• 제목/요약/키워드: Diluted factor

검색결과 60건 처리시간 0.025초

Should Cerebral Angiography Be Avoided within Three Hours after Subarachnoid Hemorrhage?

  • An, Hong;Park, Jaechan;Kang, Dong-Hun;Son, Wonsoo;Lee, Young-Sup;Kwak, Youngseok;Ohk, Boram
    • Journal of Korean Neurosurgical Society
    • /
    • 제62권5호
    • /
    • pp.526-535
    • /
    • 2019
  • Objective : While the risk of aneurysmal rebleeding induced by catheter cerebral angiography is a serious concern and can delay angiography for a few hours after a subarachnoid hemorrhage (SAH), current angiographic technology and techniques have been much improved. Therefore, this study investigated the risk of aneurysmal rebleeding when using a recent angiographic technique immediately after SAH. Methods : Patients with acute SAH underwent immediate catheter angiography on admission. A four-vessel examination was conducted using a biplane digital subtraction angiography (DSA) system that applied a low injection rate and small volume of a diluted contrast, along with appropriate control of hypertension. Intra-angiographic aneurysmal rebleeding was diagnosed in cases of extravasation of the contrast medium during angiography or increased intracranial bleeding evident in flat-panel detector computed tomography scans. Results : In-hospital recurrent hemorrhages before definitive treatment to obliterate the ruptured aneurysm occurred in 11 of 266 patients (4.1%). Following a univariate analysis, a multivariate analysis using a logistic regression analysis revealed that modified Fisher grade 4 was a statistically significant risk factor for an in-hospital recurrent hemorrhage (p=0.032). Cerebral angiography after SAH was performed on 88 patients ${\leq}3$ hours, 74 patients between 3-6 hours, and 104 patients >6 hours. None of the time intervals showed any cases of intra-angiographic rebleeding. Moreover, even though the DSA ${\leq}3$ hours group included more patients with a poor clinical grade and modified Fisher grade 4, no case of aneurysmal rebleeding occurred during erebral angiography. Conclusion : Despite the high risk of aneurysmal rebleeding within a few hours after SAH, emergency cerebral angiography after SAH can be acceptable without increasing the risk of intra-angiographic rebleeding when using current angiographic techniques and equipment.

비정형 기둥 형상을 가진 나노구조에서의 가스 투과성 실험 연구 (Permeability of the Lateral Air Flow through Unstructured Pillar-like Nanostructures)

  • 김혜원;임혜원;박정우;이상민;김형모
    • Tribology and Lubricants
    • /
    • 제39권5호
    • /
    • pp.197-202
    • /
    • 2023
  • Recently, research on experimental and analytical techniques utilizing microfluidic devices has been pursued. For example, lab-on-a-chip devices that integrate micro-devices onto a single chip for processing small sample quantities have gained significant attention. However, during sample preparation, unnecessary gases can be introduced into the internal channels, thus, impeding device flow and compromising specific function efficiency, including that of analysis and separation. Several methods have been proposed to mitigate this issue, however, many involve cumbersome procedures or suffer from complexities owing to intricate structures. Recently, some approaches have been introduced that utilize hydrophobic device structures to remove gases within channels. In such cases, the permeability of gases passing through the structure becomes a crucial performance factor. In this study, a method involving the deposition and sintering of diluted Ag-ink onto a silicon wafer surface is presented. This is followed by unstructured nano-pattern creation using a Metal Assisted Chemical Etching (MACE) process, which yields a nanostructured surface with unstructured pillar shapes. Subsequently, gas permeability in the spaces formed by these surface structures is investigated. This is achieved by experiments conducted to incorporate a pressure chamber and measure gas permeability. Trends are subsequently analyzed by comparing the results with existing theories. Finally, it can be confirmed that the significance of this study primarily lies in its capability to effectively evaluate gas permeability through unstructured pillar-like nanostructures, thus, providing quantitative values for the appropriate driving pressure and expected gas removal time in practical device operation.

