• 제목/요약/키워드: Digital dental model

검색결과 148건 처리시간 0.025초

치과용 3D 프린팅 기술로 제작된 가공물의 정밀성 분석 (Precision Analysis of Workpieces made with Dental 3D Printing Technology)

  • 최성민
    • 대한치과기공학회지
    • /
    • 제40권4호
    • /
    • pp.231-237
    • /
    • 2018
  • Purpose: The development of the dental technology industry has digitized the dental process. Definition of Digitalization of Dental Implantation Digitalization is the process of model making and prosthodontic processing using 3D CAD and CAM. Currently, it is becoming popular due to the spread of various devices. However, precision evaluation at this stage is an important factor in precision-based dental procedures. Therefore, in this study, we want to analyze the precision of the processed body made with digital dental machine. Methods: The accuracy of digital dental pore devices was evaluated. Specimens were fabricated with 5 types of 3D printers. The external shape was measured with the prepared specimen. The surface roughness was measured. Results: As a result, precision was excellent in order of EP2 specimen, EP1 specimen, and EA2 specimen. The precision of EP3 specimen and EA1 specimen is not excellent. And the precision of the specimen processed with polymer 3D printer is excellent. The accuracy of LCPS type polymer 3D printers is considered to be excellent. Conclusion : 1. Observation of the shape The 3D printer for LCPS system and the 3D printer for SLM $40{\mu}m$ system were found to be precisely processed. 2. Surface roughness results The LCPS system polymer 3D printer has been shown to have a precise surface.

임상가를 위한 특집 2 - CAD/CAM 기술을 활용한 최신 교정치료 - 교정진단에서 간접부착술식까지 (Current Orthodontic Treatment using CAD/CAM technology: from orthodontic diagnosis to indirect bonding procedure)

  • 차정열
    • 대한치과의사협회지
    • /
    • 제52권1호
    • /
    • pp.17-26
    • /
    • 2014
  • Computerized 3D virtual dental models are currently available, and their use has started to improve treatment outcomes. The accuracy of digital models has been demonstrated by many studies and various intra-oral scanners are innovated for short scanning time and high precision. Recently, a digital model was combined with a high technology computer-driven system, which was developed for the application of a digital set-up and indirect bonding of lingual attachments. In this section, virtual treatment planning using a virtual set-up program is be introduced, and the clinical applications and accuracy of computer-generated indirect bonding are discussed.

A method for mandibular dental arch superimposition using 3D cone beam CT and orthodontic 3D digital model

  • Park, Tae-Joon;Lee, Sang-Hyun;Lee, Ki-Soo
    • 대한치과교정학회지
    • /
    • 제42권4호
    • /
    • pp.169-181
    • /
    • 2012
  • Objective: The purpose of this study was to develop superimposition method on the lower arch using 3-dimensional (3D) cone beam computed tomography (CBCT) images and orthodontic 3D digital modeling. Methods: Integrated 3D CBCT images were acquired by substituting the dental portion of 3D CBCT images with precise dental images of an orthodontic 3D digital model. Images were acquired before and after treatment. For the superimposition, 2 superimposition methods were designed. Surface superimposition was based on the basal bone structure of the mandible by surface-to-surface matching (best-fit method). Plane superimposition was based on anatomical structures (mental and lingual foramen). For the evaluation, 10 landmarks including teeth and anatomic structures were assigned, and 30 times of superimpositions and measurements were performed to determine the more reproducible and reliable method. Results: All landmarks demonstrated that the surface superimposition method produced relatively more consistent coordinate values. The mean distances of measured landmarks values from the means were statistically significantly lower with the surface superimpositions method. Conclusions: Between the 2 superimposition methods designed for the evaluation of 3D changes in the lower arch, surface superimposition was the simpler, more reproducible, reliable method.

일부 치위생(학)과 학생의 학과 만족도에 관한 융합연구 : 접근 동기, 회피 동기, 디지털 사용인식 중심으로 (A Convergence Study on Partial Dental Hygiene (Department) and Student Satisfaction: Focusing on Approach Motivation, Avoidance Motivation, and Digital Use Recognition)

