• 제목/요약/키워드: Dilution rate

검색결과 573건 처리시간 0.025초

고정화 미생물에 의한 에너지 생산 - 광합성 박테리아에 의한 수소 생산 - (Biofuel Production by Immobilized Living Cells - Hydrogen Production by Photosynthetic Bacteria -)

  • 조영일;선용호
    • 한국미생물·생명공학회지
    • /
    • 제13권3호
    • /
    • pp.303-309
    • /
    • 1985
  • Continuous production of hydrogen by Ca alginate-immobilized photosynthetic bacteria was studied in a packed-bed bioreactor. The dilution rate and input concentration of carbonaces substrate were selected as operating parameters. To choose the strain for immobilization, hydrogen productivities of Rhodopseudomonas caposulata 10006 and Rhodospirillum rubrum KS-301 were compared through preliminary batch cultures of their free cells: the former was found to show better hydrogen productivity in spite of its lower specific growth rate. For the continuous production of hydrogen by immobilized R capsulata, the optimum dilution rate was about 0.84 h$^{-1}$ . The Immobilized tells gave better hydrogen yield and conversion efficiency than free ones. And a kinetic parameter K'$_{m}$ was determined for the packed-bed bioreactor, being practically constant for a specific range of dilution rates.s.

  • PDF

미생물 고정화를 이용한 산성염료의 처리 (Treatment of Acid dye Using Microbial Immobilization)

  • 김정목;조무환;양용운
    • 한국염색가공학회지
    • /
    • 제11권2호
    • /
    • pp.19-26
    • /
    • 1999
  • Strains degrading and decolorizing acid dyes, Nylosan red E-BL 150%. were isolated from natural system, was named as ARK3. The optimal culture conditions of temperature and pH were $35^\circ{C}$, 7.0, respectively. Growth rate of cells in conditions of aerobic shaking more than standing culture conspicuously increased, and optical density of those to strain ARK3 were found as 1.38 and 0.25 after 42 hrs. Decolorization efficiency in batch culture which used as immobilization media to natural zeolite was 15% after 6 hrs, while suspension culture was 5%, also its of immobilization and suspension culture were 90% and 85% after 48 hrs, respectively. Decolorization efficiency of air-lift bioreactor was more than 90% to a dilution rate of $0.038hr^{-1}$, but that was decreased as 70%, when the dilution rate was $0.05hr^{-1}$. Even though at maximum dilution rate of this study, there was not appeared "wash out" phenomienon of biomass. Decolorization efficiency was 97.7% at a dilution rate of $0.025hr^{-1}$, when influent dye concentration was $100mg/\ell$. But if influent dye concentration increased as $150mg/\ell$, even though MLVSS increased, that of treatment water decreased as 93%. Also, when influent dye concentration increased as $200mg/\ell$ and $300mg/\ell$, decolorization efficiencies of treatment water abruptly decreased as 85% and 63%, respectively. Decolorization efficiency was more than 92% to the limit volumetric loading rate of $3.75mg/\ell\cdot{hr}$hr, without regard to variation of influent dye concentration or hydraulic retention time. if volumetric loading rate was more than $3.80mg/\ell\cdot{hr}$, at same condition, decolorization efficiency was lower decrease of retention time than increase of influent dye concentration.entration.

  • PDF

하지 혈관조영검사 시 매개변수인 관전류와 SOD에 변화에 대한 조영제 희석률 분석 (Analysis of Contrast Medium Dilution Rate for changes in Tube Current and SOD, which are Parameters of Lower Limb Angiography Examination)

