• Title/Summary/Keyword: Digital Fabrication

Search Result 363, Processing Time 0.035 seconds

Effect of polymerization method and fabrication method on occlusal vertical dimension and occlusal contacts of complete-arch prosthesis

  • Lima, Ana Paula Barbosa;Vitti, Rafael Pino;Amaral, Marina;Neves, Ana Christina Claro;Concilio, Lais Regiane da Silva
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.2
    • /
    • pp.122-127
    • /
    • 2018
  • PURPOSE. This study evaluated the dimensional stability of a complete-arch prosthesis processed by conventional method in water bath or microwave energy and polymerized by two different curing cycles. MATERIALS AND METHODS. Forty maxillary complete-arch prostheses were randomly divided into four groups (n = 10): MW1 - acrylic resin cured by one microwave cycle; MW2 - acrylic resin cured by two microwave cycles: WB1 - conventional acrylic resin polymerized using one curing cycle in a water bath; WB2 - conventional acrylic resin polymerized using two curing cycles in a water bath. For evaluation of dimensional stability, occlusal vertical dimension (OVD) and area of contact points were measured in two different measurement times: before and after the polymerization method. A digital caliper was used for OVD measurement. Occlusal contact registration strips were used between maxillary and mandibular dentures to measure the contact points. The images were measured using the software IpWin32, and the differences before and after the polymerization methods were calculated. The data were statistically analyzed using the one-way ANOVA and Tukey test (${\alpha}=.05$). RESULTS. The results demonstrated significant statistical differences for OVD between different measurement times for all groups. MW1 presented the highest OVD values, while WB2 had the lowest OVD values (P<.05). No statistical differences were found for area of contact points among the groups (P=.7150). CONCLUSION. The conventional acrylic resin polymerized using two curing cycles in a water bath led to less difference in OVD of complete-arch prosthesis.

자가 치아 이식술에 사용되는 Computer Aided Rapid Prototyping model(CARP model)의 실제 치아에 대한 오차

  • Lee, Seong-Jae;Kim, Ui-Seong;Kim, Gi-Deok;Lee, Seung-Jong
    • The Journal of the Korean dental association
    • /
    • v.44 no.2 s.441
    • /
    • pp.115-122
    • /
    • 2006
  • Objective : The purpose of this study was to evaluate the dimensional errors between real tooth, 3D CT image and CARP model. Materials and Methods : Two maxilla and two mandible block bones with intact teeth were taken from two cadavers. Computed tomography was taken either in dry state and in wet state. After then, all teeth were extracted and the dimensions of the real teeth were measured using a digital caliper at mesio-distal and bucco-lingual width both in crown and cervical portion. 3D CT image was generated using the V-works $4.0^{TM}$ (Cybemed Inc., Seoul, Korea) software. Twelve teeth were randomly selected for CARP model fabrication. All the measurements of 3D Ct images and CARP models were made in the same manner of the real tooth group. Dimensional errors between real tooth, 3D CT image model and CARP model was calculated. Results : 1) Average of absolute error was 0.199 mm between real teeth and 3D CT image model, 0.169 mm between 3D CT image model and CARP model and 0.291 mm between real teeth and CARP model, respectively. 2) Average size of 3D CT image was smaller than real teeth by 0.149 mm and that of CARP model was smalier than 3D CT image model by 0.067mm. Conclusion : Within the scope of this study, CARP model with the 0.291 mm average of absolute eror can aid to enhance the success rate cf autogenous tooth transplantation due to the increased accuracy of recipient bone and donor tooth.

  • PDF

Design and Fabrication of the Ka-Band Receive Module for Millimeter Wave Seeker (밀리미터파 탐색기를 위한 Ka-대역 수신기 모듈의 설계 및 제작)

  • Yang, Seong-Sik;Lim, Ju-Hyun;Song, Sung-Chan
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.49 no.1
    • /
    • pp.78-84
    • /
    • 2012
  • In this paper, we introduced the design technique about a Ka band receive module for millimeter wave seekers. The receiver module consists of a waveguide, circulator and transition for antenna connection, and a limiter and gain control amplifier for receiver protection. This module is comprised of a sum, azimuth and elevation channel for receiving monopules signal, and a SLB channel for the acquisition of jamming signal. In this paper, receiver gain and range of gain control dependent on ADC nonlinear characteristic was analyzed and designed for wide dynamic range receive. In the test result of the fabricated Ka-band receive, the frequency band is 1 GHz, the noise figure is as low as 8.2 dB, the gain is $56{\pm}2dB$, the dynamic range is 135 dB, the gain congtrol is more than 86 dB, the channel isolation is more than 35 dB.