  • 손은교
    • 한국융합학회논문지
    • /
    • 제13권5호
    • /
    • pp.53-60
    • /
    • 2022
  • 본 연구는 강원도 일개 대학 치위생과 학생을 239명을 대상으로 치위생과 상생 방안 마련을 위해, 접근 동기와 회피 동기, 디지털 사용 인식을 통한 구조모형의 인과관계를 파악하는 것이다. 통계 방법은 SPSS Statistics 24.0 프로그램과 AMOS 21.0을 이용하였다. 구조방정식 모델 분석 결과 접근 동기는 디지털 사용 인식과 수업 만족도에 유의하게 나타났다. 또한, 디지털 사용인식은 수업 만족도에 유의하게 나타났고, 수업 만족도는 학과 만족도와 학과 추천에 유의하게 나타났다. 마지막으로 학과 만족도는 학과 추천에 유의하게 나타났다. 즉, 치위생(학)과의 상생 방안은 디지털 수업의 융합 확대이다. 문제 해결을 위해서는 학교에서는 실기 수업을 위한 수업 자재의 확충 시설 구축 및 교수법을 강구할 필요가 있다.

치과 진료실에서 3D 프린트의 활용 (Application of 3D printer in dental clinic)

  • 김현동
    • 대한심미치과학회지
    • /
    • 제27권2호
    • /
    • pp.82-96
    • /
    • 2018
  • 3D 프린팅은 삼차원 이미지 정보를 이용하여 레이어로 분할한 후 선택한 소재를 적층하여 가공하는 방법을 말한다. 소재를 적층하는 방법에 따라 다양한 종류의 3D 프린팅이 존재하는데 최근 치과분야에서는 SLA방식과 DLP방식으로 광원을 이용한 경화를 통해 적층 가공하는 3D 프린팅이 널리 보급되어 사용되고 있다. 전악 범위의 3D프린팅 치과용 모델은 전통적인 인상 채득으로 제작된 스톤모델보다는 다소 정확성이 부족한 것으로 보고되었으나, 같은 STL파일을 이용하여 4분악 범위를 3D 프린팅한 모델은 밀링 방법으로 가공한 모델보다 정확하였다. 디자인 소프트웨어의 활용도에 따라 보철치료의 진단, 임시 보철물의 제작, 의치의 제작이 가능하였다. 교정에서는 투명 교정 모델과 브라켓 간접 부착을 위한 트레이 제작이 가능하였다. 임플란트 수술에 있어서 CT를 기반으로 한 정확한 위치에 임플란트를 식립하는 가이드 제작에 활용하고 있다. 출력 방식의 발전으로 인하여 3D 프린터의 출력시간이 계속적으로 단축되고 있으며, 이로 인해 치과 진료실 내에서 3D 프린터가 기존의 전통적인 가공 방법을 대체할 수 있을 것으로 기대한다.

치과용 모형재 색상에 따른 디지털 모형의 체적 안정성 연구 (The study on the dimensional stability of digitized dental stone replicas according to difference color of gypsum materials)

  • 최석순;김기백;이경탁;전진훈;김재홍
    • 대한치과기공학회지
    • /
    • 제34권4호
    • /
    • pp.369-377
    • /
    • 2012
  • Purpose: The aim of study was to compare the dimensional stability of digitized dental stone replica using different color of gypsum materials using a white light scanner with three-dimensional software. Methods: A master model(500B-1, Nissin dental product, Japan) with the prepared lower full arch tooth was used. Several type IV stones(white, yellow, green) were used for 30 stone casts(10 casts each) duplicated a master model of mandible. The master model and the replicas were digitized with the non-contacting white light scanner to create 3-dimensional digital models. The linear distance between the reference points were measured and analyzed on the Delcam Copycad$^{(R)}$(Delcam plc, UK) 3D graphic software. One-way analysis of variance(ANOVA) combined with a Tukey multiple-range test were used to analysis the data(${\alpha}$=0.05). Results: There were considerable differences in mean values between gypsum materials within each color(white, yellow, green), and this difference was statistically significant, p=0.001. Conclusion: Digitization of dental materials on optical scanner was affected by color. Three different color of gypsum materials showed clinically acceptable accuracies of full arch digital model produced by them. Besides, these results will have to be confirmed in further clinical studies.

Wax-up으로 조각한 치관과 CAD로 설계한 치관의 형태 비교 (Shape comparison of Wax-up carved crown and CAD-designed crown)

  • 김갑진
    • 대한치과기공학회지
    • /
    • 제39권2호
    • /
    • pp.93-99
    • /
    • 2017
  • Purpose: With the development of digital dental technology, we are manufacturing prosthetic crown in various ways. However, the wax-up method that makes existing prosthetic crown is also used steadily. Thus, we will compare the shape of the crown designed with wax-up and the crown designed with CAD. Methods: Sculpt the crown with wax-up on the model to 10 dental technicians. The same model was used to design the crown CAD. Measure the size of the sculpted crown. The shapes were compared in three dimensions. Results: As a result, we could observe a difference in size and shape in crown designed with wax - up crown and crown. Conclusion: These results suggest that there are differences according to the method of carving crown and the method of processing.

