• Title/Summary/Keyword: Digital picture

Search Result 375, Processing Time 0.026 seconds

The Study about the Positioning Block Artifact in Digital Radiography Environment (Digital Radiography 환경에서 Positioning Block Artifact에 관한 연구)

  • Kim, Byung-Ki;Choi, Jun-Gu;Lee, Jun;Lee, Min-Woo;Kim, Sun-Bae;Kim, Gyeong-Su
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.10 no.1
    • /
    • pp.13-19
    • /
    • 2008
  • Purpose : In sponge quality of the material in digital radiography environment coating because do position blocks two that do not become coating done positioning blocks two that do not become coating done positioning block and sponge quality of the material to testing bench image artifact's difference compare. Method of study : In digital radiography environment positioning block of different two products same sunshine or effect that image and positioning block artifact gents in image analyze. the target used positioning block 2 when examine hand, rib and examination condition did each differently according to used positioning block. reflex compared picture that do image and verify that examine first time. Result : 1. In sponge quality of the material coating in done product artifact appear. Did not appear in product that do not become coating. 2. Can know coating's existence, that artifact according to radish happens. 3. Quality of the material coating's existence, there was difference of slippage according to radish Conclusion : Quality of the material coating phenomenon that done positioning block thus, it may have to be considered that use after estimate degree that get in image.

  • PDF

PDA Transmission of Medical Images by CDMA (CDMA에 의한 의료영상의 PDA전송)

  • Lee, Myong-Ho;Lim, Jae-Dong;Ahn, Bung-Ju;Lee, Hwun-Jae;Lee, Sang-Bock
    • Journal of the Korean Society of Radiology
    • /
    • v.1 no.2
    • /
    • pp.13-22
    • /
    • 2007
  • The purpose of this study was to survey a development of the wireless transmission system of medical images for ubiquitous medicine. There have been many changes in medical equipments and medical record medical treatment and medical record within hospital and PACS(Picture Archiving Communication System) which is picture management system for patients can be typical cases. It is difficult to use these automated medical systems unless they are within hospital and in case of rapid image reading in the emergency cases or in absence of doctor, it is difficult to perform it immediately. The present study implemented an image transmission system using CDMA connection so that images in the server can be viewed at any time and in any place. Remote wireless diagnosis based on medical images using PDA is applicable to medical areas that require mobility, and the use of PDA can be an ideal alternative for point of care. The use of PDA enables prompt and accurate access to digital medical images, which in turn reduces medical accidents and improves the quality of medical services through high productivity and efficiency of medical practitioners' works. It also enables quick response to patients' demands and high-quality medical services and, consequently, patients' high satisfaction.

  • PDF

Effects on the thermal change of the Taeyon(L1) and the Chungbu(L1) area following acupuncture stimulation on Taeyon(L9) in man (태연(太淵)(L9)자침(刺鍼)이 태연(太淵)(L9)과 중부(中府)(L1)영역(領域)의 온도변화(溫度變化)에 미치는 영향(影響))

  • Kim, Young-ho;Song, Beom-Yong;Yook, Tae-han
    • Journal of Acupuncture Research
    • /
    • v.18 no.5
    • /
    • pp.77-91
    • /
    • 2001
  • Backgrounds and purpose : The acupuncture of oriental medicine is very important in treatments. Until now it was been researched according to the meridian and qi xue(氣血) phenomenon of oriental medicine's theory. Acupuncture will show more objective index to observe the meridian. And then, I studied the effects on the thermal change of the Taeyon($L_9$) and Chungbu($L_1$) following acupuncture stimulation. Objective and Methods : This study was performed from December 1999 to February 2000 on 60 healthy students. The objective was divided into two groups, those are the control group A(N=30) that no acupuncture stimulation, the group B(N=30) of acupuncture stimulation on Taeyon($L_9$). First, in the control group A, I took a picture Taeyon($L_9$) Chungbu($L_1$) Taenung($P_7$) Chondol($CV_{22}$) area for 30 men without any stimulation with the Digital Infrared Thermograph Imaging(D.I.T.l.) and did same area, 10min after. Second, in the acupuncture stimulation group B, we took a picture Taeyon($L_9$) Chungbu($L_1$) Taenung($P_7$) Chondol($CV_{22}$) area for 30 men without any stimulation with the Digital Infrared Th - ermograph Imaging(D.I.T.I.), and then stimulate acupuncture on Taeyon($L_9$) and took a picture same area, 10min after. Results : 1. In healthy men, average skin temperture on Taeyon($L_9$) area was lower than Chungbu($L_1$) area about $3.0^{\circ}C$, in the Lt. Taeyon($L_9$) and Chungbu($L_1$) area was lower than Rt. Taeyon($L_9$) and Chungbu($L_1$) area. 2. In the acupuncture stimulation group B, the skin temperature of both side Taeyon($L_9$) area showed the increase or decrease significantly. But both Taenung($P_7$) area did not showed significantly. 3. In the acupuncture stimulation group B, the skin temperature of both side Chungbu($L_1$) area showed the increase or decrease significantly. But both Chondol($CV_{22}$) area did not showed significantly. 4. The thermal changes of the area which is a meridian point in the Lung Meridian of the acupuncture stimulation group on Taeyon($L_9$) different from other Meridian with significantly change. Conclusion : The acupuncture stimulation on Taeyon($L_9$) affected the thermal change of the area which is a meridian point, in the Lung Meridian. And then I could relate these results with the existence of the meridian and meridian point. Thus, continuous thermographic study will be needed for the existence of the meridian and meridian point.

