• Title/Summary/Keyword: Digital imaging system

검색결과 509건 처리시간 0.026초

피부병변의 정량적 평가를 위한 디지털 컬러 영상 시스템 (Digital Color Imaging Systems for Quantitative Evaluation of Skin Lesions)

  • 한병관;정병조
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권2호
    • /
    • pp.195-198
    • /
    • 2007
  • In this paper, we introduce a digital cross-polarization and fluorescent color imaging system for quantitative evaluation of skin lesions. We describe the characterization of the imaging systems and the quantitative image analysis methods to show the feasibility for quantitative evaluation of skin lesions. The polarization color image was used to compute erythema and melanin index image which are useful for quantitative evaluation of pigmentation and vascular skin lesions, respectively. The fluorescent color image was used to quantitatively evaluate "sebum" and "vitiligo". In quantitative evaluation of various skin lesions, we confirmed the clinical efficacy of the imaging systems for dermatological applications. Finally, we sure that the imaging systems can be utilized as important assistant tools for the evaluation of skin lesions by providing reproducible quantitative result for widely distributed skin lesions.

비정질 셀레늄을 이용한 평판 Digital X선 검출기 개발 (Development of flat panel digital x-ray detectorusing a-Se)

  • 박지군;최장용;강상식;차병열;장기원;최준영;남상희
    • 대한디지털의료영상학회논문지
    • /
    • 제6권1호
    • /
    • pp.24-30
    • /
    • 2003
  • 평판 digital x-선 검출기는 차세대 x-ray system으로 최근 연구와 개발이 활발하게 진행되고 있는 system이다. 본 연구는 환자의 피폭 및 작업 종사자의 피폭을 최소화 할 수 있고 의료장비의 디지털화에 발맞추어 PACS 등에 사용 가능한 a-Se을 이용한 직접방식의 digital x-선 검출기 구현에 관한 것이다. Prototype digital x-선 검출기는 TFT층과 a-Se층으로 이루어져 있다. Digital x-선 검출기센서 증착과 정의 최적화 수행 결과를 참고문헌1)-4)과 비교했을 때 매우 유사함을 확인하였다. 제작된 검출기의 pixel pitch는 $139{\mu}m$였고, fill factor는 86%, 전체 검출기의 검출면적은 14"${\times}$8.5"였다. Digital 영상의 해상력을 고려하기 위해 손과 test 패턴영상을 얻었고, 58%, 3.0lp/mm의 높은 MTF를 얻을 수가 있었다. 이러한 결과로 a-Se 기반의 Digital X선 검출기가 구현되었으며 본 연구결과를 토대로 향후 digital X선 검출기 개발기술의 발전과 성능향상을 가져올 것으로 기대된다.

  • PDF

일반촬영을 위한 셀레늄 기반의 엑스선 검출기 시스템 (System of a Selenium Based X-ray Detector for Radiography)

  • 이동길;박지군;최장용;안상호;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집 Vol.3 No.2
    • /
    • pp.817-820
    • /
    • 2002
  • Amorphous selenium based flat panel detectors convert incident x-ray to electric signal directly. Flat panel detectors gain more interest real time medical x-ray imaging. TFT array and electric readout circuits are used in this paper offered by LG.Philips.LCD. Detector is based on a $1536{\times}1280$ array of a-Si TFT pixels. X-ray conversion layer(a-Se) is deposited upper TFT array with a $400{\mu}m$ by thermal deposition technology. Thickness uniformity of this layer is made of thickness control system technology$({\leq}5%)$. Each $139{\mu}m{\times}139{\mu}m$ pixel is made of thin film transistor technology, a storage capacitor and collecting electrode having geometrical fill factor of 86%. This system show dynamic performance. Imaging performance is suited for digital radiography imaging substitute by conventional radiography film system.

  • PDF

치아 우식증 진단시 필름 방사선사진상과 디지털 방사선영상의 비교:CCD, CMOS, PSP와 film (A comparison of film and 3 digital imaging systems for natural dental caries detection: CCD, CMOS, PSP and film)

