• Title/Summary/Keyword: Digital PI control

Search Result 141, Processing Time 0.03 seconds

An Improved Stationary Frame-based Digital Current Control Scheme for a PM Synchronous Motor

  • Kim, Kyeong-Hwa;Young, Myung-Joong
    • Journal of Power Electronics
    • /
    • v.1 no.2
    • /
    • pp.88-98
    • /
    • 2001
  • An improved stationary frame-based digital current control technique for a permanent magnet(PM) synchronous motor is presented. Generally, the stationary frame current controller is known to provide the advantage of a simple implementation. However, there are some unavoidable limitations such as a steady-state error and a phase delay in the steady-state. On the other hand, in the synchronous frame current regulator the regulated currents are dc quantities and a zero steady-state error can be obtained through the integral control. However, the need to transform the signals between the stationary and synchronous frames makes the implementation of a synchronous frame regulator complex. Although the PI controller in the stationary frame gives a steady-state error and a phase delay, the control performance can be greatly improved by employing the exact decoupling control inputs for the back EMF., resulting in an ideal steady-state control characteristics irrespective of an operating condition as in the synchronous PI decoupling controller. However, its steady-state response may be degraded due to the inexact cancellation inputs under the parameter variations. To improve the control performance in the stationary frame, the disturbance is estimated using the time delay control. The proposed scheme is implemented on a PM synchronous motor using DSP TMS320C31 and the effectiveness is verified through the comparative simulations and experiments.

  • PDF

A Simulation of Temperature Control of Greenhouse with Hot-Water Heating System (온수난방시스템 온실의 온도제어 시뮬레이션)

  • 정태상;하종규;민영봉
    • Journal of Bio-Environment Control
    • /
    • v.8 no.3
    • /
    • pp.152-163
    • /
    • 1999
  • It is required to analyze the controlled response of air temperature in greenhouse according to control techniques for precise control. In this study, a mathematical model was established for air heating of greenhouse with hot-water heating system The parameters of the model were decided by regression analysis using reference data measured at the greenhouse being heated In the simulation for the digital control of air temperature in the greenhouse, the mathematical model to evaluate the control performances was used. Tested control methods were ON-OFF contpol, p control, rl control and PID control. The mathematical model represented by inside air temperature ( T$_{i}$), hot-water temperature (T$_{w}$) in heating pipe and outside air temperature (T$_{o}$) was expressed as a following discrete time equation ; T$_{i}$($textsc{k}$+1)= 0.851.T$_{i}$($textsc{k}$)+0.055.T$_{w}$($textsc{k}$)+0.094.T$_{o}$($textsc{k}$) Control simulations for various control methods showed the settling time, the overshoot and the steady state nor as follows; infinite time, 3.5$0^{\circ}C$, 3.5$0^{\circ}C$ for ON-OFF control : 30min 2.37$^{\circ}C$, 0.51$^{\circ}C$ for P control; 21min, 0.0$0^{\circ}C$, 0.23$^{\circ}C$ for PI control; 18min 0.0$0^{\circ}C$, 0.23$^{\circ}C$ for PID control, respectively. PI and PID controls appeared to be optimal control methods. There was no effect of differential gain on the heating process but much effect of integral gain on it.on it.

  • PDF

Prediction of Deficiency Pattern in Diabetic Patients Using Multi-frequency Bioimpedance Resistance (다주파수 생체임피던스 저항을 이용한 당뇨병 환자의 허증 변증 예측)

