• Title/Summary/Keyword: Digital subtraction

Search Result 205, Processing Time 0.029 seconds

Speech Recognition in the Car Noise Environment (자동차 소음 환경에서 음성 인식)

  • 김완구;차일환;윤대희
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.30B no.2
    • /
    • pp.51-58
    • /
    • 1993
  • This paper describes the development of a speaker-dependent isolated word recognizer as applied to voice dialing in a car noise environment. for this purpose, several methods to improve performance under such condition are evaluated using database collected in a small car moving at 100km/h The main features of the recognizer are as follow: The endpoint detection error can be reduced by using the magnitude of the signal which is inverse filtered by the AR model of the background noise, and it can be compensated by using variants of the DTW algorithm. To remove the noise, an autocorrelation subtraction method is used with the constraint that residual energy obtainable by linear predictive analysis should be positive. By using the noise rubust distance measure, distortion of the feature vector is minimized. The speech recognizer is implemented using the Motorola DSP56001(24-bit general purpose digital signal processor). The recognition database is composed of 50 Korean names spoken by 3 male speakers. The recognition error rate of the system is reduced to 4.3% using a single reference pattern for each word and 1.5% using 2 reference patterns for each word.

  • PDF

삼차원 조영증강 자기공명혈관조영술을 이용한 내경동맥 협착에 대한 평가: 디지털감산혈관조영술과의 비교

  • 한동복;최충곤;박지강;이정현;이호규
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.139-139
    • /
    • 2001
  • 목적: 경동맥 분지부에서 내경동맥 협착에 대한 평가에 있어서 삼차원 조영증강 자기공명혈관조영술의 정확도를 알아보고자 하였다. 대상 및 방법: 삼차원 조영증강 자기공명혈관조영술(3D Contrast-enhanced MRA)과 디지털감산혈관 조영술(Digital Subtraction Angiography, DSA)을 모두 시행한 35명의 환자, 68예의 내경동맥을 분석하였다. 내경동맥 협착의 측정은 North American Symptomatic Carotid Endarterectom Trial (NASCET) 기준을 이용하였다. 두 가지 검사에서 협착 정도를 경도(mild:0-29%), 중등도(moderate:30-69%), 심한 협착(severe:70-99%), 완전 폐색(occlusion:100%)등 네 그룹으로 나누었다. 두 명의 관찰자(A,B)가 DSA에서 측정한 협착 정도를 기준으로 3D Contrast-enhanced MRA에서 측정한 협착 정도를 비교하여 두 검사 방법간에 판정 일치율과 차이점을 분석하였다.

  • PDF

Diagnosis of Subclavian Steal: Contrast Enhanced 3D MR Angiography vs 2D TOF

  • 이호규;김건언;최중곤;서대철
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.136-136
    • /
    • 2001
  • Purpose: Subclavian steal refers to the retrograde flow of blood in a vertebral artery that supplies t ipsilateral shoulder and arm caused by proximal subclavian artery stenosis or occlusion. T purpose of this exhibit is to demonstrate MR findings of subclavian steal on contrast-enhanc 3D (CE 3DMRA) and 2D TOF MR angiography. Method: Four patients(men 3 and women 1, age: 28-78years) with subclavian steal obtained both CE 3DMRA and digital subtraction angiography(DSA) including subclavian arterie Sequential imaging was undertaken during first pass after double dose of Gd-DTPA (0 mM/kg) Injected by a power injector. Coronal source images were obtained with coronal D-fast low angle shot sequence(TR/TE/flip angle=3.8/l.3/35, acquisition time= 10sec/one measurement). Precontrast imaging was subtracted from enhanced images and maximu intensity projection was done. 2D time-of-flight MR angiography(2D TOF) of the carot bifurcation was added in all cases with post-saturation. All studies were review retrospectively.

  • PDF

Endovascular Treatment Using Graft-Stent for Pseudoaneurysm of the Cavernous Internal Carotid Artery

  • Ko, Jun-Kyeung;Lee, Tae-Hong;Lee, Jae-Il;Choi, Chang-Hwa
    • Journal of Korean Neurosurgical Society
    • /
    • v.50 no.1
    • /
    • pp.48-50
    • /
    • 2011
  • A 57-year-old man presented with a 2-day history of left oculomotor palsy. Digital subtraction angiography revealed a pseudoaneurysm of the left cavernous internal carotid artery (ICA) measuring $37{\times}32mm$. The pseudoaneurysm was treated with a balloon expandable graft-stent to occlude the aneurysmal neck and preserve the parent artery. A post-procedure angiogram confirmed normal patency of the ICA and complete sealing of the aneurysmal neck with no opacification of the sac. After the procedure, the oculomotor palsy improved gradually, and had completely resolved 3 months after the procedure. A graft-stent can be an effective treatment for a pseudoaneurysm of the cavernous ICA with preservation of the parent artery.

A Study on 2 -Dimensional Sound Source Tracking System II (2차원적 음원추적에 관한 연구 II)

  • 문성배;전승환
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 1998.04a
    • /
    • pp.156-162
    • /
    • 1998
  • The whistle is a very important information source for the safety navigation under foggy weather. But navigator has no concern about this , because it must be achieved by human hearing sense and considered as a vague signal. If the range and relative bearing of signa source can be detected automatically, it would be very useful system for preventing marine casualties making a lot of economic loss and environment pollution. Before the algorithm of 2-dimensinal sound source tracking system was reported . This paper describes the method that can obtain thetime lag between three signas and the theory of cross-correlation analysis and subtraction method for cauculating the time lag by using the digital signal data sequences. And a series of experiments were carried out for various position of sound source in the range from 200m to 530cm.

