• Title/Summary/Keyword: Digital HF

Search Result 58, Processing Time 0.027 seconds

A Study on the Protocol of SSB Wireless Data for Advancing of Fishery Communication (어업통신의 선진화를 위한 SSB무선데이타 프로토콜에 대한 연구)

  • 김정년;조학현
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2004.04a
    • /
    • pp.37-42
    • /
    • 2004
  • The Ministry of Maritime Affairs & Fisheries have plaining the advancing fishery information integrated system for the fishing present condition, marine resource administration and applicability considering. The fishery information communication system is build up to the raw data & process-network-content. The communication system must be small size, low cost and adapted SSB transceiver, that is using fishery shipping. In this paper We present digital data communication network to exchange information for fishery and safety between fishing ship and coast station in cheeper communication fee using SSB in HF band.

  • PDF

The Cut Off Values for Diagnosing Hot flashes by Using Digital Infrared Thermographic Imaging (적외선 체열 촬영을 이용한 안면홍조 진단의 절단값 산정)

  • Jo, Jun-Young;Hwang, Deok-Sang;Lee, Chang-Hoon;Jang, Jun-Bock;Lee, Kyung-Sub;Lee, Jin-Moo
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.26 no.3
    • /
    • pp.85-92
    • /
    • 2013
  • Objectives: The purpose of this study is to find diagnostic points and define the cut off values of hot flashes by using digital infrared thermographic imaging. Methods: Thermographic images of 75 patients with hot flashes (HF, n=35) and non-hot flashes (NHF, n=40) were retrospectively reviewed. We used the temperature difference between Ex-HN3 and CV17, LU4, CV12, CV4 for diagnosing hot flashes. The temperature differences of between two groups were analysed using independent samples t-tests. The cut off values were calculated by received operating characteristic curve analysis. Analyses were undertaken using SPSS version 17.0. and p-value of <0.05 was considered significant. Results: The temperature difference Ex-HN3 and LU4 were the most significantly different between groups (p<0.001). Using receiver operating characteristic curve analysis, the sensitivity, specificity, and area under the curve were 65.7%, 72.5%, 0.729, respectively. The optimum cut off value was defined as $1.00^{\circ}C$. Conclusions: These results suggest that the digital infrared thermographic imaging is a reliable instrument for estimating hot flashes.

A Study on Evaluation of Human Arousal Level using PPG Analysis (PPG(Photoplethysmography)분석을 이용한 각성도 평가에 관한 연구)

  • Kim, Chi-Jung;Whang, Min-Cheol;Kim, Jong-Hwa;Woo, Jin-Cheol;Kim, Yong-Woo;Kim, Ji-Hye
    • Journal of the Ergonomics Society of Korea
    • /
    • v.29 no.1
    • /
    • pp.113-120
    • /
    • 2010
  • This research is to evaluate the arousal level by using cardiovascular response. PPG was used in this study as one of the method of measuring it rather than ECG (Electrocardiography) for the purpose of solving ergonomic problem of sensing. The participants were in the age group of 20 (mean=24, standard deviation=1.25): five men and five women. Each experiment composed with four identical sets. First, a black screen was displayed for 30 second rest. Then, the prepared 6 pair images were randomly presented for 10 second stimulation and for 30 second non-stimulation. PPG was measured on the earlobes of experimenters at 200Hz sampling frequency. PPG amplitude, PPI(Pulse to Pulse Interval), and PRV(Pulse Rate Variability) were analyzed according to arousal level. T-test was performed to compare between the PPG variables of rest and relaxation, rest and arousal, and relaxation and arousal. Relative to the rest state, PPG amplitude decreased in relaxed state and increased in aroused state. Relative to the rest state, PPI decreased in both emotional states. However, more significant decline was observed in aroused state. PRV's LF and HF were used in the form of LF/HF to compare between the relaxed and the aroused state. Therefore, PPG signal showed significant differences between relaxed and aroused state. In conclusion, evaluation of human arousal level used in the PPG analysis demonstrated that PPG has better usability and comforter measurement than ECG and is clearly an alternative method of measuring arousal level.

A Design of Transceiver for Airborne Communication Applying AME Method (AME 방식을 적용한 항공통신용 송, 수신기 설계)

  • Hong, Gyo Young;Yoon, Kyoung Ho;Kim, Yoo Chang;Kim, Won Hoo
    • Journal of Advanced Navigation Technology
    • /
    • v.2 no.1
    • /
    • pp.53-60
    • /
    • 1998
  • This paper describes some design concepts and design parameters of RZ-SSB which allows full carrier insertion into the single side band to overcome the severe fading in aeronautical telecommunication, and it is described in ARINC Spec. in the name of AME(AM Equivalent), and the necessary transmission bandwidth of RZ-SSB is similar to that of a aeronautical telecommunication. As an amplitude limiter manage to remove the amplitude fading without degrading the quality of output signal, the receiver acts like the FM demodulators. Using the digital Signal Processing(DSP) techniques in the design of transceiver systems has become a performance enhancement of the signal quality and reliability, and making use of DSP, it's able to design low cost, compact transceiver and reduce its weight. For avionics systems is able to eliminate the inherent disadvantages in RZ-SSB, the results of experimental tests suggest that the adoption of RZ concepts is suitable for aeronautical telecommunication transceiver systems use in HF band.

