• 제목/요약/키워드: Digital X-ray System

검색결과 225건 처리시간 0.027초

Time-Phased Implementation of a Large-Scale PACS at Samsung Medical Center

  • 노덕우;최형식;임재훈;김원기
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1994년도 추계학술대회
    • /
    • pp.26-27
    • /
    • 1994
  • The first step implementation of a hospital-wide Picture Archiving Communications System (PACS) at a newly built hospital Samsung Medical Center (SMC), is described. Current clinical operation encompasses the fiber optics delivery of direct-interfaced magnetic resonance imager (LRI), X-ray computed tomography (CT). digital subtraction angiography (DSA) and computed radiography (CR) digital images via high performance file server to the departments of radiology, neurosurgery, orthopedics surgery, neurology, emergency room and the surgical intensive care unit.

  • PDF

$BrO_2/a-Se$ 구조의 방사선 변환센서에서 a-Se에 첨가된 조성비 변화에 따른 I-V 특성 비교 (Comparison of the I-V Characteristic as Various Composition ratio of Iodine in a-Se of $BrO_2/a-Se$ based Radiation Conversion Sensor)

  • 최장용;박지군;공현기;안상호;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.440-443
    • /
    • 2002
  • Present1y the X-Ray diagnosis system is a real condition that is changing by digital ways in it's existent analog ways. This digital radiation detector is divided by the direct method and the indirect method. The indirect method of applied voltage has special qualities that the resolution is low than direct method by diffusion effect that happens. The conversion process ( radiation${\rightarrow}$visible ray${\rightarrow}$electrical signal of two times, has shortcomings that the energy conversion efficiency of electrical signal is low. The direct method has shortcomings that need strong electric fie1d to detect electrical signal efficiently. This research achieved to develop digital detector of the Hybrid method that have form that mixes two ways to supplement shortcoming of direct. indirect method. A studied electrical characteristic by Iodine's Mixture ratio change is added to selenium in the detector which has a multi-layer structure (Oxybromide + a-Se). There are 8 kinds of Manufactured compositions to amorphous selenium Iodine each 30ppm, 100ppm, 200 ppm, 300ppm, 400ppm, 500ppm, 600ppm, 700ppm by a doped photoconductor through a vacuum thermal evaporation method. The phosphor layer is consisted of Oxybromide ($BrO_2$) which uses optical adhesives multi-layer structure. The manufactured compositions calculates and compares Net Charge and signal to noise ratio measuring Photocurrent about Darkcurrent and X-ray. When doped Iodine Mixture ratio is 500ppm to the multi-layer structure (Oxybromide + a-Se), applied voltage of $3V/{\mu}m$, leakage current of compositions $2.61nA/cm^2$ and net charge value by 764pC/$cm^2$/mR then the best result appeared.

  • PDF

무선 디지털청진기를 이용한 동물 진단시스템 (Animal Diagnosis System Using Wireless Digital Stethoscope)

  • 박기영;홍수미;이종하;박진호;정의붕
    • 한국통신학회논문지
    • /
    • 제38B권9호
    • /
    • pp.722-727
    • /
    • 2013
  • 동물 의료는 병의 정도나 치료의 필요성에 관계없이 보호자의 의향이 앞서는 어려운 의료행위이다. 특히, 동물치료 중 심장 질환은 필요한 치료법의 결정이나 치료 효과의 확인에 대해서 동물 환자로부터 직접적인 답을 얻기가 어렵다. 그래서 동물 환자의 경우, 심장질환은 증상의 악화로 급변하거나 돌연사 등의 응급사태를 예측하고 그것에 대처하는 것은 거의 불가능하다. 심장 및 몸 안의 질환을 확인하는 1차 진단 방법은 청진이다. CT나 X-ray, 초음파 등의 최첨단 영상장비들을 이용하여 정확하게 측정할 수 있지만 장비가 비싸고, 이를 활용할 수 있는 전문인력이 요구되는 등 경제성으로 인해 2차 진단장비로 활용되어질 뿐 1차 진단을 위한 가장 좋은 진단도구로 여전히 청진기가 이용되어지고 있다. 본 논문에서는 수의사가 귀에 대지 않고 청진음을 분석하고 무선으로 어디서나 진단 할 수 있는 무선디지털 진단시스템에 대해 자세하게 서술하고, 이 시스템을 통해 진단되는 청진음에 대한 레벨교차율(LCR)과 에너지레벨을 통해 질병의 관계에 대해 새로운 개념의 진단시스템 환경을 제시한다.