Formation of Silicon Diaphragm Using Silicon-wafer Direct Bonding / Electrochemical Etch-stopping and Its Application to Silicon Pressure Sensor Fabrication (실리콘 직접 접합 / 전기화학적 식각정지를 이용한 실리콘 다이아프램의 형성과 실리콘 압력센서 제조에의 응용)

  • Ju, B.K.;Ha, B.J.;Kim, K.S.;Song, M.H.;Kim, S.H.;Kim, C.J.;Tchah, K.H.;Oh, M.H.
    • Journal of Sensor Science and Technology
    • /
    • v.3 no.3
    • /
    • pp.45-53
    • /
    • 1994
  • A new type of Si diaphragm was fabricated using Si-wafer direct bonding and two-step electrochemical etch-stopping methods. Using the new diaphragm structure in mechanical sensors, more precise control of cavity depth and diaphragm thickness was achievable. Also, the propagation of the stress, which was generated near the bonding interface, to the surface can be avoided. Finally, a piezoresistive-type Si pressure sensor was fabricated utilizing the diaphragm and a digital pressure gauge, which can display units of pressure, was realized.

  • PDF

The Evaluation and Fabrication of Radiation Phosphor Screen for Non-destructive Testing using the Special Room Temperature Gel-printing Method (상온 겔프린팅 기법을 이용한 비파괴 검사용 방사선 증감지 제작 및 평가)

  • Lee, Jun Haeng
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.391-396
    • /
    • 2020
  • In this study, we developed a phosphor film screen that can be applied to radiographs during non-destructive testing using Gd2O2S:Tb phosphor compounds. The image uniformity of the fabricated phosphor screen film was analyzed by FE-SEM, RMS and RDS analysis. In addition, the tensile strength, elongation, and modulus of elasticity of the Gd2O2S:Tb phosphor screen were evaluated by measuring the stress-strain characteristic curve. As a result, it was evaluated that the RSD value had an excellent image uniformity within 10% of the evaluation criteria. In addition, as a result of evaluation of physical properties, the tensile strength was 1.1760 N/㎟, the tensile strength at break was 1.1515 N/㎟. These results suggest that the Gd2O2S:Tb phosphor screen fabricated using the room temperature gel-printing method could be applied to digital radiography detectors for radiography.

Sensitivity Optimization of MEMS Gyroscope for Magnet-gyro Guidance System (자기-자이로 유도 장치를 위한 MEMS형 자이로의 민감도 최적화)

  • Lee, Inseong;Kim, Jaeyong;Jung, Eunkook;Jung, Kyunghoon;Kim, Jungmin;Kim, Sungshin
    • The Journal of Korea Robotics Society
    • /
    • v.8 no.1
    • /
    • pp.29-36
    • /
    • 2013
  • This paper presents a sensitivity optimization of a MEMS (microelectromechanical systems) gyroscope for a magnet-gyro system. The magnet-gyro system, which is a guidance system for a AGV (automatic or automated guided vehicle), uses a magnet positioning system and a yaw gyroscope. The magnet positioning system measures magnetism of a cylindrical magnet embedded on the floor, and AGV is guided by the motion direction angle calculated with the measured magnetism. If the magnet positioning system does not measure the magnetism, the AGV is guided by using angular velocity measured with the gyroscope. The gyroscope used for the magnet-gyro system is usually MEMS type. Because the MEMS gyroscope is made from the process technology in semiconductor device fabrication, it has small size, low-power and low price. However, the MEMS gyroscope has drift phenomenon caused by noise and calculation error. Precision ADC (analog to digital converter) and accurate sensitivity are needed to minimize the drift phenomenon. Therefore, this paper proposes the method of the sensitivity optimization of the MEMS gyroscope using DEAS (dynamic encoding algorithm for searches). For experiment, we used the AGV mounted with a laser navigation system which is able to measure accurate position of the AGV and compared result by the sensitivity value calculated by the proposed method with result by the sensitivity in specification of the MEMS gyroscope. In experimental results, we verified that the sensitivity value through the proposed method can calculate more accurate motion direction angle of the AGV.

Bandwidth Prediction for the Rectangular Planar Monopole Antenna by Radiation Mode Identification (복사 모드 해석에 의한 사각형 평면 모노폴 안테나의 대역폭 예측)

  • Chun, Joong-Chang;Shim, Jae-Ruen;Kim, Tae-Soo
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.8 no.1
    • /
    • pp.70-74
    • /
    • 2015
  • In this paper, we have illuminated the radiation modes of rectangular planar antennas to interpret the nature of the wideband characteristic upon which formulas for bandwidth prediction are presented. Rectangular planar antennas are being investigated by many researchers in virtue of relatively simple design and fabrication procedures to replace the cylindrical monopoles. But the design principle for rectangular planar antennas is still based on that of cylindrical monopoles, and the nature of the wideband characteristic and the formula to estimate the upper band frequency are not analyzed yet. In this research, we have shown the patterns of the radiation modes explaining the wideband characteristic and also proposed the upper band frequency with minor modification for the lower band frequency formula based on mode formation principles. Finally we have confirmed the validity of our results, within 10 % accuracy, by the application to some published results.

