• Title/Summary/Keyword: Digital Protective Relay

Search Result 73, Processing Time 0.021 seconds

A Novel Digital Over Current Relay with Variable Time-Current Characteristics for Protective Coordination

  • Park, M. S.;P. S. Cho;Lee, S. J.;S. H. Hyun;Kim, K. H.
    • KIEE International Transactions on Power Engineering
    • /
    • v.2A no.3
    • /
    • pp.83-88
    • /
    • 2002
  • An over current relay(OCR), one of the most frequently used protective devices, has time-current characteristics (TCC) to control its trip time according to the current level. It is because an appropriate operating time interval is necessary for coordination with other protective devices. A set of TCC curves of an OCR is, in general, given by the supplier from which a curve is selected by the operator. Therefore, in many cases, it is impossible to consider the operation condition of the given power system exactly. A novel concept of an OCR is suggested in this paper. The proposed OCR has an internal correction module so that it may produce the most adequate TCC curve according to the given protective information for coordination with other devices. With the generated TCC curve, a variety of operation and coordination conditions can be taken into consideration in an effective manner. The suggested OCR is applied to a simple test power system to show very promising results from a coordination point of view.

Using Protective Relaying for Power Quality Monitoring (보호계전기를 이용한 전기품질 감시 기법 연구)

  • Bea, Y.J.;Lim, S.I.;Choi, I.S.;Lee, S.J.;Kim, J.H.;Kim, B.J.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.62-64
    • /
    • 2002
  • Power quality monitoring system is devoted to more concern than before, because the innovation of industrial technology needs more accurate instruments and more advanced power quality. Therefore, this paper is proposed to use digital protective relays for power quality monitoring. In addition, taking power quality events, Electrical magnetic phenomenon of IEEE std 1159, proposing that adaptive power quality event list consider limitation memory capacity and signal processing ability of protective relay. The prototype S/W of power quality analysis is also developed. Especially this prototype S/W analysis scheme is verified through many kinds of power quality events (gathering protective relay data) in EMTP simulation.

  • PDF

Development of Education and Training System for the Auto-Reclosing of Power Transmission System Using a Real Time Digital Simulator (실시간 계통시뮬레이터를 이용한 송전계통 자동재폐로 교육 및 훈련 시스템 개발)

  • Park, Jong-Chan;Yun, Sang-Yun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.1
    • /
    • pp.1-9
    • /
    • 2010
  • This paper summarizes an education and training system for the auto-reclosing of power transmission system using a real time digital simulator. The system is developed to understand the principle of reclosing and the sequence of automatic reclosing schemes, and practice the effects of reclosing actions to power system in real-time simulator. This study is concentrated into the following two parts. One is the development of real time education and training system of automatic reclosing schemes. For this, we use the RTDS(real time digital simulator) and the actual digital protective relay. The mathematical relay model of RTDS and the actual distance relay which is equipped automatic reclosing function are also used. The other is the user friendly interface between trainee and trainer. The various interface displays are used for user handing and result display. The conditions of automatic reclosing which is a number of reclosing, reclosing dead time, reset time, and so on, can be changed by the user interface panel. A number of scenario cases are reserved for the education and training. Through the test, we verified that the proposed system can be effectively used to accomplish the education and training of automatic reclosing.

Autonomous Adaptive Digital Over Current Relay (계통변화를 고려한 자율 적응형 과전류 계전기)

  • J.S., Jun-Seok;Lee, S.J.;Choi, M.S.;Kang, S.H.;Kim, S.T.;Lim, S.I.;Oh, S.M.;Kim, J.K.;Park, S.J.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.6-8
    • /
    • 2002
  • In this paper present Autonomous Adaptive Digital Over Current Relay which acts autonomous setting using voltage and current measured by relay in the change of power systems. Automation of relay setting is required for distribution automation although manual relay setting is used at present. This paper presents Autonomous Relay Setting which knows change of the power system and acquires setting element using the Recursive Least Squares. Relay setting is very difficult work. But proposed relay is expected to decrease burden of relay setting using acquired information of power system change and autonomous setting. Also fast protective ability is expected according to change of power system.

  • PDF

Fault Simulation and Analysis of Generator (발전기의 사고 시뮬레이션과 분석)

  • Park, Chul-Won;Oh, Yong-Taek
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.62 no.3
    • /
    • pp.151-158
    • /
    • 2013
  • Large generator of power plant is very important. In order to protect large generator from faults, digital protective relay or IED is required. However, all protective relays for generators of the domestic power plant are operated by foreign products. And now, for technological independence from foreign and improvement of import substitution effect, IEDs using domestic technology are being developed. To evaluate performance of developing next-generation power devices, the study of the dynamic characteristics of the power plant, generator system modeling, fault simulation and analysis, should be considered. Specially, To obtain IEEE Standards COMTRADE format for relay operation test, generator system modeling and fault simulation using PSCAD/EMTDC tools must be preceded. Until now, a complete modeling of generator internal windings and fault simulation techniques dose not exist. In this paper, for evaluation performance of relay elements of developing IED, the generator system modeling and various faults simulation using PSCAD/EMTDC tools were performed. And then, the various transient phenomena through obtained relaying signal of developed modeling were analyzed.

