• Title/Summary/Keyword: Digital subtraction

Search Result 215, Processing Time 0.023 seconds

Diagnosis of Unruptured Intracranial Aneurysms Using Proton-Density Magnetic Resonance Angiography: A Comparison With High-Resolution Time-of-Flight Magnetic Resonance Angiography

  • Pae Sun Suh;Seung Chai Jung;Hye Hyeon Moon;Yun Hwa Roh;Yunsun Song;Minjae Kim;Jungbok Lee;Keum Mi Choi
    • Korean Journal of Radiology
    • /
    • v.25 no.6
    • /
    • pp.575-588
    • /
    • 2024
  • Objective: Differentiating intracranial aneurysms from normal variants using CT angiography (CTA) or MR angiography (MRA) poses significant challenges. This study aimed to evaluate the efficacy of proton-density MRA (PD-MRA) compared to high-resolution time-of-flight MRA (HR-MRA) in diagnosing aneurysms among patients with indeterminate findings on conventional CTA or MRA. Materials and Methods: In this retrospective analysis, we included patients who underwent both PD-MRA and HR-MRA from August 2020 to July 2022 to assess lesions deemed indeterminate on prior conventional CTA or MRA examinations. Three experienced neuroradiologists independently reviewed the lesions using HR-MRA and PD-MRA with reconstructed voxel sizes of 0.253 mm3 or 0.23 mm3, respectively. A neurointerventionist established the gold standard with digital subtraction angiography. We compared the performance of HR-MRA, PD-MRA (0.253-mm3 voxel), and PD-MRA (0.23-mm3 voxel) in diagnosing aneurysms, both per lesion and per patient. The Fleiss kappa statistic was used to calculate inter-reader agreement. Results: The study involved 109 patients (average age 57.4 ± 11.0 years; male:female ratio, 11:98) with 141 indeterminate lesions. Of these, 78 lesions (55.3%) in 69 patients were confirmed as aneurysms by the reference standard. PD-MRA (0.253-mm3 voxel) exhibited significantly higher per-lesion diagnostic performance compared to HR-MRA across all three readers: sensitivity ranged from 87.2%-91.0% versus 66.7%-70.5%; specificity from 93.7%-96.8% versus 58.7%-68.3%; and accuracy from 90.8%-92.9% versus 63.8%-69.5% (P ≤ 0.003). Furthermore, PD-MRA (0.253-mm3 voxel) demonstrated significantly superior per-patient specificity and accuracy compared to HR-MRA across all evaluators (P ≤ 0.013). The diagnostic accuracy of PD-MRA (0.23-mm3 voxel) surpassed that of HR-MRA and was comparable to PD-MRA (0.253-mm3 voxel). The kappa values for inter-reader agreements were significantly higher in PD-MRA (0.820-0.938) than in HR-MRA (0.447-0.510). Conclusion: PD-MRA outperformed HR-MRA in diagnostic accuracy and demonstrated almost perfect inter-reader consistency in identifying intracranial aneurysms among patients with lesions initially indeterminate on CTA or MRA.

Imaging follow-up strategy after endovascular treatment of Intracranial aneurysms: A literature review and guideline recommendations

  • Yong-Hwan Cho;Jaehyung Choi;Chae-Wook Huh;Chang Hyeun Kim;Chul Hoon Chang;Soon Chan KWON;Young Woo Kim;Seung Hun Sheen;Sukh Que Park;Jun Kyeung Ko;Sung-kon Ha;Hae Woong Jeong;Hyen Seung Kang;Clinical Practice Guideline Committee of the Korean Neuroendovascular Society
    • Journal of Cerebrovascular and Endovascular Neurosurgery
    • /
    • v.26 no.1
    • /
    • pp.1-10
    • /
    • 2024
  • Objective: Endovascular coil embolization is the primary treatment modality for intracranial aneurysms. However, its long-term durability remains of concern, with a considerable proportion of cases requiring aneurysm reopening and retreatment. Therefore, establishing optimal follow-up imaging protocols is necessary to ensure a durable occlusion. This study aimed to develop guidelines for follow-up imaging strategies after endovascular treatment of intracranial aneurysms. Methods: A committee comprising members of the Korean Neuroendovascular Society and other relevant societies was formed. A literature review and analyses of the major published guidelines were conducted to gather evidence. A panel of 40 experts convened to achieve a consensus on the recommendations using the modified Delphi method. Results: The panel members reached the following consensus: 1. Schedule the initial follow-up imaging within 3-6 months of treatment. 2. Noninvasive imaging modalities, such as three-dimensional time-of-flight magnetic resonance angiography (MRA) or contrast-enhanced MRA, are alternatives to digital subtraction angiography (DSA) during the first follow-up. 3. Schedule mid-term follow-up imaging at 1, 2, 4, and 6 years after the initial treatment. 4. If noninvasive imaging reveals unstable changes in the treated aneurysms, DSA should be considered. 5. Consider late-term follow-up imaging every 3-5 years for lifelong monitoring of patients with unstable changes or at high risk of recurrence. Conclusions: The guidelines aim to provide physicians with the information to make informed decisions and provide patients with high-quality care. However, owing to a lack of specific recommendations and scientific data, these guidelines are based on expert consensus and should be considered in conjunction with individual patient characteristics and circumstances.

