• Title/Summary/Keyword: Digital Treatment

Search Result 1,099, Processing Time 0.033 seconds

Algorithm development of automatic symptom degree for Patient with Hallux Valgus (무지외반증 환자의 증상정도의 자동분류 알고리즘 개발)

  • Han, Hyun-Ji;Lee, Sang-Sik
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.4 no.2
    • /
    • pp.96-102
    • /
    • 2011
  • In this study, we performed algorithm development of automatic symptom degree for patient with hallux valgus one of the representative foot disease of morden. And this study proposes an efficient automated technique that is different from the original analog diagnosis for treatment and surgery of hallux valgus using digital image process. And we used X-Ray images of both a normal and a patient with hallux valgus in the procedure. First, we marked the standard angle on the X-Ray image of normal through Overlap & Add technique. Then we created a standard image through thinning filter and roberts filter(edge detection algorithm). Second, we used sobel filter of edge detection algorithm on the X-Ray image of patient. Moreover, we went another overlap & add technique procedure with both normal and patient image that we made. With the output, we projected the display detection image onto the screen. Finally, with the display detection image, we could measure and project the diagnosis angle of hallux valgus. And this confirms that this method is much more practical and applicable for another orthopedics disease than the prior one.

The Similarity of the Image Comparison System utilizing OpenCV (OpenCV를 활용한 이미지 유사성 비교 시스템)

  • Ban, Tae-Hak;Bang, Jin-Suk;Yuk, Jung-Soo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.834-835
    • /
    • 2016
  • In recent years, advances in technology, IT is rapidly growing. Accordingly, real time image processing and multiple platforms, providing compatibility with OpenCV for image processing technology research on actively in progress. At present, different, comparing the images to determine the similarity is low, the system will match the rate of people using the analogue figures to determine the system is for the most part. In this paper, Template Matching of OpenCV and Feature Matching utilizing different images to determine the similarity between digital values for the system. A comparison of the features of a specific point on the screen the image to extract the same feature in a different size, you can compare the features of the target image recognized as compared to three historic castle in comparison, verification. This is the voice and image recognition and analysis, check the matching rate readings than in Zhengzhou treatment techniques are available. The future of forensic and other image processing technologies for OpenCV studies will be needed to feed.

  • PDF

A study of Quality evaluation for medical linear accelerator using Electronic Portal Imaging (전자포탈영상 (EPI)을 이용한 의료용 선형가속기의 성능평가에 관한 연구)

  • 윤성익;권수일;추성실
    • Progress in Medical Physics
    • /
    • v.9 no.2
    • /
    • pp.105-113
    • /
    • 1998
  • Accurate radiation dosimetric characters is very important to determine of dose to a radiotherapeutic patient. Medical linear accelerators have been developed not only its new quality of convenient operation but also electric moderation. It is reliable to measure more detail physical parameter that linac's internal ability. Typically, radiation dosimetric tool is classified ionization chamber, film, thermoluminescence dosimeter, etc. Nowaday, Electronic Portal Imaging Device is smeared in radiation field to verification of treatment region. EPID's image was focused that using both on-line image verification and absolutely minimum absorbed dose during radiotherapy. So, Electronic Portal Imaging was tested for quality evaluation of medical linear accelerator had its pure conditional flash. This study has performed symmetry, Light/Radiation field congruence, and energy check, geometry difference on wedge filter using a liquid filled ion chamber (EPID). Prior to irradiated on EPID, high energy photon beam is checked with ion chamber. Using these results more convenient dosimetric method is accomplished by EPID that taken digital image. Medical image is acquired with EPID too. Therefore, EPID can be analyzed by numerical information for what want to see or get more knowledge for natural human condition.

