• 제목/요약/키워드: Digital image acquisition

검색결과 248건 처리시간 0.026초

Background Removing for Digital image self-adaptive acquisition in medical X-ray imaging

  • Li, Xun;Kim, Young-Ju;Song, Young-Jun
    • International Journal of Contents
    • /
    • 제4권1호
    • /
    • pp.12-15
    • /
    • 2008
  • In this paper, we propose a new method of background removing for digital self-adaptive acquisition in medical X-ray imaging. We analysis the construction of video digital acquisition system and main factors of acquired image quality, propose a more efficiency method to against background non-uniformly. With proposed method, non-uniform illumination back ground was well removed without image quality degradation.

디지털 x-ray 영상시스템을 위한 무선 트리거 발생기 (Wireless Triggering Pulse Generation for Digital X-ray Imaging System)

  • 고대식;이재철;이주신
    • 한국항행학회논문지
    • /
    • 제11권2호
    • /
    • pp.163-169
    • /
    • 2007
  • 본 논문에서는 x-ray 영상시스템의 영상을 획득하기 위하여 x-ray 발생기와 영상획득시스템 사이의 동기를 맞추어 주는 트리거 발생기를 연구분석 하였다. 무선 트리거 발생기는 디지털영상 획득시스템으로부터 영상획득의 시작을 지시할 수 있는 ACQ_START 신호와 영상획득의 끝을 알리는 ACC_END 신호를 발생시킬 수 있도록 설계하였다. 디지털 영상의 획득은 ACQ_START 신호와 ACQ_END 신호 사이의 시간동안에만 정확하게 이루어지며 무선 원격 x-ray 신호의 검출을 통하여 유선통신 프로토콜 없이 정확한 x-ray 영상의 획득이 가능하고 20 mAs 의 x-ray 레벨에서 3.5 line pair /mm 분해능을 나타냄을 확인하였다.

  • PDF

3차원 수치영상을 이용한 암반사면의 지표정보 획득 (The Surface Information Acquisition of Rock Slope using 3D Digital Image)

  • 엄대용;강준묵
    • 한국측량학회:학술대회논문집
    • /
    • 한국측량학회 2004년도 춘계학술발표회논문집
    • /
    • pp.203-208
    • /
    • 2004
  • Recently, digital image is increasing greatly practical use degree in several industry fields including construction. And interest about 3D digital image that can express practical object realistically is augmented greatly. In this study, developed 3D digital image generation system based on digital photogrammetry and created 3D digital image for object. And, wished to verify of 3D digital image through comparative analysis with processing result by digital photogrammetry system been using much the latest for acquisition of 3D information. Also, wished to apply to surface information acquisition about rock slope and execute investigation about discontinuity of joint etc. As the result, could created 3D digital image for object using the 3D digital image generation system developing in this study, and acquire surface information about rock slope efficiently.

  • PDF

망막 두께 측정을 위한 32채널 영상획득장치 개발 (Development of 32-Channel Image Acquisition System for Thickness Measurement of Retina)

  • 양근호;유병국
    • 융합신호처리학회 학술대회논문집
    • /
    • 한국신호처리시스템학회 2003년도 하계학술대회 논문집
    • /
    • pp.110-113
    • /
    • 2003
  • In this paper, the multi-channel high speed data acquisition system is implemented. This high speed signal processing system for 3-D image display is applicable to the manipulation of a medical image processing, multimedia data and various fields of digital image processing. In order to convert the analog signal into digital one, A/D conversion circuit is designed. PCI interface method is designed and implemented, which is capable of transmission a large amount of data to computer. In order to, especially, channel extendibility of images acquisition, bus communication method is selected. By using this bus method, we can interface each module effectively. In this paper, 32-channel A/D conversion and PCI interface system for 3-dimensional and real-time display of the retina image is developed. The 32-channel image acquisition system and high speed data transmission system developed in this paper is applicable to not only medical image processing as 3-D representation of retina image but also various fields of industrial image processing in which the multi-point realtime image acquisition system is needed.

  • PDF

The Study of Acquisition Signal Distortion due to Edge Effect in Direct Digital Radiography System

  • Cho, Jin-Wook;Choi, Jang-Yong;Mun, Chi-Woona;Lee, Hyung-Won;Nam, Sang-Hee
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.179.1-179
    • /
    • 2001
  • Successive image contrast enhancement was used to direct digital radiography system. This system was accurately required acquisition signal in each pixel. But, applied high electric field in a-Se thin film for x-ray conversion layer was caused to acquisition signal distortion, then bring low image contrast. The purpose of this study was to reduce the signal distortion, carried out different electrode size.

  • PDF

무선조정 헬리콥터 사진측량시스템을 이용한 절취사면 정보 추출 (Extraction of Information on Road Cutting Slope using RC Helicopter Photographic Surveying System)

  • 이종출;이영도;김진수;조용재
    • 한국측량학회:학술대회논문집
    • /
    • 한국측량학회 2004년도 추계학술발표회 논문집
    • /
    • pp.217-222
    • /
    • 2004
  • In this study, cutting slope's digital image has acquired by using video camera attached at RC helicopter. Resulted RMSE from image processing was approximately x-direction 0.27m, y-direction 0.23m and z-direction 0.35m. Application of these methods makes it convenient that acquisition of digital image about before and after the construction work of road cutting slope. Also systematical cutting slope's information acquisition will be possible by cutting slope's quantitative and qualitative analysis.

