• Title/Summary/Keyword: Digital Image System

Search Result 2,064, Processing Time 0.028 seconds

Wireless Triggering Pulse Generation for Digital X-ray Imaging System (디지털 x-ray 영상시스템을 위한 무선 트리거 발생기)

  • Ko, Dae-Sik;Lee, Jae-Cheol;Lee, Joo-Shin
    • Journal of Advanced Navigation Technology
    • /
    • v.11 no.2
    • /
    • pp.163-169
    • /
    • 2007
  • In this paper, we propose a method of trigger pulse generation to capture the image on time by making a synchronization between the x-ray generator and digital x-ray image acquisition system. we designed a wireless trigger pulse generation circuit to make a synchronization between x-ray generator and digital image acquisition system and analysis its performance. When it starts to detect a certain level of x-ray radiation or above from the air, this method starts to generate a ACQ_START signal to indicate the timing for image acquisition starting from digital image acquisition system. Hence, when it starts to detect under certain level of x-ray signal from the air, this method starts to generate a ACC_END signal to indicate the timing for image acquisition stop from digital image acquisition system. Image acquisition is activated only this time between ACQ_START and ACQ_END signal. By doing this wireless detecting of x-ray signal from remote, we can get more accurate timing for capturing the x-ray image and any type of x-ray generator can be connected to digital image acquisition system, regards of wired protocol. This makes easy installation. We could get 3.5 line pair / mm resolution at 20 mAs of x-ray level with resolution chart. This is same or better image comparing to conventional wired result.

  • PDF

Implementation of an improved real-time object tracking algorithm using brightness feature information and color information of object

  • Kim, Hyung-Hoon;Cho, Jeong-Ran
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.5
    • /
    • pp.21-28
    • /
    • 2017
  • As technology related to digital imaging equipment is developed and generalized, digital imaging system is used for various purposes in fields of society. The object tracking technology from digital image data in real time is one of the core technologies required in various fields such as security system and robot system. Among the existing object tracking technologies, cam shift technology is a technique of tracking an object using color information of an object. Recently, digital image data using infrared camera functions are widely used due to various demands of digital image equipment. However, the existing cam shift method can not track objects in image data without color information. Our proposed tracking algorithm tracks the object by analyzing the color if valid color information exists in the digital image data, otherwise it generates the lightness feature information and tracks the object through it. The brightness feature information is generated from the ratio information of the width and the height of the area divided by the brightness. Experimental results shows that our tracking algorithm can track objects in real time not only in general image data including color information but also in image data captured by an infrared camera.

The Study on image correction of geometric distortion in digital radiography image (방사선투과영상의 기하학적 왜곡 보정에 관한 연구)

  • Park, S.K.;Ahn, Y.S.;Gil, D.S.
    • Journal of Power System Engineering
    • /
    • v.15 no.4
    • /
    • pp.25-30
    • /
    • 2011
  • This study is made to provide with a method for correcting the geometric distortion of the digital radiography image by analytical approach based upon the inverse square law and Beer's law. This study is aimed to find out and improve a mathematic model of nonlinear type. Variations in the alignment of the X-ray source, the object, and imaging plate affect digital radiography images. A model which is expressed in parameter values; e.g, angle, position, absorption coefficient, length, width and pixel account of radiography source, is developed so as to match the sample image. For the best correction of the digital image that is the most similar to the model image, a correction technique based upon tangent is developed; then applied to the digital radiography images of steel tubes. As a result, the image correction is confirmed to be made successfully.

A study on the automatic batch management system for the image contents (이미지 콘텐츠 일괄 자동화 관리기술에 대한 연구)

  • Choi, Jae-Wan;Kim, Tae-Eun
    • Journal of Digital Contents Society
    • /
    • v.9 no.2
    • /
    • pp.341-348
    • /
    • 2008
  • As a high-speed growth of internet infrastructure and a fast supply of digital imaging devices, a digital image contents industrialization is growing fast. Digital image contents are represented as digitalized images for recognition by the computer. This paper proposes the customized stock image contents management system for digital image contents developers and UCC contents producers. For automatic batch management of image contents, we design the system using the techniques of stock image meta-data conversion to want, image contents format conversion to want and selective image contents uploading to want. Furthermore, constructed system can be embedded to a system easy and fast. It provides efficient work environment as appling conventional systems and contributes for user-friendly interface construction.

  • PDF

Reconstitution of Digital Multiplanar Images based on Cinerama System (시네라마 시스템 기반의 디지털 다면영상의 재구성)

  • Moon, Dae-Hyuk
    • Journal of Digital Contents Society
    • /
    • v.14 no.4
    • /
    • pp.439-445
    • /
    • 2013
  • The development of digital image technology has realized high definition throughout the image industry including film and broadcasting. Such high definition images are used in various media and forms through convergence with innovative displays. The analog image production mode is combined with image content production using digital technology. The purpose of this research is to present a method to reconstitute high definition multiplanar images on the wider and bigger screen by applying the Cinerama system, one of the analog image systems in the past, to digital technology.

The Study on Image Sensitivity Evaluation For Digital Radiography Image (디지털 방사선 투과영상의 식별도 평가 연구)

  • Park, S.K.;Lee, Y.H.
    • Journal of Power System Engineering
    • /
    • v.12 no.6
    • /
    • pp.70-77
    • /
    • 2008
  • The purpose of this study is to compare the quality of digital radiography image with that of classical film images for welded structure in power plants. The CMOS(Complementary Metal Oxide Semiconductor) flat panel detecter and Agfa D5 film are used to image flaw specimens respectively. In the test, CMOS flat panel detector has been determined to have a better image than that of film image. In the IQI(Image Quality Indicator) transmission test, one or two more line can be seen in digital image than in film image. Digital Radiography Test enabled to successfully detect all defects on the weld specimens fabricated with real reheat stem pipe and boiler tube as well. In the specific comparison test, Digital radiography test detected micro flaws in the size of 0.5 mm in length by 0.5 mm in depth. However, film test has limited it to 1.0 mm in length by 1.0 mm in depth. As a result of this study, digital radiography technology is estimated well enough to perform the inspection in the industry with far more cost effective way, compared to the classical film test.

