• Title/Summary/Keyword: Digital Therapy

Search Result 632, Processing Time 0.028 seconds

Heterogeneous Sensor Coordinate System Calibration Technique for AR Whole Body Interaction (AR 전신 상호작용을 위한 이종 센서 간 좌표계 보정 기법)

  • Hangkee Kim;Daehwan Kim;Dongchun Lee;Kisuk Lee;Nakhoon Baek
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.12 no.7
    • /
    • pp.315-324
    • /
    • 2023
  • A simple and accurate whole body rehabilitation interaction technology using immersive digital content is needed for elderly patients with steadily increasing age-related diseases. In this study, we introduce whole-body interaction technology using HoloLens and Kinect for this purpose. To achieve this, we propose three coordinate transformation methods: mesh feature point-based transformation, AR marker-based transformation, and body recognition-based transformation. The mesh feature point-based transformation aligns the coordinate system by designating three feature points on the spatial mesh and using a transform matrix. This method requires manual work and has lower usability, but has relatively high accuracy of 8.5mm. The AR marker-based method uses AR and QR markers recognized by HoloLens and Kinect simultaneously to achieve a compliant accuracy of 11.2mm. The body recognition-based transformation aligns the coordinate system by using the position of the head or HMD recognized by both devices and the position of both hands or controllers. This method has lower accuracy, but does not require additional tools or manual work, making it more user-friendly. Additionally, we reduced the error by more than 10% using RANSAC as a post-processing technique. These three methods can be selectively applied depending on the usability and accuracy required for the content. In this study, we validated this technology by applying it to the "Thunder Punch" and rehabilitation therapy content.

Effects of an exercise program to strengthen the musculoskeletal system on the body of elderly women (근골격계 강화를 위한 운동 프로그램이 노인 여성의 신체에 미치는 영향)

  • Jung-Ho Lee
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.6
    • /
    • pp.41-47
    • /
    • 2023
  • This study was conducted to determine the effect of an exercise program applied to prevent musculoskeletal changes that occur due to aging on pain, muscle strength, balance ability, and falling efficacy in elderly women. An exercise program including quadriceps setting exercise, bridge exercise, resistance band exercise, and foam roller exercise was applied to elderly women aged 65 years or older once a week for 8 weeks. A visual analog scale was used to evaluate pain, muscle strength was evaluated using a digital muscle strength meter, balance ability was measured using the Berg balance scale, and fear of falling was evaluated using the fall efficacy scale. As a result of the study, compared to before the experiment, pain in the lower back and knee area was significantly reduced, the strength of the quadriceps femoris and gluteus maximus was significantly increased, and balance ability and falling efficacy were significantly improved. In conclusion, application of a program that includes various exercise methods has a positive effect on the physical activity of elderly women by strengthening the musculoskeletal system. Additionally, in order to prevent physical changes due to aging, an exercise program that includes various exercise methods that can strengthen the musculoskeletal system should be applied.

Evaluation of the Positional Uncertainty of a Liver Tumor using 4-Dimensional Computed Tomography and Gated Orthogonal Kilovolt Setup Images (사차원전산화단층촬영과 호흡연동 직각 Kilovolt 준비 영상을 이용한 간 종양의 움직임 분석)

