• Title/Summary/Keyword: Digital X-ray image

Search Result 301, Processing Time 0.025 seconds

A Design of Digital CMOS X-ray Image Sensor with $32{\times}32$ Pixel Array Using Photon Counting Type (포톤 계수 방식의 $32{\times}32$ 픽셀 어레이를 갖는 디지털 CMOS X-ray 이미지 센서 설계)

  • Sung, Kwan-Young;Kim, Tae-Ho;Hwang, Yoon-Geum;Jeon, Sung-Chae;Jin, Seung-Oh;Huh, Young;Ha, Pan-Bong;Park, Mu-Hun;Kim, Young-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.7
    • /
    • pp.1235-1242
    • /
    • 2008
  • In this paper, x-ray image sensor of photon counting type having a $32{\times}32$ pixel array is designed with $0.18{\mu}m$ triple-well CMOS process. Each pixel of the designed image sensor has an area of loot $100{\times}100\;{\mu}m2$ and is composed of about 400 transistors. It has an open pad of an area of $50{\times}50{\mu}m2$ of CSA(charge Sensitive Amplifier) with x-ray detector through a bump bonding. To reduce layout size, self-biased folded cascode CMOS OP amp is used instead of folded cascode OP amp with voltage bias circuit at each single-pixel CSA, and 15-bit LFSR(Linear Feedback Shift Register) counter clock generator is proposed to remove short pulse which occurs from the clock before and after it enters the counting mode. And it is designed that sensor data can be read out of the sensor column by column using a column address decoder to reduce the maximum current of the CMOS x-ray image sensor in the readout mode.

The Comparison of X-ray Response Characteristics of Vacuum Evaporated (진공증착된 CdTe와 $Cd_{0.85}Zn_{0.15}Te$ 필름의 X선 반응특성 비교)

  • Kang, S.S.;Choi, J.Y.;Cha, B.Y.;Moon, C.W.;Kim, J.H.;Nam, S.H.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.845-848
    • /
    • 2002
  • The study of photoconductor materials is demanded for development for flat-panel digital x-ray Imager. In this paper, We investigated the feasibility of application as x-ray image sensor using Cd(Zn)Te compound with high stopping power on high radiation. These Cd(Zn)Te samples were fabricated by vacuum thermal evaporation method to large area deposition and investigated I-V measurement as applied voltage. The experimental results show that the additional injection Zn in CdTe film reduced the leakage current, for the $Cd_{0.85}Zn_{0.15}Te$ detector, the net charge had the highest value as $144.58pC/cm^2$ at 30 V.

  • PDF

A Study on the Parallel Processing Architecture for the Real Time Image Reconstruction of X-ray CT (X-ray CT의 실시간 영상재구성을 위한 병렬처리 구조에 관한 연구)

  • Jin, Seung-Oh;Heo, Chang-Won;Huh, Young
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3153-3155
    • /
    • 1999
  • 최근 수년간 의료영상분야는 국내외적으로 급격한 발전을 거듭하고 있다. 특히 자기공명영상장치 (Magnetic Resonance Imaging), X-ray CT(Computed Tomography)와 단층촬영장치는 인체내부를 비침습적(non-invasive)으로 영상화함으로써 해부학적인 질병진단에 많은 장점을 가지고 있다. 이와같은 단층영상 재구성에는 역매트릭스법(matrix inversion). 반복재구성법(interative method), 역투영 법(back-projection), 2차원 Fourier 변환법(2D FFT), 중첩재구성법(Filtered back-projection) 등의 다양한 알고리즘을 사용하고 있다. 본 연구에서는 X-ray CT에서의 단층영상재구성 기법 중 널리 사용되고 있는 Filtered Back Projection 기법의 연산순서도와 연산량을 분석하고 이를 시뮬레이션을 통하여 확인하고 실시간 영상재구성을 위하여 범용 Digital Signal Processor의 병렬처리시스템 구성에 기반된 최적 Architecture를 선정하고자 한다.

  • PDF

The Effect of X-ray Tube Potential on the Image Quality of Digital Chest Radiography with an Amorphus Silicon Flat Panel Detectors (비정질 평판형 측정기를 이용한 디지털 흉부 방사선 영상에서의 효과적인 관전압 선택)

  • Kim, Jung-Min;Im, Eun-Kyung
    • Journal of radiological science and technology
    • /
    • v.28 no.4
    • /
    • pp.273-277
    • /
    • 2005
  • The rapid development in digital acquisition technology in radiography has not been accompanied by information regarding optimum radiolographic technique for use with an amorphus silicon flat panel detector. The purpose of our study was to compared image quality and radiation dose of an amorphus silicon flat panel detectors for digital chest radiography. All examinations were performed by using an amorphus silicon flat panel detector. Chest radiographs of an chest phantom were obtained with peak kilovoltage values of $60{\sim}150kVp$. Published data on the effect of x-ray beam energy on image quality and patient dose when using an amorphus silicon flat panel detector. It is important that radiographers are aware of optimum kVp selection for an amorphus silicon flat panel detector system, particularly for the commonly performed chest examination.