  • PDF

Effect of Acupuncture at PC6(Neiguan) and SP4(Gongsun) points on Autonomic Nervous System in Healthy Adults (내관(內關)(PC6).공손(公孫)(SP4) 자침이 정상인의 자율신경계에 미치는 영향 연구)

  • Rheu, Kyoung-Hwan;Im, In-Hwan;Kim, Dong-Hyun;Na, Byong-Jo;Lee, Beom-Jun;Park, Seong-Uk;Ko, Chang-Nam
    • The Journal of Internal Korean Medicine
    • /
    • v.27 no.3
    • /
    • pp.698-705
    • /
    • 2006
  • Objectives : This study was designed to investigate the effect of PC6 and SP4 on autonomic nerve system in healthy adults. Methods : 22 healthy adults were recruited and randomized into the study group or control group. The study group (real acupuncture group) was acupuncturcd on PC6 and SP4. The control group (sham acupuncture group) was acupunctured superficially near PC6 and SP4 but not the exact points. The subjects rested for 10 minutes, and were then acupunctured. After 15 minutes, acupuncture needles were removed and the subjects rested for another 15 minutes. Heart rate variability(HRV) was continuously measured during the study period by FM-150 (digital Holter ECG recorder). Results : In the real acupuncture group. LF(low frequency) significantly decreased during the acupuncture period(p<0.05). LF/HF ratio also had a significant decrease during acupuncture period and the decrease was maintained during the post-treatment period as compared with the pre-treatment period. In the sham acupuncture group. LF significantly increased during the acupuncture period but LF/HF ratio had no significant changes. Conclusions : The results suggest that acupuncture on PC6 and SP4 can increase parasympathetic activity and balance autonomic nervous system.

  • PDF

A Remote Dimming Control for the Electrodeless Lamps Using the 2.4 GHz RF Communications (2.4 GHz 무선통신을 이용한 무전극 형광램프 조광제어)

  • Yeon, Jae-Eul;Cho, Kyu-Min;Kim, Hee-Jun;Lee, Chan-Kil
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1055-1056
    • /
    • 2006
  • This paper presents a remote dimming control method for the electrodeless lamps using 2.4 GHz RF communication. Since the proposed dimming method are implemented with a simplest open loop control using ISM band HF modem and low cost MCUs, and the remote controller has just several functions such as On/Off and duty ratio increasing/decreasing. It can be made with low cost. In this paper, the detailed digital logics of the proposed remote dimming control are described and the experimental results are presented.

  • PDF

Comparative Analysis of the Heart Rate Variability, Body Composition, Digital Infrared Thermal Imaging and Electro Pulse Graph Between Primary Dysmenorrhea Patients and Secondary Dysmenorrhea Patients (원발성 월경통 환자와 속발성 월경통 환자의 심박변이도, 체성분, 적외선 체열 촬영, 맥전도 검사 상 특징 비교 고찰)

  • Lee, Su-Jeong;Ji, Hae-Ri;Hwang, Deok-Sang;Lee, Chang-Hoon;Jang, Jun-Bock;Lee, Jin-Moo
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.32 no.4
    • /
    • pp.25-38
    • /
    • 2019
  • Objectives: The purpose of this study is to analysis differences of heart rate variability (HRV), body composition, digital infrared thermal imaging (DITI), and electro pulse graph by whether there are some causes of dysmenorrhea or not. Methods: We studied 89 patients who took at least one test among HRV, Body composition, DITI, and electro pulse graph visiting Kyung Hee University Hospital at Gangdong from March 1, 2014 to May 7, 2019. Results: There were statistically significant differences in Low frequency (LF), LF norm and High frequency norm (HF norm) of HRV between primary dysmenorrhea patients and secondary dysmenorrhea patients. There were statistically significant differences in Body Mass Index (BMI) and body fat percentage of Body composition between two groups. But both BMI were included in normal range. There were no statistically significant difference in DITI results. And there was significant difference of Estimated circulation resistance (ECR) between two groups. Conclusions: The results suggest that hormone imbalance of secondary dysmenorrhea patients can affect HRV results. And because of high ECR, phlegm pathology can be more considered in secondary dysmenorrhea patients. Further study should be conducted to confirm the results of body composition and DITI differences.