  • Kim, Kahye;Kim, Seul Gee;Cha, Jiyun;Yoo, Ho-Ryong;Kim, Jaeuk U.
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.36 no.3
    • /
    • pp.94-99
    • /
    • 2022
  • The discovery of biomarkers related to pattern identification (PI), the core diagnostic theory of Korean medicine (KM), is one of the methods that can provide objective and reliable evidence by applying PI to clinical practice. In this study, 40 diabetic patients and 41 healthy control subjects recruited from the Korean medicine clinic were examined to determine the human electrical response related to the deficiency pattern, a representative pattern of diabetes. Qi-Blood-Yin-Yang deficiency pattern scores, which are representative deficiency patterns for diabetes mellitus, were obtained through a questionnaire with verified reliability and validity, and the human electrical response was measured non-invasively using a bioimpedance meter. In ANCOVA analysis using gender as a covariate, the 5 kHz frequency resistance and 5-250 kHz frequency reactance were significantly lower in the diabetic group than in non-diabetic control group. In addition, the multiple regression analysis showed a positive correlation (R2=0.11~0.19) between the Yang deficiency pattern score and resistance value for the diabetic group; the correlation was higher at higher frequencies of 50kHz (R2=0.18) and 250kHz (R2=0.19) compared to 5kHz(R2=0.11). In contrast, there was no such significant association in the control group. It implies that bioimpedance resistance measured at finite frequencies may be useful in predicting Yang deficiency, which is closely related to diabetic complications by reflecting the decrease in body water content and metabolism. In the future, large-scale planned clinical studies will be needed to identify biomarkers associated with different types of PI in diabetes.

The Performance Improvement of Excitation System using Robust Control with DATABASE

  • Hong, Hyun-Mun;Jeon, Byeong-Seok;Kim, Jong-Gun;Lee, Sang-Hyuk
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.5 no.1
    • /
    • pp.83-87
    • /
    • 2005
  • This paper deals with the design and evaluation of the robust controller for a synchronous generator excitation system to improve the steady state and transient stability. The nonlinear characteristics of the system is treated as model uncertainties, and then the robust control techniques are introduced into the power system stability design to take into account these uncertainties at the controller design stage. The performance of the designed controller is examined by extensive non-linear time domain simulation. It is shown that the performance of the robust controller is superior to that of the conventional PI controller. This paper also proposes an improved digital exciter control system for a synchronized generator using a digitally designed controller with database. Results show that the proposed control system manifests excellent control performance compared to existing control systems. It has also been confirmed that it is easy for the proposed control system to implement digital control.

Real Time Digital Control of PWM Inverter for Uninterruptible Power Supply(UPS) application (무정전 전원공급장치 적용을 위한 PWM 인버터의 Digital 실시간 제어)

  • Min, Wan-Ki;Lee, Sang-Hun;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1999.11a
    • /
    • pp.56-60
    • /
    • 1999
  • This paper presents the high performance real time control system of PWM inverter for uninterruptible power supply(UPS). This system is based on a digital control scheme which calculates the pulse widths of the inverter switches for the next sampling time in digital signal processor(DSP). A PI compensator is used to eliminate the voltage error caused by the difference between the actual values of LC filter and those designed. Double regulation loops which are the inner current loop and the outer voltage loop are used to make the transient response time reduce in load disturbance and nonlinear load. This method makes it possible to obtain better response in comparison to conventional digital control system. The proposed scheme provides good performance such as stable operation, low THD of the output voltage, and good dynamic response for load variations and nonlinear load.

  • PDF

The Stability Improvement of Brushless DC Motor by Digital PI Control (디지털 PI제어에 의한 브러시리스 직류모터의 안정도 향상)

  • Yoon, Shin-Yong;Baek, Soo-Hyun;Kim, Yong;Kim, Cherl-Jin;Im, Tae-Bin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.1
    • /
    • pp.38-46
    • /
    • 2000
  • This study have established proper mathematical equivalent model of Brushless DC (BLDC) motor and estimated the motor parameter by means of the back-emf measurement as being the step input to the controlled target BLDC motor. And the validity of proposed estimation method is confirmed by the test result of step response. As well, we have designed the reasonable digital controller as a consequence of the root locus method which is obtained from the open-loop transfer function of BLDC motor with hall sensor, and the determination of control gain for variable speed control. Here, revised Ziegler-Nichols tuning method is applied for the proper digital gain establishment, and the system stability is verified by the frequency domain analysis with Bode-plot and experimentation.

