• 제목/요약/키워드: Digital Radiography

검색결과 487건 처리시간 0.029초

A fully deep learning model for the automatic identification of cephalometric landmarks

  • Kim, Young Hyun;Lee, Chena;Ha, Eun-Gyu;Choi, Yoon Jeong;Han, Sang-Sun
    • Imaging Science in Dentistry
    • /
    • 제51권3호
    • /
    • pp.299-306
    • /
    • 2021
  • Purpose: This study aimed to propose a fully automatic landmark identification model based on a deep learning algorithm using real clinical data and to verify its accuracy considering inter-examiner variability. Materials and Methods: In total, 950 lateral cephalometric images from Yonsei Dental Hospital were used. Two calibrated examiners manually identified the 13 most important landmarks to set as references. The proposed deep learning model has a 2-step structure-a region of interest machine and a detection machine-each consisting of 8 convolution layers, 5 pooling layers, and 2 fully connected layers. The distance errors of detection between 2 examiners were used as a clinically acceptable range for performance evaluation. Results: The 13 landmarks were automatically detected using the proposed model. Inter-examiner agreement for all landmarks indicated excellent reliability based on the 95% confidence interval. The average clinically acceptable range for all 13 landmarks was 1.24 mm. The mean radial error between the reference values assigned by 1 expert and the proposed model was 1.84 mm, exhibiting a successful detection rate of 36.1%. The A-point, the incisal tip of the maxillary and mandibular incisors, and ANS showed lower mean radial error than the calibrated expert variability. Conclusion: This experiment demonstrated that the proposed deep learning model can perform fully automatic identification of cephalometric landmarks and achieve better results than examiners for some landmarks. It is meaningful to consider between-examiner variability for clinical applicability when evaluating the performance of deep learning methods in cephalometric landmark identification.

Detection of different foreign bodies in the maxillofacial region with spiral computed tomography and cone-beam computed tomography: An in vitro study

  • Abolvardi, Masoud;Akhlaghian, Marzieh;Shishvan, Hadi Hamidi;Dastan, Farivar
    • Imaging Science in Dentistry
    • /
    • 제50권4호
    • /
    • pp.291-298
    • /
    • 2020
  • Purpose: The detection and exact localization of penetrating foreign bodies are crucial for the appropriate management of patients with dentoalveolar trauma. This study compared the efficacy of cone-beam computed tomography (CBCT) and spiral computed tomography (CT) scans for the detection of different foreign bodies composed of 5 frequently encountered materials in 2 sizes. The effect of the location of the foreign bodies on their visibility was also analyzed. Materials and Methods: In this in vitro study, metal, tooth, stone, glass, and plastic particles measuring 1×1×1 mm and 2×2×2 mm were prepared. They were implanted in a sheep's head in the tongue muscle, nasal cavity, and at the interface of the mandibular cortex and soft tissue. CBCT and spiral CT scans were taken and the visibility of foreign bodies was scored by 4 skilled maxillofacial radiologists who were blinded to the location and number of foreign bodies. Results: CT and CBCT were equally accurate in visualizing metal, stone, and tooth particles of both sizes. However, CBCT was better for detecting glass particles in the periosteum. Although both imaging modalities visualized plastic particles poorly, CT was slightly better for detecting plastic particles, especially the smaller ones. Conclusion: Considering the lower patient radiation dose and cost, CBCT can be used with almost equal accuracy as CT for detecting foreign bodies of different compositions and sizes in multiple maxillofacial regions. However, CT performed better for detecting plastic particles.

Clinical comparison of intraoral CMOS and PSP detectors in terms of time efficiency, patient comfort, and subjective image quality

