• 제목/요약/키워드: Digital reference wave

검색결과 27건 처리시간 0.021초

Experimental Study of Two-step Phase-shifting Digital Holography based on the Calculated Intensity of a Reference Wave

  • Li, Jun;Pan, Yang Yang;Li, Jiao sheng;Li, Rong;Zheng, Tao
    • Journal of the Optical Society of Korea
    • /
    • 제18권3호
    • /
    • pp.230-235
    • /
    • 2014
  • Two-step quadrature phase-shifting digital holography based on the calculated intensity of a reference wave is proposed. In the Mach-Zehnder interferometer (MZI) architecture, the method only records two quadrature-phase holograms, without reference-wave intensity or object-wave intensity measurement, to perform object recoding and reconstruction. When the reference-wave intensity is calculated from the 2D correlation coefficient (CC) method that we presented, the clear reconstruction image can be obtained by some specific algorithm. Its feasibility and validity were verified by a series of experiments with 2D objects and 3D objects. The presented method will be widely used in real-time or dynamic digital holography applications.

Rough surface characterization using off-axis digital holographic microscopy compensated with self-hologram rotation

  • Ibrahim, Dahi Ghareab Abdelsalam
    • Current Applied Physics
    • /
    • 제18권11호
    • /
    • pp.1261-1267
    • /
    • 2018
  • In this paper, an off-axis digital holographic microscopy compensated with self-hologram rotation is presented. The process is implemented via subtracting the unwrapped phase maps of the off-axis parabolic hologram and its rotation $180^{\circ}$ to eliminate the tilt induced by the angle between the spherical object wave O and the plane reference wave R. Merit of the proposed method is that it can be done without prior knowledge of physical parameters and hence can reconstruct a parabolic hologram of $1024{\times}768$ pixels within tens of milliseconds since it doesn't require a digital reference wave. The method is applied to characterize rough gold bumps and the obtained results were compared with those extracted from the conventional reconstruction method. The comparison showed that the proposed method can characterize rough surfaces with excellent contrast and in realtime. Merit of the proposed method is that it can be used for monitoring smaller biological cells and micro-fluidic devices.

Efficient and Exact Extraction of the Object Wave in Off-axis Digital Holography

  • Jang, Jin;Jeon, Jun Woo;Kim, Jin Sub;Joo, Ki-Nam
    • Current Optics and Photonics
    • /
    • 제2권6호
    • /
    • pp.547-553
    • /
    • 2018
  • In this paper, a new method for spatial filtering in digital holography is proposed and verified by simulations compared to conventional methods. The new method is based on the simultaneous acquisition of two digital holograms, which can be separated by distinct spatial modulation, in a single image. Two holograms are generated by two reference waves, which have different spatial modulation orientations. Then, the overlapping region between the DC term and the object wave in the first hologram can be replaced with a less-overlapping region of the object wave in the second hologram because the whole image contains two holograms where the same objective wave has been recorded. In the simulation results, it is confirmed that the reconstructed image by the new method has better quality than for the original method.

위상천이 디지털 홀로그래피를 이용한 3차원 상대 거리 측정 (Three-dimensional relative-distance measurement by use of the phase-shifting digital holography)

  • 김현;이연호
    • 한국광학회지
    • /
    • 제14권2호
    • /
    • pp.200-207
    • /
    • 2003
  • 본 논문에서는 기존의 위상천이 디지털 홀로그래피에서 기준빔으로 사용되는 평면파 대신 보다 일반적인 구면파를 이용하여 3차원 공간상에 위치한 두 물체점들 사이의 상대적인 거리를 측정하는 새로운 시스템 및 알고리듬을 제안한다. 본 논문에서는 이러한 시스템에 대한 모의실험 및 광학실험을 실시하였다. 이러한 시스템에서는 홀로그램 기록에 사용된 기준빔의 정확한 정보를 알고 있지 않더라도 3차원 공간상의 두 물체점들 사이의 상대적인 거리를 정확하게 측정할 수 있다. 본 논문에서는 광학실험을 통하여 약 300 cm 거리에서 서로 0.5 cm 떨어진 두 물체점들 사이의 상대적인 거리를 10% 미만의 오차로 측정하였다.

GPGPU기반의 디지털 홀로그램 콘텐츠의 고속 생성 기법 (High-Speed Generation Technique of Digital holographic Contents based on GPGPU)

  • 이윤혁;김동욱;서영호
    • 디지털산업정보학회논문지
    • /
    • 제9권1호
    • /
    • pp.151-163
    • /
    • 2013
  • Recently the attention on digital hologram that is regarded as to be the final goal of the 3-dimensional video technology has been increased. Digital hologram is calculated by modeling the interference phenomenon between an object wave and a reference wave. The modeling for digital holograms is called by computer generated hologram (CGH) Generally, CGH requires a very large amount of calculation. So if holograms are generated in real time, high-speed method should be needed. In this paper, we analyzed CGH equation, optimized it for mapping general purpose graphic processing unit (GPGPU), and proposed a optimized CGH calculation technique for GPGPU by resource allocation and various experiments which include block size changing, memory selection, and hologram tiling. The implemented results showed that a digital hologram that has $1,024{\times}1,024$ resolution can be generated during approximately 24ms, using 1K point clouds. In the experiment, we used two GTX 580 GPGPU of nVidia Inc.