  • PDF

Experimental research on blood sucking phenomena of a female mosquito (암모기 흡혈과정에 대한 실험적 연구)

  • Kim, Bo-Heum;Lee, Jung-Yeop;Lee, Sang-Joon
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.105-106
    • /
    • 2008
  • As a carrier of malaria and sneak of blood, mosquitoes are an unpleasant insect. However, there are several unknown natural secretes related with mosquitoes. Among them, we focused on the blood sucking process of a female mosquito. The main objective of this study is to understand the mosquito's blood sucking mechanism that can be used to resolve the problem encountered in the injection or transport of infinitesimal biological fluids in a micro-chip. At first, the velocity fields of blood-sucking flow in a proboscis were measured using a micro-particle image velocimetry (PIV) technique. The velocity signals of flow in the proboscis show periodic variation. This seems to be resulted from the beating of the pharyngeal pump which works as driving power. To analyze the pumping mechanism, the temporal variation of the pharyngeal pump was visualized using the synchrotron X-ray micro-imaging technique. The volume variation was estimated by the help of digital image processing techniques. Once the main mechanism of blood sucking process was found, a effective micro-pumping system with high efficiency would be developed in near future.

  • PDF

The Effects of Total Variation (TV) Technique for Noise Reduction in Radio-Magnetic X-ray Image: Quantitative Study

  • Seo, Kanghyen;Kim, Seung Hun;Kang, Seong Hyeon;Park, Jongwoon;Lee, Chang Lae;Lee, Youngjin
    • Journal of Magnetics
    • /
    • v.21 no.4
    • /
    • pp.593-598
    • /
    • 2016
  • In order to reduce the amount of noise component in X-ray imaging system, various reduction techniques were frequently used in the field of diagnostic imaging. Although the previous techniques -such as median, Wiener filters and Anscombe noise reduction technique - were able to reduce the noise, the edge information was still damaged. In order to cope with this problem, total variation (TV) noise reduction technique has been developed and researched. The purpose of this study was to evaluate and compare the image quality using normalized noise power spectrum (NNPS) and contrast-to-noise ratio (CNR) through simulations and experiments with respect to the above-mentioned noise reduction techniques. As a result, not only lowest NNPS value but also highest CNR values were acquired using a TV noise reduction technique. In conclusion, the results demonstrated that TV noise reduction technique is proved as the most practical method to ensure accurate denoising in X-ray imaging system.

Simulation of the Digital Image Processing Algorithm for the Coating Thickness Automatic Measurement of the TRISO-coated Fuel Particle

  • Kim, Woong-Ki;Lee, Young-Woo;Ra, Sung-Woong
    • Journal of Information Processing Systems
    • /
    • v.1 no.1 s.1
    • /
    • pp.36-40
    • /
    • 2005
  • TRISO (Tri-Isotropic)-coated fuel particle is widely applied due to its higher stability at high temperature and its efficient retention capability for fission products in the HTGR (high temperature gas-cooled reactor), one of the highly efficient Generation IV reactors. The typical ball-type TRISO-coated fuel particle with a diameter of about 1 mm is composed of a nuclear fuel particle as a kernel and of outer coating layers. The coating layers consist of a buffer PyC, inner PyC, SiC, and outer PyC layer. In this study, a digital image processing algorithm is proposed to automatically measure the thickness of the coating layers. An FBP (filtered backprojection) algorithm was applied to reconstruct the CT image using virtual X-ray radiographic images for a simulated TRISO-coated fuel particle. The automatic measurement algorithm was developed to measure the coating thickness for the reconstructed image with noises. The boundary lines were automatically detected, then the coating thickness was circularly by the algorithm. The simulation result showed that the measurement error rate was less than 1.4%.

Development of Dual Energy Radiation Detector (이중 에너지 방사선 검출기 개발)

  • Yeo, Hwa-Yeon
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.3
    • /
    • pp.5-11
    • /
    • 2010
  • In this paper, we are suggested development of dual-mode detector for dual-energy digital radiography. Design of dual-energy radiography module for commercial BIS (Baggage Inspection System) is used in the spectrum of the X-ray generator and detector for dual-mode features and radiological characteristics were analyzed. BIS suggestl on the image detector module being used to target X-ray tube to simulate X-ray spectrum and simulated spectrum to offer through the new radiographic characteristics of the detector modules were investigated. Using X-ray experiments with an increase in the thickness of the copper filter low energy detector (LED) and high-energy detector (HED) as the difference between the output signal increases. HED, especially in the size of the output signal decreases with increasing thickness of the copper filter was found.

Evaluation of the Spatial Resolution for Exposure Class in Computed Radiography by Using the Modulation Transfer Function (변조전달함수를 이용한 컴퓨터 방사선영상의 감도 노출 분류에 따른 공간분해능 평가)

  • Seoung, Youl-Hun
    • Journal of Digital Convergence
    • /
    • v.11 no.8
    • /
    • pp.273-279
    • /
    • 2013
  • The purpose of the study was to present basic data to evaluation of the spatial resolution for exposure class(EC) in computed radiography(CR) by using the modulation transfer function(MTF). In this study, MTF was measured the edge method by using image plate(IP) of $100{\mu}mm$ pixels. A standard beam quality RQA5 based on an international electro-technical commission(IEC) standard was used to perform the X-ray imaging studies. Digital imaging began to set the sensitivity to EC 50, 100, 200, 300, 400, 600, 800, 1200 in X-ray irradiated to IP. The MTF 50% and 10% in the final images was analysis by using an authorized image analysis program the Origin 8.0 and the image J. As a results, the EC 200 was the best spatial resolution at MTF 50% ($1.979{\pm}0.114lp/mm$) and MTF 10% ($3.932{\pm}0.041$). Therefore, the EC 200 could be useful for the diagnosis of diseases that require high spatial resolution such as fractures.