• Title/Summary/Keyword: Digital Kit

Search Result 60, Processing Time 0.031 seconds

A Study on the Development of Magnetic Levitation Experiment Kits (자기 부상 실습 장치의 개발에 관한 연구)

  • Lee Jeong-Woo;Cheong Yeon-Doo;Han Myoung-Keun
    • Journal of Engineering Education Research
    • /
    • v.8 no.1
    • /
    • pp.5-19
    • /
    • 2005
  • This paper describes the design and fabrication of magnetic levitation kits for use in the hands on experiments of automatic control, digital control and microprocessor applications in the division of mechatronics in Samcheok university. The kits are developed inspired by MIT's design, but it is designed on the digital basis, whereas MIT's is designed on the analog basis. As a result, the kits can be monitored and controlled on the analog and digital control techniques. Furthermore, the cost of kit components is comparable or lower to that of MIT design. And the kits can be controlled with magnetic hall sensors and/or infrared sensors, which provides more versatile experience on the use of sensors and signal filtering to the students. The design is fabricated and tested by authors and will be provided to the students as lab projects. The kits will be intentionally presented with a device that is poorly instrumented and poorly compensated. And the students are expected to analyze sensor signal and controller performance, and then, perform compensator design and signal filtering.

Convergence study on anti-caries effect of chlorhexidine and essential oils (클로르헥시딘과 에센셜 오일의 항우식 효과에 대한 융합 연구)

  • Lee, Su-Young
    • Journal of Digital Convergence
    • /
    • v.14 no.10
    • /
    • pp.367-373
    • /
    • 2016
  • The aim of this study was to evaluate the anti-caries effect of the essential oils and chlorhexidine mouth rinse. 42 subjects were randomized allocated to the chlorhexidine (n=22) and essential oils group (n=20). Subjects were instructed to rinsing each mouthwash by 15 ml once a day during the 7 days. The CRT and Cariview scores were recorded at baseline and 4 weeks after treatment. Data was analysed by using PASW 18.0 program with independent t-test and paired t-test. After 1 month, Cariview score was shown reducing compare to baseline. However, there were no significant differences between the groups. High risk level of MS and LB was decreased to 9~15% after treatment in two groups. Both of the chlorhexidine and essential oils mouth wash showed an antiplaque effect. Although chlorhexidine continues to be the "gold standard" in terms of antiplaque effect, essential oils could be considered a reliable alternative antimicrobial agent.

Emotion and Sentiment Analysis from a Film Script: A Case Study (영화 대본에서 감정 및 정서 분석: 사례 연구)

  • Yu, Hye-Yeon;Kim, Moon-Hyun;Bae, Byung-Chull
    • Journal of Digital Contents Society
    • /
    • v.18 no.8
    • /
    • pp.1537-1542
    • /
    • 2017
  • Emotion plays a key role in both generating and understanding narrative. In this article we analyzed the emotions represented in a movie script based on 8 emotion types from the wheel of emotions by Plutchik. First we conducted manual emotion tagging scene by scene. The most dominant emotions by manual tagging were anger, fear, and surprise. It makes sense when the film script we analyzed is a thriller-genre. We assumed that the emotions around the climax of the story would be heightened as the tension grew up. From manual tagging we could identify three such duration when the tension is high. Next we analyzed the emotions in the same script using Python-based NLTK VADERSentiment tool. The result showed that the emotions of anger and fear were most matched. The emotion of surprise, anticipation, and disgust, however, scored lower matching.

A Compatibility Assessment and Verification of Suitable to DICOM of PACS DATA CD : Current Situation Investigation of Korea (PACS DATA CD의 호환성 평가 및 DICOM 적합성에 대한 검증을 통한 기준 제시)

  • Jeong, Jae-Ho;Sung, Dong-Wook;Park, Bum-Jin;Son, Gi-Gyeong;Kang, Hui-Doo
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.10 no.1
    • /
    • pp.29-34
    • /
    • 2008
  • Purpose To analyze the input and output error of data CD which records the image information and the problems of the server of the compatibility. And to report a compatibility assessment and verification of suitable to DICOM of PACS data CD with investigation of current situation of Korea METHOD AND MATERIALS Date CD of each 8 vendors in 30 hospitals was analyzed. We grasped a main verification element existence of a generation compatibility of data CD. The items of element are media identification, DICOM compression, DICOM viewer send, specified object information modify, auto-run, DICOM content type, etc, and give 1 point for each item. We divided the assessment about an each item into 5 levels. Verification about. DICOM conformance by using DICOM validation tool kit is shown to be classified pass or fail according to error occurrence of tag valus. Classify the prequency of tag occurrence as the item. RESULTS The average point of date CD compatibility is 8 point (very good), lowest is 5 point (6.6%), and highest is 10 point (23%_. Most high occurrence frequency's distribution is 7 point (36.6%). As a result of verification about DICOM conformance, PASS in 8 occurrence frequency's distribution is 7 point (36.6%). As a result of verification about DICOM maximum length numbers (14 items), DICOM error of modality (10 items), discord of pixel data length (6 items). etc.