New Configuration of a PLDRO with an Interconnected Dual PLL Structure for K-Band Application

  • Jeon, Yuseok;Bang, Sungil
    • Journal of electromagnetic engineering and science
    • /
    • 제17권3호
    • /
    • pp.138-146
    • /
    • 2017
  • A phase-locked dielectric resonator oscillator (PLDRO) is an essential component of millimeter-wave communication, in which phase noise is critical for satisfactory performance. The general structure of a PLDRO typically includes a dual loop of digital phase-locked loop (PLL) and analog PLL. A dual-loop PLDRO structure is generally used. The digital PLL generates an internal voltage controlled crystal oscillator (VCXO) frequency locked to an external reference frequency, and the analog PLL loop generates a DRO frequency locked to an internal VCXO frequency. A dual loop is used to ease the phase-locked frequency by using an internal VCXO. However, some of the output frequencies in each PLL structure worsen the phase noise because of the N divider ratio increase in the digital phase-locked loop integrated circuit. This study examines the design aspects of an interconnected PLL structure. In the proposed structure, the voltage tuning; which uses a varactor diode for the phase tracking of VCXO to match with the external reference) port of the VCXO in the digital PLL is controlled by one output port of the frequency divider in the analog PLL. We compare the proposed scheme with a typical PLDRO in terms of phase noise to show that the proposed structure has no performance degradation.

Elemental Image Synthesis for Integral Imaging Using Phase-shifting Digital Holography

  • Jeong, Min-Ok;Kim, Nam;Park, Jae-Hyeung
    • Journal of the Optical Society of Korea
    • /
    • 제12권4호
    • /
    • pp.275-280
    • /
    • 2008
  • We propose a method generating elemental images for the integral imaging using 4-step phaseshifting digital holography. Phase shifting digital holography is a way recording the digital hologram by changing the phase of the reference beam and extracting the complex field of the object beam. Since all 3D information is captured by phase-shifting digital holography, the elemental images for any specifications of the lens array can be generated from single phase-shifting digital holography. In experiment, phase-shifting is achieved by rotating half- and quarter- wave plates and the resultant interference patterns are captured by a $3272{\times}2469$ pixel CCD camera with $27{\mu}m{\times}27{\mu}m$ pixel size.

AMDF를 이용한 Digital Sonar 의 반사신호처리에 관한 연구 (On the reflected signal processing of Digital Sonar using the AMDF)

  • 홍우영
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1984년도 추계학술발표회 논문집
    • /
    • pp.91-95
    • /
    • 1984
  • Because of layer and scattering in the ocean, there are some problem in algorithm currently used for the recognition of targets. Those are time delay of processing and circuit design. The simple method of detecting direct sound wave in noise caused by time delay is proposed-recognized, estimated, and then direcxt sound wave is reconstructed by the AMDF and $\mu$-processor. 2KHz, 4KHz, 8KHz, 12KHz, 16KHz sound waves are used in experiment. To obtain a reference signal, anechoic water tank is used is processing and aluminium water tank used instead of real ocean. As a result, there are a few errors which caused by anechoic water tank error, decreasing of frequency make errors. Possibility of application to Sonar Signal Processing is proved.

  • PDF

Phase and Amplitude Drift Research of Millimeter Wave Band Local Oscillator System

  • Lee, Chang-Hoon;Je, Do-Heung;Kim, Kwang-Dong;Sohn, Bong-Won
    • Journal of Astronomy and Space Sciences
    • /
    • 제27권2호
    • /
    • pp.145-152
    • /
    • 2010
  • In this paper, we developed a local oscillator (LO) system of millimeter wave band receiver for radio astronomy observation. We measured the phase and amplitude drift stability of this LO system. The voltage control oscillator (VCO) of this LO system use the 3 mm band Gunn oscillator. We developed the digital phase locked loop (DPLL) module for the LO PLL function that can be computer-controlled. To verify the performance, we measured the output frequency/power and the phase/amplitude drift stability of the developed module and the commercial PLL module, respectively. We show the good performance of the LO system based on the developed PLL module from the measured data analysis. The test results and discussion will be useful tutorial reference to design the LO system for very long baseline interferometry (VLBI) receiver and single dish radio astronomy receiver at the 3 mm frequency band.

Stimulus Artifact Suppression Using the Stimulation Synchronous Adaptive Impulse Correlated Filter for Surface EMG Application

  • Yeom, Ho-Jun;Park, Ho-Dong;Chang, Young-Hui;Park, Young-Chol;Lee, Kyoung-Joung
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권3호
    • /
    • pp.451-458
    • /
    • 2012
  • The voluntary EMG (vEMG) signal from electrically stimulated muscle is very useful for feedback control in functional electrical stimulation. However, the recorded EMG signal from surface electrodes has unwanted stimulation artifact and M-wave as well as vEMG. Here, we propose an event-synchronous adaptive digital filter for the suppression of stimulation artifact and M-wave in this application. The proposed method requires a simple experimental setup that does not require extra hardware connections to obtain the reference signals of adaptive digital filter. For evaluating the efficiency of this proposed method, the filter was tested and compared with a least square (LS) algorithm using previously measured data. We conclude that the cancellation of both primary and residual stimulation artifacts is enhanced with an event-synchronous adaptive digital filter and shows promise for clinical application to rehabilitate paretic limbs. Moreover because this algorithm is far simpler than the LS algorithm, it is portable and ready for real-time application.