  • 공창기;한재복
    • 한국방사선학회논문지
    • /
    • 제14권5호
    • /
    • pp.603-612
    • /
    • 2020
  • 본 연구의 목적은 하지 혈관조영검사에서 매개변수인 관전류 (mA)와 SOD에 대한 조영제 농도(300, 320, 350) 희석률의 관계가 화질에 미치는 영향을 알아보는 데 있다. 이를 위해 말초혈관 직경 크기로 자체 제작한 3 mm 혈관모형 Water 팬텀을 이용하여, 관전류 (mA), SOD 변화와 조영제 농도(300, 320, 350) 희석률 변화의 관계를 SNR 값과 CNR 값으로 측정하고 변동계수를 (cv < 10) 분석하였다. SNR 값과 CNR 값의 측정에 사용된 소프트웨어는 Image J 1.50i, (NIH) National Institutes of Health, USA)로, PACS에 전송된 의료영상표준(DICOM, digital imaging and communications in medicine) 3.0 파일에서 팬텀에 대한 관심영역(ROI, region of interest)과 배경(Background)의 영상 신호를 수치적으로 확인한 후 평균 신호값(MPV, mean pixel value)과 표준편차(SD, standard deviation)를 이용하였다. 관전류 변화에 대한 조영제 농도별 희석률에서 관전류 (146 mA)과 관전류 (102 mA)의 SNR과 CNR 비교결과, SNR과 CNR 모두 CM : N/S 희석률 (100% ~ 30% : 70%) 구간까지 변동계수 값이 10 이하로 작게 나타났으나, CM : N/S 희석률 (20% : 80%~ 10% : 90%) 구간에서는 변동계수 값이 10 이상으로 나타났다. SOD 변화에 대한 조영제 농도별 희석률에서 SOD (32.5 cm)과 SOD (22.5cm)의 SNR과 CNR 비교 결과, SNR과 CNR 모두 CM : N/S 희석률 (100% ~ 30% : 70%) 구간까지 변동계수 값이 10 이하로 작게 나타났으나, CM : N/S 희석률 (20% : 80%~ 10% : 90%) 구간에서는 변동계수 값이 10 이상으로 나타났다. SOD 변화에 대한 조영제 농도별 희석률에서 SOD (32.5 cm)과 SOD (12.5cm)의 SNR과 CNR 비교 결과, SNR과 CNR 모두 CM : N/S 희석률 (100% ~ 30% : 70%) 구간까지 변동계수 값이 10 이하로 작게 나타났다. 그러나 CM : N/S 희석률 (20% : 80%~ 10% : 90%) 구간에서는 변동계수 값이 10 이상으로 나타났다. 결과적으로 인터벤션에서 하지 말초혈관조영술을 포함한 다른 검사나 시술에서 낮은 관전류 값을 설정하고, 테이블은 영상수상기에 최대한 가깝게 하여, 조영제 농도(300)을 CM : N/S 희석률 (30% : 70%)로 사용하는 것이 신장에 대한 부담과 피폭에 대한 부담을 동시에 줄이면서 적정 농도의 영상을 얻을 수 있는 가장 효율적인 방법으로 제시한다.

혈관조영검사에서 매개변수 변화에 따른 Roadmap 영상의 화질평가 (Evaluation of Roadmap Image Quality by Parameter Change in Angiography)

  • 공창기;송종남;한재복
    • 한국방사선학회논문지
    • /
    • 제14권1호
    • /
    • pp.53-60
    • /
    • 2020
  • 이 연구의 목적은 Roadmap 영상에서 화질에 영향을 미치는 인자들을 알아보기 위한 것으로, 조영제의 희석률, Collimation Field, Flow Rate를 변화하여 연구를 하였다. 화질의 정량적인 평가를 위해, 아크릴를 이용하여 3mm 혈관모형의 Water Phantom을 자체 제작하였고, 자체 제작한 혈관모형의 Water Phantom으로 Roadmap 영상을 획득하고, SNR(Signal to Noise Ratio)과 CNR(Contrast to Noise Ratio)을 분석하였다. CM : N/S 희석률 변화에 대한 연구에서 CM : N/S 희석률을 (100%~10% : 100%)로 변화를 주었으며, 혈관모형 Water Phantom을 이용하여 촬영한 Roadmap 영상의 SNR과 CNR의 측정 결과 CM에 N/S 희석률이 높아질수록 SNR의 측정값이 점차적으로 낮아짐을 나타났고, CNR의 측정값도 점차적으로 낮아짐을 나타났다. 결론적으로 CM : N/S의 희석률이 높아질수록 SNR과 CNR 낮아짐을 확인하였고, CM : N/S의 희석률(100%~70 : 30%)에서 유의한 이미지를 얻을 수 있음을 확인하였다. Collimation Field 변화에 대한 연구에서 혈관모형 Water Phantom을 이용하여 Colimation Field를 혈관모형 중심으로 좌, 우 2 cm 간격으로 좁히면서 0 cm, 2 cm, 4 cm, 6 cm, 8 cm 10 cm, 12 cm으로 각각 변화를 주었으며, Roadmap을 촬영한 영상의 SNR과 CNR의 측정 결과는 Collimation Field를 혈관모형 중심으로 좁힐수록 SNR과 CNR의 측정값이 증가하는 것을 확인할 수 있었다. Flow rate 변화에 대한 연구에서 Autoinjector의 Volume을 15로 일정하게 하고, Flow Rate를 1, 2, 3, 4, 5, 6, 7, 8, 9, 10 으로 각각 변화를 주었다. 혈관모형 Water Phantom을 이용하여 Roadmap 영상을 촬영한 이미지의 SNR과 CNR의 측정 결과 Flow Rate를 증가했을 때, SNR의 측정값이 점차적으로 감소하다가 Flow Rate 9~10에서 SNR의 측정값이 점차적 증가를 보였고, CNR의 측정값도 점차적으로 감소하다가 Flow Rate 9~10에서 CNR의 측정값이 점차적으로 증가를 보였다. 그러나 ROI Mean 값과 Background Mean 값으로 SNR과 CNR의 상관관계를 확인할 수 없었다. 상관관계를 확인하기 위해 Flow Rate 변화에 따른 Roadmap 연구는 향후 더 많은 연구로 확인해야 할 것으로 사료된다. 결론적으로 Roadmap 영상의 화질에 영향을 미치는 인자들을 알아보기 위해 조영제의 희석률, Collimation Field, Flow Rate 변화에 대한 연구에서 조영제에 N/S의 희석률이 증가할수록 SNR과 CNR이 낮아져 화질과 대조도가 낮아지는 것을 확인하였으며, Collimation Field를 좁힐수록 SNR과 CNR이 증가하여 화질과 대조도가 높아지는 것을 확인하였다. 그러나 Flow Rate 변화에 대한 연구에서는 상관관계를 확인할 수 없었다. 검사 및 시술을 할 때 신장의 영향을 최소화하기 위해 적절한 조영제 농도 선택과 대조도 향상 및 피폭 감소를 위한 적절한 Collimation Field를 사용하는 것이 유용할 것으로 판단된다.

