• Title/Summary/Keyword: Digital Health

Search Result 2,287, Processing Time 0.026 seconds

Comparative Analysis between Directly Measured Diameter in 2D Angiography and Cross-Sectional Area-Converted Diameter in MR Image (2D 혈관조영술에서 직접 측정한 혈관 직경과 MR 영상에서 단면적 기반 환산 직경의 비교 분석)

  • Ki-Baek Lee;Mi-Hyeon Kim
    • Journal of radiological science and technology
    • /
    • v.46 no.5
    • /
    • pp.427-433
    • /
    • 2023
  • This study aimed to quantitatively compare the diameters measured directly from the coronal plane or sagittal plane of 2D digital subtraction angiography (DSA) and the cross-sectional area-converted diameters calculated from contrast-enhanced MR (CE-MR) imaging. A retrospective analysis was conducted on 20 patients who underwent both 2D DSA and CE-MR imaging. Firstly, the venous diameters of the superior sagittal sinus (SSS) and transverse sinus (TS) were directly measured from 2D DSA. Subsequently, the axial planes for SSS diameter and the sagittal plane for TS in CE-MR imaging were utilized to calculate cross-sectional area-based converted diameters. The numerical values obtained from 2D DSA and CE-MR imaging were compared pairwise at each location. For SSS, the diameter measured by 2D DSA was 27% larger than the conversion-based diameter from CE-MR imaging (9.8±1.4 mm vs. 7.1±1.3 mm, P<0.05). Similarly, for the right TS, the difference was 16% (8.8±3.2 mm vs. 7.4±2.0 mm, P<0.05), and for the left TS, the difference was 22% (8.4±2.8 mm vs. 6.6±1.3 mm, P<0.05). In conclusion, the diameter measured directly in conventional 2D DSA may be larger than the diameter converted based on the cross-sectional area. Therefore, when selecting the size of the stent, it is crucial to make precise determinations while keeping this fact in mind.

Usefulness of an Auxiliary Tool for Hand Radiography by Using 3D Printing (3D 프린팅을 이용한 손 엑스선 검사 보조도구의 유용성)

  • Ji-Won Kim;Bon-Yeoul Koo
    • Journal of radiological science and technology
    • /
    • v.46 no.6
    • /
    • pp.485-491
    • /
    • 2023
  • As an auxiliary tool for fixing the patient's posture when taking an X-ray, sponges with high radiolucencies are laminated in various thicknesses. This study aimed to evaluate the usefulness of an auxiliary tool for hand oblique projection X-ray by manufacturing it with a uniform thickness by 3D printing and comparing it with existing sponge tools. In the auxiliary tool, radiolucency was measured at the stairs where each finger was located, and pixel information values were compared in the digital imaging and communications in medicine(DICOM) image. Contrast to noise ratio(CNR) and signal to noise ratio(SNR) were compared by shooting the hand phantom and the auxiliary tool together. As the thickness of the sponge tool increased, radiolucency decreased by 15.52% and pixel information value increased by 20.61%. The transmittance of the 3D printing tool increased by 0.82%, and the pixel information value differed by 5.66%. CNR and SNR increased by 20.03% and 22.42% in 3D printing compared to existing sponge tools. while taking hand oblique projection, maintaining the thickness of the auxiliary tool uniformly through 3D printing maintains high radiolucency and minimal impact on medical images, and increases CNR and SNR, making it useful as an auxiliary tool for taking hand oblique projection.

Distribution of Skill and Encouraging Motivation to Enhance Resilience: Evidence from Accounting Personnel During COVID-19 Crisis

  • Yamuna Rani PALANIMALLY;Mohd Danial Afiq Khamar TAZILAH;Zam Zuriyati MOHAMAD;Meenah RAMASAMY;Mohamad Rohieszan RAMDAN;Dayang Rafidah SYARIFF M. FUAD;Noral Hidayah ALWI
    • Journal of Distribution Science
    • /
    • v.22 no.2
    • /
    • pp.41-50
    • /
    • 2024
  • Purpose: This study aims to identify the distribution of skill evolution for accounting personnel during the health crisis and investigate the impact of accounting skills in developing resilience among accounting personnel. Research design, data, and methodology: A total of 131 respondents of accounting personnel participated in a self-administered survey questionnaire. This data is analysed using the partial least square structural equation modeling. Results: The results show that accounting skills, digital skills, and writing skills have a significant impact on developing accounting personnel's motivation, subsequently leading to resilience. Conclusions: This study adds to the literature on the new requirements and future profiles of Malaysian organisation and the accounting profession. This will be a good reference for the practitioners to identify the relevant skills required for accountants after the pandemic. Furthermore, this study includes encouraging motivation and skills to improve resilience in the Malaysian context further to understand the push factors on skills evolution among the accountants. Higher education institutions with accounting courses would consider the potential future skills of accountants to meet market demands on time when updating the institutions' curricula program. Hence, the relevant skills required can be developed and practiced at the education level, especially secondary and tertiary levels.