  • 한원정
    • Imaging Science in Dentistry
    • /
    • 제34권1호
    • /
    • pp.1-5
    • /
    • 2004
  • Purpose: To evaluate the diagnostic accuracy of occlusal and proximal caries detection using CCD, CMOS, PSP and film system. Materials and Methods : 32 occlusal and 30 proximal tooth surfaces were radiographed under standardized conditions using 3 digital systems; CCD (CDX-2000HQ, Biomedysis Co., Seoul, Korea), CMOS (Schick, Schick Inc., Long Island, USA), PSP (Digora/sup (R)/FMX, Orion Co./Soredex, Helsinki, Finland) and I film system (Kodak Insight, Eastman Kodak, Rochester, USA). 5 observers examined the radiographs for occlusal and proximal caries using a 5-point confidence scale. The presence of caries was validated histologically and radiographically. Diagnostic accuracy was evaluated using ROC curve areas (Az). Results: Analysis using ROC curves revealed the area under each curve which indicated a diagnostic accuracy. For occlusal caries, Kodak Insight film had an Az of 0.765, CCD one of 0.730, CMOS one of 0.742 and PSP one of 0.735. For proximal caries, Kodak Insight film had an Az of 0.833, CCD one of 0.832, CMOS one of 0.828 and PSP one of 0.868. No statistically significant difference was noted between any of the imaging modalities. Conclusion: CCD, CMOS, PSP and film performed equally well in the detection of occlusal and proximal dental caries. CCD, CMOS and PSP-based digital images provided a level of diagnostic performance comparable to Kodak Insight film.

  • PDF

Wireless PACS

  • 김현철
    • 대한디지털의료영상학회논문지
    • /
    • 제5권1호
    • /
    • pp.130-136
    • /
    • 2002
  • One of current trends of medical technology is analog to digital. Moreover, The Government put a premium on PACS(Picture Archiving and Communication System) for Medical Insurance in November, 1999. Therefore many hospitals are installing(or planning to install) PACS facilities on their buildings. However most of hospitals didn't consider PACS facilities in the beginning of construction. In particular, the Networking is one of the most difficult things for PACS installation. There is no space for network equipments, and no path for network lines, etc. To solve these problems, wireless network is proposed. The wireless network is divided to three parts mainly. One is the wireless communication for Local Area Network, another is the data transmission through a satellite for Tele-Radiology, and the last one is the technology using Bluetooth for each sub-system of PACS. But there are other problems in wireless systems, i.e., network bandwidth, system stability, interference with other devices. The purpose of this paper is to suggest the future and new trend of PACS including all the problems.

  • PDF

웨이브렛 변환과 자동적인 임계치 설정에 의한 미세 석회화 검출 (Microcalcification Extraction by Wavelet Transform and Automatic Thresholding)

  • 원철호;서용수;조진호
    • 한국멀티미디어학회논문지
    • /
    • 제8권4호
    • /
    • pp.482-491
    • /
    • 2005
  • 본 논문에서는 디지털 X선 유방 촬영 시스템에서 획득된 영상으로부터 웨이브릿 변환과 자동적인 임계치 설정기법을 이용하여 미세 석회화 영역을 추출하였다. 디지털 X선 영상 장비는 임상 진단 분야에서는 필수적인 진단 장비이며, 흉부 촬영, 골절상 및 치아 교정 등의 다양한 분야에 사용되고 있다. 특히 디지털 X선 유방 촬영술은 유방암 진단의 가장 좋은 방법으로 알려져 있으며 최근 국내에서 디지털 X선 기기를 개발하기 위한 많은 연구들이 진행되고 있다. 본 논문에서는 디지털 X선 유방 촬영 영상으로부터 초기 단계의 유방암 진단을 위해 필수적인 미세 석회화를 검출하는 알고리즘을 제안하여 이를 효과적으로 검출하였으며 진단 방사선학적 진단에 도움을 줄 수 있음을 보였다.

  • PDF

비공학도를 위한 X-ray 영상촬영 시스템 해상력 평가 방법 (An Evaluation Method of X-ray Imaging System Resolution for Non-Engineers)