  • Ju, Sang-Gyu;Hong, Chae-Seon;Park, Hee-Chul;Ahn, Jong-Ho;Shin, Eun-Hyuk;Shin, Jung-Suk;Kim, Jin-Sung;Han, Young-Yih;Lim, Do-Hoon;Choi, Doo-Ho
    • Radiation Oncology Journal
    • /
    • v.28 no.3
    • /
    • pp.155-165
    • /
    • 2010
  • Purpose: In order to evaluate the positional uncertainty of internal organs during radiation therapy for treatment of liver cancer, we measured differences in inter- and intra-fractional variation of the tumor position and tidal amplitude using 4-dimentional computed radiograph (DCT) images and gated orthogonal setup kilovolt (KV) images taken on every treatment using the on board imaging (OBI) and real time position management (RPM) system. Materials and Methods: Twenty consecutive patients who underwent 3-dimensional (3D) conformal radiation therapy for treatment of liver cancer participated in this study. All patients received a 4DCT simulation with an RT16 scanner and an RPM system. Lipiodol, which was updated near the target volume after transarterial chemoembolization or diaphragm was chosen as a surrogate for the evaluation of the position difference of internal organs. Two reference orthogonal (anterior and lateral) digital reconstructed radiograph (DRR) images were generated using CT image sets of 0% and 50% into the respiratory phases. The maximum tidal amplitude of the surrogate was measured from 3D conformal treatment planning. After setting the patient up with laser markings on the skin, orthogonal gated setup images at 50% into the respiratory phase were acquired at each treatment session with OBI and registered on reference DRR images by setting each beam center. Online inter-fractional variation was determined with the surrogate. After adjusting the patient setup error, orthogonal setup images at 0% and 50% into the respiratory phases were obtained and tidal amplitude of the surrogate was measured. Measured tidal amplitude was compared with data from 4DCT. For evaluation of intra-fractional variation, an orthogonal gated setup image at 50% into the respiratory phase was promptly acquired after treatment and compared with the same image taken just before treatment. In addition, a statistical analysis for the quantitative evaluation was performed. Results: Medians of inter-fractional variation for twenty patients were 0.00 cm (range, -0.50 to 0.90 cm), 0.00 cm (range, -2.40 to 1.60 cm), and 0.00 cm (range, -1.10 to 0.50 cm) in the X (transaxial), Y (superior-inferior), and Z (anterior-posterior) directions, respectively. Significant inter-fractional variations over 0.5 cm were observed in four patients. Min addition, the median tidal amplitude differences between 4DCTs and the gated orthogonal setup images were -0.05 cm (range, -0.83 to 0.60 cm), -0.15 cm (range, -2.58 to 1.18 cm), and -0.02 cm (range, -1.37 to 0.59 cm) in the X, Y, and Z directions, respectively. Large differences of over 1 cm were detected in 3 patients in the Y direction, while differences of more than 0.5 but less than 1 cm were observed in 5 patients in Y and Z directions. Median intra-fractional variation was 0.00 cm (range, -0.30 to 0.40 cm), -0.03 cm (range, -1.14 to 0.50 cm), 0.05 cm (range, -0.30 to 0.50 cm) in the X, Y, and Z directions, respectively. Significant intra-fractional variation of over 1 cm was observed in 2 patients in Y direction. Conclusion: Gated setup images provided a clear image quality for the detection of organ motion without a motion artifact. Significant intra- and inter-fractional variation and tidal amplitude differences between 4DCT and gated setup images were detected in some patients during the radiation treatment period, and therefore, should be considered when setting up the target margin. Monitoring of positional uncertainty and its adaptive feedback system can enhance the accuracy of treatments.

PTV Margins for Prostate Treatments with an Endorectal Balloon (전립선 암의 방사선치료 시 직장 내 풍선삽입에 따른 계획표적부피마진)

  • Kim, Hee-Jung;Chung, Jin-Beom;Ha, Sung-Whan;Kim, Jae-Sun;Ye, Sung-Joon
    • Radiation Oncology Journal
    • /
    • v.28 no.3
    • /
    • pp.166-176
    • /
    • 2010
  • Purpose: To determine the appropriate prostate planning target volume (PTV) margins for 3-dimensitional (3D) conformal radiotherapy (CRT) and intensity-modulated radiation therapy (IMRT) patients treated with an endorectal balloon (ERB) under our institutional treatment condition. Materials and Methods: Patients were treated in the supine position. An ERB was inserted into the rectum with 70 cc air prior to planning a CT scan and then each treatment fraction. Electronic portal images (EPIs) and digital reconstructed radiographs (DRR) of planning CT images were used to evaluate inter-fractional patient's setup and ERB errors. To register both image sets, we developed an in-house program written in visual $C^{++}$. A new method to determine prostate PTV margins with an ERB was developed by using the common method. Results: The mean value of patient setup errors was within 1 mm in all directions. The ERB inter-fractional errors in the superior-inferior (SI) and anterior-posterior (AP) directions were larger than in the left-right (LR) direction. The calculated 1D symmetric PTV margins were 3.0 mm, 8.2 mm, and 8.5 mm for 3D CRT and 4.1 mm, 7.9 mm, and 10.3 mm for IMRT in LR, SI, and AP, respectively according to the new method including ERB random errors. Conclusion: The ERB random error contributes to the deformation of the prostate, which affects the original treatment planning. Thus, a new PTV margin method includes dose blurring effects of ERB. The correction of ERB systematic error is a prerequisite since the new method only accounts for ERB random error.

