream areas of the Geum River and Yeongsan River would allow less available time for nutrient consumption that would result in higher dissolved inorganic phosphorus concentrations followed by higher algal growth in the downstream areas. However, in the case of the Nakdong River, both annual and summer Chl-a and HABs were increased in all locations for the open scenario. This condition seems to be resulted in due to increased light availability by reduced water depths. Changes in Chl-a and HABs occurrences due to the water gate control in the study sites are different due to differences in physical, chemical, and biological conditions in each location.

Accuracy Analysis of HEC-RAS for Unsteady Flow Simulation considering the Flow Pattern Variations over the Side-weir of Side-Weir Detention Basin (강변저류지 횡월류부의 흐름 형태 변화를 고려한 HEC-RAS의 하도 내 부정류 모의 정확도 분석)

  • Kim, Sanghyuk;Yoon, Byungman;Kim, Dongsu;Kim, Seojun
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.1
    • /
    • pp.29-39
    • /
    • 2016
  • Accurate quantitative assessment of flood control effect of side-weir detention basin as a flood countermeasure was highly required, in which one-dimensional HEC-RAS model has been widely utilized in practice. When the submerged overflow occurred particularly driven by limited storage capacity of a given detention basin, HEC-RAS model could not be sufficiently applicable by guaranteeing acceptable accuracy without reliable benchmark dataset. From this perspective, a dedicated unsteady experiment was planned and carried out to physically realize such submerged overflow for accommodating better accuracy. Subsequently, the experimental results were applied to validate and calibrate HEC-RAS unsteady modeling to provide flood control effect of the detention basin for various inflow scenarios. After following this procedure, the modelled results indicated that there appeared within -5% of difference in stage height and maximum 2.4% accuracy to assess the flood control effect, thereby ensuring the calibrated HEC-RAS unsteady model to be accurate with practically acceptable error range.

Effect of Vapor-Cooled Heat Stations in a Cryogenic Vessel (극저온액체 저장용기에서 열전도 차폐단의 영향)

  • Kim, S.Y.;Kang, B.H.;Choi, H.J.
    • Journal of Hydrogen and New Energy
    • /
    • v.9 no.4
    • /
    • pp.169-176
    • /
    • 1998
  • An experimental study on effect of vapor-cooled heat stations in a 5.5 liter cryogenic vessel has been performed. The cryogenic vessel is made of stainless steel of thickness of 1mm and insulated by the combined insulation of vacuum, MLI(multi-layer insulation) and vapor-cooled radiation shield. Vapor-cooled heat stations are also constructed based on the 1-dimensional thermal analysis to reduce the heat inleak through a filling tube. Thermal analysis indicates that the vapor-cooled heat stations can substantially enhance the performance of vessel for cryogenic fluids with high $C_p/h_{fg}$ where $C_p$ the specific heat and $h_{fg}$ the heat of vaporization, such as $LH_2$ and LHe. The experimental results for $LN_2$ shows that the total heat inleak into inner vessel consists of 14% radiation and 86% conduction through the filling tube. Therefore, it is expected that the conduction heat in leak of the vessel for high $C_p/h_{fg}$ cryogenic fluids can be significantly reduced. powders. The amount of copper coating was 20wt%. In order to examine corrosion behavior of the electrodes, the corrosion current and the current density, in 6M KOH aqueous solution after removal of oxygen in the solution, were measured by potentiodynamic and cyclic voltamo methods. The results showed that Co in the alloy increased corrosion resistance of the electrode whereas Ni decreased the stability of the electrode during the charge-discharge cycles. The electrode used Si sealant as a binder showed a lower corrosion current density than the electrode used PTFE and the electrode used Cu-coated alloy powders showed the best corrosion resistance.

  • PDF

Blood Flow Simulation in Bifurcated Geometry of Abdominal and Iliac Arteries Based on CT Images (CT영상에 기반한 복부대동맥과 장골동맥 분기관 모델의 혈류유동 해석)

  • Hong Y. S.;Kim M. C.;Kang H. M.;Lee C. S.;Kim C. J.;Lee J. M.;Kim D. S.;Lee K.
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.497-503
    • /
    • 2004
  • Numerical simulation of blood flow has been conducted based on real vessel geometries generated front DICOM medical images of abdominal and iliac bifurcated arteries of a healthy man. A program was developed to read cross sectional images of the three dimensional arteries and smoothly extract boundary coordinates of vessels. Commercial programs were employed for mesh generation and flow simulation. Pressures, velocities, and flow distributions were found to lie within normal physiological ranges. Peak velocity measured in the iliac artery by ultrasound was 20% smaller than that obtained by simulation. The trend of velocity variation in a cardiac cycle was fairly similar between the simulation and the ultrasonic measurements. Simulation based on real vessel geometry of individual patient provides information on pressure, velocity, and its distribution in the diseased arteries or arteries to be surgically treated. The results of simulation may help surgeons to better understand hemodynamic status and surgical need of the patient by revealing variation of the hemodynamic parameters. Futhermore, they may serve as basic data for surgical treatment of arteries. This research is expected to develop to a program in the future that early diagnose atherosclerosis by showing distribution of a hemodynamic index closely related to atherosclerosis in arteries.