Assessment of infection control in oral radiology during the COVID-19 outbreak: An international collaborative study

  • Rafaela C Santos;Larissa S Araujo;Rafael B Junqueira;Eliana D Costa;Fernanda M Pigatti;Kivanc Kamburoglu;Pedro HB Carvalho;Manuela LB Oliveira;Sibele N Aquino;Francielle S Verner
    • Imaging Science in Dentistry
    • /
    • v.53 no.4
    • /
    • pp.365-373
    • /
    • 2023
  • Purpose: In the context of COVID-19, studies evaluating the adherence of dentists and dental students to infection control are relevant due to their high occupational exposure and risk, as well as their responsibility for disseminating information and good practices. This study evaluated the adherence of dentists and dental students to infection control in the oral radiology field in the setting of the COVID-19 pandemic on different continents. Materials and Methods: This cross-sectional observational study involved individuals who performed intraoral radiographic examinations during the COVID-19 pandemic. The Questionnaire on Infection Control in Oral Radiology was administered virtually using a Google Form. Participants from different continents(the Americas, Africa, Europe, Asia, and Oceania) were recruited. Data were subjected to descriptive analysis and simple and multiple binary regression (5%). Results: There were 582 valid answers, and 68.73% of the participants were from the Americas, 18.90% from Europe, and 12.37% from Asia. The median score for infection control protocols was 94 points for dental students and 104 points for dentists, and participants below the median were considered to have low adherence to infection control in oral radiology. Low access to infection control was found for 53.0% of dentists in the Americas, 34.0% from Europe, and 26.9% from Asia. Conclusion: The adherence to infection control protocols in oral radiology was low even in the face of the COVID-19 pandemic. The results may help improve the awareness of students and professionals, since oral radiology routines have the potential for transmitting COVID-19.

A Study on Applying Novel Reverse N-Gram for Construction of Natural Language Processing Dictionary for Healthcare Big Data Analysis (헬스케어 분야 빅데이터 분석을 위한 개체명 사전구축에 새로운 역 N-Gram 적용 연구)

  • KyungHyun Lee;RackJune Baek;WooSu Kim
    • The Journal of the Convergence on Culture Technology
    • /
    • v.10 no.3
    • /
    • pp.391-396
    • /
    • 2024
  • This study proposes a novel reverse N-Gram approach to overcome the limitations of traditional N-Gram methods and enhance performance in building an entity dictionary specialized for the healthcare sector. The proposed reverse N-Gram technique allows for more precise analysis and processing of the complex linguistic features of healthcare-related big data. To verify the efficiency of the proposed method, big data on healthcare and digital health announced during the Consumer Electronics Show (CES) held each January was collected. Using the Python programming language, 2,185 news titles and summaries mentioned from January 1 to 31 in 2010 and from January 1 to 31 in 2024 were preprocessed with the new reverse N-Gram method. This resulted in the stable construction of a dictionary for natural language processing in the healthcare field.

A Survey on the Athleisure Wear Wearing Condition of Korean Men in Their 20s and 30s (국내 20, 30대 남성의 애슬레저웨어 착용실태조사)

  • Eun-Kyong Kim
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.26 no.1
    • /
    • pp.45-60
    • /
    • 2024
  • This study analyzes the athleisure wear purchase status, wearing conditions, and design preferences of men in their 20s and 30s and provides basic data for the development of men's athleisure wear that reflects consumer preferences. An online survey was conducted on 200 men from August 23 to August 27, 2023. The questionnaire consisted of a total of 48 questions, including 8 questions about the respondent's general information, 19 questions about the purchase status of athleisure wear, 6 questions about the status of wearing athleisure wear, and 15 questions about athleisure wear design preferences. The survey results are as follows. The most common motive for exercise participation was 'maintaining health.' 'Nike' was the most preferred and purchased brand among athleisure wear brands, and the main place of purchase of athleisure wear was 'Internet and mobile shopping malls', reflecting the recent purchasing trend of the MZ generation. When purchasing athleisure wear, the most common selection criterion was 'design', followed by 'fitting comfort', 'possibility to use as daily wear', and 'price'. The most common route to obtain purchase information was 'Internet search', and the 'overall satisfaction' with athleisure wear was found to be satisfactory with an average of 3.83. The most common reason for wearing athleisure wear was 'because it is comfortable to do activities', followed by 'because it can be used as everyday wear'. Lastly, 'black', 'short-sleeved t-shirt', 'short length' sleeve, 'round neckline', 'waist length', and 'relaxed loose fit' were preferred for the top design, and 'black', 'shorts', 'full elastic type' waistband, 'regular fit that fits the body well' were preferred for the bottom design.