Evaluation of Image Quality for Various Electronic Portal Imaging Devices in Radiation Therapy (방사선치료의 다양한 EPID 영상 질평가)

  • Son, Soon-Yong;Choi, Kwan-Woo;Kim, Jung-Min;Jeong, Hoi-Woun;Kwon, Kyung-Tae;Cho, Jeong-Hee;Lee, Jea-Hee;Jung, Jae-Yong;Kim, Ki-Won;Lee, Young-Ah;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.451-461
    • /
    • 2015
  • In megavoltage (MV) radiotherapy, delivering the dose to the target volume is important while protecting the surrounding normal tissue. The purpose of this study was to evaluate the modulation transfer function (MTF), the noise power spectrum (NPS), and the detective quantum efficiency (DQE) using an edge block in megavoltage X-ray imaging (MVI). We used an edge block, which consists of tungsten with dimensions of 19 (thickness) ${\times}$ 10 (length) ${\times}$ 1 (width) $cm^3$ and measured the pre-sampling MTF at 6 MV energy. Various radiation therapy (RT) devices such as TrueBeam$^{TM}$ (Varian), BEAMVIEW$^{PLUS}$ (Siemens), iViewGT (Elekta) and Clinac$^{(R)}$iX (Varian) were used. As for MTF results, TrueBeam$^{TM}$(Varian) flattening filter free(FFF) showed the highest values of $0.46mm^{-1}$ and $1.40mm^{-1}$ for MTF 0.5 and 0.1. In NPS, iViewGT (Elekta) showed the lowest noise distribution. In DQE, iViewGT (Elekta) showed the best efficiency at a peak DQE and $1mm^{-1}DQE$ of 0.0026 and 0.00014, respectively. This study could be used not only for traditional QA imaging but also for quantitative MTF, NPS, and DQE measurement for development of an electronic portal imaging device (EPID).

A Systematic Study of the Intervention Effect of Social Stories in Children with Sleep Disorders (수면장애 아동을 위한 사회적 이야기 중재 효과: 체계적 고찰)

  • Kim, Ji-Ho;Yoo, Eun-Young
    • The Journal of Korean Academy of Sensory Integration
    • /
    • v.21 no.2
    • /
    • pp.69-83
    • /
    • 2023
  • Objective : This study sought to systematically examine the intervention effect of social stories when applied in relation to children with sleep disorders. Methods : Studies available in the SCOPUS, ScienceDirect, PsycArticles, and PubMed databases that were published from 2001 to 2022 were searched. The keywords used for the search were as follows: ("social story" OR "social stories") AND ("sleep" OR "sleep disorders" OR "sleep wake disorder bedtimes" OR "sleep initiation and maintenance disorders" OR "sleep wake disorder" OR "sleep arousal disorders"). Based on the selection criteria, six experimental studies were selected and analyzed. Results : The selected studies were two randomized controlled trials, three individual trials, and one case study. The subjects were mostly children diagnosed with autism spectrum disorder who were school-aged or adolescent. The intervention types were often complex interventions, including social stories and other interventions, while the durations of the interventions varied from one day to more than 40 days. The interventions had a positive effect on the subjects' sleep quality, with night wakings, sleep onset delay, and sleep anxiety all being improved. As standardized assessment tools to evaluate the effectiveness of social stories, the Child Sleep Habits Questionnaire and the Child Behavior Checklist were used in two papers each, and were the most commonly used. As non-standardized assessment tools, each of the four papers used turbulence and sleep diaries as assessment tools. Conclusion : The effect of social story mediation can be divided into sleep quality and sleep-related behavior. In terms of sleep quality, studies showing improvements in night wakings, sleep onset delay, and sleep anxiety accounted for a large proportion of the sample. The detailed effect area of sleep quality showed a significant improvement after the interventions in most studies, and in all six studies analyzed in the present study, the continuation of the effect after the intervention was confirmed via follow-up tests. Thus, the findings of this study are expected to be helpful when applying social stories in children with sleep disorders in clinical practice due to presenting the intervention effects, outcome evaluation tools, and intervention periods in children with sleep disorders in prior investigations involving social stories.

A study anxiety of mothers who have hospitalized ill children Focusing on the comparison of korean mothers with multicultural family mothers (입원 환아 어머니의 불안에 관한 연구: 한국인 어머니와 다문화가정 어머니 비교를 중심으로)