Prolactin Monomeric Polyethylene Glycol Measurement Method and Study of Reference Value Verification

  • Dong Hyuk Ha;Hwa-Jin Ryu;Hyun-Su Cho;Sun-Young Shin
    • 핵의학기술
    • /
    • 제27권2호
    • /
    • pp.133-136
    • /
    • 2023
  • Purpose: Prolactin in the blood is separated into three types, and over 90% of prolactin presents as a double monomer (23 KDa). Rarely, it can exist in the size of big prolactin (150 KDa), which is called macroprolactin and is known as an autoantibody complex. When macroprolactin accounts for more than 60% of prolactin in the blood, it is called macroprolactinemia. The presence of such macroprolactin was first reported in a patient with hyperprolactinemia but without typical symptoms. Macroprolactinemia is emerging as an important cause of idiopathic hyperprolactinemia. The polyethylene glycol (PEG) precipitation method using the property of precipitating large-molecular-weight proteins is simple and recently has been widely used as a screening test. The results are in good agreement with the results of gel chromatography. The purpose of this study was to confirm the measurement method and reference value verification of monomeric prolactin in blood prolactin using the PEG precipitation method. Materials and Methods: For 40 examinees who visited the Gangnam Center of Seoul National University Hospital in 2021, the prolactin level was verified using radioimmunoassay (RIA). For macroprolactinemia PEG precipitation method, 25% PEG (molecular weight 6000kDa) solution and serum were mixed in equal amounts in a test tube, then left at room temperature for 20 minutes and centrifuged at 4℃ for 30 minutes (1500g). The prolactin level was measured in the supernatant. Results : After confirming that more than 90% of the 40 tested samples within the reference range <25 ng/mL, the same value as the reference value for prolactin was applied. Since the concentration of monomeric prolactin in serum from which macroprolactin has been removed from blood is diluted 1:1 with PEG, our laboratory is currently reporting the result by multiplying the result by a dilution factor of 2. Conclusion: Radioimmunoassay using PEG precipitation method using the property of precipitating large molecular weight proteins is simple and effective for quantitative measurement of monomeric prolactin in blood prolactin.

티탄산바륨 소재의 XRF 분석용 CRM 개발에 관한 연구 (A study on development of CRM by means of XRF analysis for fine ceramic ($BaTiO_3$))

  • 김영만;정찬이;임창호;송택용;이동수
    • 분석과학
    • /
    • 제9권4호
    • /
    • pp.382-391
    • /
    • 1996
  • 세라믹스 분야, 전자요업 분야 등에서 폭넓게 사용되고 있는 티탄산바륨 소재에 대하여 신속하고 정확하게 분석할 수 있는 X-선 형광분석용 표준물질 12종을 제작하였다. 특히 매질효과 제거, 보관성, 균질성 등을 고려하면서 융제 ($Li_2B_4O_7+LiBO_2$)로 시료를 16배 희석하여 제작 하였다. 티타늄을 비롯한 몇 원소는 매트릭스의 영향을 받는 것으로 보여 실험 계수법을 사용하고 Lucas Tooth와 Price의 식을 이용해 매트릭스의 영향을 보정해 주었다. 세 곳의 분석기관에서 X-선 형광분광기로 12개의 표준물질에 포함된 15 원소에 대하여 검정곡선을 작성해 본 결과 BaO, PbO, SrO, $Fe_2O_3$, $La_2O_3$, $SnO_2$, ZnO, $ZrO_2$, CaO들은 correlation factor가 0.995를 넘는 아주 좋은 곡선을 얻었다. $SiO_2$$Al_2O_3$는 X-선 형광세기도 약하고 correlation factor가 낮은 검정 곡선을 보였다.

  • PDF

Epidermal Growth Factor (EGF)와 anti-EGF가 생쥐배아의 발생에 미치는 영향 (Effect of Epidermal Growth Factor (EGF) and anti-EGF on Early Embryonic Development in Mice)