Fabrication of EEG Measuring System with High Precision Characteristics (고정밀도의 뇌파측정시스템 개발 연구)

  • 도영수;장호경;한병국
    • Progress in Medical Physics
    • /
    • v.13 no.3
    • /
    • pp.156-162
    • /
    • 2002
  • In this study, we attempted in preparing high precision EEG measuring equipment. To measure EEG in high efficiency, pre-amplifier should get high performance common mode rejection ratio. Also, separation amplifier is essential to eliminate common line noise. So, our study were pointed at elevating the efficiency of eliminating noise, user safety and low noise characteristics. Prepared high precision pre-amplifier for EEG was A/D converted to automatically classify $\alpha$ wave, $\beta$ wave and $\theta$ wave. And converted data were Fast Fourier Transformed with real time DSP (Digital Signal Processing). Clinical demonstrations were carried out with healthy students, aged between 20 to 26 who has no histories of illness. To recognize the efficiency of the EEG, prepared EEG were used with MS equipment in low stimulated state and high stimulated state. Then, we studied at the effect of sensitivity on brain wave. From this study, it is known that our EEG equipment is efficient in sensitivity evaluation and suitable stimulations for each psychological state are required.

  • PDF

Fabrication and Characterization of Polycrystalline Mereuric Iodide Films using Particle-in-Binder Methods (Particle-in-Binder(PIB) 법을 이용한 다결정 $HgI_2$ 필름 제작 및 특성 연구)

  • Cha, Byung-Youl;Cho, Sung-Ho;Kim, So-Yeong;Woon, Min-Seuk;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.330-330
    • /
    • 2007
  • Polycrystalline mercuric iodide $HgI_2$) films are being developed as a new detector technology for digital x-ray imaging. The $HgI_2$ is generally vacuum deposited by physical vapor deposition (PVD) process. But the PVD thick deposition has been caused any instability in the biasing due to any defects or cracks. In this work we present a new particle-in-binder (PIB) methodologies used for the $HgI_2$ thick films. These growth techniques can be easily extended to produce much larger film areas. This paper, for the first time, presents results and comparison of polycrystalline $HgI_2$ films derived by various PIB methods. We investigated the structural and morphological properties of the films using X-ray diffraction (XRD) and scanning electron microscopy (SEM) analysis. The films were characterized with respect to their electrical properties and in response to x-ray photons. Physical and electrical results were also compared between conventional polycrystalline PVD and our detectors. Leakage current as low as $350\;pA/cm^2$ at the bias voltage of ~ 200 V has been observed. And high sensitivity and good linearity in the response to x-rays was obtained in the film derived by PIB sedimentation method. Our future efforts will concentrate on optimization of film growth techniques for uniform large area deposition on image readout arrays.

  • PDF

The Multi-layer Fabrication and Characteristic Performance for Dark Current Reduction of Mercury Iodide (Hgl2의 누설전류 저감을 위한 다층구조 제작 및 특성 평가)

  • Kim, Kyung-Jin;Park, Ji-Koon;Kang, Sang-Sik;Cha, Byung-Youl;Cho, Sung-Ho;Kim, Jin-Yung;Mun, Chi-Ung;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.388-389
    • /
    • 2005
  • In this paper, the electric properties of mercury Iodide multi-layer samples has been investigated. We measured and analyzed their performance parameters such as the X-ray sensitivity and dark-current for a mercury Iodide multi-layer X-ray detector with a dielectric layer. The digital X-ray image detector can be constructed by integrating photoconduction multi-layer that dielectric layer has characteristics of low dark-current, high X-ray sensitivity. However this process has found to have complexity on the performance of the sample. We have investigate dielectric layer that it substitute dielectric layer for HgO(Mercury Oxide). We have employed two approaches for producing the mercury Iodide sample : 1) Physical Vapor Deposition(PVD) and 2) Particle-In-Binder(PIB). In this paper fabricated by PIB Method with thicknesses ranging from approximately 180um to 240um and we could produce high-quality samples for each technique particular application. As results, the dielectric materials such as HgO between the dielectric layer and the top electrode may reduce the dark-current of the samples. Mercury Iodide multi-layer having HgO has characteristics of low dark-current, high X-ray sensitivity and simple processing. So we can acquired a enhanced signal to noise ratio. In this paper offer the method can reduce the dark-current in the X-ray detector.

  • PDF