  • PDF

Implementation of the Audio CODEC for Digital Audio Broadcasting Service (디지털 오디오 방송 서비스를 위한 오디오 코덱의 구현)

  • 장대영;홍진우
    • Journal of Broadcast Engineering
    • /
    • v.6 no.1
    • /
    • pp.66-71
    • /
    • 2001
  • This paper Introduces an implementation of MPEG-2 AAC codec system for digital audio broadcasting. This system consists of the encoder and the decoder. This system includes MPEG-2 system multiplexing and demultiplexing modules for Interfacing to the ETRI-DAB system. Four DSPs are adopted for the encoder and three DSPs for 7he decoder. Each DSP Processes system control. 1/0 control, audio signal processing. multiplexing and demultiplexing. This Paper also discusses some near future estimations relaxed to the DAB system and it\`s services. Currently a stereo audio codec is available but multi-channel audio codec and MPEG-4 audio cosec wall be also Implemented.

  • PDF

Photographic Color Reproduction Based on Color Variation Characteristics of Digital Camera

  • Kim, Ui-Seong;Lee, Jong-Min;Kim, Yong-Min;Park, Ki-Tae;Moon, Young-Shik
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.5 no.11
    • /
    • pp.2160-2174
    • /
    • 2011
  • In this paper, a new technique for color reproduction based on color variation characteristics of digital camera under a dim light condition is proposed. Generally, photographers should adjust a camera exposure properly for obtaining an image with real color tone of subjects. Thus, in case of taking a picture under a dim light condition, the exposure time of a camera has to be relatively longer than the one under a bright light condition. Although images with real color tone of the subject are obtained, the images may get blurred due to the shaky hands of photographer holding the camera. In order to avoid the blur effect, an input image is captured from a camera set as a short exposure time under a dim light condition. Then we propose a method to reproduce color tone of the dim input image. To this end, color variation characteristics which represent color variations of a digital camera are first extracted by analyzing the Macbeth color checker images taken under various exposure values. Then, a color reproduction is performed by an estimation based on the color variation characteristics. Experimental results have shown that the proposed method has achieved better performance of color reproduction, compared with existing methods.

Implementation of the AAC Audio CODEC for Digital Audio Broadcasting (디지털 오디오 방송을 위한 AAC 오디오 코덱 구현)

  • 장대영;홍진우
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2000.11b
    • /
    • pp.43-48
    • /
    • 2000
  • This paper introduces MPEG-2 AAC codec system fur digital audio broadcasting. This system consists of encoder and decoder, and this system provides MPEG-2 system multiplexing and demultiplexing functions. Four DSPs are adopted fur encoder and three DSPs fur decoder. Each DSP processes system control, I/O control, and audio signal processing, multiplexing and demultiplexing. This paper also discusses about some near future estimations related to DAB system and services. And at the end of this paper describes about future development plans.

  • PDF

Body Size Measurement Method Using a Elastic Band and Digital Camera (엘라스틱 밴드와 디지털 카메라를 이용한 신체 치수 측정 방법)

  • Choi, Gi-Rak;Kim, Hyeon-seok;Lee, Jong-Hyeok
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.553-556
    • /
    • 2015
  • In almost all of the Hand-made suit plants, while garment cutters are hard to measure the body size by their own, they are not quick. And each of the individual's standard is vague, so it is hard to get a consistency. So it will give the customers some displeasure with the body contact. To improve this kind of problems, in this paper proposes a efficient way that is hard to measure by the general image processing technology to measure when you manufacture a Hand-made suit and measure a body size by wearing a elastic band that has a printed mark that has some information of length and taking a picture of the body by a digital camera.

