• Title/Summary/Keyword: Digital complete dentures

Search Result 27, Processing Time 0.02 seconds

Evaluation of trueness of maxillary and mandibular denture bases produced with a DLP printer by immersion in a constant temperature water bath (DLP 프린터로 제작한 상악 및 하악 의치상의 항온수조 침적에 따른 진실도(trueness) 평가)

  • Dong-Yeon Kim;Gwang-Young Lee
    • Journal of Technologic Dentistry
    • /
    • v.46 no.2
    • /
    • pp.28-35
    • /
    • 2024
  • Purpose: To evaluate the three-dimensional trueness of upper and lower denture bases produced using a digital light processing (DLP) printer and immersed in a constant-temperature water bath. Methods: An edentulous model was prepared and fitted with denture bases and occlusal rims manufactured using base plate wax. After scanning the model, denture bases, and occlusal rims, complete denture designs were created. Using the designs and a DLP printer, 10 upper and 10 lower complete dentures were manufactured. Each denture was scanned before (impression surface of upper denture base before constant temperature water bath [UBC] and impression surface of lower denture base before constant temperature water bath [LBC] groups) and after (impression surface of upper denture base after constant temperature water bath [UAC] and impression surface of lower denture base after constant temperature water bath [LAC] groups) immersion in the constant-temperature water bath. Scanned files were analyzed by comparing reference and scanned data, with statistical analysis conducted using the Kruskal-Wallis test (α=0.05). Results: Statistical analysis revealed no significant differences between the UBC and LBC groups, nor between the UAC and LAC groups (p>0.05). However, significant differences were observed between the UBC and UAC groups and between the LBC and LAC groups, i.e., before and after the constant-temperature water bath for both maxillary and mandibular denture bases (p<0.05). Conclusion: Denture bases not immersed in the constant-temperature water bath (UBC and LBC groups) exhibited error values within 100 ㎛, whereas those immersed in the water bath (UAC and LAC groups) showed error values exceeding 100 ㎛.

Effect of polymerization method and fabrication method on occlusal vertical dimension and occlusal contacts of complete-arch prosthesis

  • Lima, Ana Paula Barbosa;Vitti, Rafael Pino;Amaral, Marina;Neves, Ana Christina Claro;Concilio, Lais Regiane da Silva
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.2
    • /
    • pp.122-127
    • /
    • 2018
  • PURPOSE. This study evaluated the dimensional stability of a complete-arch prosthesis processed by conventional method in water bath or microwave energy and polymerized by two different curing cycles. MATERIALS AND METHODS. Forty maxillary complete-arch prostheses were randomly divided into four groups (n = 10): MW1 - acrylic resin cured by one microwave cycle; MW2 - acrylic resin cured by two microwave cycles: WB1 - conventional acrylic resin polymerized using one curing cycle in a water bath; WB2 - conventional acrylic resin polymerized using two curing cycles in a water bath. For evaluation of dimensional stability, occlusal vertical dimension (OVD) and area of contact points were measured in two different measurement times: before and after the polymerization method. A digital caliper was used for OVD measurement. Occlusal contact registration strips were used between maxillary and mandibular dentures to measure the contact points. The images were measured using the software IpWin32, and the differences before and after the polymerization methods were calculated. The data were statistically analyzed using the one-way ANOVA and Tukey test (${\alpha}=.05$). RESULTS. The results demonstrated significant statistical differences for OVD between different measurement times for all groups. MW1 presented the highest OVD values, while WB2 had the lowest OVD values (P<.05). No statistical differences were found for area of contact points among the groups (P=.7150). CONCLUSION. The conventional acrylic resin polymerized using two curing cycles in a water bath led to less difference in OVD of complete-arch prosthesis.

Fabrication of complete dentures made with monolithic discs through CAD/CAM using facial scan data and individual tray duplicating temporary denture: a case report (안면스캔 데이터와 임시의치를 복제한 개인 트레이를 활용하여 CAD/CAM을 통한 monolithic disc로 제작한 총의치 수복: 증례 보고)

  • Ju Hyun Kim;Soo-Yeon Shin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.39 no.3
    • /
    • pp.158-167
    • /
    • 2023
  • As digital technology has advanced in the field of dentistry, the use of computer-aided design/computer-aided manufacturing (CAD/CAM) has brought changes to the stages of dental treatment. The use of CAD/CAM technology in dental restoration offers clinical efficiency and convenience by reducing production time and appointment intervals, while also simplifying the fabrication process to reduce errors. In this case, digital replication and printing of temporary teeth were used to aid a patient with complex medical histories and physical disabilities. The final impression obtained with silicone impression material included information on the vertical dimension, centric relation, and the angle and length of the anterior teeth, which shortened the production time and appointment intervals and increased patient satisfaction. The final restoration was fabricated using milling and monolithic disc techniques, demonstrating appropriate stability, retention, and support, resulting in functional and aesthetic satisfaction.