  • PDF

Comparative Analysis of PI Controller and Disturbance Cancellation Observer of a Feedforward (비례적분제어기와 feedforward 외란상쇄 관측기의 비교분석)

  • Kim, Young-Choon;Song, Ho-Bin;Cho, Moon-Taek
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.12
    • /
    • pp.3581-3586
    • /
    • 2009
  • This paper designed a robust control of an induction motor using a disturbance cancellation observer of a feedforward control. The speed response of conventional PI controller characteristic is affected by variations of load torque disturbance. In the proposed system, the speed control characteristic used a feedforward control which does not undergo the influence of the load torque disturbance. High speed calculation and processing for vector control is carried out by TMS320C31 digital signal processor. Validity of the proposed control method is verified through simulation and experimental result.

Adaptive Digital Predictive Peak Current Control Algorithm for Buck Converters

  • Zhang, Yu;Zhang, Yiming;Wang, Xuhong;Zhu, Wenhao
    • Journal of Power Electronics
    • /
    • v.19 no.3
    • /
    • pp.613-624
    • /
    • 2019
  • Digital current control techniques are an attractive option for DC-DC converters. In this paper, a digital predictive peak current control algorithm is presented for buck converters that allows the inductor current to track the reference current in two switching cycles. This control algorithm predicts the inductor current in a future period by sampling the input voltage, output voltage and inductor current of the current period, which overcomes the problem of hardware periodic delay. Under the premise of ensuring the stability of the system, the response speed is greatly improved. A real-time parameter identification method is also proposed to obtain the precision coefficient of the control algorithm when the inductance is changed. The combination of the two algorithms achieves adaptive tracking of the peak inductor current. The performance of the proposed algorithms is verified using simulations and experimental results. In addition, its performance is compared with that of a conventional proportional-integral (PI) algorithm.

A study on proportional multiple-resonance controller for harmonic distortion compensation of single phase VSIs (단상 전압 소스 인버터의 고조파 왜곡 보상을 위한 비례 다중 공진 제어기에 관한 연구)

  • Bongwoo Kwak
    • Journal of IKEEE
    • /
    • v.27 no.3
    • /
    • pp.319-326
    • /
    • 2023
  • In this paper, simulation and experimental results are presented, including the implementation of a digital controller for robust output voltage control of a single-phase voltage source inverters (VSIs) and total harmonic distortion (T.H.D.v) analysis. Typically, the VSIs uses a proportional integral (PI) controller for the current controller on the inner loop and a proportional resonant (PR) controller for the voltage controller on the outer loop to control the output voltage. However, non-linear loads still produce high-order odd harmonic distortion. Therefore, in this paper, a proportional multiple resonance (PMR) controller with a resonance controller for odd harmonic frequencies is proposed to suppress harmonic distortion. Analyze the frequency response of controllers for VSI plants and design PMR controllers. Through simulation, the total harmonic distortion characteristics of the output voltage are compared and verified when PI and PMR are used as voltage controllers. Both linear and non-linear loading conditions were considered. Finally, the effectiveness of the PMR controller was demonstrated by applying it to a 3kW VSIs prototype.

A Study On The Speed Control of a BLDC Motor Using DSP (DSP를 이용한 BLDC 전동기의 속도제어에 관한 연구)

  • Hwang, Dong-Won;Kim, Kyoung-Ho;Heo, Du-Suk;Cho, Yun-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2003.04a
    • /
    • pp.101-103
    • /
    • 2003
  • This paper presents the speed control of Brushless DC Motors using PI control. PI control is implemented by software using digital signal processor(DSP) TMS320F240 from Texas instruments. Considering the cost of BLDC Driver A. B. C phase hall IC's signal is used instead of incremental encoder. The Present paper describes, how to control a speed of BLDC Drive.

  • PDF