• Title/Summary/Keyword: Digital mammography system

Search Result 30, Processing Time 0.023 seconds

Fuzzy Cluster Based Diagnosis System for Digital Mammogram (퍼지 클러스터 기반 디지털 유방 X선 영상 진단 시스템)

  • Rhee, Hyun-Sook;Yoon, Seok-Min
    • The KIPS Transactions:PartB
    • /
    • v.16B no.2
    • /
    • pp.165-172
    • /
    • 2009
  • According to the American Cancer Society, breast cancer is the second largest cause of cancer deaths and most frequently diagnosed cancer in women. The currently most popular method for early detection of breast cancer is the digital mammography. A mass or calcification lesion has been known as the most important clue for the diagnosis. In this paper, we propose a diagnosis approach based on fuzzy cluster knowledge base. We combine different two sources of feature data in duel OFUN-NET and produce the diagnosis result with possibility degree. We also present the experimental results on the dataset of mass and calcification lesions extracted from the public real world mammogram database DDSM. These results show higher classification accuracy than conventional methods and the feasibility as a decision supporting tool for diagnosis of digital mammogram.

Region-Growing Segmentation Algorithm for Rossless Image Compression to High-Resolution Medical Image (영역 성장 분할 기법을 이용한 무손실 영상 압축)

  • 박정선;김길중;전계록
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.3 no.1
    • /
    • pp.33-40
    • /
    • 2002
  • In this paper, we proposed a lossless compression algorithm of medical images which is essential technique in picture archive and communication system. Mammographic image and magnetic resonance image in among medical images used in this study, proposed a region growing segmentation algorithm for compression of these images. A proposed algorithm was partition by three sub region which error image, discontinuity index map, high order bit data from original image. And generated discontinuity index image data and error image which apply to a region growing algorithm are compressed using JBIG(Joint Bi-level Image experts Group) algorithm that is international hi-level image compression standard and proper image compression technique of gray code digital Images. The proposed lossless compression method resulted in, on the average, lossless compression to about 73.14% with a database of high-resolution digital mammography images. In comparison with direct coding by JBIG, JPEG, and Lempel-Ziv coding methods, the proposed method performed better by 3.7%, 7.9% and 23.6% on the database used.

  • PDF

Set Up and Operation for Medical Radiation Exposure Quality Control System of Health Promotion Center (건강검진센터의 의료방사선 피폭 품질관리 시스템 구축 운영 경험 보고)

  • Kim, Jung-Su;Jung, Hae-Kyoung;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.13-17
    • /
    • 2016
  • In this study, standard model of medical radiation dosage quality control system will be suggested and the useful of this system in clinical field will be reviewed. Radiation dosage information of modalities are gathered from digital imaging and communications in medicine(DICOM) standard data(such as DICOM dose SR and DICOM header) and stored in database. One CT scan, two digital radiography modalities and two mammography modalities in one health promotion center in Seoul are used to derive clinical data for one month. After 1 months research with 703 CT scans, the study shows CT $357.9mGy{\cdot}cm$ in abdomen and pelvic CT, $572.4mGy{\cdot}cm$ in brain without CT, $55.9mGy{\cdot}cm$ in calcium score/heart CT, screening CT at $54mGy{\cdot}cm$ in chest screening CT(low dose screening CT scan), $284.99mGy{\cdot}cm$ in C-spine CT and $341.85mGy{\cdot}cm$ in L-spine CT as health promotion center reference level of each exam. And with 1955 digital radiography cases, it shows $274.0mGy{\cdot}cm2$ and for mammography 6.09 mGy is shown based on 536 cases. The use of medical radiation shall comply with the principles of justification and optimization. This quality management of medical radiation exposure must be performed in order to follow the principle. And the procedure to reduce the radiation exposure of patients and staff can be achieved through this. The results of this study can be applied as a useful tool to perform the quality control of medical radiation exposure.