  • Kamburoglu, Kivanc;Samunahmetoglu, Ercin;Eratam, Nejlan;Sonmez, Gul;Karahan, Sevilay
    • Imaging Science in Dentistry
    • /
    • 제52권1호
    • /
    • pp.93-101
    • /
    • 2022
  • Purpose: This study compared the effectiveness of complementary metal-oxide semiconductors (CMOS) and photostimulable phosphor (PSP) plates as intraoral imaging systems in terms of time efficacy, patient comfort, and subjective image quality assessment in real clinical settings. Materials and Methods: Fifty-eight patients (25 women and 33 men) were included. Patients were referred for a full-mouth radiological examination including 1 bitewing radiograph (left and right) and 8 periapical radiographs for each side (left maxilla/mandible and right maxilla/mandible). For each patient, 1 side of the dental arch was radiographed using a CMOS detector, whereas the other side was radiographed using a PSP detector, ensuring an equal number of left and right arches imaged by each detector. Clinical application time, comfort/pain, and subjective image quality were assessed for each detector. Continuous variables were summarized as mean±standard deviation. Differences between detectors were evaluated using repeated-measures analysis of variance. P<0.05 was accepted as significant. Results: The mean total time required for all imaging procedures with the CMOS detector was significantly lower than the mean total time required for imaging procedures with PSP (P<0.05). The overall mean patient comfort scores for the CMOS and PSP detectors were 4.57 and 4.48, respectively, without a statistically significant difference (P>0.05). The performance of both observers in subjectively assessing structures was significantly higher when using CMOS images than when using PSP images for all regions (P<0.05). Conclusion: The CMOS detector was found to be superior to the PSP detector in terms of clinical time efficacy and subjective image quality.

보조기구를 이용한 DR System 활용 방법에 대한 연구 (A Study on how to Utilize the DR System using Assistive Devices)

  • 서선열;김정호;이진옥
    • 한국방사선학회논문지
    • /
    • 제17권1호
    • /
    • pp.115-122
    • /
    • 2023
  • 엉덩관절 고정기구는 골밀도 검사 및 미세골절, 관절염의 진단 시 내회전을 위한 중요 고정기구입니다. 이러한 고정기구는 벨크로를 사용하여 재현성 유지에 한계가 있습니다. 이에 본 연구에서는 개선된 엉덩관절 고정기구를 개발하여 유용성을 평가하였습니다. 방사선과 재학생 30 명을 대상으로 기존과 개선된 고정기구를 적용하여 자세잡이 소요시간과 의료영상을 통한 재현성을 평가하였습니다. 또한, 시간경과에 따른 변화도 평가하였습니다. 그 결과 기존 고정기구에 비해 개선된 고정기구는 자세잡이 시간은 약 32%의 감소를 보였으며, 재현성은 약 6.2 배 향상되었습니다. 시간경과에 따른 변화량은 자세잡이 시간은 기존 고정기구는 증가된 반면 개선된 고정기구는 감소되었으며, 재현성은 개선된 고정기구보다 기존 고정기구가 더 저하되었습니다. 이를 통해 개선된 고정기구의 사용을 통해 영상의 질 향상과 방사선사의 업무부담 감소가 나타났다고 할 수 있습니다.

Comparison of Multi-Label U-Net and Mask R-CNN for panoramic radiograph segmentation to detect periodontitis

  • Rini, Widyaningrum;Ika, Candradewi;Nur Rahman Ahmad Seno, Aji;Rona, Aulianisa
    • Imaging Science in Dentistry
    • /
    • 제52권4호
    • /
    • pp.383-391
    • /
    • 2022
  • Purpose: Periodontitis, the most prevalent chronic inflammatory condition affecting teeth-supporting tissues, is diagnosed and classified through clinical and radiographic examinations. The staging of periodontitis using panoramic radiographs provides information for designing computer-assisted diagnostic systems. Performing image segmentation in periodontitis is required for image processing in diagnostic applications. This study evaluated image segmentation for periodontitis staging based on deep learning approaches. Materials and Methods: Multi-Label U-Net and Mask R-CNN models were compared for image segmentation to detect periodontitis using 100 digital panoramic radiographs. Normal conditions and 4 stages of periodontitis were annotated on these panoramic radiographs. A total of 1100 original and augmented images were then randomly divided into a training (75%) dataset to produce segmentation models and a testing (25%) dataset to determine the evaluation metrics of the segmentation models. Results: The performance of the segmentation models against the radiographic diagnosis of periodontitis conducted by a dentist was described by evaluation metrics(i.e., dice coefficient and intersection-over-union [IoU] score). MultiLabel U-Net achieved a dice coefficient of 0.96 and an IoU score of 0.97. Meanwhile, Mask R-CNN attained a dice coefficient of 0.87 and an IoU score of 0.74. U-Net showed the characteristic of semantic segmentation, and Mask R-CNN performed instance segmentation with accuracy, precision, recall, and F1-score values of 95%, 85.6%, 88.2%, and 86.6%, respectively. Conclusion: Multi-Label U-Net produced superior image segmentation to that of Mask R-CNN. The authors recommend integrating it with other techniques to develop hybrid models for automatic periodontitis detection.