Monte Carlo Simulation-Based Mammographic Anti-Scatter Grids to Evaluate Performance of Digital Mammography Detector (디지털 맘모 디텍터 성능평가를 위한 몬테카를로용 산란선 제거 그리드 작성에 관한 연구)

  • Yeji Kim;Hyejin Jo;Yongsu Yoon
    • Journal of radiological science and technology
    • /
    • v.47 no.1
    • /
    • pp.1-6
    • /
    • 2024
  • In Recent years, there has been a noticeable increase in the global incidence of breast cancer, with approximately 2.3 million cases of female breast cancer reported worldwide in 2020. Numerous studies are currently underway to enhance the accuracy of breast cancer diagnosis through the development of digital mammography detectors. This study aims to create Monte Carlo simulation-based mammographic anti-scatter grids and investigate their utility in evaluating the performance of digital mammography detector. Two types of mammographic anti-scatter grids, MAM-CP and Senographe 600T HF, were created using Monte Carlo simulation software (MCNPX 2.7.0), with grid ratios of 3.7 : 1 and 5 : 1, respectively. The grid physical characteristics (sensitivity, exposure factor, contrast improvement ratio) were calculated based on the KS C IEC60627 in the simulations using two X-ray qualities, RQA-M2 (28 kVp) and MW4 (35 kVp). As the X-ray tube voltage increased from 28 kVp to 35 kVp, sensitivity and exposure factor exhibited a decreasing trend, while contrast improvement ratio demonstrated an increasing trend. With an increase in grid ratio from 3.7 : 1 to 5 : 1, all physical characteristics showed an upward trend. Our results were consistent with a previous study that conducted measurements of physical properties using a real phantom. However, the pattern of change in the contrast improvement ratio with X-ray tube voltage differed from the previous study.

Investigation of a possible lunar lava tube in the north of the Rima Galilaei using the surface range of Kaguya Lunar Radar Sounder (LRS) data (Kaguya Lunar Radar Sounder (LRS) 표면 레인지 데이터를 이용한 Rima Galilaei의 북쪽 달 용암 동굴 후보지 조사)

  • Sun, Changwan;Takao, Kobayashi;Kim, Kyeong Ja;Choi, Young-Jun
    • Korean Journal of Remote Sensing
    • /
    • v.33 no.3
    • /
    • pp.313-324
    • /
    • 2017
  • A lava tube is one of the hot issues of lunar science because it is regarded as a good candidate place for setting a lunar base. Recently much effort has been made to find lunar lava tubes. However, preceding works mainly made use of high-resolution lunar surface image data in conjunction with geomorphological consideration to present some lava tube candidates. Yet, those candidates stay no more than indirect indications. We propose a new data analysis technique of High Frequency (HF) radar observation data to find lunar lava tubes of which location depth is smaller than the range resolution of the radar pulse. Such shallow target echoes cannot be resolved from surface echoes, which presents the different location of the lunar surface compared to that of real lunar surface. The proposed technique instead finds the surface range (distance from LRS to the reflector of the most intense signal) anomaly which occurs as a result of the low range resolution of LRS pulse. We applied this technique to the surface range of Kaguya Lunar Radar Sounder (LRS) data. The surface range was deduced to make LRS surface elevation which was compared with the average surface elevation of Kaguya Digital Terrain Model (DTM). An anomalous discrepancy of the surface elevation was found in the Rima Galilaei area, which suggests the existence of a shallow lava tube.

Effects of Nasal Continuous Positive Airway Pressure Application on Sympathetic Activation : Power Spectrum Analysis of Electrocardiogram in Obstructive Sleep Apnea Syndrome (폐쇄성 수면무호흡증에서 지속적 상기도 양압술 시행이 교감신경계 활성도에 끼치는 영향 : 심전도 스펙트럼 분석)

  • Youn, Tak;Park, Hae-Jeong;Kim, Eui-Joong;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.7 no.1
    • /
    • pp.43-50
    • /
    • 2000
  • Objectives: Obstructive sleep apnea syndrome(OSAS) is known to be associated with the changes of autonomic nervous system (ANS). Nasal continuous positive airway pressure(nCPAP) treatment was found to correct abnormal ANS changes in OSAS but it remains to be further clarified. We aimed to assess the effects of nCPAP on ANS manifested on electrocardiogram, using spectrum analysis in the subjects with OSAS. Methods: Digital polysomnography was performed in 18 patients with OSAS(mean age $43.7{\pm}16.6$ years ; 17 males, 1 female ; mean respiratory disturbance index (RDI) $48.6{\pm}20.9$) for one baseline and another CPAP nights. From each night, 300 continuous beats of ECGs without artifact were chosen from both stage 2 sleep and REM sleep and they were used for power spectrum analysis. We compared between baseline and CPAP nights the heart rate variability including VLF(very low frequency power), LF (low frequency power), HF(high frequency power), R-R means, R-R variance, and LF/HF ratio, using Wilcoxon signed ranks test. Results: In all patients, nCPAP proved to be effective in relieving apneas and snoring. During nCPAP night compared with baseline night, decreases in VLF(p<0.05), LF(p<0.01), and R-R variance(p<0.05) were found in stage 2 sleep, and decreased LF(p<0.05) was found in REM sleep. No significant differences in each sleep stage were found in other variables between the two nights. Conclusion: Our findings suggest that OSAS increases the activity of sympathetic nervous system and nCPAP application effectively decreases the activity. And nCPAP does not appear to influence the parasympathetic nervous activity in OSAS.

  • PDF