STATEMENT OF PROBLEM: Interpoximal papilla could be re-established without immeidate support with a provisional resotration following an immdiate implant placement. PURPOSE: Successful esthetic outcomes were reported utilizing immediate provisionalization following immediate implant placements. The aim of this study was to evaluate the soft tissue esthetics around immediately placed single tooth implant restorations with or without immediate provisional restorations. METHODS: A total of ten patients, who had a hopeless maxillary anterior tooth, were enrolled in this study. Screw retained provisional restorations were delivered to the randomly chosen 5 patients (immediate provisionalization group) on the day of immediate implant placement and maintained for about 5 months. For the remaining five patients (non-immediate provisionalization group), healing abutments were delivered on the day of surgery, replaced with screw retained provisional restorations approximately 3 months afterwards, and the provisional restorations were maintained for about 3 months. Digital photographs were taken at the delivery of final restorations in order to assess following variables; mesial papilla, distal papilla, soft tissue level, soft tissue contour and facial soft tissue prominence. The variables were compared to those of the contralateral natural tooth and scored by prosthodontists, periodontists, orthodontists and dental students. RESULTS: The immediate provisionalization group marked significantly higher scores on the following variables; soft tissue level and facial soft tissue prominence. In evaluating each variable, there were no notable differences in opinion between four dentist groups. CONCLUSION: Immediate provisionalization can be a treatment option to achieve superior soft tissue esthetics around immediately placed single implant restorations rather than non-immediate provisionalization approaches.
Various biological approaches to the promotion of periodontal regeneration have been used. These can be divided into the use of growth and differentiation factors, application of extracellular matrix proteins and attachment factors and use of mediators of bone metabolism. The purpose of this study was to evaluate the effect of enamel matrix protein and platelet-rich plasma on the treatment of intrabony defect, with bovine-derived bone powder in humans by digital subtraction radiography. 12 teeth(experimental I group) were treated with enamel matrix protein combined with bovine-derived bone powder and 12 teeth(experimental II group) were treated with platelet-rich plasma combined with bovine-derived bone powder. The change of bone density was assessed by digital subtraction radiography in this study. The change of mineral content was assessed in the method that two radiography were put into computer program to be overlapped and the previous image was subtracted by the later one. Both groups were statistically analyzed by Wilcoxon signed Ranks Test and Mann-whitney Test using SPSS program for windows(5% significance level). The results were as follows: 1. The radiolucency in 3 months after surgery was significantly increased than 1 month after surgery in both groups(experimental I and II groups)(p<0.05). 2. The radiopacity in 6 months after surgery was significantly increased than 3 months after surgery in both groups(experimental I and II groups) (p<0.05). 3. In experimental I group, there was no significant difference between 1 month and 6 months after surgery. 4. In experimental II group. the radiopacity in 6 months after surgery was significantly increased than 1 month after surgery(p<0.05). 5. There was no significant difference between experimental I and II group at 1 month and 3 months after surgery, but the radiopacity in experimental II group was significantly increased at 6 months after surgery(p<0.05). In conclusion, platelet-rich plasma can enhance bone density than enamel matrix protein until 6 months after surgery.
Sungwoo Ju;Seoung-Jin Hong;Janghyun Paek;Kwantae Noh;Ahran Pae;Kung-Rock Kwon;Hyeong-Seob Kim
The Journal of Korean Academy of Prosthodontics
/
v.61
no.4
/
pp.316-327
/
2023
In the case of fully edentulous patients with severe alveolar bone resorption, the consideration of 'All-on-X' implant-supported fixed prosthesis after placing four or more implants in the anterior maxilla is possible. Recent advancements in digital dentistry have enabled systematic and predictable treatment in all phases, including diagnosis, surgery, and prosthesis fabrication. By incorporating digital dentistry techniques such as digital complete denture, implant surgical guides, facial scanning into the conventional restoration process, it is possible to reduce the complexity of the prosthesis fabrication and effectively achieve the transition from provisional prosthesis to definitive prosthesis in terms of both aesthetics and function.