  • Oh, Jae-Woo;Moon, Young-Sook
    • Journal of Digital Convergence
    • /
    • v.10 no.6
    • /
    • pp.311-319
    • /
    • 2012
  • This study, by grasping the degree of anxiety of Korean mothers and multicultural family mothers because of their hospitalized children, was aimed to arrange the basic data for developing the program to help the mothers of Korea and multicultural family reduce the anxiety happening due to the hospitalization of their children and adapt to their environment. Methods: The subjects of the study were a total of 200 people composed of 100 multicultural family mothers, and 100 Korean mothers respectively whose children were hospitalized in the pediatric department of K university hospital located in Daejeon City. And the period of data collection was from Aug 1, 2010 to Aug 31, 2010.As a study tool, the measuring tool of Kim Jeong Taek(1978), which STAI of Sielberger(1972) was adapted to Koreans, was used.The collected data was analyzed using SPSS WIN 12.0. Results. A result of the state anxiety of the Korean mothers with that of the multicultural family mothers of the inpatient children, Korean mothers 2.11, multicultural family mothers 2.17, result of temperament anxiety showed Korean mothers 2.09, multicultural family mothers 1.94. As a result of comparing the anxiety of the Korean mothers with that of the multicultural family mothers of the inpatient children, there was no difference between groups in both temperament anxiety and state anxiety. In a situation of anxiety, when there was no explanation of the treatment or therapy, both Korean mothers and multicultural family mothers showed the severe anxiety. In the degree of anxiety according to the general characteristics of the mothers of the inpatient children, there was not a statistically significant result in anxiety according to general characteristics of the inpatient children of korean family mothers, there was a significant difference in state anxiety according to the state of average monthly income in Korean mothers(P<.05), however, there was a significant one in temperament anxiety in the course of perceiving a test method in multicultural family mothers(P<.05). In the degree of anxiety according to the general characteristics of the mothers of the inpatient children, there was a significant difference in state anxiety according to the state of average monthly income in Korean mothers(P<.05), however, there was a significant one in temperament anxiety in the course of perceiving a test method in multicultural family mothers(P<.05). Conclusion: Through the results of the study above, no matter what socio-demographic characteristics of the mothers of the inpatient children are, regardless of the general characteristics of the inpatient children, it was found out that most of mothers felt anxiety.

Analysis of alveolar molding effects in infants with bilateral cleft lip and palate when treated with pre-surgical naso-alveolar molding appliance (양측성 순구개열 신생아 환자의 수술전 비치조 정형장치 치료에 의한 치조골 조형(molding) 효과의 분석)

  • Nahm, Dong-Seok;Yang, Won-Sik;Baek, Seung-Hak;Kim, Sukwha
    • The korean journal of orthodontics
    • /
    • v.29 no.6 s.77
    • /
    • pp.649-661
    • /
    • 1999
  • The goals of this study were 1) to present pre-surgical naso-alveolar molding (PNAM) appliance for bilateral cleft lip and palate treatment and 2) to evaluate the effects of the PNAM appliance on the alveolar molding of the premaxilla and the lateral segments. Subjects consisted of 8 bilateral cleft lip and palate infants (7 males and 1 female, mean age at first visit = 61.6 days after birth) who were treated with PNAM appliances in Department of Orthodontics, Seoul National University Dental Hospital. Average alveolar cleft gap between the premaxilla and the lateral segment was $8.09{\pm}5.03mm$ and average duration of alveolar molding treatment was $8.8{\pm}3.1$ weeks. These patients' models were obtained at initial visit (T0) and after alveolar molding (T1). 20 linear and 14 angular variables were measured by using photometry and digital caliper, All statistical analyses were performed by Microsoft Excel 97 program. Paired t-test was used to discriminate the effect of alveolar molding by PNAM appliance. 1. Closure of the alveolar cleft gap in bilateral cleft cases by molding therapy was completed successfully, 2. Alveolar molding inhibited outward growth of lateral segments and produced inward bending of lateral segments. 3. By bending the anterior part of the vomer, the premaxilla could be rotated and moved. posteriorly via alveolar molding. Conclusion This appliance can be applied to bilateral cleft lip and palate infants with satisfactory results before cheiloplasty.

  • PDF

The Accuracy of the Digital Imaging System and the Frequency Dependent Type Apex Locator in Root Canal Length Measurement (근관장 측정에 있어서 디지털 영상 처리기와 주파수 의존형 측정기의 정확도)

