• 제목/요약/키워드: Digital Measurement

검색결과 2,099건 처리시간 0.029초

Assessment of DVC measurement uncertainty on GFRPs with various fiber architectures

  • Bartulovic, Ante;Tomicevic, Zvonimir;Bubalo, Ante;Hild, Francois
    • Coupled systems mechanics
    • /
    • 제11권1호
    • /
    • pp.15-32
    • /
    • 2022
  • The comprehensive understanding of the fiber reinforced polymer behavior requires the use of advanced non-destructive testing methods due to its heterogeneous microstructure and anisotropic mechanical proprieties. In addition, the material response under load is strongly associated with manufacturing defects (e.g., voids, inclusions, fiber misalignment, debonds, improper cure and delamination). Such imperfections and microstructures induce various damage mechanisms arising at different scales before macrocracks are formed. The origin of damage phenomena can only be fully understood with the access to underlying microstructural features. This makes X-ray Computed Tomography an appropriate imaging tool to capture changes in the bulk of fibrous materials. Moreover, Digital Volume Correlation (DVC) can be used to measure kinematic fields induced by various loading histories. The correlation technique relies on image contrast induced by microstructures. Fibrous composites can be reinforced by different fiber architectures that may lead to poor natural contrast. Hence, a priori analyses need to be performed to assess the corresponding DVC measurement uncertainties. This study aimed to evaluate measurement resolutions of global and regularized DVC for glass fiber reinforced polymers with different fiber architectures. The measurement uncertainties were evaluated with respect to element size and regularization lengths. Even though FE-based DVC could not reach the recommended displacement uncertainty with low spatial resolution, regularized DVC enabled for the use of fine meshes when applying appropriate regularization.

DigitalMicrograph Script Source Listing for a Geometric Phase Analysis

  • Kim, Kyou-Hyun
    • Applied Microscopy
    • /
    • 제45권2호
    • /
    • pp.101-105
    • /
    • 2015
  • Numerous digital image analysis techniques have been developed with regard to transmission electron microscopy (TEM) with the help of programming. DigitalMicrograph (DM, Gatan Inc., USA), which is installed on most TEMs as operational software, includes a script language to develop customized software for image analysis. Based on the DM script language, this work provides a script source listing for quantitative strain measurements based on a geometric phase analysis.

스마트 폰과 이미지 상관법을 이용한 무선 원격 계측 알고리즘 개발 (Development of a Wireless Telemetry Measurement Algorithm Using Smart Phones and Digital Image Correlation)

  • 최인영;강영준;홍경민;김성종;이해규
    • 한국생산제조학회지
    • /
    • 제24권4호
    • /
    • pp.434-440
    • /
    • 2015
  • A smart phone is a multimedia device that is a necessity for modern people. It includes a wireless networking system to share information and pictures. However, numerous smart phones are discarded every year, since they have a very fast technology development cycle. This paper presents the development of a telemetry algorithm to measure displacement and strain with a discarded smart phone and digital image correlation methods. To implement the measurement algorithm, the LabVIEW 2010 program development platform was used. In order to verify reliability, an open hole tension test was conducted using a smart phone and a universal test machine. In addition, the measurement results from the smart phone were compared with FEM analysis results.

이동형 X-ray 발생장치를 이용한 복부 촬영 시 공간 선량률에 관한 연구 (Analysis of Space Radiation Dose Rate using portable X-ray Generating Device for Abdomen)

  • 박창희
    • 대한디지털의료영상학회논문지
    • /
    • 제12권2호
    • /
    • pp.97-101
    • /
    • 2010
  • This experimental study is carried out one of the General Hospital in Kyungbok providence. Abdomen Phantom being located Anterior-posterior(AP) position on portable bed, and the portable X-ray generating device was placed the phantom at $-90^{\circ}$ direction. The experiment were set 65 kVp, 10 mAs, $10{\times}10\;cm^2$, 100 cm(FOD) for the measurement. Digital proportional counting tube survey meter was used for measuring the space scatter dose. Measurement points of horizontal distribution was set up at $30^{\circ}$ interval by increasing 50 cm radius of upside, downside, left and right. Vertical distribution of measurement points were set up for the vertical plane with a radius of at $30^{\circ}$ intervals with 50cm increments. It is concluded that longer distance from the soure of X-ray significantly decrease radiation dose to the patient and use of the radiation protection device should be applied in clinical practice to reduce dose to the patient.

  • PDF

Calibration of digital wide-range neutron power measurement channel for open-pool type research reactor

  • Joo, Sungmoon;Lee, Jong Bok;Seo, Sang Mun
    • Nuclear Engineering and Technology
    • /
    • 제50권1호
    • /
    • pp.203-210
    • /
    • 2018
  • As the modernization of the nuclear instrumentation system progresses, research reactors have adopted digital wide-range neutron power measurement (DWRNPM) systems. These systems typically monitor the neutron flux across a range of over 10 decades. Because neutron detectors only measure the local neutron flux at their position, the local neutron flux must be converted to total reactor power through calibration, which involves mapping the local neutron flux level to a reference reactor power. Conventionally, the neutron power range is divided into smaller subranges because the neutron detector signal characteristics and the reference reactor power estimation methods are different for each subrange. Therefore, many factors should be considered when preparing the calibration procedure for DWRNPM channels. The main purpose of this work is to serve as a reference for performing the calibration of DWRNPM systems in research reactors. This work provides a comprehensive overview of the calibration of DWRNPM channels by describing the configuration of the DWRNPM system and by summarizing the theories of operation and the reference power estimation methods with their associated calibration procedure. The calibration procedure was actually performed during the commissioning of an open-pool type research reactor, and the results and experience are documented herein.