  • PDF

Supraceliac Aorta Bypass Surgery For Juxtarenal Aortic Occlussive Disease -2 Cases - (신장근접 대동맥 폐색증의 상복강대동맥 우회술)

  • 오중환
    • Journal of Chest Surgery
    • /
    • v.25 no.1
    • /
    • pp.105-111
    • /
    • 1992
  • Total atherosclerotic obstruction of the juxtarenal abdominal aorta is a relatively rarely encountered form of atherosclerotic vascsular disease, accounting for less than 5% of all arterial obstrutive disease. We have encountered two patients with such lesions, both of whom were admitted for intermittent claudication of the lower extremities and symptoms of vascular ischemia. Digital subtraction angiography[DSA] was performed on both patients, the results of which revealed total obstruction of the aorta just inferior to the renal arteries without involving the latter. Operative technique involved the use of the sup-raceliac aorta as the site of proximal anastomosis of aortofemoral bypass followed by a fem-orofemoral bypass graft with Smm sized Woven Dacron[Vascutek] through a subcutaneous tunnel within the retroperitoneal space. Both patients experienced restoration of blood flow distal to the obstruction postoperatively without any complications, and OPD follow-up one month postoperatively and postoperative DSA showed evidence of continued graft patency with persistent symptomatic improvement.

  • PDF

A Study on 2-Dimensional Sound Source Tracking System II (2차원적 음원추적에 관한 연구 II)

  • 문성배;전승환
    • Journal of the Korean Institute of Navigation
    • /
    • v.22 no.4
    • /
    • pp.31-36
    • /
    • 1998
  • The whistle is a very important information source for the safety navigation under foggy weather. But navigator has no concern about this, because it must be achived by human hearing sense and considered as a vague signal. If the range and relative bearing of signal source can be detected automatically, it would be very useful system for preventing marine casualties making a lot of economic loss and environment pollution. Before the algorithm of 2-dimensional sound source tracking system was reported. This paper describes the method that can obtain the time lag between three signals and the theory of cross-correlation analysis and subtraction method for cauculating the time lag by using the digital signal data sequences. And a series of experiments were carried out for various position of sound source in the range from 200cm to 530cm. As a result, we have recognized that sound source tracking system is possible to the sea field with improvement of position error.

  • PDF

Feature Extraction System for Land Cover Changes Based on Segmentation

  • Jung, Myung-Hee;Yun, Eui-Jung
    • Korean Journal of Remote Sensing
    • /
    • v.20 no.3
    • /
    • pp.207-214
    • /
    • 2004
  • This study focused on providing a methodology to utilize temporal information obtained from remotely sensed data for monitoring a wide variety of targets on the earth's surface. Generally, a methodology in understanding of global changes is composed of mapping, quantifying, and monitoring changes in the physical characteristics of land cover. The selected processing and analysis technique affects the quality of the obtained information. In this research, feature extraction methodology is proposed based on segmentation. It requires a series of processing of multitempotal images: preprocessing of geometric and radiometric correction, image subtraction/thresholding technique, and segmentation/thresholding. It results in the mapping of the change-detected areas. Here, the appropriate methods are studied for each step and especially, in segmentation process, a method to delineate the exact boundaries of features is investigated in multiresolution framework to reduce computational complexity for multitemporal images of large size.

Magnetization Transfer Contrast Angiography for Organized Thrombosed Intracranial Aneurysm in TOF MR Angiography: a Case Report

  • Kang, Dong-Hun;Lee, Hui Joong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.4
    • /
    • pp.266-271
    • /
    • 2018
  • A 66-year-old woman was referred for treatment of incidental detection of two intracranial aneurysms. Time-of-flight MR angiography (TOF MRA) revealed two aneurysms at the M1 segment of the right middle cerebral artery, and clinoid segment of left internal carotid artery, respectively. On digital subtraction angiography, there was a saccular aneurysm on the left internal carotid artery, but the other aneurysm was not detected on the right middle cerebral artery. Based on comprehensive review of imaging findings, organized thrombosed aneurysm was judged as the most likely diagnosis. In the presented report, magnetization transfer (MT) pulse to TOF MRA was used, to differentiate aneurysm-mimicking lesion on TOF MRA. We report that MT technique could be effective in differentiating true aneurysm, from possible T1 high signal artifact on TOF MRA.

Spontaneous Intracranial Vertebral Artery Dissection in a 2-Year-Old Child Diagnosed with High-Resolution MRI: a Case Report

  • Heo, Subin;Han, Miran;Kim, Sung Hwan;Choi, Jin Wook
    • Investigative Magnetic Resonance Imaging
    • /
    • v.23 no.3
    • /
    • pp.259-263
    • /
    • 2019
  • Although many imaging modalities can play some roles in the diagnosis of vertebral artery dissection (VAD), digital subtraction angiography (DSA) remains the gold standard method, with the highest detection rate and ability to assist in planning for endovascular treatment. However, this tool is often avoided in children because its invasive nature and it exposes them to radiation. High resolution magnetic resonance imaging (HR-MRI) have been suggested to be a reliable and non-invasive alternative, but it has never been discussed in children in whom vertebral artery dissection is a rare condition. In this report, we evaluate a case of a 2-year-old child who initially presented with cerebellar symptoms, and was early diagnosed with vertebral artery dissection using HR- MRI and was successfully treated.