  • 우정은;이용금;배석환;김용권
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제35권4호
    • /
    • pp.309-314
    • /
    • 2012
  • Digital Radiography(DR) 시스템은 임상현장에서 아날로그 시스템을 대체하고 널리 이용되고 있다. DR을 이용하여 얻어진 X선 영상의 해상력을 결정짓는 요소에는 이용되는 검출기의 고유 해상력, 피사체의 대조도 및 특성, X선 선질, X선원의 산란, DR 검출기의 성능, X선 변환효율 및 초점의 크기, 피사체의 움직임 등이 있다. DR 검출기를 구성하는 요소에는 X선 포획 요소, 커플링 요소, 정보수집 요소가 있는데 이들은 시스템의 성능에 영향을 미치며, 그 성능은 해상력으로 평가된다. 의료영상 시스템의 해상력은 촬영대상물의 조직 간의 해부학적 영상을 구분하는 능력을 나타낸다. 해상력 평가를 위해 Modulation Transfer Function(MTF)이 보편적으로 이용되고, MTF는 입력 공간주파수 성분에 대한 출력 공간주파수 성분의 비를 나타내는데, 수학적으로 MTF는 Point Spread Function(PSF) 입력에 대한 시스템의 주파수 응답이며 Edge Phantom을 이용한 결과 영상에서 추출된 Line Spread Function(LSF)을 Fourier Transform하면 얻을 수 있다. 일반적으로 임상현장에서 의료영상시스템의 이용 및 관리의 책임은 방사선사가 맡고 있지만, MTF를 측정하기 위해서는 공학적, 수학적 기초 및 C, Fortran, Matlab등의 프로그램 작성 능력이 필요하기 때문에 비 공학도는 정확한 측정이 불가능하다. 의료영상 시스템의 성능 관리 및 최상의 상태를 유지하기 위해 시스템의 성능평가가 이뤄져야 하는데, 이를 위해 본 연구에서는 비공학도가 해상력 성능평가를 할수 있도록 ImageJ 및 Excel을 이용하여 해상력 평가를 할 수 있도록 방법을 제시하고, 제안된 방법을 이용해 계산된 결과와 프로그래밍을 이용해 계산된 결과의 비교를 통해 본 논문에서 제시하는 방법의 유용성을 확인하였다.

초음파 영상 시스템에서 디지탈 Beam Forming을 위한 개선된 2차 샘플링 방법 (An Improved Second-odrer Sampling Method for Digital Beam Forming in Ultrasound Imaging Systems)

  • 조완희;안영복
    • 전자공학회논문지B
    • /
    • 제32B권1호
    • /
    • pp.110-119
    • /
    • 1995
  • The lateral resolution in an ultrasound imaging system is one of the most important factors for quality of the image and is determined by the beam focusing. For the better lateral resolution SDF(Sampled Delay Focusing) capable of digital focusing was proposed. The second-order sampling, one of band-width sampling methods, is suggested as being the best suitable for SDF because it allows total digital processing and is simple and economical. By proving that it introduces too much error, this article shows the second-order sampling is not appropriate for sampling of the wide-band signal generally used in ultrasound imaging systems. Also, this article suggests new sampling methods that maintain the advantages and reduce the unavoidable errors of the second-order sampling method. From computer simulation it is expected that the proposed methods reduce the errors of the second-order sampling method and can be used in real applications.

  • PDF

3D imaging and 3D display based on digital holography

  • Matoba, Osamu
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2009년도 창립 20주년기념 특별학술발표회
    • /
    • pp.133-134
    • /
    • 2009
  • We have presented our approach to build a 3D display system based on digital holography. For wide viewing angle, we have presented several techniques such as measurement, time-sharing display, and coherent amplification. These techniques can advance the wavefront 3D display system to next stage.

  • PDF

다양한 필터링 기법을 이용한 디지털 X-선 영상복원 시뮬레이션 및 정량적 화질평가 (Image Restoration Simulation of Digital X-ray Images Based upon Filtering Techniques and the Quality Evaluation of the Restored Images)

  • 이소영;최성일;오지은;조희문;이성주;박연옥;조효성
    • 한국방사선학회논문지
    • /
    • 제2권4호
    • /
    • pp.33-40
    • /
    • 2008
  • 의료영상 시스템을 통해 볼 수 있는 모든 X-선 영상은 피사체 본래의 특성만이 표현된 영상이 아닌 그 영상시스템 고유의 특성이 반영된 영상이라 할 수 있다. 영상화질에서 시스템에 의한 열화는 시스템응답함수인 변조전달 함수(modulation transfer function; MTF)로 설명되며 잡음력 스펙트럼(noise power spectrum; NPS)으로 설명할 수 있다. 이 때, 열화된 영상은 영상시스템의 MTF와 NPS를 정확하게 측정함으로써 그 시스템의 특성에 따라 설계된 필터에 의해 원영상에 가깝게 복원(restoration)될 수 있다. 본 논문에서는, 영상복원 시뮬레이션을 통해 기존의 직접 역필터링(direct-inverse filtering), 제한된 역필터링(limited-inverse filtering), 위너 필터링(Wiener filtering) 기법을 바탕으로 열화된 영상을 원 영상에 가깝도록 복원하고 복원영상의 화질을 정량적으로 평가하였다.

  • PDF