  • PDF

The research on Full Field Digital Mammography Image Quality in PACS Environment (PACS환경에서 디지털유방엑스선 영상 화질에 관한 연구)

  • Jung, Jae-Ho
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.16 no.2
    • /
    • pp.25-29
    • /
    • 2014
  • The full-field digital mammography (FFDM), which has been known as a digital breast imaging system, carries out more outstanding performance than the screen-film mammography in overall image quality, skin & nipple, description of pectoral muscle and expression of micro-calcification. Thus, in this thesis, I perform experiments for both the enhancement of image quality and accurate estimation of the result in question, when detecting the very tiny-sized lesions in mammography. The image of digital breast X-rays is the important diagnostic tool for detecting early breast cancer and micro calcification lesion. The experiment of how much compression rate has an effect on the result of diagnosis in the case of microcalcification lesion, with JPEG2000 40:1 compression and over 50% enlargement led to obscure or definitely unacceptable diagnostic results is performed. And in another study of assessment of PSNR degree. I recognized the importance of standardized management system in mammography, where not to mention the accurate reading of the image has the most crucial role in diagnosis

  • PDF

Image Quality Evaluation of Medical Image Enhancement Parameters in the Digital Radiography System (디지털 방사선시스템에서 영상증강 파라미터의 영상특성 평가)

  • Kim, Chang-Soo;Kang, Se-Sik;Ko, Seong-Jin
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.6
    • /
    • pp.329-335
    • /
    • 2010
  • Digital imaging detectors can use a variety of detection materials to convert X-ray radiation either to light or directly to electron charge. Many detectors such as amorphous silicon flat panels, CCDs, and CMOS photodiode arrays incorporate a scintillator screen to convert x-ray to light. The digital radiography systems based on semiconductor detectors, commonly referred to as flat panel detectors, are gaining popularity in the clinical & hospital. The X-ray detectors are described between a-Silicon based indirect type and a-Selenium based direct type. The DRS of detectors is used to convert the x-ray to electron hole pairs. Image processing is described by specific image features: Latitude compression, Contrast enhancement, Edge enhancement, Look up table, Noise suppression. The image features are tuned independently. The final enhancement result is a combination of all image features. The parameters are altered by using specific image features in the different several hospitals. The image in a radiological report consists of two image evaluation processes: Clinical image parameters and MTF is a descriptor of the spatial resolution of a digital imaging system. We used the edge test phantom and exposure procedure described in the IEC 61267 to obtain an edge spread function from which the MTF is calculated. We can compare image in the processing parameters to change between original and processed image data. The angle of the edge with respect to the axes of detector was varied in order to determine the MTF as a function of direction. Each MTF is integrated within the spatial resolution interval of 1.35-11.70 cycles/mm at the 50% MTF point. Each image enhancement parameters consists of edge, frequency, contrast, LUT, noise, sensitometry curve, threshold level, windows. The digital device is also shown to have good uniformity of MTF and image parameters across its modality. The measurements reported here represent a comprehensive evaluation of digital radiography system designed for use in the DRS. The results indicate that the parameter enables very good image quality in the digital radiography. Of course, the quality of image from a parameter is determined by other digital devices in addition to the proper clinical image.

Study on Improvement of Measurement Precision in Digital Image Correlation Measurement Method by Using Subpixel Algorithms (이미지 상관법의 서브 픽셀 알고리즘을 이용한 측정 분해능 향상에 관한 연구)

  • Kim, Seung Jong;Kang, Young Jun;Choi, In Young;Hong, Kyung Min;Ryu, Won Jea
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.12
    • /
    • pp.1039-1047
    • /
    • 2015
  • Contact type sensors (e.g., displacement sensor and strain gauge) were typically used to evaluate the safety and mechanical properties in machines and construction. However, those contact type sensors have been constrained because of measurement problems such as surface roughness, temperature, humidity, and shape. The Digital Image Correlation (DIC) measurement system is a vision measurement system. This measurement system uses the taken image using a CCD camera and calculates the image correlation between the reference image and the deformed image under external force to measure the displacement and strain rates. In this paper, we discuss methods to improve the measurement precision of the digital image correlation measurement system. A tensile test was conducted to compare the precision improvement effects, by using the universal test machine and the DIC measurement system, with the use of subpixel algorithms, i.e., the Coarse Fine Search (CFS) algorithm and the Peak Finding (PF) algorithm.

Study on the Digital VCR System and Its Image Enhancement Techniques (디지털 VCR의 영상압축 기술 및 그의 화질 개선에 관한 연구)

  • 이형호;백준기
    • Journal of Broadcast Engineering
    • /
    • v.1 no.2
    • /
    • pp.142-151
    • /
    • 1996
  • The digital video cassette recorder(DVCR) is considered as next generation VCR due to its performance breakthrough in various aspects, such as digital recording and various digital image processing techniques. The purpose of our study is to understand the standardized specifications of the DVCR system, evaluate the performance of the system, and improve the quality of the reconstructed DVCR image. More specifically, in order to enhance the DVCR Image we consider a series of discrete cosine transform(DCT), quantization, inverse DCT, and Inverse quantization as a degradation process of the Imaging system, and propose a fast adaptive image restoration algorithm for reducing blocking artifacts.

  • PDF