Role of the Inferior Thyroid Vein after Left Brachiocephalic Vein Division During Aortic Surgery

  • Park, Hyung-Ho;Kim, Bo-Young;Oh, Bong-Suk;Yang, Ki-Wan;Seo, Hong-Joo;Lim, Young-Hyuk;Kim, Jeong-Jung
    • Journal of Chest Surgery
    • /
    • v.35 no.7
    • /
    • pp.530-534
    • /
    • 2002
  • Background: In aortic surgery, division and ligation of the left brachiocephalic vein(LBV) may improve exposure of the aortic arch but controversy continues about the safety of this division and whether a divided vein should be reanastomosed after arch replacement was completed. The safety of LBV division and the fate of the left subclavian venous drainage after LBV division were studied. Material and Method: From November 1998 to January 2001, planned division and ligation of the LBV on the mid-line after median sternotomy was peformed in 10 patients during the aortic surgery with the consideration of local anatomy and distal aortic anastomosis. Assessment for upper extremity edema and neurologic symptoms, measurement of venous pressure in the right atrium and left internal jugular vein, and digital subtraction venography(DSV) of the left arm were made postoperatively. Result: In 10 patients there was improvement in access to the aortic arch for procedures on the ascending aorta or aortic arch. The mean age of patients was 62 years(range 24 to 70). Follow-up ranged from 3 weeks to 13 months. One patient died because of mediastinitis from methicilline-resistant staphylococcus aureus strain. All patients had edema on the left upper extremity, but resolved by the postoperative day 4. No patient had any residual edema or difficulty in using the left upper extremity during the entire follow-up period. No patient had postoperative stroke. Pressure difference between the right atrium and left internal jugular vein was peaked on the immediate postoperative period(mean peak pressure difference = 25mmHg), but gradually decreased, then plated by the postoperative day 4. In all DSV studies left subclavian vein flowed across the midline through the inferior thyroid venous plexus. Conclusion: We conclude that division of LBV is safe and reanastomosis is not necessary if inferior thyroid vein, which is developed as a main bridge connecting the left subclavian vein with right venous system, is preserved.

3D analysis of soft tissue around implant after flap folding suture (Flap folding suture를 활용한 판막의 고정에 따른 임플란트 주변 연조직 3차원 부피 변화 관찰)

  • Jung, Sae-Young;Kang, Dae-Young;Shin, Hyun-Seung;Park, Jung-Chul
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.37 no.3
    • /
    • pp.130-137
    • /
    • 2021
  • Purpose: The various suture techniques can be utilized in order to maximize the keratinized tissue healing around dental implants. The aim of this study is to compare the soft tissue healing pattern between two different suture techniques after implant placement. Materials and Methods: 15 patients with 18 implants were enrolled in this study. Simple implant placement without any additional bone graft was performed. Two different suture techniques were used to tug in the mobilized flap near the healing abutment after paramarginal flap design. Digital intraoral scan was performed at baseline, post-operation, stitch out, and 3 months after operation. The scan data were aligned using multiple points such as cusp, fossa of adjacent teeth, and/or healing abutment. After subtracting scan data at baseline with other time-point results, closed space indicating volume increment of peri-implant mucosa was selected. The volume of the close space was measured in mm3. The volume between two suture techniques at three time-points was compared using nonparametric rank-based analysis. Results: Healing was uneventful in both groups. Both suture technique groups showed increased soft tissue volume immediately after surgery. The amount of volume increment significantly decreased after 3 months (P < 0.001). Flap folding suture group showed higher median of volume increment than interrupted suture group after 3 months without any statistical significance (P > 0.05). Conclusion: After paramarginal flap reflection, the raised flaps stabilized by flap folding suture showed relatively higher volume maintenance after 3-month healing period. However, further studies are warranted.

Utility Evaluation of Supportive Devices for Interventional Lower Extremity Angiography (인터벤션 하지 혈관조영검사를 위한 보조기구의 유용성 평가)

  • Kong, Chang gi;Song, Jong Nam;Jeong, Moon Taek;Han, Jae Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.613-621
    • /
    • 2019
  • The purpose of this study is to evaluate the effectiveness of supportive devices which are for minimizing the patient's movement during lower extremity angiography and to verify image quality of phantom by analyzing of Mask image, DSA image and Roadmap image into SNR and CNR. As a result of comparing SNR with CNR of mask image obtained by DSA technique using the phantom alone and phantom placed on the supportive devices, there was no significant difference between about 0~0.06 for SNR and about 0~0.003 for CNR. The study showed about 0.11~0.35 for SNR and 0.016~0.031 for CNR of DSA imaging by DSA technique about only water phantom of the blood vessel model and the water phantom placed on the device. Analyzing SNR and CNR of Roadmap technique about water phantom on the auxiliary device (hardboard paper, pomax, polycarbonate, acrylic) and water phantom alone, there was no significant difference between 0.02~0.05 for SNR and 0.002~0.004 for CNR. In conclusion, there was no significant difference on image quality by using supportive devices made by hardboard paper, pomax, polycarbonate or acryl regardless of whether using supportive devices or not. Supportive devices to minimize of the patient's movement may reduce the total amount of contrast, exam-time, radiation exposure and eliminate risk factors during angiogram. Supportive devices made by hardboard paper can be applied easily during angiogram due to advantages of reasonable price and simple processing. It is considered that will be useful to consider cost efficiency and types of materials and their properties in accordance with purpose and method of the study when the operator makes and uses supportive devices.