Blue LED 방식의 스캐너로 제작된 치과용 3차원 디지털 모형의 정확도 평가 (Evaluation of validity of three dimensional dental digital model made from blue LED dental scanner)

  • 김재홍;정재관;김기백
    • 한국산학기술학회논문지
    • /
    • 제15권5호
    • /
    • pp.3007-3013
    • /
    • 2014
  • 본 연구의 목적은 블루 LED 기반의 치과용 스캐너를 이용하여 제작된 3차원 디지털 모형의 정확도를 평가하는 것이다. 본 연구를 위하여 20개의 동일한 석고 모형 제작 후 블루 LED기반의 치과용 스캐너를 이용하여 석고 모형과 동일한 20개의 3차원 디지털 모형을 제작하였다. 정확도를 평가하기 위해 두 집단의 모형을 대상으로 6개의 계측 거리를 지정한 후 측정하였다. 통계분석은 비모수 검정법인 윌콕슨 순위 합 검정법을 이용하여 비교 분석하였다(제1종 오류수준=0.05). 비록 모든 부위에서 디지털 모형이 석고 모형보다 작은 것으로 분석되었으나(p<0.05), 임상적 허용 수치를 벗어나지 않았다.

인상 스캐닝 방법에 의해 제작된 디지털 치과 모형의 체적 안정성 평가 (Evaluation of Dimensional Stability of Digital Dental Model Fabricated by Impression Scanning Method)

  • 김재홍;김기백
    • 치위생과학회지
    • /
    • 제14권1호
    • /
    • pp.15-21
    • /
    • 2014
  • 본 연구에서는 구강으로부터 채득된 인상체를 스캐닝하여 디지털 모형을 제작하였을 때 제작된 디지털 모형의 체적 안정성을 평가하고자 하였다. 그리하여 환자의 구강을 가정한 상악 모형을 본 모형으로 채택하였다. 본 모형과 동일한 증례의 연구 모형을 치과용 석고를 이용하여 총 20개의 석고 모형을 제작하였다. 제작된 연구 모형 20개를 치과용 기성 트레이와 두 종류의 치과용 인상재를 이용하여 20개 연구 모형을 대상으로 20개의 인상을 채득하였다. 채득된 20개의 인상체를 치과용 스캐너로 스캐닝하는 방식으로 디지털 모형으로 변환하였다. 체적 안정성을 평가하기 위하여 6개의 대표 지점을 선정한 뒤 디지털 모형과 함께 디지털 모형의 근간인 석고 모형을 계측하였다. 그 결과 계측된 모든 부위에서 디지털 모형이 석고 모형보다 체적이 작은 것으로 조사되었고, 이는 통계적으로 유의하였다(p<0.05). 이러한 결과들로 추론하여 보았을 때 환자의 구강으로부터 채득된 인상체를 스캐닝하여 제작한 디지털 모형의 체적은 환자의 구강보다 작다는 것을 알 수 있었다. 그러나 이 차이는 미비한 것으로 여러 선행 연구 결과들을 근거로 하였을 때 임상적으로 허용이 가능한 것으로 생각된다.

DLP 공정을 이용한 정밀 치아모델 제작에서 UV 조사량과 후경화 수축률의 상관관계 분석 (Correlation between UV-dose and Shrinkage amounts of Post-curing Process for Precise Fabrication of Dental Model using DLP 3D Printer)

  • 신동훈;박영민;박상후
    • 한국기계가공학회지
    • /
    • 제17권2호
    • /
    • pp.47-53
    • /
    • 2018
  • Nowadays, additive manufacturing (AM) technology is a promising process to fabricate complex shaped devices applied in medical and dental services. Among the AM processes, a DLP (digital light processing) type 3D printing process has some advantages, such as high precision, relatively low cost, etc. In this work, we propose a simple method to fabricate precise dental models using a DLP 3D printer. After 3D printing, a part is commonly post-cured using secondary UV-curing equipment for complete polymerization. However, some shrinkage occurs during the post-curing process, so we adaptively control the UV-exposure time on each layer for over- or under-curing to change the local shape-size of a part in the DLP process. From the results, the shrinkage amounts in the post-curing process vary due to the UV-dose in 3D printing. We believe that the proposed method can be utilized to fabricate dental models precisely, even with a change of the 3D CAD model.