  • PDF

Effect of Treatment Conditions of Eco-friendly Fluorinated Water-repellent Agent and Design Applications: Silk Fabrics with DTP Finishing (나노잉크 및 반응성잉크를 사용한 DTP 견직물의 친환경 불소계 발수제에 의한 가공효과 연구)

  • Choi, Kyungme;Kim, Jongjun
    • Journal of Fashion Business
    • /
    • v.18 no.5
    • /
    • pp.159-170
    • /
    • 2014
  • Recent concerns about the PFOA(perfluorooctanoic acid), have been increasing, which is generally applied in the water-repellent finishing process of textile products. It has been proven through animal testing to be harmful to humans, as possible carcinogens and neuro-toxic material. Thus U. S. Environmental Agency has gone as far as requiring the material to be eliminated in its entirety by 2015. As a viable alternative to this water-repellent finishing agent, the development of C6 product is gaining its popularity. The effects of PFOA finishing on the silk fabrics were examined, and we reviewed parameters of the needed process for optimizing appearance and functionality of silk fabrics treated with eco-friendly water-repellent finishing agent. Cross-linking agent affected the most on black color of reactive ink, among the physical properties. The contact angle reading was the highest in $8g/{\ell}$ of concentration for all fabrics. All the fabric specimens, subjected to the DTP and water repellent finishing, exhibited higher stiffness, where rayon specimen showed the highest, compared to the untreated specimens. The results may provide basic information leading to the development of value-added silk fabrics with water-repellency without excessive deterioration of the delicate appearance and inherent soft touch.

A Study on the Cellulose Blend Knit Fabrics using Burn-out Printing Convergence Technology (셀룰로오스 혼방 니트 편포의 착색번아웃 날염복합기술에 관한 연구)

  • Cho, Ho-Hyun;Chung, Myung-Hee;Lee, Jong-Lyel
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.16 no.4
    • /
    • pp.229-235
    • /
    • 2014
  • This study conducted a research on burn-out printing convergence technology for cellulose blend knit fabrics. Printing technology, which forms color pattern on the fabric, can be generally classified into four according to printer or printing method, e.g. screen printing, roller printing, rotary printing, digital printing. However, these printing methods are flat in design or pattern, which have limitation to overcome monotonousness of fabric, so that recently burn-out process method, which expresses three-dimensional pattern effect by treating chemical on the surface of fabric as the method to appeal its esthetics to the customers. Particularly, in case of cellulose/polyester composite material, first, it is proceeded in 2 processes, by dyeing cellulose or polyester fabric and burning out cellulose fabric, in this process, due to pollution caused by disperse dye migration, color of polyester fabric part could be discolored, which has high falt risk. This research considered coloring burn-out technique, which simultaneously proceed dyeing and burn-out by reducing dyeing and burn-out process to 1 stage, which were proceeded in 2 stages previously. As the research result, it was confirmed that reasonable depth of roller was 0.04~0.06mm in roller printing process, heat treatment condition of burn-out far-infrared radiation was $185^{\circ}C{\times}30m/min$. Color fastness to washing was confirmed to be 4-5 grade, color fastness to rubbing, 3-4 grade, color fastness to light, 4 grade. Also, it was confirmed that energy reduction effect appeared 38.19%, in case of energy cost per yard compared to the existing production, also, 19.74%, in case of production cost.

  • PDF

Incidence of Intravascular Penetration during Transforaminal Lumbosacral Epidural Steroid Injection (요부 경추간공 스테로이드 주입 시 혈관천자의 발생률)