  • Lee Byaung-Rib;Park Chang-Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.28 no.2
    • /
    • pp.435-459
    • /
    • 1998
  • In order to achieve a successful endodontic treatment, root canals must be obturated three-dimensionally without causing any damage to apical tissues. Accurate length determination of the root canal is critical in this case. For this reason, I've used the conventional periapical radiography, Digora/sup (R)/(digital imaging system) and Root ZX/sup (R)/(the frequency dependent type apex locator) to measure the length of the canal and compare it with the true length obtained by cutting the tooth in half and measuring the length between the occlusal surface and the apical foramen. From the information obtained by these measurements, I was able to evaluate the accuracy and clinical usefulness of each systems. whether the thickness of files used in endodontic therapy has any effect on the measuring systems was also evaluated in an effort to simplify the treatment planning phase of endodontic treatment. 29 canals of 29 sound premolars were measured with #15, #20, #25 files by 3 different dentists each using the periapical radiography. Digora/sup (R)/ and Root ZX/sup (R)/. The measurements were then compared with the true length. The results were as follows: 1. In comparing mean discrepancies between measurements obtained by using periapical radiography(mean error: -0.449±0.444 mm), Digora/sup (R)/(mean error: -0.417±0.415 mm) and Root ZX/sup (R)/(mean error: 0.123±0.458 mm) with true length. periapical radiography and Digora/sup (R)/ system had statistically significant differences(p<0.05) in most cases while Root ZX/sup (R)/ showed none(p>0.05). 2. By subtracting values obtained by using periapical radiography, Digora/sup (R)/ and Root ZX/sup (R)/ from the true length and making a distribution table of their absolute values. the following analysis was possible. In the case of periapical film. 140 out of 261<53.6%) were clinically acceptable satisfying the margin of error of less than 0.5 mm. 151 out of 261 (53,6%) were acceptable in the Digora/sup (R)/ system while Root ZX/sup (R)/ had 197 out of 261(75.5%) within the limits of 0.5mm margin of error. 3. In determining whether the thickness of files has any effect on measuring methoths, no statistically significant differences were found(p>0.05). 4. In comparing data obtained from these methods in order to evaluate the difference among measuring methods, there was no statistically significant difference between periapical radiography and Digora/sup (R)/ system(p>0.05), but there was statistically significant difference between Root ZX/sup (R)/ and periapical radiography(p<0.05). Also there was statistically significant difference between Root ZX/sup (R)/ and Digora/sup (R)/ system(p<0.05). In conclusion, Root ZX/sup (R)/ was more accurate when compared with the Digora/sup (R)/ system and periapical radiography and seems to be more effective clinically in determining root canal length. But Root ZX/sup (R)/ has its limits in determining root morphology and number of roots and its accuracy becomes questionable when apical foramen is open due to unknown reasons. Therefore the combined use of Root ZX/sup (R)/ and the periapical radiography are mandatory. Digora/sup (R)/ system seems to be more effective when periapical radiographs are needed in a short period of time because of its short processing time and less exposure.

  • PDF

A study on developing a new self-esteem measurement test adopting DAP and drafting the direction of digitalizing measurement program of DAP (청소년 자존감 DAP 인물화 검사 개발 및 디지털화 측정 시스템 방향성 연구)

  • Woo, Sungju;Park, Chongwook
    • Journal of the HCI Society of Korea
    • /
    • v.8 no.1
    • /
    • pp.1-9
    • /
    • 2013
  • This is to develop a new way of testing self-esteem by adopting DAP(Draw a Person) test and to make a platform to digitalize it for young people in the adolescent stage. This approach is to get high effectiveness of the self-esteem measurement using DAP test, including some personal inner situations which can be easily missed in the large statistical analysis. The other objective of this study is digitalize to recover limits of DAP test in the subjective rating standard. It is based on the distribution of the figure drawing expressed numerically by the anxiety index of Handler. For these two examinations, we made experiment through 4 stages with second grade middle school 73 students from July 30th to October 31th in 2009 during 4 months. Firstly, we executed 'Self Values Test' for all 73 people, and divided them into two groups; one is high self-esteem group of 36 people, the other is low self-esteem group of 37 people. Secondly, we regrouped them following D (Depression), Pd (Psychopathic Deviate), Sc (Schizophrenia) scales of MMPI; one is high self-esteem group of 7 people, the other is low self-esteem group of 13 people. Thirdly, we conducted DAP test separately for these 20 people. We intended to verify necessity and appropriateness of direction of 'Digitalizing Measurement System' by comparing and analyzing relation between DAP and Self-esteem following evaluation criteria which has similarity in 3 tests, after executing DAP to reflect peculiarity of adolescents sufficiently. We compared and analyzed result abstracted by sampling DAP test of two groups; One is high self-esteem group of 2 people, the other is low self-esteem group of 2 people; to confirm whether we can improve limitation that original psychological testing has by comparing mutual reliance of measurement test. Finally, with DAP test gained from correlations between self-esteem and melancholia following as above-mentioned steps, we discovered possibility of realization to get a concrete and individual criteria of evaluation based on Expert System as a way of enhancing accessibility in quantitative manner. 'Digitalizing Measurement Program' of DAP test suggested in this study promote results' reliability based on existing tests and measurement.

  • PDF