  • PDF

디지털 화상처리에 의한 해양유출기름확산 계측기법개발에 관한 연구 (A study on a development of a measurement technique for diffusion of oil spill in the ocean)

  • 이중우;김기철;강신영;도덕희
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 1998년도 추계학술대회논문집:21세기에 대비한 지능형 통합항만관리
    • /
    • pp.211-221
    • /
    • 1998
  • A digital image processing technique which is able to get the velocity vector distribution of a surface of the spilled oil in the ocean without contacting the flow itself. This technique is based upon the PIV(Particle Imaging Velocimetry) technique and its system mainly consists of a high sensitive camera, a CCD camera, an image grabber, and a host computer in which an image processing algorithm is adopted for velocity vector acquisition. For the acquisition of the advective velocity vector of floating matters on the ocean, a new multi-frame tracking algorithm is proposed, and for the acquisition of the diffusion velocity vector distribution of the spilt oil onto the water surface, a high sensitive gray-level cross-correlation algorithm is proposed.

  • PDF

디지털 화상처리에 의한 해양유출기름확산 계측기법개발에 관한 연구 (A Study on a Development of a Measurement Technique for Diffusion of Oil Spill in the Ocean)

  • 이중우;강신영;도덕희;김기철
    • 한국항만학회지
    • /
    • 제12권2호
    • /
    • pp.291-302
    • /
    • 1998
  • A digital image processing technique which is able to be used for getting the velocity vector distribution of a surface of the spilt oil in the ocean without contacting the flow itself. This technique is based upon the PIV(Particle Imaging Velocimetry) technique and its system mainly consists of a high sensitive camera, a CCD camera, an image grabber, and a host computer in which an image processing algorithm is adopted for velocity vector acquisition. For the acquisition of the advective velocity vector of floating matters on the ocean, a new multi-frame tracking algorithm is proposed, and for the acquisition of the diffusion velocity vector distribution of the spilt oil onto the water surface, a high sensitive gray-level cross-correlation algorithm is proposed.

  • PDF

Software Analysis and Design of the Image Acquisition Subsystem Using the Unified Modeling Language

  • Yom, Jae-Hong
    • Korean Journal of Geomatics
    • /
    • 제1권1호
    • /
    • pp.85-93
    • /
    • 2001
  • Geospatial database, which is the basis for Geo-Spatial Information Systems, is produced by conventional mapping methods. Recently, with increased demand for digital forms of the geospatial database, studies are carried out to automate its production. The automated mapping system is composed of the image acquisition subsystem, positioning subsystem, point referencing subsystem and the visualization subsystem. The image acquisition subsystem is the most important part of the overall production line because it is the starting point and will affect all subsequent processes. This paper presents a software analysis and design of the image acquisition subsystem. The design was carried out using the Unified Modeling Language which is a modeling method used extensively in the software engineering field.

  • PDF

The effects of image acquisition control of digital X-ray system on radiodensity quantification

  • Seong, Wook-Jin;Kim, Hyeon-Cheol;Jeong, Soocheol;Heo, Youngcheul;Song, Woo-Bin;Ahmad, Mansur
    • Restorative Dentistry and Endodontics
    • /
    • 제38권3호
    • /
    • pp.146-153
    • /
    • 2013
  • Objectives: Aluminum step wedge (ASW) equivalent radiodensity (eRD) has been used to quantify restorative material's radiodensity. The aim of this study was to evaluate the effects of image acquisition control (IAC) of a digital X-ray system on the radiodensity quantification under different exposure time settings. Materials and Methods: Three 1-mm thick restorative material samples with various opacities were prepared. Samples were radiographed alongside an ASW using one of three digital radiographic modes (linear mapping (L), nonlinear mapping (N), and nonlinear mapping and automatic exposure control activated (E)) under 3 exposure time settings (underexposure, normal-exposure, and overexposure). The ASW eRD of restorative materials, attenuation coefficients and contrasts of ASW, and the correlation coefficient of linear relationship between logarithms of gray-scale value and thicknesses of ASW were compared under 9 conditions. Results: The ASW eRD measurements of restorative materials by three digital radiographic modes were statistically different (p = 0.049) but clinically similar. The relationship between logarithms of background corrected grey scale value and thickness of ASW was highly linear but attenuation coefficients and contrasts varied significantly among 3 radiographic modes. Varying exposure times did not affect ASW eRD significantly. Conclusions: Even though different digital radiographic modes induced large variation on attenuation of coefficient and contrast of ASW, E mode improved diagnostic quality of the image significantly under the underexposure condition by improving contrasts, while maintaining ASW eRDs of restorative materials similar. Under the condition of this study, underexposure time may be acceptable clinically with digital X-ray system using automatic gain control that reduces radiation exposure for patient.