Association between Taql polymorphism of vitamin D receptor gene and vertical growth of the mandible: A cross-sectional study

  • Baris Can Telatar;Gul Yildiz Telatar;Faruk Saydam
    • 대한치과교정학회지
    • /
    • 제53권5호
    • /
    • pp.336-342
    • /
    • 2023
  • Objective: To determine whether the gonial angle on digital panoramic radiographs is associated with vitamin D receptor (VDR) Taql polymorphism. Methods: Genomic DNA samples were collected from the buccal mucosa of patients aged 26-43 years. TaqMan assay for single nucleotide polymorphism genotyping was used to detect the genotype of Taql polymorphism. The gonial angle was measured bilaterally on panoramic radiography. The normal gonial angle was fixed as 121.8°, and it represented the cutoff value for the high gonial angle (HGA) and low gonial angle (LGA) groups. Various genetic models were analyzed, namely dominant (homozygous [AA] vs. heterozygous [AG] + polymorphic [GG]), recessive (AA + AG vs. GG), and additive (AA + GG vs. AG), using the chi-squared test. Results: The reliability of the gonial angle measurement was analyzed using a random sample (26%) of the tests, with the intra-examiner correlation showing an intra-class correlation coefficient of 0.99. The frequencies of the AA, AG, and GG genotypes of rs731236 polymorphism were 40.5%, 41.9%, and 17.6% in the HGA group and 21.8%, 51.0%, and 27.2% in the LGA group, respectively (P = 0.042). A statistically significant difference was observed in the allele frequencies between the two groups (P = 0.011). Moreover, a significant correlation was observed in the dominant genetic model. Conclusions: Taql polymorphism in the VDR gene plays a critical role in the vertical growth of the mandible and decreased gonial angle.

디지털 방사선에서 격자 비에 따른 영상변화에 관한 연구 (A Study on Image Change according to Grid Ratio in Digital Radiography )

  • 정성훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권2호
    • /
    • pp.89-97
    • /
    • 2023
  • With the introduction of the D.R system, the grid with high removal rate of scattered radiation is selected and used without considering the grid performance evaluation. Despite the high removal rate of scattered radiation belonging to high grid ratio, it is also possible to see the cut-off phenomenon in which the primary ray involved in the formation of image could be removed as well. Thus, the purpose of this study is to provide the basic data for researches on the usefulness of using the grid by presenting the appropriate grid ratio in the D.R system through the measurement of image in grid such as non-grid, 6:1, 8:1, 10:1, 12:1. The equipments used for this study were radiation generator with grid in 12:1, 10:1, 8:1, 6:1, indirect-type detector, and acryl phantom. As the study for image evaluation, this study measured the SNR, PSNR, MSE, and Entropy. In the results of this study, the PSNR was the highest in 6:1 and the lowest in 8:1. The SNR was high in 6:1 and 8:1, and the lowest in 12:1. In case of Entropy, it was high in 8:1 and 10:1, and the lowest in 12:1. Therefore, when the grid is used, it would be more proper to choose the grid in 8:1 or 10:1 with less loss in information content of primary ray rather than the high grid ratio showing the increased patient exposure dose.

교육용 의료방사선 시뮬레이터 시스템 개발 및 연구 모델 제안 (Development of a Medical Radiation Simulator System for Education and Proposal of a Research Model)

  • 한창화;전영황;한재복;공창기;송종남
    • 한국방사선학회논문지
    • /
    • 제17권3호
    • /
    • pp.459-464
    • /
    • 2023
  • 첨단 기술의 발전으로 디지털 방사선영상 장비들이 많이 개발되어 정확한 진단과 치료에 많은 도움을 받고 있으며, 이를 안전하고 효과적으로 사용하기 위하여 전문적인 지식을 습득한 인력양성이 매우 중요하다. 진단용 X선 장비를 활용한 촬영 실습 교육에 있어서 학생들은 방사선 피폭의 위험성에 노출되어 있고, 일부 교육기관에서는 원자력안전법에 따른 관리의 어려움으로 X선 장비를 사용하지 않는 경우도 발생하고 있다. 이에 대한 해결책으로, 본 연구에서는 비전 센서와 자체 개발한 소프트웨어를 활용하여 방사선이 발생하지 않는 교육용 의료방사선 시뮬레이터를 개발하였고, 이를 통해 교육기관은 법에 따른 행정 이행 사항의 부담을 줄일 수 있고, 학생들은 방사선 피폭이 없는 건강한 실습환경에서 높은 수준의 교육 효과를 얻을 수 있게 하였다.