Ergonomic Approach through Process Analysis of Delivery Work (택배 배송 작업의 공정분석을 통한 인간공학적 접근 방안)

  • Sejung Lee;Sangeun Jin;Seong Rok Chang
    • Journal of the Korean Society of Safety
    • /
    • v.39 no.1
    • /
    • pp.55-61
    • /
    • 2024
  • In response to the COVID-19 pandemic, the logistics industry in Korea has rapidly been expanding, with offline demand concentrating on online platforms owing to the development of digital infrastructure. This has increased the workload of courier drivers considerably, along with labor intensity. A delivery driver died recently from overwork due to the continuous increase in delivery volume, which raises social concerns. Delivery drivers work long hours, (over 12 hours) and are greatly affected by weather conditions, such as snow, rain, heat waves, and cold waves. In addition, they lack a fixed workplace; perform atypical work handling workpieces of various sizes, weights, and shapes; and spend a large amount of time driving as part of their work. This work involves a high level of tension and requires attention and concentration. Despite the frequency of industrial accidents in the courier industry, studies on safety and health to quantitatively analyze and systematize the work of courier workers are very scarce. Therefore, to define the work process necessary for investigating the harmful factors in delivery service and the work analysis, this study conducted interviews and on-site surveys to analyze the unit work of the delivery service by targeting delivery workers. In other words, a framework of unit work for work analysis was presented to enable research and analysis by considering the aforementioned characteristics of the courier industry. The process was broadly divided into work, transport, storage, delay, and inspection. Work was divided into loading, sorting, unloading, and door subcategories, and transportation was divided into vehicle, cart, and walking subcategories as well as 10 small processes. Moreover, 22 unit works were again drawn by conducting field surveys and interviews. The risk of unit work derived from this study was ergonomically evaluated, and the ergonomic analysis revealed that uploading and transportation were the most dangerous. The results of this study could be used as basic data for preventing industrial accidents among courier workers, whose work has increased with the logistics volume and the development of the logistics industry.

Evaluation of Image Quality by Using a Tungsten Edge Block in a Megavoltage (MV) X-ray Imaging (텅스텐 엣지 블록을 이용하여 Megavoltage (MV) 영상의 질 평가)

  • Min, Jung-Whan;Son, Jin-Hyun;Kim, Ki-Won;Lee, Jung-Woo;Son, Soon-Yong;Back, Geum-Mun;Kim, Jung-Min;Kim, Yeon-Rae;Jung, Jae-Yong;Kim, Sang-Young;Lee, Do-Wan;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.23 no.3
    • /
    • pp.154-161
    • /
    • 2012
  • Digital Radiography (DR) has rapidly developed in megavoltage X-ray imaging (MVI). Thus, a very simple and general quality assurance (QA) method is required. The purpose of this study was to evaluate the modulation transfer function (MTF), the noise power spectrum (NPS) and the detective quantum efficiency (DQE) for MVI using general QA method and computed radiography (CR) device. We used tungsten edge block with $19{\times}10{\times}1cm^3$ thickness and 6MV energy. For detector, CR-IP (image plate), CR-IP-lead, the CR-IP-back (lanex TM fast back screen), CR-IP-front (lanex TM fast front screen) were used and pre-sampling MTF was calculated. The MTF of CR-IP-front showed the highest value with 1.10 lp/mm although the CR-IP showed the only 0.70 lp/mm. The best NPS was observed in CR-IP front screen. According to the increase in spatial frequency, our results showed that DQE was approximately 1.0 cycles/mm. The present study demonstrates that the QA method with our home-made edge block can be used to evaluate MTF, NPS and DQE for MVI.