When fabricating definitive implant-supported fixed prostheses in upper and lower completely edentulous patients, it is crucial to get information about the vertical dimension, jaw relationship, implants, abutments and gingival contour. In this case, temporary prostheses were used to take the information. The temporary prosthesis was scanned outside of the mouth so that it increased the efficiency of scanning it. During the scan of the prosthesis, a scan zig which connected both posterior parts of the prosthesis was used to minimize the scan errors. We report this case because we obtained satisfactory functional and esthetic results by using the digital technology.
Kim, Min-Beom;Kwon, Ho-Beom;Lim, Young-Jun;Kim, Myung-Joo
The Journal of Korean Academy of Prosthodontics
/
v.60
no.4
/
pp.431-441
/
2022
The digital facebow device records the trajectory of the mandibular movement where it is then reflected on the computer-aided design software, leading to an improvement on treatment outcomes of prosthetic restorations. In this clinical case, using a digital technology, an implant placement and prosthetic restoration were done in a patient who has lost maxillary and mandibular molars. Following an intraoral scan, a surgical stent for implant surgery was fabricated based on digital diagnostic wax-up, and implants were installed. After six months of sufficient osseointegration, customized abutments and the first temporary prostheses were delivered. Then two months later, at an abutment level, an intraoral scan and digital facebow transfer device were used to mount the intraoral scan data on a virtual articulator, and record the mandibular movements. Once the second temporary prostheses were fabricated and delivered on a basis of the mandibular movement, the definitive zirconia prostheses were designed and delivered based on a stabilized occlusion that was duplicated via double scan technique.
Temporal bone CT scan side skull fracture. In addition to the confirmation of the ossicles, such as fractures and dislocations, temporomandibular facial fractures, deformities surgery helps to establish a science plan. Cochlear implant surgery has been performed in the state before and after identifying purposes. Test methods are being implemented by the Conventional direct axial and Direct coronal scan, the basic method of Temporal bone CT. Helical scan is a fast Volumetric data obtained compared with the Conventional scan, the patient reduced the dose, and there are some advantages, such as reduced Beam hardening streak artifacts caused by dental fillings. This study is a comparative analysis by dose reduction for patients with a dose according to the conventional scan method and then effective from 2015 by helical scan method performed in 2014 through the retrospective survey, which was then optimized for the purpose of inspection.
Park, Kun-Hyun;Park, Su-Hyun;Lee, Sung-Hwy;Pyo, Sung-Woon
Maxillofacial Plastic and Reconstructive Surgery
/
v.32
no.5
/
pp.389-395
/
2010
Purpose: Although it is generally accepted that patients with controlled diabetes have similar rates of success for dental implants as healthy individuals, the use of dental implants in diabetic patients is controversial. In addition, the impact of diabetes on the healing of bone associated with immediately place dental implants is not completely understood. The purpose of this study was to measure bone response to implants radiologically in uncontrolled and insulin-controlled diabetic rats. Materials and Methods: Twenty rats were divided into control, insulin-treated and diabetic groups. The rats received streptozotocin (60 mg/kg) to induce diabetes; animals in the insulin-treated group also received three units of subcutaneous slow-release insulin. Two titanium implants ($1.2{\times}3$ mm) were placed in the extraction socket of the maxillary first molars of the animals and were harvested at 3 days, 1, 2 and 4 weeks. The bone density was measured by digital radiography using gray-level analysis (histogram) in the regions of interest (ROI) at four points: two mesial and two distal to both sides of the implant. Results: The results showed that the osseointegration of the implants was impaired in the diabetic rats compared to the control and the insulin-treated rats. The radiographic evidence demonstrated marked destruction of bone around the implants in the diabetic group. Both the control and the insulin-treated groups had a significantly higher bone density on radiograph than the diabetic group from the 1 week of the experiment (P<0.05 for each comparison). Conclusion: The present study revealed that the immediate placement of titanium implants in the maxilla of diabetic rat lead to delay in the maturation of bone adjacent to implants. It is expected that the reduced predictability of success of immediate implantation in patient with the uncontrolled diabetes.
