• Title/Summary/Keyword: Digital straightening

Search Result 5, Processing Time 0.022 seconds

Part tolerancing through multicale defect analysis

  • Petitcuenot, Mathieu;Anselmetti, Bernard
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.17 no.1
    • /
    • pp.109-119
    • /
    • 2016
  • When manufactured parts undergo large deformations during the manufacturing process, the global specifications of a part based on the concept of tolerance zone defined in the ISO 1101 standard [1] enable one to control the part's global defects. However, the extent of this tolerance zone is too large when the objective is to minimize local defects, such as hollows and bumps. Therefore, it is necessary to address local defects and global defects separately. This paper refers to the ISO 10579 standard [2] for flexible parts, which enables us to define a stressed state in order to measure the part by straightening it to simulate its position in the mechanism. The originality of this approach is that the straightening operation is performed numerically by calculating the displacement of a cloud of points. The results lead to a quantification of the global defects through various simple models and enable us to extract local defects. The outcome is an acceptable tolerance solution. The procedure is first developed for the simple example of a steel bar with a rectangular cross section, then applied to an industrial case involving a complex 3D surface of a turbine blade. The specification is described through ISO standards both in the free state and in the straightened state.

Identifying Riparian Water Landscape Change Detection Using Digital Photogrammetry Technique

  • Ahn Seung-mahn;Lee Kyoo-seock
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.25-27
    • /
    • 2004
  • Han River water landscape changes between 1966 and 2002 were detected by interpreting IKONOS images, aerial photographs. Digital photogrammetry technique was used in this process. Most of water landscape change are disappearance of sandbars and meandering streams in 1966. It is mainly due to the stream straightening for housing site development.

  • PDF

A Comparative Study on Distortion Correction Algorithms for Digital Cadastral Maps (전산화 지적도의 왜곡 최소화 알고리즘 비교연구)

  • 김병국;정동훈;김해명
    • Spatial Information Research
    • /
    • v.11 no.4
    • /
    • pp.421-437
    • /
    • 2003
  • In order to calculate the position of parcel boundary points, the area of the Parcel, and the length of the parcel boundary lines using a digitalized cadastral map or maps, the distortion of the map has to be corrected. The correction methods, such as the method of 2D affine transformation using 4 comer points of the edge lines, the method of tessellation into 9 subregions, the method of using the original surveying sheets, and the method of straightening the 4 edge lines, have been developed. In this Paper, the four methods were programed and applied to some sample cadastral maps and the correction accuracies were obtained and analysed. No method could prefectly correct the distortions because the distortions were irregular throughout the maps. However, it is found that tile method of straightening the 4 edge lines is the one which can minimize the distortions when the method is applied after applying the 2D projective transformation on the maps using the 4 comer points of the edges.

  • PDF

A Study on the Landscape Arrangement Simulation System for Small Streams (소하천 경관정비 모의시스템에 관한 연구)

  • 김선주;윤경섭;이광야;박성삼
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.39 no.5
    • /
    • pp.86-96
    • /
    • 1997
  • The arrangement of small streams in rural area, in the past times, attached importance to the prevention of flood damage through the straightening and lining of streams. Recently, the way of small stream arrangement is introducing the idea of water friendly environment or friendly space. As a result, there has been much concern with water favorable river management model which may lead to control flood. However, it is very difficult to develop a model applicable to all types of rivers, since each river has different flow velocity, flow amount and unique ecological characteristics. In this study, photo processing technique, one of landscape simulation methods, has been adopted because it helps to visually express and comprehensively evaluate pre and post scenery and easily applicable. Some important guideline and technique for the planning of small stream landscape arrangement are mentioned in this study. The simulation system for acquiring water favorable space and arranging landscapes needs to develop database which can forecast various types of landscape. It may also be used for the bases of planning and designing river environment arrangement. Computer aided image processing system enables to make selective planning in river environment arrangement. It may also enables to develop the methods for river environment development, ecology conservation, and multipurpose space utilization. Moreover, it makes economic river arrangement by applying river environment arrangement methods relevant to geographical characteristics. There are some limitations in this study, such as shortage of exact investigation on the stream direction and velocity in landscape arrangement. Continuous monitoring and research may be required to develop techniques through the application of computer graphics and digital image processing.

  • PDF

Comparative Study on the Ability of Instruments to Maintain Original Canal Curvature of Continuous rotary System and Single File System (Continuous rotary system과 single file system의 만곡 근관 형태 유지능에 대한 비교 연구)

  • Park, Sang-Hee;Kim, Deok-Joong;Song, Yong-Beom;Lee, Hye-Yun;Kim, Hyoung-Sun;Lee, Kwang-Won;Yu, Mi-Kyung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.4
    • /
    • pp.371-383
    • /
    • 2012
  • Shaping the root canal system to maintain original canal curvature is essential to clinical success in endodontic treatment. Opposed to most root canals that are curved, endodontic instruments are made from straight metal blanks. They have a tendency of straightening the root canal during preparation and frequently result in procedural errors. A new treatment method to maintain original canal curvature during shaping has been introduced for preventing procedural errors. The aim of this study was to compare the ability of instruments to maintain original canal curvature of continuous rotary system and single file system. Thirty ISO 15, 0.02 taper, Endo Training Blocks(Dentsplay Maillefer) were used. Specimens were assigned to 1 of 3 groups for shaping: specimens in group 1 were shaped with ProFile #20/.06 at the WL. Specimens in group 2 were shaped with Mtwo #35/.04 at the WL. Specimens in group 3 were shaped with WaveOne Primary reciprocating files at the WL after the glide path was achieved with PathFile. Pre- and postinstrumentation digital images were superimposed and processed with Matlab r2010b(The MathWorks Inc, Natick, MA) software to analyze the curvature-radius ratio(CRr), representing canal curvature modification. Data for comparison on the ability of instruments to maintain original canal curvature depending on each Ni-Ti file were analyzed with 1-way ANOVA(P<.05). Data for comparison on the ability of instruments to maintain original canal curvature depending on each Ni-Ti file system were analyzed with independent t-test(P<.05). A statistically significant difference(P<0.05) was noted on each Ni-Ti file. ProFile and WaveOne instrumentations maintained the original canal curvature significantly better(P<0.05) than Mtwo file. There were no significant difference(P>0.05) between continuous rotary system and single file system. Under the conditions of this study, ProFile and WaveOne instruments maintained the original curvature significantly better than Mtwo file and were less modification of the canal curvature compared. There was no significant difference between continuous rotary system and single file system in shaping of simulated canals. As clinical practitioners, it may be advantages to use hybrid approach when root canal shapes depending on the design and usage of Ni-Ti files.