• 제목/요약/키워드: Digital Dilution

Search Result 22, Processing Time 0.02 seconds

Characteristics of Fuel Mixing and Evaporation Based on Impingement Plate Shape in a Denitrification NOx System with a Secondary Injection Unit (2차 분사시스템을 갖는 De-NOx 시스템의 충돌판 형상에 따른 연료의 혼합 및 증발 특성 향상을 위한 연구)

  • Park, Sangki;Oh, Jungmo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.7
    • /
    • pp.884-891
    • /
    • 2016
  • A secondary injection system in a diesel engine has benefits: it can be controlled independently without interrupting engine control, it can be adapted to various layouts for exhaust systems, and it pose no reductant dilution problems compared to post injection systems in the combustion chamber or other supplemental reductant injections. In a secondary injection system, the efficiency of the catalyst depends on the method of reducing the supply. The reductant needs to be maintained and optimized with constant pressure, the positions and angles of injector is a very important factor. The concentration and amount of reductant can be changed by adjusting secondary injection conditions. However, secondary injection is highly dependent upon the type of injector, injection pressure, atomization, spray technology, etc. Therefore, it is necessary to establish injection conditions the spray characteristics must be well-understood, such as spray penetration, sauter mean diameter, spray angle, injection quantity, etc. Uniform distribution of the reductant corresponding to the maximum NOx reduction in the DeNOx catalyst system must also assured. With this goal in mind, the spray characteristics and impingement plate types of a secondary injector were analyzed using visualization and digital image processing techniques.

Evaluation of Usefulness and Procedures for Safety of Radiopharmaceuticals in Cisternography (Cisternography 검사 시 사용되는 방사성의약품의 안정성 확보를 위한 검사도입 및 유용성 평가)

  • Kim, Da-Eun;Yoo, Yeon-Wook;Choi, Ho-Yong;Kim, Yun-Cheol;Kim, Yeong-Seok;Won, Woo-Jae;Kim, Seok-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.45-49
    • /
    • 2010
  • Purpose: Several radiopharmaceuticals were used for cisternography. But recently, due to more short acquisition time, high resolution than other radiopharmaceuticals like In-111 DTPA, we were using Tc-99m DTPA in cisternography. Using of Tc-99m DTPA for intrathecal, was not officially recognised by the FDA. And there are matters of aseptic meningitis, muscular tetany, seizures by inappropriate radiopharmaceuticals handling. So, it is necessary to prevent adverse reactions while handling the radiopharmaceuticals using in cisternography. Therefore, this study aims to evaluation of usefulness and procedures for safety of radiopharmaceuticals in cisternography. Materials and Methods: Subjects were 12radioactive tracer vials using in cisternography in 2008 Dec. 16 - 2009 Dec. 30. (1) Radioactive tracer Vial test - We were measured NaPertechnetate radiation dose and volume, normal saline volume for dilution, source volume and dose activity for patient injection. And then, calculated mass of pure DTPA. (2) Bacterial endotoxin test - We performed pyrogen test using by negative/positive control vials which was added normal saline 0.2 mL and added normal saline 0.1 mL, Tc-99m DTPA 0.1 mL in test control vial. And then, reacted by digital hot plate in $37.5^{\circ}C$ for 1 hour and compared of gel-clot in each control vials. (3) Compliance safety procedure - We were checked safety issues and wrote out a safety procedure exam sheet. Results: (1) Radioactive tracer Vial test - Mass of DTPA per dose for patient injection (mg) was 0.88 (mg) on average, and Mass of DTPA per volume for patient injection (mg) was 0.74 (mg) on average. (2) Bacterial endotoxin test - All control test vials showed negative reactions. (3) Compliance safety procedure - We were checked safety issues and wrote out a safety exam sheet in all the exams. So, there were no adverse reactions. Conclusion: We could examine easier to safety tests using by Techscan - DTPA (Mallinckrodt): CaNa3. Each test results were passed the safety tests and there are no adverse reactions. The use of Tc-99m DTPA for cisternography, always has been become an issue. Since it has occur adverse reaction while examine the cisternography using by Tc-99m DTPA, it needs to set up the 'Standard Operating procedures'.

  • PDF