SLR 디지털카메라의 식생관측센서로서의 유효성 검토 (The Availability Examination for Vegetation Measurement of The SLR Digital Camera)

  • 김종환;김응남;전병덕;삼산화일
    • 한국측량학회지
    • /
    • 제27권1호
    • /
    • pp.683-692
    • /
    • 2009
  • 디지털 카메라를 이용한 지상형 원격탐사 기술은 농작물의 생육관리, 법면 녹화의 모니터링 및 환경 평가와 같은 식생평가분야에 유용한 기술로서 기대되고 있다. 본 논문에 서늘 일반적인 목적으로 판매되고 있는 디지털 카메라의 식생 평가분야에의 적용 가능성에 대하여 검토하였다. 그 결과, $\gamma$보정, 적정노출보정을 실시함으로써 시계열 관측 데이터간의 상면조도와 입사 에너지간의 관계를 분석할 수 있었다. 또한, 지상형 원격탐사에 있어서의 촬영 각도, 조도의 영향을 보정하기 위한 모델식을 제안하였다. 평가시험에서는 분광광도계와 디지털 카메라에 의해 구한 NDVI에는 높은 상관관계가 있음을 알 수 있었다.

FHD급 DIC 플랫폼의 변위계측용 영상품질 분석 (Analysis of DIC Platform and Image Quality with FHD for Displacement Measurement)

  • 박종배;강민구
    • 인터넷정보학회논문지
    • /
    • 제19권1호
    • /
    • pp.105-111
    • /
    • 2018
  • 건축 구조물의 상대적인 변위 계측을 위하여 2메가 픽셀 Full HD(FHD) 해상도의 카메라와 디지털 영상상관(DIC, Digital Image Correlation) 플랫폼을 설계하고, 계측에 영향을 주는 영상 품질을 분석하였다. DIC 플랫폼은 Freescale사의 I.MX6를 기반으로 설계하였다. 영상 상관을 이용한 계측은 영상의 품질에 따라 계측 정밀도에 영향을 줄 수 있는데, 이러한 영상 품질 요인으로 영상의 밝기(brightness), 대조(contrast), 신호대 잡음비(SNR, Signal to Noise Ratio)를 분석하였다. 관심 영역(ROI, Region Of Interest)으로 설정한 부분에서 추출한 영상을 기준 영상으로 삼고, 일정 시간 경과 후 디지털 영상 상관(DIC)을 이용하여 기준 영상의 이동을 화소 및 부화소 단위로 추적 계산하여 변위를 측정하였다. 더불어 DIC 기반의 비접촉 원격 계측의 유효성을 파악하기 위하여 25m, 35m, 50m의 계측 거리에서, 영상 품질 요인 및 ROI 의 크기를 조정하여 측정을 하고 정밀도를 분석하였다.

집속 이온빔과 디지털 화상 관련법를 이용한 고 탄소 미세 강선의 잔류 응력 측정 (Measurement of residual stress of steel filaments by using focused ion beam and digital image correlation)

  • 양요셉;배종구;강기주;박찬경
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2007년도 춘계학술대회 논문집
    • /
    • pp.241-245
    • /
    • 2007
  • The residual stress in axial stress in the axial direction of the steel filaments has been measured by using a method based on the combination of the focused ion beam (FIB) and high resolution strain mapping program (VIC-2D). That is, the residual stress was calculated from the measured displacement field before and after the introduction of a slot along the steel filaments. The displacement was obtained by the digital correlation analysis of high-resolution scanning electron micrographs, while the slot was introduced by FIB milling with low energy beam. The present measurement revealed that the residual stress within 8% of the magnitude was persistent in the steel filaments fabricated.

  • PDF

디지털 카메라를 이용한 2D 인체계측법 연구 (A Study on a Measurement Method for 2D Anthropometry using Digital Camera)

  • 손희정;김효숙;최창석;손희순;김창우
    • 복식문화연구
    • /
    • 제11권1호
    • /
    • pp.11-19
    • /
    • 2003
  • This study suggests the new 2D anthropometric method using digital camera. It is used MK2001 program that can convert 2D measurements to 3D measurements. To improve that it is measured 100 college students with direct and indirect anthropometric method. The measurements were processed by the SPSS ver10 Statistical Package. The average, standard deviation, and t-test were calculated for each category. Most measurements by 2D measurements are higher than direct measurements but degree. The difference between direct and indirect measurements is less than 2cm. In the results of t-test, height measurements including other 16 measurements which is easy to measure have no meaningful difference within 1cm. The depth measurements are most high difference. The result of each measurement proves that MK2001 program (2D anthropometry method using digital camera) is available for measuring the human body.

  • PDF

계전기를 위한 고속의 주교수 계측 알고리즘 (The Study of Fast Frequency Measurement Technique for Protection Relay)

  • 김병진;이창호;박종찬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.211-213
    • /
    • 2005
  • In this paper, the frequency compensator for digital protective relay is introduced. Due to sudden appearance of generation-load or fault in power system, the frequency can deviate from its nominal value. The Orthogonal filter adopted to digital protective relay is exposed to the problem. Therefore, the frequency variation makes a difficult to protective function and power measurement in digital protective relay. The essential property of the proposed algorithm presented is its outstanding immunity to both signal orthogonal component magnitudes and DFT filter gain variations which ensures below 0.05Hz accuracy of estimation. Additionally, the proposed method has excellent characteristics with low signal sampling rate. Based on the frequency estimation, author design under frequency protection relay for generator and verifies its performance with several experimental tests.

  • PDF