  • Kim, Dong Won;Shim, Jae Chol
    • The Korean Journal of Pain
    • /
    • v.20 no.1
    • /
    • pp.26-30
    • /
    • 2007
  • Background: Epidural steroid injections (ESI) are a common treatment for spinal disorders. Previous research has shown that aspiration of the syringe is not a sensitive test for placement of an intravascular needle. Serious complications have been reported from injection of steroids and local anesthetics into the vascular space. In addition to safety concerns, the efficacy may decline with partial injection outside the desired epidural location. We hypothesized that incidence of vascular problems is increased in patients who undergo spine surgery compared with the patients who don't undergo spine surgery. We investigated the incidence of vascular problems during lumbosacral transforaminal ESI and we compared the difference of vascular problems between the patients who undergo spinal surgery and those patients who don't undergo spinal surgery. Methods: Two hundreds and three patients were consecutively recruited and they received 299 fluoroscopically guided lumbosacral transforaminal ESIs. Injection of contrast was performed under live dynamic fluoroscopy with using digital substraction analysis. The observed uptake pattern was classified into one of three categories: flashback, aspirated, and positive contrast with negative flashback and aspiration. Results: The vascular incidence rate was 20.4%. Transforaminal ESIs performed at S1 had avascular incidence rate of 27.8% compared with 17.7% for all the other lumbar injection sites. The sensitivity of spontaneous observation of blood in the needle hub or blood aspirate for predicting an intravascular injection in lumbar transforaminal ESIs was 70.4%. Conclusions: There is a high incidence of intravascular problems when performing transforaminal ESIs, and this is significantly increased in patients with previous spine surgery. Using a flash or blood aspiration to predict an intravascular injection is not sensitive therefore; a negative flash or aspiration is not reliable. Fluoroscopically guided procedures without contrast confirmation are prone to instill medications intravascularly. This finding confirms the need for not only fluoroscopic guidance, but also for contrast injection instillation when performing lumbosacral transforaminal ESIs, and especially for patients with previous spine surgery.

A STUDY OF DETERMINATION OF PHYSIOLOGICAL ROOT APEX BY ELECTRICAL RESISTANCE VALUE (전기저항치에 의한 생리적 근첨(根尖)의 측정에 관한 연구)

  • Yun, Ki-Bock
    • Restorative Dentistry and Endodontics
    • /
    • v.7 no.1
    • /
    • pp.25-31
    • /
    • 1981
  • One of the most important factors for successful endodontic therapy is an accurate length determination of physiological root apex. Some methods suggested for the measurement of root canal length, include digital-tactile sense and roentgenographic technique with measuring wire, scale and grid. But these methods do not derermine an accurate working length to physiological root apex. Recently electronic measuring devices are used to locate the physiological root apex in root canal length determination and these devices are accepted as an effective apparatus. The 89 patients (116 teeth, 144 canals) among the out-patients of Yonsei University Dental Infirmary, who had had an endodontic treatment in the Department of Operative Dentistry, were measured by the Root-Canal Meter$^{(R)}$ as an electronic device, and radiographs to determine the distribution and location of physiological root apex, then the following results were made: (1) Range of ${\pm}$1mm from the radiographic root apex were present in 88.88% (128 canals) of the subjects. (2) Physiological root apex and radiographic root apex were coincided in 31.94% (46 canals) of the subjects. (3) The actual length of the physiological root apex of the teeth were as follow; A : in the maxillary central incisor : 0.46mm B : in the maxillary lateral incisor : 0.44mm C : in the maxillary canine : 0.44mm D : in the maxillary 1st premolar : a) Buccal : 0.59mm b) Lingual : 0.34mm E : in the maxillary 2nd premolar : 0.54mm F : in the maxillary 1st molar : a) Mesio-buccal : 0.50mm b) Disto-buccal : 0.42mm c) Lingual : 0.56mm G : in the mandibular central incisor : 0.62mm H : in the mandibular lateral incisor : 0.45mm in the mandibular canine : 0.54mm J : in the mandibular 1st premolar : 0.47mm K : in the mandibular 2nd premolar : 0.34mm L : in the mandibular 1st molar : a) Mesio-buccal : 0.54mm b) Mesio-lingual : 0.31mm c) Distal : 0.37mm.

  • PDF

Correction of Syndactyly using Pentagonal Flap with Minimal Skin Graft (오각형피판과 최소한의 피부이식을 이용한 합지증의 교정)