  • 변혜경;이호준
    • 한국가축번식학회지
    • /
    • 제21권1호
    • /
    • pp.61-69
    • /
    • 1997
  • 본 연구는 EGF와 anti-EGF가 초기 생쥐배아의 발생 및 부화에 미치는 영향을 알아보고자 실행되었다. 초기 2세포기부터 상실배까지의 배아를 EGF와 anti-EGF를 각각 처리한 Ham's F10 배양액에서 배양하여 그 발생률과 부화율을 대조군과 비교하였다. EGF 처리시 배양시간에 따른 발생률은 증진되었으나 통계학적 유의성은 없었다. EGF 처리군에서의 부화율(57.5, 62.5, 65.0, 62.5%)은 대조군(35%)에 비하여 유의하게 (p<0.01) 높았다. Anti-EGF 처리시 각 발생시기별 1:1000 실험군의 발생률은 대조군과 차이가 없었다. 그러나, 1:100 실험군의 경우, 2∼4세포기의 배아는 모두 4∼8세포기에서 정지되었고, 8세포기와 상실배의 포배형성은 48시간 이상 지연되었으며 부화 역시 대조군에 비해 억제되었다(8세포기; 2%, 44%, 상실배; 6.2%, 58.3%). 이 실험에서, EGF는 생쥐 배아의 포배형성과 부화를 증진시키는 반면, anti-EGF는 이를 억제하였다. Anti-EGF 처리시 나타나는 발생정지 현상은 anti-EGF가 배아에서 만들어지는 EGF와 반응하여 EGF의 작용을 억제시키기 때문으로 사료된다. 그러므로 EGF는 paracrine mode로서 뿐만 아니라 antocrine mode로서 생쥐 초기배아의 발생에 중요한 인자로 작용함을 알 수 있었다.

  • PDF

Cu2ZnSn(S,Se)4 Thin Film Solar Cells Fabricated by Sulfurization of Stacked Precursors Prepared Using Sputtering Process

  • Gang, Myeng Gil;Shin, Seung Wook;Lee, Jeong Yong;Kim, Jin Hyeok
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제45회 하계 정기학술대회 초록집
    • /
    • pp.97-97
    • /
    • 2013
  • Recently, Cu2ZnSn(S,Se)4 (CZTSS), which is one of the In- and Ga- free absorber materials, has been attracted considerable attention as a new candidate for use as an absorber material in thin film solar cells. The CZTSS-based absorber material has outstanding characteristics such as band gap energy of 1.0 eV to 1.5 eV, high absorption coefficient on the order of 104 cm-1, and high theoretical conversion efficiency of 32.2% in thin film solar cells. Despite these promising characteristics, research into CZTSS based thin film solar cells is still incomprehensive and related reports are quite few compared to those for CIGS thin film solar cells, which show high efficiency of over 20%. I will briefly overview the recent technological development of CZTSS thin film solar cells and then introduce our research results mainly related to sputter based process. CZTSS thin film solar cells are prepared by sulfurization of stacked both metallic and sulfide precursors. Sulfurization process was performed in both furnace annealing system and rapid thermal processing system using S powder as well as 5% diluted H2S gas source at various annealing temperatures ranging from $520^{\circ}C$ to $580^{\circ}C$. Structural, optical, microstructural, and electrical properties of absorber layers were characterized using XRD, SEM, TEM, UV-Vis spectroscopy, Hall-measurement, TRPL, etc. The effects of processing parameters, such as composition ratio, sulfurization pressure, and sulfurization temperature on the properties of CZTSS absorber layers will be discussed in detail. CZTSS thin film solar cell fabricated using metallic precursors shows maximum cell efficiency of 6.9% with Jsc of 25.2 mA/cm2, Voc of 469 mV, and fill factor of 59.1% and CZTS thin film solar cell using sulfide precursors shows that of 4.5% with Jsc of 19.8 mA/cm2, Voc of 492 mV, and fill factor of 46.2%. In addition, other research activities in our lab related to the formation of CZTS absorber layers using solution based processes such as electro-deposition, chemical solution deposition, nano-particle formation will be introduced briefly.

  • PDF

가금의 인공수정 (Artificial Insemination in Poultry)