Glass Dosimeter를 이용한 환자피폭선량에 관한 분석 (Analysis of Patient Exposure dose with Glass Dosimeter)

  • 김재인;최원근;장성원;오창섭;이관섭;하동윤
    • 대한디지털의료영상학회논문지
    • /
    • 제11권1호
    • /
    • pp.15-20
    • /
    • 2009
  • Far reducing medical radiation exposure and managing patient doses, Entrance surface doses(ESDs) were measured at Diagnostic Radiology Department in ASAN medical center, also we determined and compared with the Diagnostic Reference Level(DRL) of some other countries. ESDs were measured far the most common types of X-ray procedures, such as chest PA, lumbar spine AP, lumbar spine lateral, Pelvis AP, Skull PA. ESDs were measured by Glass dosimeter and Unfors Xi meter. Those were applied collimation center of phantom's entrance skin surface. The results of ESDs were compared Glass dosimeter with Unfors Xi meter. Those were measured within 5% statistical difference. It seemed well agreement at two devices. In most cases ESDs measured far the different types of X ray procedures were found to be lower than the DRL of IAEA, but ESDs on chest PA, lumbar spine AP, lumbar spine lateral, Pelvis AP, Skull PA were proximity ar excesses at DRL of advanced country. Through this study, we need an investigation and improvement at present diagnostic radiology exam system. Also, radiologists make an effort to reduce patient dose and having a technical skill.

  • PDF

외부영상정보 입력 시 DICOM정보 충실성에 대한 평가 - DICOM Validation Tool 이용 - (The Evaluation about the Information Fidelity in the External Image Information Input - Using DICOM Validation Tool -)

  • 이송우;이호연;도지훈;장혜원
    • 대한디지털의료영상학회논문지
    • /
    • 제13권1호
    • /
    • pp.33-38
    • /
    • 2011
  • Now a days, there's many change over for PACS among the most of hospital and it standard for DICOM 3.0. These kind of using of DICOM 3.0 improves increasing of medical imaging exchange and service for patient. However, there's some problems of compatibility caused during carry out CD and DVD from hospital. For this reason, this thesis analyzed patients image targeting those storages requested to hospitals in Seoul by using Validation Toolkit which is recommended from KFDA. The analyze type is like this. Make 100 data, total 500, each of MRI CT Plain x-ray Ultrasound PET-CT images and analyzed type of error occurred and loyalty of information. If express percentage of error occurred statistically, we can get a result as follows MRI 5%, Plain x-ray 11%, CT 18%, US 25%, PET-CT 30%. The reson why percentage of error occurred in PET-CT is because of imperfective support and we could notice that we weren't devoted to information. Even though, PET-CT showed highest percentage of error occurred, currently DICOM data improved a lot compare to past. Moreover, it should be devoted to rule of IHE TOOL or DICOM. In conclusion, we can help radiographer to analyze information of image by providing clues for solving primary problem and further more, each of PACS company or equipment company can enhance fidelity for following standard of image information through realizing the actual problem during transfer of image information.

  • PDF

Investigation of molten fuel coolant interaction phenomena using real time X-ray imaging of simulated woods metal-water system

  • Acharya, Avinash Kumar;Sharma, Anil Kumar;Avinash, Ch.S.S.S.;Das, Sanjay Kumar;Gnanadhas, Lydia;Nashine, B.K.;Selvaraj, P.
    • Nuclear Engineering and Technology
    • /
    • 제49권7호
    • /
    • pp.1442-1450
    • /
    • 2017
  • In liquid metal fast breeder reactors, postulated failures of the plant protection system may lead to serious unprotected accidental consequences. Unprotected transients are generically categorized as transient overpower accidents and transient under cooling accidents. In both cases, core meltdown may occur and this can lead to a molten fuel coolant interaction (MFCI). The understanding of MFCI phenomena is essential for study of debris coolability and characteristics during post-accident heat removal. Sodium is used as coolant in liquid metal fast breeder reactors. Viewing inside sodium at elevated temperature is impossible because of its opaqueness. In the present study, a methodology to depict MFCI phenomena using a flat panel detector based imaging system (i.e., real time radiography) is brought out using a woods metal-water experimental facility which simulates the $UO_2-Na$ interaction. The developed imaging system can capture attributes of the MFCI process like jet breakup length, jet front velocity, fragmented particle size, and a profile of the debris bed using digital image processing methods like image filtering, segmentation, and edge detection. This paper describes the MFCI process and developed imaging methodology to capture MFCI attributes which are directly related to the safe aspects of a sodium fast reactor.