  • Bae, Byoung Man;Eo, Su Rak;Kim, In Kyu;Koh, Sung Hoon;Jones, Neil F.
    • Archives of Plastic Surgery
    • /
    • v.34 no.1
    • /
    • pp.64-69
    • /
    • 2007
  • Purpose: The key of treatment in syndactyly is to separate the fused digits safely, and to create a normal web space with enough cutaneous coverage. Despite many techniques have described the correction of syndactyly, skin graft still remains the annoying one. We designed the pentagonal flap from hand dorsum to reconstruct the web space reliably and try to minimize the need for skin graft. Methods: Between July 2003 and August 2005, six cases of syndactyly were corrected at UCLA Medical Center and Hallym University Sacred Heart Hospital using dorsal pentagonal flap for web space reconstruction and straight incisions for the sides of digits to minimize the need for skin graft. The proximal edge of the pentagonal flap was designed in V shape to allow for easy closure of the donor site after advancement. The pentagonal flap was advanced volarly with the underlying dermofat tissues to form a digital web. In some cases, skin defects were unavoidable and covered with full thickness skin graft from the inguinal area. Results: Syndactyly were seen in 4 cases of Apert syndrome, 1 postburn scar webbing with PIP joint contracture and 1 recurrence after the incomplete reconstruction. In all Apert syndrome, straight line incision was used along the sides of the fingers and skin graft was needed. But, in 2 cases of incomplete type, we could save the need for skin graft only for the correction of syndactyly. We could get a good looking web space without any complications such as flap or graft loss. Conclusion: As a modification of Sherif's V-Y dorsal metacarpal flap, we believe pentagonal flap could be one of the easiest and safest way to reconstruct the web space of syndactyly in functional and cosmetic standpoint.

『Yeongchu·Ohseak(靈樞·五色)』 and Physiognomy - Focused on Inspecting Colors - (『영추(靈樞)·오색(五色)』에 대한 상학적(相學的) 고찰(考察) - 오색편(五色篇)과 인상고전(人相古典)에 나오는 찰색(察色) 중심으로 -)

  • Joo, Sun-Hee
    • The Journal of Korean Medical History
    • /
    • v.26 no.1
    • /
    • pp.55-71
    • /
    • 2013
  • Objectives : In physiognomy, human emotion such as joy, anger, sorrow, and pleasure in social relation is one of important factors for impression formation. Various emotional feelings exert significant influence on the endocrine action and the muscle activities as well as changes of one's impression, which results in changes of one's life. On the other hand, such alterations in life may also bring changes of one's impression. The method of physiognomic examination is not different from the inspecting colors that makes a diagnosis of physical conditions. Thus, based on "Yeongchu Ohseak(靈樞 五色)", the present study compares similarities and differences between the two views of the physiognomy and the Korean medicine. Methods : The similarities and differences between the two approaches will be compared to each other and analysed with the respect to inspecting colors suggested by preceding research in physiognomy and "Yeongchu Ohseak(靈樞 五色)". Results & Conclusions : From this study, we found physiognomy and the Korean medicine shares the same theoretical background. The differences that we found in the present study are as follow. The inspection diagnosis in the Korean medicine focuses on the prevention and treatment of diseases; however, physiognomy focuses on the prognostication of one's life in order to lead a happy life. As the ultimate goals of the two approaches differ with each other, it is peculiarly challenging to compare these two in detail. Therefore, the future study should address physiognomy as a part of the Korean medicine so that the Korean medicine can contribute to mankind for a better and healthy human life.

Treatment and Prevention of Abnormality with Lateral Flexion and Rotation in Cervical Spine

  • Lee, Hyun-Chang;Shin, Seong-Yoon;Park, Ki-Hong
    • Journal of the Korea Society of Computer and Information
    • /
    • v.24 no.10
    • /
    • pp.189-194
    • /
    • 2019
  • In the healthcare system, the human neck(cervical spine) is one of the most important organs. The area that supports the human head is the cervical spine. Nowadays, we are often overworked our neck to calls with the smart phone or see the monitors. In this paper, we investigate the abnormalities of lateral flexion and rotation of the cervical spine. The normal angle of lateral flexion is $20^{\circ}$ to $45^{\circ}$ and the normal angle of rotation is $50^{\circ}$ to $90^{\circ}$. If this angle is below normal and we feel pain, there is something wrong with the cervical spine. In addition, learn how to measure the lateral flexion and rotation of the neck or cervical spine, and also to find out how to treat an abnormality. We also look at how to prevent more than lateral flexion and rotation of the cervical spine. The experiment was carried out with 100 people in their 50s, men and women, to find out whether the neck is abnormal.