  • Howarth, Birkett
    • 한국가축번식학회지
    • /
    • 제7권2호
    • /
    • pp.57-71
    • /
    • 1983
  • 1. Diluted chicken semen can be preserved at 2 to 5$^{\circ}C$ for 24 to 48 hr with resultant fertility of greater than 90% of that of fresh semen. Turkey semen can be preserved at 10 to 15$^{\circ}C$ for 6 to 24 hr and provide economical fertility. 2. Frozen chicken semen has given variable results; a 21 to 93% fertility ranges as compared to 92 to 94% expected with fresh semen. Highest fertility levels obtained with frozen turkey semen intravaginally inseminated have been 61 and 63% using DMSO and glycerol, respectively, as cryoprotectants. 3. The use of glycerol as a cryoprotectant reauires that its concentration in semen be reduced to less than 2% either by dialysis or centrifugation after thawing and before intravaginal insemination if optimal fertility is to be obtained. 4. The temperature at which cryoprotectants are added to semen and the time allowed for equilibration are important for subsequent fertility pre- and post-freezing. 5. The type of container used for packaging the semen, freeze or cooling rates, thaw rates and level of cryoprotectant all interact in affecting cell survival. 6. Plastic freeze straws as a packaging device for semen offers the following advantages: easy to handle, require minimal storage space, offer a wide range of freeze and thaw rates, and insemination can be made directly from them upon thawing. 7. Controlled slow cooling rates of 1 to 8$^{\circ}C$/min have thus far provided the best results for cooling chicken semen throught the transition phase change (liquid to solid) or critical temperature range of +5 to -20 or -35$^{\circ}C$. 8. Highest fertilities have been achieved with frozen chicken semen where a slow thaw rate (2。 to 5$^{\circ}C$) has been used regardless of the freeze rate. 9. To maintain a constant high level of fertility throughout a breeding season with frozen semen, a higher absolute number of spermatozoa must be inseminated (2 to 3 times as many) as compared to fresh semen since a, pp.oximately 50% are destroyed during processing and freezing. 10. The quality of semen may vary with season and age of the male. Such changes in sperm quality could be accentuated by storage effects. Thus, the correct number of spermatozoa may very well vary during the course of a breeding period. 11. As to time of insemination, it is best to avoid inseminating chicken hens within 1-2 hr after or 3-5 hr before oviposition; and turkey hens during or 7-10 hr before oviposition. 12. The physiological receptiveness of the oviduct at the time of insemination is a very important biological factor influencing fertility levels throughout the breeding season.

  • PDF

김치 유산균 배양물의 부상용 배합사료내 첨가시 넙치(Paralichthys olivaceus) 치어의 성장, 체조성 및 면역성 반응에 미치는 효과 (Effects of the Inclusion of Kimchi Lactic Acid Bacterial Culture in Extruded Pellets on the Growth, Body Composition and Immune Response of Juvenile Olive Flounder Paralichthys olivaceus)

  • 전규호;조성환;김희성;명성효;김현종;정원관;박범희;이금주
    • 한국수산과학회지
    • /
    • 제46권5호
    • /
    • pp.552-558
    • /
    • 2013
  • This study was performed to determine effects of the supplementation of Kimchi lactic acid bacterial culture in extruded pellets (EP) on the growth, body composition, blood chemistry and immune response of olive flounder Paralichthys olivaceus. Four hundred eighty individuals averaging 16.1 g were randomly distributed into 12, 180 L flow-through tanks (forty fish per tank). Four concentrations of Kimchi lactic acid bacterial culture (KL) were prepared: Control (0%), 0.1%, 0.2% and 0.5%. Three concentrations (0.1%, 0.2% and 0.5%) of Kimchi lactic acid bacterial culture were each diluted to 10% of EP weight and then fully absorbed by EP for 10 minutes. Each diet was fed to triplicate groups of fish. Fish were hand-fed to apparent satiation twice a day for 8 weeks. At the end of the 8-week feeding trial, the plasma lysozyme and bacterial activities of fish were determined. In addition, the cumulative mortality of fish was monitored for 8 days after their artificial infection with Edwardsiella tarda. The weight gain, specific growth rate, feed efficiency ratio, protein efficiency ratio, protein retention, hepatosomatic index and condition factor of fish were not affected by dietary supplementation with KL. None of the proximate composition, plasma parameters, lysozyme or bactericidal activities of fish was affected by dietary supplementation with KL. However, the cumulative mortalities of fish fed EP containing 0.1% and 0.5% Kimchi lactic acid bacterial culture were relatively low compared to that of fish fed the control diet. In conclusion, dietary supplementation with KL did not effectively improve growth, feed utilization, body composition, plasma chemistry, lysozyme, bactericidal activities or immune response of olive flounder after E. tarda infection under these experimental conditions.