Enhanced visualization of the root canal morphology using a chitosan-based endo-radiopaque solution

  • Shashirekha Govind;Amit Jena;Satabdi Pattanaik;Mahaprasad Anarasi ;Satyajit Mohapatra;Vinay Shivagange
    • Restorative Dentistry and Endodontics
    • /
    • 제46권3호
    • /
    • pp.33.1-33.12
    • /
    • 2021
  • Objectives: This study aimed to investigate the efficacy of ionic and non-ionic-based contrast media (in vitro study) and the combinatorial effect of chitosan-based endo-radiopaque solution (CERS) (in vivo study) for visualization of the root canal anatomy. Materials and Methods: In vitro study (120 teeth): The root canal of maxillary premolars and molars (in vitro group 1 and 2 respectively, n = 60 each) were analyzed using 4 different contrast media (subgroups: Omnipaque 350, Iopamidol, Xenetix 350, and Urografin 76; n = 15 each) in combination with 5.25% sodium hypochlorite (NaOCl). Based on the results of the in vitro study, in vivo study (80 teeth) was done to compare Xenetix 350 + 5.25% NaOCl with CERS (in vivo group 1 and 2 respectively, n = 40 each) on maxillary and mandibular premolars and molars. Two endodontists used radiovisiography to assess the depth of ingress and identify the aberrant root anatomy after access cavity preparation, and after initial cleaning and shaping of canals. Kruskal-Wallis test was used for in vitro comparison (p < 0.05), and Wilcoxon signed-rank test and Mann-Whitney U test for in vivo analysis (p < 0.01). Results: In vitro study, Xenetix 350 + 5.25% NaOCl facilitated a significant higher visualization (p < 0.05). For in vivo study, CERS had a statistically significant depth of ingress (p < 0.01), and was efficient in identifying the aberrant root canal anatomy of premolars and molars. Conclusions: CERS facilitates better visualization of the root canal anatomy of human premolars and molars.

Surgical Correction of Bilateral Gastrocnemius Muscle Rupture and Its Prognosis in a Korean Native Calf

  • Gyuho Jeong;Younghye Ro;Kyunghyun Min;Woojae Choi;Ilsu Yoon;Hyoeun Noh;Danil Kim
    • 한국임상수의학회지
    • /
    • 제40권3호
    • /
    • pp.215-220
    • /
    • 2023
  • A 3-month-old Korean native cattle (Hanwoo) calf with difficulty taking normal posture and an inability to rise was referred for a definite diagnosis and active treatment, including surgery. The calf had a history of an accident in which both hind limbs were trapped in a barn structure. After admission, a "rabbit leg" posture was observed, a typical sign of gastrocnemius muscle rupture, and both digits were knuckled downward like they were trying to grip the ground. This was considered to be a result of the superficial digital flexor not rupturing but only the gastrocnemius muscle rupturing. Physical examination revealed laceration of the metatarsus and firmness behind both stifle joints which were presumed to be the sites of gastrocnemius muscle rupture. Skeletal abnormalities, including fractures, were ruled out by radiography. Based on these findings, the patient was diagnosed with bilateral gastrocnemius muscle rupture, and surgery was performed to reconnect the head of the ruptured muscle. Because the rupture occurred perpendicular to the muscle direction, the locking loop technique, a method of suturing severed tendons, was used to reduce the tension. After surgery, the cast was used to prevent further injuries and promote voluntary rehabilitation. Follow-up was completed, with the calf showing normal posture and gait 112 days after surgery. This is the first case report in the Republic of Korea describing the successful diagnosis and treatment of bilateral gastrocnemius muscle rupture in a calf.