Comparative study on the radiopacity of different resin-based implant cements (레진계 임플란트용 시멘트의 방사선 불투과성에 대한 비교연구)

  • Han, Kyeong-Hwan;Cheon, Ho-Young;Kim, Min-Su;Shin, Sang-Wan;Lee, Jeong-Yol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.2
    • /
    • pp.97-104
    • /
    • 2014
  • This study was aimed to compare the radiopacity of four kinds of currently available resin based implant cements using digital radiography. Materials and Methods: Four resin-based implant cements((Estemp $Implant^{TM}$ (Spident, Incheon, Korea), $Premier^{(R)}$Implant (Premier, Pennsylvania, USA), $Cem-Implant^{TM}$ (B.J.M lab, Or-yehuda, Israel), $InterCem^{TM}$ (SCI-PHARM, California, USA)) and control group (Elite Cement $100^{TM}$ (GC, Tokyo, Japan) ) were mixed and cured according to the manufacturer's instructions on the custom made split-type metal mold. A total of 150 specimens of each cement were prepared and each specimen (purity over 99%) was placed side-by-side with an aluminum step wedge for image taking with Intraoral X-ray unit (Esx, Vatech, Korea) and digital X-ray sensor (EzSensor, Vatech, Korea). For the evaluation of aluminum wedge equivalent thickness (mm Al), ImageJ 1.47 m (Wayne Rasband, National Institutes of Health, USA) and Color inspector 3D ver 2.0 (Interaktive Visualisierung von Farbraumen, Berlin, Germany) programs were used. Result: Among the 5 cements, Elite cement $100^{TM}$ (control group) showed the highest radio-opacity in all thickness. In the experimental group, $InterCem^{TM}$ had the highest radio-opacity followed by $Premier^{(R)}$ Implant $Cement^{TM}$, $Cem-Implant^{TM}$ and Estemp $Implant^{TM}$. In addition, $InterCem^{TM}$ showed radio-opacity that met the ISO No. 4049 standard in all the tested specimen thickness. Cem-Implant on 0.5 mm thickness showed radiopacity that met the ISO No. 4049 standard. Conclusion: Among the implant resin-based cements tested in the study, $Premier^{(R)}$ Implant Cement and Estemp $Implant^{TM}$ did not show appropriate radio-opacity. Only $InterCem^{TM}$ and $Cem-Implant^{TM}$ 0.5 mm specimen had the proper radiopacity and met the experiment standard.

Analysis of Contrast Medium Dilution Rate for changes in Tube Current and SOD, which are Parameters of Lower Limb Angiography Examination (하지 혈관조영검사 시 매개변수인 관전류와 SOD에 변화에 대한 조영제 희석률 분석)

  • Kong, Chang gi;Han, Jae Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.603-612
    • /
    • 2020
  • This study has a purpose to look into the effect of the relationship between the Tube current (mA) and SOD(Source to Object Distance), which is a parameter of lower limb angiography examination, and the dilution rate of the contrast medium concentration (300, 320, 350) on the image. To that end, using 3 mm vessel model water phantom, a vessel model custom made in the size of peripheral vessel diameter, this study measured relationships between change of parameters, such as tube current (mA), SOD and varying concentrations (300, 320, 350) of contrast medium dilution into SNR and CNR values while analyzing the coefficients of variance(cv<10). The software used to measure SNR and CNR values was Image J 1.50i from NIH (National Institutes of Health, USA). MPV (mean pixel value) and SD (standard deviation) were used after verifying numerically the image signal for region of interest (ROI) and background on phantom from the DICOM (digital imaging and communications in medicine) 3.0 file transmitted to PACS. As to contrast medium dilution by the change of tube current, when 146 mA and 102 mA were compared, For both SNR and CNR, the coefficient of variation value was less than 10 until the section of CM: N/S dilution (100% ~ 30% : 70%) but CM: N/S dilution rate (20%: 80% ~ 10% : 90%) the coefficient of variation was 10 or more. As to contrast medium dilution by concentration for SOD change, when SOD's (32.5 cm and 22.5 cm) were compared,For both SNR and CNR, the coefficient of variation value was less than 10 until the section of CM: N/S dilution (100% ~ 30% : 70%) but CM: N/S dilution rate (20%: 80% ~ 10% : 90%) the coefficient of variation was 10 or more. As to contrast medium dilution by concentration for SOD change, when SOD's (32.5 cm and 12.5 cm) were compared,For both SNR and CNR, the coefficient of variation value was less than 10 until the section of CM: N/S dilution (100% ~ 30% : 70%) but CM: N/S dilution rate (20%: 80% ~ 10% : 90%) the coefficient of variation was 10 or more. As a result, set a low tube current value in other tests or procedures including peripheral angiography of the lower extremities in the intervention, and make the table as close as possible to the image receiver, and adjust the contrast agent concentration (300) to CM: N/S dilution (30%: 70%). ) Is suggested as the most efficient way to obtain images with an appropriate concentration while simultaneously reducing the burden on the kidney and the burden on exposure.