주사용(走査用) $^{113m}In$ 교질(膠質)의 조제(調製) 및 흰쥐에서의 장기분포(臟器分布)에 관(關)한 연구(硏究) (A Study in Preparation of $^{113m}In$ colloid as Scanning Agent and it's Organ Distribution in Rats)

  • 고창순;이종헌;장고창;홍창기
    • 대한핵의학회지
    • /
    • 제3권1호
    • /
    • pp.73-82
    • /
    • 1969
  • The newly developed diagnostic method with application of $^{113}Sn-^{113m}In$ cow system ($^{113}Sn:\;T\frac{1}{2}$ 118 days, $^{113m}In:\;T\frac{1}{2}$ 1.7 hrs, 390 Kev, Single ${\gamma}$) has the remarkable advantages such as increased diagnostic ability by single large dose administration of $^{113m}In$ with no subsequent radiation hazard and shortened examining time. We reformed the research of following scope with the use of developed $^{113}Sn-^{113m}In$ cow (25 mCi) generator: The sizes of particles produced under various conditions were investigated, and possibility for application to the scannings of various organs such as brain, liver, lung, bone marrow and blood pool etc. were studied. Results: $^{113m}InCl_3$ solution eluted from diluted HCl solution (pH 1.5) passed through $^{113}Sn-^{113m}In$ generator, and there can be produced various sized particles of colloidal indium. And there observed the state of distribution of $^{113m}In$ in each organ which showed many differences according to the particle sizes of colloidal indium. The results are stated as follows: 1. The adjustment of pH is the most important factor in making the desirable particle size of colloidal indium. The colloid for blood pool showed the highest level as 7.1%/gm blood, at pH 1.7, the colloid of pH 3.5 for liver scanning showed the highest level, 88.4%, in the liver, the colloid pH 6 showed the highest level, 3.1%, in the spleen, and the colloid of pH 11.0 showed the highest level, 85.3%/gm, in the lung. 2. The colloid for liver scanning made with NaCl-NaOH system showed the highest liver uptake at pH 7.2, and at either higher or lower pH than 7.2 showed decrease of liver uptake more or less. 3. The activity of $^{113m}In$ eluted through $^{113}Sn-^{113m}In$ generator indicated over 90% in the initial 4 ml, and particularly 88.1%-86.0% in the initial 2 ml. 4. The incubation time, tempertaure and mechanical irritation related to colloid formation and coating of colloid were not the definite condition of influence.

  • PDF

분광광도계를 이용한 720 nm에서 망상적혈구 측정 경험 (Experience of Reticulocytes Measurement at 720 nm Using Spectrophotometer)

  • 성현호;석동인;정유현;김대중;이석재
    • 대한임상검사과학회지
    • /
    • 제49권4호
    • /
    • pp.382-389
    • /
    • 2017
  • 임상 실험실에서의 망상 적혈구 계산은 현재 수동 및 자동으로 구분된다. 현미경에 의한 망상 적혈구 수 검사는 정확성의 결여, 낮은 재현성 등이 망상 적혈구 결과의 정확성에 문제가 있다. 또한, 자동 혈액 분석기의 유동 세포 계측법은 개발 도상국 및 소규모 실험실에서 비용 때문에 사용하기가 어렵다. 따라서 본 연구는 이러한 단점을 보완 할 수 있는 새로운 방법을 찾기 위해 노력했다. 이 연구의 목적은 분광 광도계로 염색 된 망상 적혈구 수를 비교하고 또한 분광 광도계 및 유동 세포 계측기의 통계를 분석하는 것이다. 동일한 8 개의 EDTA 샘플을 36 회 반복하여 분광 광도계와 유동 세포 계측기 사이의 일치도를 비교 하였다. 이 연구는 700~780 nm에서 600 배 희석 한 표본을 10 개의 차이로 측정하였다. 흡광도에 의한 710~730 파장은 표준 및 검사와 양의 상관 관계가 있으며(r=0.967, p<0.01), 변수에 대한 상관 관계를 나타내었다. 결과에 대한 회귀 분석결과 최적 희석 계수는 600 배였다. 따라서 본 연구는 자동 분광 광도계를 이용한 망상 적혈구 흡광도 측정에 대한 경제적인 기여 그리고 망상 적혈구 관련 빈혈에 대한 모니터링 시스템 등에 기여 할 수 있는 기술적 활용을 시도한 것이다. 따라서 더욱 광범위한 연구가 필요할 것으로 사료된다.