  • PDF

Anti-Obesity Effect of Herbal Mixture Powder and Water Extracts in Mice Fed a High Fat Diet (나복자, 의이인, 백복령, 다엽, 차전자피로 구성된 혼합분말제(HP)와 진피, 산사, 옥미수, 양총피로 구성된 혼합열수추출물(HE)이 고지방식이로 유도된 비만마우스에 미치는 항비만 효과)

  • Youn, Jedong;Choi, Yunhee
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.19 no.1
    • /
    • pp.131-144
    • /
    • 2015
  • Objective : This study was conducted to investigate anti-obesity effects of mixed-Powder(Raphani Semen, Coicis Semen, Poria, Plantaginis Testa & Theae folium)(HP) & mixed water extract(Citri Pericarpium, Crataegi Fructus, Maydis Stigma, Allium Skin) (HE) in mice fed a high-fat diet. Method : 50 Female ICR mice were divided into six groups; Normal group (Ve), high-fat diet group (Po), Po+HP(0.6g/kg) group(HP), Po+HE(1g/kg) group(HE), Po+(HP+HE) group(HPE), Po+(HP+HE)*2 group(DHPE). For 8 weeks, these groups were fed their respective diets. Body weight, liver weight and weights of adipose tissues, GOT/GPT index changes & Blood Glucose index changes were measured respectively. Lipid profiles in serum were analyzed by kit of blood. Results : Groups HP, HE, HPE, DHPE had significantly reduced body weight, liver weight, adipose tissue weights and GOT/GPT index, blood glucose index compared to the Po group. Also, serum triglyceride and total cholesterol, low density lipoprotein, were significantly reduced when compared to the Po group. Group G1 had significantly increased high density lipoprotein levels. Conclusion : Mixed powder (HP) & mixed water extract (HE) show anti-obesity effects in mice fed a high-fat diet.

Implementation of 16Kpbs ADPCM by DSK50 (DSK50을 이용한 16kbps ADPCM 구현)

  • Cho, Yun-Seok;Han, Kyong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.1295-1297
    • /
    • 1996
  • CCITT G.721, G.723 standard ADPCM algorithm is implemented by using TI's fixed point DSP start kit (DSK). ADPCM can be implemented on a various rates, such as 16K, 24K, 32K and 40K. The ADPCM is sample based compression technique and its complexity is not so high as the other speech compression techniques such as CELP, VSELP and GSM, etc. ADPCM is widely applicable to most of the low cost speech compression application and they are tapeless answering machine, simultaneous voice and fax modem, digital phone, etc. TMS320C50 DSP is a low cost fixed point DSP chip and C50 DSK system has an AIC (analog interface chip) which operates as a single chip A/D and D/A converter with 14 bit resolution, C50 DSP chip with on-chip memory of 10K and RS232C interface module. ADPCM C code is compiled by TI C50 C-compiler and implemented on the DSK on-chip memory. Speech signal input is converted into 14 bit linear PCM data and encoded into ADPCM data and the data is sent to PC through RS232C. The ADPCM data on PC is received by the DSK through RS232C and then decoded to generate the 14 bit linear PCM data and converted into the speech signal. The DSK system has audio in/out jack and we can input and out the speech signal.

  • PDF

Real-time Markerless Facial Motion Capture of Personalized 3D Real Human Research

  • Hou, Zheng-Dong;Kim, Ki-Hong;Lee, David-Junesok;Zhang, Gao-He
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.14 no.1
    • /
    • pp.129-135
    • /
    • 2022
  • Real human digital models appear more and more frequently in VR/AR application scenarios, in which real-time markerless face capture animation of personalized virtual human faces is an important research topic. The traditional way to achieve personalized real human facial animation requires multiple mature animation staff, and in practice, the complex process and difficult technology may bring obstacles to inexperienced users. This paper proposes a new process to solve this kind of work, which has the advantages of low cost and less time than the traditional production method. For the personalized real human face model obtained by 3D reconstruction technology, first, use R3ds Wrap to topology the model, then use Avatary to make 52 Blend-Shape model files suitable for AR-Kit, and finally realize real-time markerless face capture 3D real human on the UE4 platform facial motion capture, this study makes rational use of the advantages of software and proposes a more efficient workflow for real-time markerless facial motion capture of personalized 3D real human models, The process ideas proposed in this paper can be helpful for other scholars who study this kind of work.