Kim Hyun-Woo;Huh Kyung-Hoe;Park Kwan-Soo;Kim Jeong-Hwa;Yi Won-Jin;Heo Min-Suk;Lee Sam-Sun;Choi Soon-Chul
Imaging Science in Dentistry
/
v.36
no.1
/
pp.25-32
/
2006
Purpose : To investigate the validity of digital image processing on panoramic radiographs in estimating bone quality before endosseous dental implant installation by correlating bone quality in radiographic images with clinical bone quality classification. Materials and Methods : An experienced surgeon assessed and classified bone quality for implant sites with tactile sensation at the time of implant placement. Including fractal dimension eighteen morphologic features of trabecular pattern were examined In each anatomical sites on panoramic radiographs. Finally bone quality of 67 implant sites were evaluated in 42 patients. Results : Pearson correlation analysis showed that three morphologic parameters had weak linear negative correlation with clinical bone quality classification showing correlation coefficients of -0.276, -0.280, and - 0.289, respectively (p<0.05). And other three morphologic parameters had obvious linear negative correlation with clinical bone quality classification showing correlation coefficients of -0.346, -0.488, and -0.343 respectively (p<0.05). Fractal dimension also had a linear correlation with clinical bone quality classification with correlation coefficients -0.506 significantly (p<0.05). Conclusion : This study suggests that fractal and morphometric analysis using digital panoramic radiographs can be used to evaluate bone quality for implant recipient sites.
Purpose: The purpose of this study is to compare the accuracy of the CT guided implant template that was produced by using an intraoral scanner according to the edentulous distance. Materials and methods: Five maxillary casts were fabricated using radiopaque acrylic resin with the second premolars, first molars, and second molars missing. Then a virtual cast was acquired by scanning each resin cast. Implant treatment was planned on the missing sites by superimposing the presurgical CT DICOM file and the virtual cast. Then the implants were placed using a surgical template followed by postsurgical CT scan. The distance and angle of the platform and apex between the presurgical implant and postsurgical implant were measured using the X, Y, and Z axis of the superimposed presurgical CT and postsurgical CT via software followed by statistical analysis using Kruskall-Wallis test and Mann-Whitney test. Results: The implant placement angle error increased towards the second molars but there was no statistically significant difference. The implant placement distance error at the platform and apex also increased towards the second molars and there was a statistically significant error at the second molars. Conclusion: Although the placement angle had no statistically significant difference between the presurgical implant and postsurgical implant, the placement distance at the platform and apex showed a larger error and a statistically significant difference at the second molar implant.
Purpose: The aim of this study was to evaluate the heat generation in bone in vitro during the guided flapless drilling procedure and the effect of drilling methods on the heat generation. Materials and methods: A model that has missing the first and second mandibular molars bilaterally was used. In group A, classical flap implant surgery was performed. In group B, flapless implant surgery using surgical guide was performed. In group C, flapless implant surgery using surgical guide without up-and-down pumping motion was performed. Temperature was measured with k-type thermocouple and a real-time digital thermometer. The thermocouples were placed at 0.5 mm away from the osteotomy area at the depths of 3 mm and 6 mm. The measured values were evaluated with independent t-test. Results: The mean temperature generated was $27.2^{\circ}C$ ($SD{\pm}2.1^{\circ}C$) and $27.5^{\circ}C$ ($SD{\pm}2.3^{\circ}C$) for groups A and B, respectively. These differences were not statistically significant. In group C, the mean temperature was $37.0^{\circ}C$ ($SD{\pm}3.4^{\circ}C$). There were statistically significant differences between groups B and C with respect to the mean temperature. Conclusion: These findings suggest that guided flapless drilling with up-and-down pumping motion may not significantly increase the bone temperature.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.