화력발전소 굴뚝 미세먼지 측정을 위해 개발한 이젝터-다공튜브 희석장치의 희석비 검증 (Verification of dilution ratio of the newly developed ejector-porous tube diluter for measurement of fine dust in coal-fired power plant stack)

  • 신동호;김영훈;서현수;홍기정;김학준;김용진;한방우;이가영;천성남;황정호
    • 한국입자에어로졸학회지
    • /
    • 제15권3호
    • /
    • pp.105-113
    • /
    • 2019
  • The exhaust emissions from coal-fired power plants have received much attention because coal-fired power plants are the one of the largest sources of particulate matter (PM) emissions in South Korea. To measure the PM10 and PM2.5, we developed the novel diluter which is comprised of ejector and porous tube in series. The dilution ratio must be defined to calculate particle concentrations of the sampled air as well as to probe match for the isokinetic sampling. For this reason, we verified the dilution ratio of the developed diluter by the flow rate, numerical solution, gas concentration and particle concentration. The ejector-supplied flow rates were 10-50 L/min and the porous tube-supplied flow rates were 30, 50 L/min in this study. All methods above showed similar dilution ratios to each other within 10 % error rate. The dilution ratio was confirmed by comparing mass concentrations before and after the dilution process.

Wear performance of Plasma Transferred Arc deposited layers

  • Yoon, Byoung-Hyun;Kim, Hyung-Jun;Lee, Chang-Hee
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2001년도 춘계학술발표대회 개요집
    • /
    • pp.245-247
    • /
    • 2001
  • In this study, the effects of dilution on the wear behavior of PTAW (Plasma Transferred Arc Welding) Inconel 625, Inconel 718 and Stellite 6 overlays on Nimonic 80A were investigated. Inorder to evaluate the wear performance, two-body and three-body abrasive wear test, and dry sliding wear test were performed. According to wear tests, the wear rate of deposit with dilution 30% was higher than that of dilution 10% by 10%, and it was also found the plastic deformation near worn surface.

  • PDF

Evaluation of antibacterial activity against Candida albicans according to the dosage of various denture cleansers