Accuracy of Digital Breast Tomosynthesis for Detecting Breast Cancer in the Diagnostic Setting: A Systematic Review and Meta-Analysis

  • Min Jung Ko;Dong A Park;Sung Hyun Kim;Eun Sook Ko;Kyung Hwan Shin;Woosung Lim;Beom Seok Kwak;Jung Min Chang
    • Korean Journal of Radiology
    • /
    • v.22 no.8
    • /
    • pp.1240-1252
    • /
    • 2021
  • Objective: To compare the accuracy for detecting breast cancer in the diagnostic setting between the use of digital breast tomosynthesis (DBT), defined as DBT alone or combined DBT and digital mammography (DM), and the use of DM alone through a systematic review and meta-analysis. Materials and Methods: Ovid-MEDLINE, Ovid-Embase, Cochrane Library and five Korean local databases were searched for articles published until March 25, 2020. We selected studies that reported diagnostic accuracy in women who were recalled after screening or symptomatic. Study quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. A bivariate random effects model was used to estimate pooled sensitivity and specificity. We compared the diagnostic accuracy between DBT and DM alone using meta-regression and subgroup analyses by modality of intervention, country, existence of calcifications, breast density, Breast Imaging Reporting and Data System category threshold, study design, protocol for participant sampling, sample size, reason for diagnostic examination, and number of readers who interpreted the studies. Results: Twenty studies (n = 44513) that compared DBT and DM alone were included. The pooled sensitivity and specificity were 0.90 (95% confidence interval [CI] 0.86-0.93) and 0.90 (95% CI 0.84-0.94), respectively, for DBT, which were higher than 0.76 (95% CI 0.68-0.83) and 0.83 (95% CI 0.73-0.89), respectively, for DM alone (p < 0.001). The area under the summary receiver operating characteristics curve was 0.95 (95% CI 0.93-0.97) for DBT and 0.86 (95% CI 0.82-0.88) for DM alone. The higher sensitivity and specificity of DBT than DM alone were consistently noted in most subgroup and meta-regression analyses. Conclusion: Use of DBT was more accurate than DM alone for the diagnosis of breast cancer. Women with clinical symptoms or abnormal screening findings could be more effectively evaluated for breast cancer using DBT, which has a superior diagnostic performance compared to DM alone.

A Contrast Enhancement Method using the Contrast Measure in the Laplacian Pyramid for Digital Mammogram (디지털 맘모그램을 위한 라플라시안 피라미드에서 대비 척도를 이용한 대비 향상 방법)

  • Jeon, Geum-Sang;Lee, Won-Chang;Kim, Sang-Hee
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.15 no.2
    • /
    • pp.24-29
    • /
    • 2014
  • Digital mammography is the most common technique for the early detection of breast cancer. To diagnose the breast cancer in early stages and treat efficiently, many image enhancement methods have been developed. This paper presents a multi-scale contrast enhancement method in the Laplacian pyramid for the digital mammogram. The proposed method decomposes the image into the contrast measures by the Gaussian and Laplacian pyramid, and the pyramid coefficients of decomposed multi-resolution image are defined as the frequency limited local contrast measures by the ratio of high frequency components and low frequency components. The decomposed pyramid coefficients are modified by the contrast measure for enhancing the contrast, and the final enhanced image is obtained by the composition process of the pyramid using the modified coefficients. The proposed method is compared with other existing methods, and demonstrated to have quantitatively good performance in the contrast measure algorithm.

A Study on System Model of Clinical Specialist in Radiologic Technology (전문방사선사 제도의 개발에 관한 연구)