Development of SFCL Model using RTDS (RTDS 초전도한류기 해석모델 개발)

  • Lee, Seung-Ryul;Kwon, Jung-Ji;Yoon, Jae-Young;Lee, Byong-Jun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.10 no.3
    • /
    • pp.9-13
    • /
    • 2008
  • It is very important to study the protective relaying system from the viewpoint of technical analysis to apply superconducting power devices to real power systems. In this paper, we developed Superconducting Fault Current Limiter (SFCL) analysis model using Real Time Digital Simulator(RTDS) for protective relay tests in power system with SFCLs. The RTDS model has the operation mechanism of a real SFCL system.

A Study on the Development and Application of Digital Protective Relay for DC Feeding System of Light Rail Transit System (경전철 직류급전계통을 위한 디지털 보호제어장치의 개발 및 적용에 관한 연구)

  • Baek, Byung-San;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.2
    • /
    • pp.77-86
    • /
    • 2005
  • The DC protection and control device for the feeding system of a Light Rail Transit(LRT) system is developed. For the development, the short circuit characteristics in the system are analyzed. As a result a protection algorithm for the DC fault selective relay (50F) is newly proposed, and principles of the DC fault selective relay, Line Test Device (LTD), DC Over Current Relay (DC OCR) are introduced From the development, the specifications and codes used to be unclear have become clarified and summarized. Moreover, the methods to examine the protective characteristics and Electromagnetic Compatibility (EMC) are established Finally, the performance and the effectiveness of the developed protective relay have been verified with the test based on IEC. For the reliability of the system, the relay has been installed and is being operated at the test track of the LRT system at Gyeong-San.

A Study of the Operating Characteristic for Voltage Restrained Overcurrent Relay using the ATPDraw5.7p4 Modeling Data (ATPDraw5.7p4 모델링 데이터를 이용한 전압억제 과전류계전기 동작특성에 관한 연구)

  • Park, Chul-Won;Ban, Yu-Hyeon
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.61 no.1
    • /
    • pp.23-28
    • /
    • 2012
  • The market of domestic Power Plant Generator Protection and Control System (GPCS) is narrow and required the high reliability, and technology. So, it is still operated as turn-key. In recent years, digital relays has evolved into IED can perform the control and monitoring functions without central monitoring based on IEC61850 international standards communications, and attention for advancement of smart grid and ECMS has been increased in South Korea. The increasing attention on multi-function IED, DGPS(digital generator protection system), for internal fault protection of large generator results in starting a national project in South Korea, the IED prototype development for next-generation power units. The voltage restrained overcurrent relay have been used as back-up overcurrent protection for generators. In this paper, voltage restrained overcurrent relay is one of the back-up protective factors in generator protection IED was presented. For evaluation performance of the voltage restrained overcurrent relay, the data of ATPDraw5.7p4 modeling was used.

A Study on Development of Digital Protective Relay Simulator using Digital Signal Processor (DSP를 이용한 디지털 보호 계전기의 시뮬레이터에 관한 연구)

  • Lee, J.J.;Jung, H.S.;Park, C.W.;Shin, M.C.;An, T.P.;Ko, I.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.237-239
    • /
    • 2001
  • This paper describes the digital relay simulator system using digital signal processor. The simulator system has two parts, one is software and the other is hardware part. The simulation software has variety calculation engines ; EMTP simulation data file conversion, user define simulation data generation, sequence data generation, data analysis engines. etc, these are designed upon GUI. And simulator software provides easy control interface for users, the simulator software performs on every MS Windows OS. The simulator hardware design uses 32bit floating point DSP(TMS320C32) architecture to achieve flexibility and high speed operation.

  • PDF

A study on the efficient operation program of digital protection relay in DC feeder system (DC 급전계통의 디지털 보호계전기의 합리적 운용방안 검토)

  • Lee, Kyung-Goo;Hyun, Yong-Sub;Hong, Sung-Lae;Baek, Jae-Woo;Min, Yong-Ho
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.946-958
    • /
    • 2009
  • Lately, Seoul metro is changing transformation facilities which have been operated in subway line 1 and 2 for a long duration of time. Although the exiting protection relays in DC feeder system have such several functions as 76I, 50, 85, and 64P, the new protective relay have a great variety of functions such as 76I, 76D, DDL-I, DDL-T(Imin), 85, and 64P, as well as record and save various events and accident wave in order to review and analyze the working causes of the protective system. However, because the new digital relays are not used properly for protective propose, there are the cases that the electric accident is deteriorated more. Therefore, in this paper, we will describe that making the use studying installation intention, direction, and setting up value of the protection relay in DC breaker operation not only prevents from making the electric accident worse but also shows the efficient operation method of direct current protection system.

  • PDF