  • Bae, Cha-Hwan;Lim, Yun-Kyong;Kook, Joong-Ki;Son, Mee-Kyoung;Heo, Yu-Ri
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권2호
    • /
    • pp.100-106
    • /
    • 2021
  • PURPOSE. The purpose of this study is to compare the antibacterial activity of currently purchasable denture cleansers against Candida albicans. Materials and methods: This study used tablet-type denture cleansers, PolidentⓇ, CoolingdentⓇ and FittydentⓇ, along with liquid denture cleansers, HexamedineⓇ, ListerineⓇ and Apple vinegarⓇ. The antibacterial activities of denture cleansers were evaluated based on the number of C. albicans and concentrations of the denture cleansers. Results. In the 0.5 × 106 cfu/㎖ culture medium, the C. albicans' death rate of PolidentⓇ was significantly lower than those of FittydentⓇ, HexamedineⓇ, ListerineⓇ, and Apple vinegarⓇ(P<.05). In the 0.5 × 107 cfu/, the C. albicans' death rates of PolidentⓇ and CoolingdentⓇ were significantly lower than those of FittydentⓇ, HexamedineⓇ, ListerineⓇ and Apple vinegarⓇ(P<.05). The C. albicans' death rates of PolidentⓇ and CoolingdentⓇ were significantly decreased at 0.02 g and 0.01 g. The C. albicans' death rate of FittydentⓇ was significantly decreased at 0.005 g (P<.05). The C. albicans' death rate of HexamedineⓇ was significantly decreased at 1/16 dilution. The C. albicans' death rate of ListerineⓇ was decreased at 1/8 dilution, and the antibacterial activity of Apple vinegarⓇ was decreased at 1/4 dilution (P<.05). Conclusion. As the number of C. albicans increased, the antibacterial activities of the denture cleansers decrease. In the tablet-type denture cleanser, all denture cleansers showed 100% C. albicans' death rate when used at a dose of 1 tablet. One denture cleanser showed the same antibacterial effect with only 1/3 of a tablet. In the liquid type denture cleanser, the level of dilution required was different for each denture cleanser.

Development of continuous process for the production of Exo-biopolymer with Cordyceps militaris

  • Kim, Kyoung-Ju;Lee, Jung-Heon
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2003년도 생물공학의 동향(XIII)
    • /
    • pp.243-245
    • /
    • 2003
  • The continuous fermentation process for exe-biopolymer production with Cordyceps militaris has been developed in this research. With the change of dilution rate, biopolymer production has been changed and the maximal biopolymer production has been achieved when the dilution rate was 0.0225/hr. The maximum mycelium concentration and biopolymer concentration were 8 g/L and 4.2 g/L, respectively.

  • PDF

Production of Beijerinckia indica HS-2001 in Fed-batch and continuous culture.

  • 양재균;서형필;신명교;이진우
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2003년도 생물공학의 동향(XII)
    • /
    • pp.245-248
    • /
    • 2003
  • As a result of broth substitutions when each culture-mediums were difference, whole culture-medium was found to be best feeding solution for production of PS-7 by B. indica. Maximal production of PS-7 was 1$10.0\;g/{\ell}$ and its conversion rate from 2% (w/v) glucose to PS-7 was 50%. After 48 hr, 50%(v/v) medium of working volume began to substitute in 7L jar fermenter. Production of PS-7 increased after 48hr, recovered productivity of PS-7. Following this preliminary culture, the resultant culture was subjected to continuous flow conditions controlled that the dilution rate were $0.01\;{\sim}\;0.04\;h^{-1}$. Production of PS-7 increased at dilution rate $0.0100\;h^{-1}$ whereas productivity of PS-7 decreased gradually in dilution rate $0.0200\;{\sim}\;0.0400\;h^{-1}$. Maximal production of PS-7 was $10.0\;g/{\ell}$ in continuous culture.

  • PDF

Estimation and Sensitivity Analysis of Kinetic Parameters for Plasmid Stability in Continuous Culture of a Recombinant Escherichia coli Harboring trp-operon Plasmid

  • NAM, SOO WAN;BYUNG KWAN KIM;JUNG HOE KIM
    • Journal of Microbiology and Biotechnology
    • /
    • 제4권1호
    • /
    • pp.13-19
    • /
    • 1994
  • A model equation to describe the plasmid instability in recombinant Escherichia coli fermentation is proposed. The equation allows one to estimate easily the two model parameters; (1) the difference in the specific growth rates between plasmid-free cells and plasmid-harboring cells ($\delta$), and (2) the probability of plasmid loss by plasmid-harboring cells ($\rho$). The estimated values of $\delta and \rho$ were in the range of 0.02-0.07 and $10^{-3}-10^{-5}$, respectively, and were strongly dependent on the dilution rate. As another parameter, the ratio of specific growth rates of plasmid-free cells and plasmid-harboring cells ($\alha$) was calculated and the result showed the highest value of 1.28 at the lowest dilution rate of 0.075 $hr^{-l}$, examined in this work. By the sensitivity analyses on the estimates of $\delta and \rho$, it was found that the growth rate difference ($\delta$) affected the plasmid instability more seriously than the probability of plasmid loss ($\rho$). Furthermore, the profound instability of plasmid at low dilution rate could be explained by the high values of $\alpha and \rho$.

  • PDF