User Needs of Three Dimensional Hand Gesture Interfaces in Residential Environment Based on Diary Method (주거 공간에서의 3차원 핸드 제스처 인터페이스에 대한 사용자 요구사항)

  • Jeong, Dong Yeong;Kim, Heejin;Han, Sung H.;Lee, Donghun
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.41 no.5
    • /
    • pp.461-469
    • /
    • 2015
  • The aim of this study is to find out the user's needs of a 3D hand gesture interface in the smart home environment. To find out the users' needs, we investigated which object the users want to use with a 3D hand gesture interface and why they want to use a 3D hand gesture interface. 3D hand gesture interfaces are studied to be applied to various devices in the smart environment. 3D hand gesture interfaces enable the users to control the smart environment with natural and intuitive hand gestures. With these advantages, finding out the user's needs of a 3D hand gesture interface would improve the user experience of a product. This study was conducted using a diary method to find out the user's needs with 20 participants. They wrote the needs of a 3D hand gesture interface during one week filling in the forms of a diary. The form of the diary is comprised of who, when, where, what and how to use a 3D hand gesture interface with each consisting of a usefulness score. A total of 322 data (209 normal data and 113 error data) were collected from users. There were some common objects which the users wanted to control with a 3D hand gesture interface and reasons why they want to use a 3D hand gesture interface. Among them, the users wanted to use a 3D hand gesture interface mostly to control the light, and to use a 3D hand gesture interface mostly to overcome hand restrictions. The results of this study would help develop effective and efficient studies of a 3D hand gesture interface giving valuable insights for the researchers and designers. In addition, this could be used for creating guidelines for 3D hand gesture interfaces.

Dosimetric advantages and clinical outcomes of simultaneous integrated boost intensity-modulated radiotherapy for anal squamous cell carcinoma

  • Sakanaka, Katsuyuki;Itasaka, Satoshi;Ishida, Yuichi;Fujii, Kota;Horimatsu, Takahiro;Mizowaki, Takashi;Sakai, Yoshiharu;Hiraoka, Masahiro
    • Radiation Oncology Journal
    • /
    • v.35 no.4
    • /
    • pp.368-379
    • /
    • 2017
  • Purpose: The purpose of this study was to explore the dosimetric difference between simultaneous integrated boost intensity-modulated radiotherapy (SIB-IMRT) and three-dimensional conformal radiotherapy (3DCRT), and the clinical outcomes of anal squamous cell carcinoma (ASCC) chemoradiotherapy featuring SIB-IMRT. Materials and Methods: This study included ten patients with ASCC who underwent chemoradiotherapy using SIB-IMRT with 5-fluorouracil and mitomycin C. SIB-IMRT delivered 54 Gy to each primary tumor plus metastatic lymph nodes and 45 Gy to regional lymph nodes, in 30 fractions. Four patients received additional boosts to the primary tumors and metastatic lymph nodes; the median total dose was 54 Gy (range, 54 to 60 Gy). We additionally created 3DCRT plans following the Radiation Therapy Oncology Group 9811 protocol to allow dosimetric comparisons with SIB-IMRT. Locoregional control, overall survival, and toxicity were calculated for the clinical outcome evaluation. Results: Compared to 3DCRT, SIB-IMRT significantly reduced doses to the external genitalia, bladder, and intestine, delivering the doses to target and elective nodal region. At a median follow-up time of 46 months, 3-year locoregional control and overall survival rates were 88.9% and 100%, respectively. Acute toxicities were treated conservatively. All patients completed radiotherapy with brief interruptions (range, 0 to 2 days). No patient experienced ${\geq}grade$ 3 late toxicity during the follow-up period. Conclusion: The dosimetric advantages of SIB-IMRT appeared to reduce the toxicity of chemoradiotherapy for ASCC achieving high locoregional control in the extended period.

Analysis of the Effect of Intralesional Steroid Injection on the Voice During Laryngeal Microsurgery (후두 미세수술 중 병변 내 스테로이드 주입이 음성에 미치는 효과 분석)

  • Jae Seon, Park;Hyun Seok, Kang;In Buhm, Lee;Sung Min, Jin;Sang Hyuk, Lee
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.33 no.3
    • /
    • pp.166-171
    • /
    • 2022
  • Background and Objectives Vocal fold (VF) scar is known to be the most common cause of dysphonia after laryngeal microsurgery (LMS). Steroids reduce postoperative scar formation by inhibiting inflammation and collagen deposition. However, the clinical evidence of whether steroids are helpful in reducing VF scar formation after LMS is still lacking. The purpose of this study is to determine whether intralesional VF steroid injection after LMS helps to reduce postoperative scar formation and voice quality. Materials and Method This study was conducted on 80 patients who underwent LMS for VF polyp, Reinke's edema, and leukoplakia. Among them, 40 patients who underwent VF steroid injection after LMS were set as the injection group, and patients who had similar sex, age, and lesion size and who underwent LMS alone were set as the control group. In each group, stroboscopy, multi-dimensional voice program, Aerophone II, and voice handicap index (VHI) were performed before and 1 month after surgery, and the results were statistically analyzed. Results There were no statistically significant differences in the distribution of sex, age, symptom duration, occupation and smoking status between each group. Both groups consisted of VF polyp (n=21), Reinke's edema (n=11), and leukoplakia (n=9). On stroboscopy, the lesion disappeared after surgery, and the amplitude and mucosal wave were symmetrical on both sides of the VFs in all patients. Acoustic parameters and VHI significantly improved after surgery in all patients. However, there was no significant difference between the injection and control group in most of the results. Conclusion There was no significant difference in the results of stroboscopy, acoustic, aerodynamic, and subjective evaluation before and after surgery in the injection group and the control group.