Patent Analysis in the Clinical Diagnosis Sector : Before and After COVID-19 (COVID-19 전후 의료 진단 특허 출원 동향 분석)

  • Han, Yoojin;Park, Sunju
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.26 no.2
    • /
    • pp.25-35
    • /
    • 2022
  • Objectives : This study aims to analyze the patents filed in the clinical diagnosis sector where technologies have been actively developed since the advent of the 4th industrial revolution. Methods : The analysis has been conducted in two ways - the period from 2016 to 2021 and the time points before and after COVID-19 - by visualizing based on the word cloud method. Results : Over two thirds of patents has been filed in the A61B sector (71.8%) and cure, sensor, self diagnosis, control, and breakdown have been observed in the period above. During the overall period (2016~2021), 'ultrasound'(7.5%), 'image'(5.1%), 'skin'(4.0%), 'treatment'(3.4%), and 'artificial intelligence(2.5%)' were the frequently patent applications technologies. In addition, 'ultrasound'(6.2%), 'image'(5.5%), 'skin'(4.0%), 'treatment' (3.7%), and 'portable'(1.7%) appeared most frequently before COVID-19 whereas 'ultrasound(5.5%)', 'artificial intelligence(4.2%)', 'diagnostic device'(1.9%), 'dimentia'(1.6%), and 'diagnostic kit'(1.4%) emerged the most after COVID-19. Conclusion : This study is meaningful in that it showed the technological development trend in the digital diagnosis sector and it was found that the Korean medicine field should contribute to this field more actively in the future.

Estimation of viscosity of by comparing the simulated pressure profile from CAE analysis with the Long Fiber Thermoplastic(LFT) measuring cavity pressure (Long Fiber Thermoplastic(LFT) 사출성형 공정에서 캐비티 내 압력 측정 및 CAE해석을 활용한 점도 추정)

  • Lim, Seung-Hyun;Jeon, Kang-Il;Son, Young-Gon;Kim, Dong-Hak
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.4
    • /
    • pp.1982-1987
    • /
    • 2011
  • In this study, we proposed a new method that can estimate viscosity curves of unknown samples or high viscous resins like LFT(Long Fiber Thermoplastics). First, we built the system that could detect the pressure of melt during filling the cavity in a mold. It consists of both pressure sensors which are installed in a mold and the Kit which can convert analog signal to digital signal. The kit measures the melt pressure in mold cavity. We could also simulate the cavity pressure during filling process with commercialized CAE softwares(ex, Moldflow). If the viscosity data in CAE Database were correct, the simulated pressure profile coincided with the measured one. According to our proposed algorithm, we obtained correct viscosity data by iterating the process of comparing the simulated profile with the measured one until both coincided each other. In order to verify this algorithm, we selected well-defined PP resin and concluded that the experimental profile comply with the CAE profile. We could also estimate the optimized viscosity curves for PP-LFT by applying our method.

Comparison of traditional and simplified methods for repairing CAD/CAM feldspathic ceramics

  • Carrabba, Michele;Vichi, Alessandro;Louca, Chris;Ferrari, Marco
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.4
    • /
    • pp.257-264
    • /
    • 2017
  • PURPOSE. To evaluate the adhesion to CAD/CAM feldspathic blocks by failure analysis and shear bond strength test (SBSt) of different restorative systems and different surface treatments, for purpose of moderate chipping repair. MATERIALS AND METHODS. A self-adhering flowable composite (Vertise Flow, Kerr) containing bi-functional phosphate monomers and a conventional flowable resin composite (Premise Flow, Kerr) applied with and without adhesive system (Optibond Solo Plus, Kerr) were combined with three different surface treatments (Hydrofluoric Acid Etching, Sandblasting, combination of both) for repairing feldspathic ceramics. Two commercial systems for ceramic repairing were tested as controls (Porcelain Repair Kit, Ultradent, and CoJet System, 3M). SBSt was performed and failure mode was evaluated using a digital microscope. A One-Way ANOVA (Tukey test for post hoc) was applied to the SBSt data and the Fisher's Exact Test was applied to the failure analysis data. RESULTS. The use of resin systems containing bi-functional phosphate monomers combined with hydrofluoric acid etching of the ceramic surface gave the highest values in terms of bond strength and of more favorable failure modalities. CONCLUSION. The simplified repairing method based on self-adhering flowable resin combined with the use of hydrofluoric acid etching showed high bond strength values and a favorable failure mode. Repairing of ceramic chipping with a self-adhering flowable resin associated with hydrofluoric acid etching showed high bond strength with a less time consuming and technique-sensitive procedure compared to standard procedure.