  • PDF

Edge Profile Correction for Modulation Transfer Function on Digital X-ray Imaging System (디지털 의료영상에서 Edge method에 의한 Modulation Transfer Function 보정방법과 특이성)

  • Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.30 no.3
    • /
    • pp.251-257
    • /
    • 2007
  • Medical imaging zero-phase-sequence component in estimation for picture that is gotten that importance weight of digital device is increased day by day at the same time also so much important. Special quality about resolution uses Modulation Transfer Function by representative method to evaluate sharpness on important element in image quality. Get MTF converting slit, differentiating this making composition ESF edge method uses Excel by edge method in this study to be composition LSF get in fourier to informed measuring mean universally. Such method is considered that can help in principle grasping of step before make Program using C language as many as Matlab.

  • PDF

Methods of DICOM and Non-DICOM Interfacing for various Radiological Equipments with PACS (방사선 검사 관련 의료장비와 PACS 간의 연동을 위한 DICOM 및 Non-DICOM 인터페이스 방안)

  • Kim, H.C.
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.6 no.1
    • /
    • pp.51-64
    • /
    • 2003
  • This thesis describes the effective interfacing methods of PACS Modality based on the system installation andoperating experiences. PACS(Picture Archiving and Communication Systems) is a system for medical image archiving and communication using large storage device and high-speed network. The standard communication protocol of PACS is DICOM(Digital Imaging and Communication in Medicine) based on TCP/IP and point-to-point protocol. However, there are many Non-DICOM Modalities and DICOM Modalities having problems. First, we had interfaced almost modalities. Fuji CR, GE CT, MRI, Angio, Fluoro, Phillips Angio, Shimadzu Fluoro. Ultrasound PACS, with the main PACS in the Seoul S Hospital as large scale hospital. And we manipulated the intelligent image distribution and the CT. MRI Interfaces never experienced beforein the Anyang J Hospital and the Chungju C Hospital as mid or small scale hospital. Technically, we developed both the DICOM Interface and the Non-DICOM Interface. At the last, the DICOM Worklist and the DICOM Print Interface were implemented in the Seoul B Hospital, the Bucheon SJ Hospital and the Seoul K Hospital independently with PACS. The Oracle, Sybase and MS-SQL are used as database, and UNIX, Macintosh, MS Windows as operating systems. And the Visual C++ and UNIX C are the main programming tools. We have used UTP, coaxial and fiber optic cable under 10/100 mbps LAN for networking.

  • PDF

Methods of DICOM and Non-DICOM Interfacing for various Radiological Equipments with PACS (방사선 검사 관련 의료장비와 PACS 간의 연동을 위한 DICOM 및 Non-DICOM 인터페이스 방안)

  • Kim, Hyeon-Cheol
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.5 no.1
    • /
    • pp.46-63
    • /
    • 2002
  • This thesis describes the effective interfacing methods of PACS Modality based on the system installation and operating experiences. PACS(Picture Archiving and Communication Systems) is a system for medical image archiving and communication using large storage device and high-speed network. The standard communication protocol of PACS is DICOM(Digital Imaging and Communication in Medicine) based on TCP/IP and point-to-point protocol. However, there are many Non-DICOM Modalities and DICOM Modalities having problems. First, we had interfaced almost modalities, Fuji CR, GE CT, MRI, Angio, Fluoro, Phillips Angio, Shimadzu Fluoro, Ultrasound PACS, with the main PACS in the Seoul S Hospital as large scale hospital. And we manipulated the intelligent image distribution and the CT, MRI Interfaces never experienced before in the Anyang J Hospital and the Chungju C Hospital as mid or small scale hospital. Technically, we developed both the DICOM Interface and the Non-DICOM Interface. At the last, the DICOM Worklist and the DICOM Print Interface were implemented in the Seoul B Hospital, the Bucheon SJ Hospital and the Seoul K Hospital independently with PACS. The Oracle, Sybase and MS-SQL are used as database, and UNIX, Macintosh, MS Windows as operating systems. And the Visual C++ and UNIX C are the main programming tools. We have used UTP, coaxial and fiber optic Gable under 10/100 mbps LAN for networking.

  • PDF