Assessment of swallowing and masticatory performance in obturator wearers: a clinical study

  • Vero, Nungotso;Mishra, Niraj;Singh, Balendra Pratap;Singh, Kamleshwar;Jurel, Sunit Kumar;Kumar, Vijay
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.1
    • /
    • pp.8-14
    • /
    • 2015
  • PURPOSE. To assess function by identifying changes in swallowing and masticatory performance in maxillary obturator prosthesis wearers. MATERIALS AND METHODS. Sixty subjects were recruited for the study, of which 20 were obturator wearers, 20 were completely dentulous and 20 had removable partial/complete dentures with similar Eichner's Index. Swallowing ability was evaluated with and without obturator using the "Water Drinking Test"; Masticatory performance was evaluated with the Sieve test; and maximum occlusal force was recorded with the help of a digital bite sensor. The data was analyzed using the Statistical Package for Social Science version 15.0 with a confidence level at 95%. RESULTS. Profile, behavior of drinking and time taken to drink were significantly improved (P<.001) in subjects after wearing obturator. Masticatory performance was not significantly different (P=.252) in obturator wearer when compared with dentulous or removable partial/complete denture wearer, but significantly (P<.001) high inter group difference in maximum occlusal force existed. Correlation between masticatory performance and maximum occlusal force was not significant (P=.124). CONCLUSION. Swallowing ability was significantly improved after wearing obturator but masticatory performance was not significantly different from those having similar occlusal support zone in their dentition.

Rational treatment planning for implant treatment of the edentulous patients (완전무치악환자의 전악 임플란트 치료 계획 수립을 위한 체계적인 접근법)

  • Jeong-In Bae
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.32 no.2
    • /
    • pp.54-68
    • /
    • 2023
  • Treatment planning of edentulous patient with digital method is materialized by designing the surgical guide. When designing the surgical guide, we first implement the shape of the final prosthesis in the virtual space and then materialize the implantation plan based on this. However, it is challenging to make surgical guides for edentulous patients as their lack of both the reference for the arrangement of teeth and interocclusal relationship makes it hard to envision the shape of the final prosthesis. If there exists good partial or complete dentures or residual teeth, its teeth arrangement can be used as a reference for the virtual final prosthesis and the subsequent surgical guide. If such a reference is absent or unsatisfactory, a process of manufacturing a complete denture for diagnostic purposes and verifying it on patient's mouth is necessary and use it as a new reference for the virtual final prosthesis. But even if a surgical guide is produced through the reference from the thorough reflection of the virtual final prosthesis, when we use it in the surgical field, the intraoral condition of the patient may make the implants deviated from planned in the surgical guide. In the worst case, if the positioning of the surgical guide on the mouth is incorrect, it can lead to a catastrophic error that displaces all the implant, in which case the guided surgery would be much worse than the non-guided one. In this article, we will discuss how to obtain references of tooth arrangements in a timely manner and align or register them into a unified coordinate system in digital space, and also introduce how to transfer such an implantation plan from the virtual world into the patient's mouth of real world with minimum error. And lastly, I would like to express my opinion on the establishment of a rational and systematic protocol of guided surgery of the edentulous patients.

From TMJ to 3D Digital Smile Design with Virtual Patient Dataset for diagnosis and treatment planning (가상환자 데이터세트를 기반으로 악관절과 심미를 고려한 진단 및 치료계획 수립)

  • Lee, Soo Young;Kang, Dong Huy;Lee, Doyun;Kim, Heechul
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.30 no.2
    • /
    • pp.71-90
    • /
    • 2021
  • The virtual patient dataset is a collection of diagnostic data from various sources acquired from a single patient into a coordinate system of three-dimensional visualization. Virtual patient dataset makes it possible to establish a treatment plan, simulate various treatment procedures, and create a treatment planning delivery device. Clinicians can design and simulate a patient's smile on the virtual patient dataset and select the optimal result from the diagnostic process. The selected treatment plan can be delivered identically to the patient using manufacturing techniques such as 3D printing, milling, and injection molding. The delivery of this treatment plan can be linked to the final prosthesis through mockup confirmation through provisional restoration fabrication and delivery in the patient's mouth. In this way, if the diagnostic data superimposition and processing accuracy during the manufacturing process are guaranteed, 3D digital smile design simulated in 3D visualization can be accurately delivered to the real patient. As a clinical application method of the virtual patient dataset, we suggest a decision-making method that can exclude occlusal adjustment treatment from the treatment plan through the digital occlusal pressure analysis. A comparative analysis of whole-body scans before and after temporomandibular joint treatment was suggested for adolescent idiopathic scoliosis patients with temporomandibular joint disease. Occlusal plane and smile aesthetic analysis based on the virtual patient dataset was presented when treating patients with complete dentures.

Interalveolar ridge crest relation analysis and rehabilitation of edentulous patient using dental CAD software: A case report (치과용 CAD 소프트웨어를 이용한 무치악 환자의 치조제 관계 진단 및 총의치 수복 증례)

  • Hong, Youngsun;Kim, Jong-Eun;Shim, June-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.1
    • /
    • pp.31-36
    • /
    • 2019
  • As the number of elderly population increases, the proportion of edentulous patients is increasing, and the demand for traditional dentures will also increase. Arranging the artificial teeth according to the relationship and shape of the upper and lower alveolar ridge is an important factor increasing the stability of the denture. This case is a 79 year old female patient who wishes to make denture covered by national health insurance for psychological and economical reasons. With the alveolar bone severely atrophic, the dental CAD software was used for accurate diagnosis and the posterior teeth were arranged in a cross bite according to the interalveolar crest line angle by the program. After completion, the denture showed adequate stability and maintenance in periodic examinations and treatment, and the patient also expressed high satisfaction.