  • Choi, Jong-Hak;Kim, You-Hyun;Kang, Hee-Doo;Oh, Moon-Kyu;Kim, Byung-Do;Han, Seung-Hee
    • Journal of radiological science and technology
    • /
    • v.23 no.1
    • /
    • pp.63-76
    • /
    • 2000
  • License system of radiologic technologists has been started since 1965 in Korea. This study is to explore directions on radiotechnologists' license system classified by subspecialty. For this purpose, the authors surveyed on radiotechnologists' license system classified by subspecialty, with the subject related to radiotechnologic societies. Additionally, data on qualification and license system associated with medical and health care field were collected. The results are as follows. 1. The main body for subspecialty system for radiologic technologists should be the Korea Radiologic Technologists Association and the Association should maintain a close cooperation with radiotechnologic societies. 2. A radiologic technologist should be a basic role once they pass the license examination. In addition, they can get a special qualification by subspecialty in radiologic technology. 3. Radiotechnologists' license system classified by subspecialty will be keep priorities in order and done systematically. Execution order is as follows ; This study proposes that radiotechnologists responsible for ultrasonography, computed tomography(CT), magnetic resonance imaging(MRI) and security management be started for the first stage. For the second stage, radiotechnologists for mammography, angio-cardiography, digital imaging, maxillo-facial and dental radiography, nuclear medicine, radio-therapeutic field should be in force. 4. Professional education course(basic and intensive) and clinical training program have to be made for the eligibility of radiotechnologists' license system classified by subspecialty. 5. Eligibility system of radiotechnologists' license system classified by subspecialty(non-government or government) has to be made. Further more, inquiry commission to investigate eligibility for radiotechnologists' license system should be established.

  • PDF

A Study of Various Filter Setups with FBP Reconstruction for Digital Breast Tomosynthesis (디지털 유방단층영상합성법의 FBP 알고리즘 적용을 위한 다양한 필터 조합에 대한 연구)

  • Lee, Haeng-Hwa;Kim, Ye-Seul;Lee, Youngjin;Choi, Sunghoon;Lee, Seungwan;Park, Hye-Suk;Kim, Hee-Joung;Choi, Jae-Gu;Choi, Young-Wook
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.271-280
    • /
    • 2014
  • Recently, digital breast tomosynthesis (DBT) has been investigated to overcome the limitation of conventional mammography for overlapping anatomical structures and high patient dose with cone-beam computed tomography (CBCT). However incomplete sampling due to limited angle leads to interference on the neighboring slices. Many studies have investigated to reduce artifacts such as interference. Moreover, appropriate filters for tomosynthesis have been researched to solve artifacts resulted from incomplete sampling. The primary purpose of this study is finding appropriate filter scheme with FBP reconstruction for DBT system to reduce artifacts. In this study, we investigated characteristics of various filter schemes with simulation and prototype digital breast tomosynthesis under same acquisition parameters and conditions. We evaluated artifacts and noise with profiles and COV (coefficinet of variation) to study characteristic of filter. As a result, the noise with parameter 0.25 of Spectral filter reduced by 10% in comparison to that with only Ramp-lak filter. Because unbalance of information reduced with decreasing B of Slice thickness filter, artifacts caused by incomplete sampling reduced. In conclusion, we confirmed basic characteristics of filter operations and improvement of image quality by appropriate filter scheme. The results of this study can be utilized as base in research and development of DBT system by providing information that is about noise and artifacts depend on various filter schemes.

Convergence of the Image Evaluation by BI-RADS Classification in Accordance with Algorithms in DR Mammography (디지털 유방촬영술에서 BI-RADS의 구분에 따른 알고리즘별 영상의 융복합적 평가)

  • Lee, Mi-Hwa
    • Journal of Digital Convergence
    • /
    • v.13 no.9
    • /
    • pp.489-495
    • /
    • 2015
  • Image availability evaluated by the degree of agreement and sensitive using the process improve visualization according to the Algorithm modification in Image Post-Processing. Reliability measured by the Breast Imaging Reporting and Data System. 172 patients visit same period divided by BI-RADS, category five stages, and contents of breast parenchyma into Calcification, Nodule and Mass. Evaluated the TE/PV image reliability, visualization sensitive, agreement of diagnosis. Convergence analysis was an in various fields. According to the result of this research, PV has higher sensitive and accuracy about lesions than TE visual and there is a difference insensitive by contents of breast parenchyma. Therefore, practical use of Algorithm Modification(Tissue Equalization: TE, Premium View: PV) is expected to improve more accurate, useful diagnosis, which has not been easy until now.