XRF시스템용 효율적인 Trapezoidal 필터 및 최대값 검출 회로 설계 (Design of Efficient Trapezoidal Filter and Peak Value Detection Circuit for XRF Systems)

  • 박철암;정진균
    • 전자공학회논문지
    • /
    • 제50권6호
    • /
    • pp.138-144
    • /
    • 2013
  • XRF 시스템에서 디지털 방식으로 펄스를 합성하는 기술은 현재 다양하게 발전 되면서 기존의 아날로그 방식을 대신하고 있다. XRF 시스템에서는 펄스의 높이를 분석하기 위해 주로 trapezoidal 필터를 사용한다. 본 논문에서는 trapezoidal 필터의 하드웨어 구현을 위한 효율적인 구조를 제안한다. 또한 측정 오차가 기존 알고리즘에 의한 오차의 절반으로 감소되면서 효율적인 하드웨어 구현이 가능한 최대값 검출 알고리즘을 제안한다. 제안한 알고리즘은 하드웨어 언어인 Verilog HDL로 설계하고 FPGA로 구현하였으며 테스트보드를 제작하여 성능을 검증하였다.

화물 검색시스템 구현 및 Boundary_Scan Test (Cargo Inspection System Design and Boundary-Scan Test)

  • 김봉수;김인수;유선원;김성원;이선화;이윤;한범수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.197-200
    • /
    • 2002
  • We newly developed the procedures of X-ray Cargo inspection system with acquisition of multi-channel data, analog to digital converter and post logic circuit which is controlled by the FPGA. The IEEE1149.1 standard defines a four-wire serial interface(a fifth wire is optional)to access complex integrated circuits(ICs) such as PLD. This paper describes that Boundary_Scan test method applied to our home made cargo inspection system.

  • PDF

컴퓨터 방사선영상시스템에서 비감도를 이용한 영상판의 상대적 발광량 평가 (Evaluation of Relative Emission of Image Plate by Using Relative Sensitivity in Computed Radiography System)

  • 성열훈
    • 한국콘텐츠학회논문지
    • /
    • 제14권11호
    • /
    • pp.355-361
    • /
    • 2014
  • 본 연구의 목적은 필름/증감지 방식에서 사용된 비감도 측정 방식을 이용하여 컴퓨터 방사선영상에서 영상판의 상대적 발광량을 평가하고자 하였다. 비감도 측정을 위한 특성곡선은 균일한 알루미늄으로 구성된 11 계단의 투과도계를 이용하였다. 디지털 방사선영상을 획득하기 위한 X선 조사조건은 50 kVp, 10 mAs로 조절했다. 영상후처리 알고리즘(MUSICA)의 모든 파라메터들은 제로화하여 원본 데이터에 근사화하였고 레이저 조사분류(exposure class)는 200으로 고정하였다. 영상판의 상대적 발광량 모델링은 X선 조사후 0, 4, 8, 12, 24 시간 보관한 영상판을 이용하였다. 그 결과, 컴퓨터 방사선영상시스템의 영상판 비감도 측정에 필요한 감도점 농도는 모든 특성곡선을 상대적으로 측정하기 용이한 2000 픽셀(pixel) 값이 적합하였다. 또한 영상판의 비감도가 저하될 때 영상신호를 생성하기 위한 빛 발광량도 감소하였다. 본 연구에서 제시한 비감도 평가방법은 컴퓨터 방사선영상시스템에서 영상판의 상대적 발광량을 평가할 수 있는 기술로 활용될 수 있을 것이다.

CR과 DR 영상화질의 정량적 비교분석 (Quantitative Analysis and Comparison of DR and CR image quality)

  • 박혜숙;서장연;정진화;이창래;조효민;김희중
    • 한국방사선학회논문지
    • /
    • 제1권1호
    • /
    • pp.31-37
    • /
    • 2007
  • 본 연구의 목적은 CR(Computed Radiography)과 DR(Digital Radiography)장비의 각 Detector를 통해 획득된 영상의 화질을 비교 분석하기 위한 것이다. CR(AGFA MD 4.0 General plate, JAPAN)과 DR(HOLOGIC nDirect Ray, USA)에 대한 영상평가의 주요인자인 MTF(Modulation transfer function), NPS(Noise power spectrum), Photon fluence, DQE(Detective quantum efficiency)를 정량적인 값으로 도출하여 비교한 결과 CR이 DR보다 우수하게 나타났다. 본 연구의 결과는 CR과 DR장비의 Image quality를 정량적으로 평가할 수 있을 뿐만 아니라 이 장비들을 유지, 보수하는데도 도움이 될 것으로 사료된다.

  • PDF