Effective Detective Quantum Efficiency (eDQE) Evaluation for the Influence of Focal Spot Size and Magnification on the Digital Radiography System (X-선관 초점 크기와 확대도에 따른 디지털 일반촬영 시스템의 유효검출양자효율 평가)

  • Kim, Ye-Seul;Park, Hye-Suk;Park, Su-Jin;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.23 no.1
    • /
    • pp.26-32
    • /
    • 2012
  • The magnification technique has recently become popular in bone radiography, mammography and other diagnostic examination. However, because of the finite size of X-ray focal spot, the magnification influences various imaging properties with resolution, noise and contrast. The purpose of study is to investigate the influence of magnification and focal spot size on digital imaging system using eDQE (effective detective quantum efficiency). Effective DQE is a metric reflecting overall system response including focal spot blur, magnification, scatter and grid response. The adult chest phantom employed in the Food and Drug Administration (FDA) was used to derive eDQE from eMTF (effective modulation transfer function), eNPS (effective noise power spectrum), scatter fraction and transmission fraction. According to results, spatial frequencies that eMTF is 10% with the magnification factor of 1.2, 1.4, 1.6, 1.8 and 2.0 are 2.76, 2.21, 1.78, 1.49 and 1.26 lp/mm respectively using small focal spot. The spatial frequencies that eMTF is 10% with the magnification factor of 1.2, 1.4, 1.6, 1.8 and 2.0 are 2.21, 1.66, 1.25, 0.93 and 0.73 lp/mm respectively using large focal spot. The eMTFs and eDQEs decreases with increasing magnification factor. Although there are no significant differences with focal spot size on eDQE (0), the eDQEs drops more sharply with large focal spot than small focal spot. The magnification imaging can enlarge the small size lesion and improve the contrast due to decrease of effective noise and scatter with air-gap effect. The enlargement of the image size can be helpful for visual detection of small image. However, focal spot blurring caused by finite size of focal spot shows more significant impact on spatial resolution than the improvement of other metrics resulted by magnification effect. Based on these results, appropriate magnification factor and focal spot size should be established to perform magnification imaging with digital radiography system.

A Numerical Voxel Model for 3D-printed Uncompressed Breast Phantoms (3D 프린팅 비압박 유방 팬텀 제작을 위한 복셀 기반 수치 모델에 관한 연구)

  • Youn, Hanbean;Baek, Cheol Ha;Jeon, Hosang;Kim, Jinsung;Nam, Jiho;Lee, Jayoung;Lee, Juhye;Park, Dahl;Kim, Wontaek;Ki, Yongkan;Kim, Donghyun;Won, Jong Hun;Kim, Ho Kyung
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.3
    • /
    • pp.116-122
    • /
    • 2017
  • Physical breast phantoms would be useful for the development of a dedicated breast computed tomography (BCT) system and its optimization. While the conventional breast phantoms are available in compressed forms, which are appropriate for the mammography and digital tomosynthesis, however, the BCT requires phantoms in uncompressed forms. Although simple cylindrical plastic phantoms can be used for the development of the BCT system, they will not replace the roles of uncompressed phantoms describing breast anatomies for a better study of the BCT. In this study, we have designed a numerical voxel breast phantom accounting for the random nature of breast anatomies and applied it to the 3D printer to fabricate the uncompressed anthropomorphic breast phantom. The numerical voxel phantom mainly consists of the external skin and internal anatomies, including the ductal networks, the glandular tissues, the Cooper's ligaments, and the adipose tissues. The voxel phantom is then converted into a surface data in the STL file format by using the marching cube algorithm. Using the STL file, we obtain the skin and the glandular tissue from the 3D printer, and then assemble them. The uncompressed breast phantom is completed by filling the remaining space with oil, which mimics the adipose tissues. Since the breast phantom developed in this study is completely software-generated, we can create readily anthropomorphic phantoms accounting for diverse human breast anatomies.