• Title/Summary/Keyword: Digital Detector

Search Result 554, Processing Time 0.026 seconds

Preliminary Results of Thermal Effects due to Mobile Phones

  • Sik, Yoo-Done
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.471-473
    • /
    • 2002
  • Public concerns associated with the electromagnetic field (EMF) exposures from mobile phones on human body are increased. Although studies on the effects of the EMF exposures on human have been carried out for a long time, it is not proved yet whether the EMF effect is harmful or not. Based on the scientific results by experts, EMF exposure limits have been regulated as a precautionary approach on the assumption that the EMF effect may be harmful. It is well known that absorbed EMF can be transformed into heat within biological tissues and that thermal effects are related with the specific absorption rate (SAR) distribution. However, the relative magnitude and distribution of the energies are not well defined. Although there is comprehensive information of the thermal effects, most of them come from animal and in vitro studies. Considerable efforts have been made to analyze the EMF absorption model while the actual temperature in the human body has been rarely measured. Temperature changes on the face of a healthy male volunteer were studied. A digital mobile phone of 1.8GHz was used. A digital infrared imaging system (IRIS-5000, Medicore, Seoul, Korea) was applied to take infrared pictures of the face every minute while the volunteer talked over the mobile phone for 20 minutes. The specification of the imaging system was as follows: Temperature resolution = 0.1$^{\circ}C$; Range of temperature measurement = 17~40$^{\circ}C$; Pixel size = 0.9mm ${\times}$ 0.9mm; Frame time = 2.6s; Active temperature of detector = 77$^{\circ}$K. The result showed that temperature of the ear region was increased during the phone call and the region of the temperature increase on the face was expanded as the phone call time increased. Further study is necessary to investigate the temperature rise analytically and quantitatively.

  • PDF

A High-Speed Synchronization Method Robust to the Effect of Initial SFO in DRM Systems (DRM 시스템에서 초기 샘플링 주파수 옵셋의 영향에 강인한 고속 동기화 방식)

  • Kwon, Ki-Won;Cho, Yong-Soo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.1A
    • /
    • pp.73-81
    • /
    • 2012
  • In this paper, we propose a high-speed synchronization method for Digital Radio Mondiale (DRM) receivers. In order to satisfy the high-speed synchronization requirement of DRM receivers, the proposed method eliminate the initial sampling frequency synchronization process in conventional synchronization methods. In the proposed method, sampling frequency tracking is performed after integer frequency synchronization and frame synchronization. Different correlation algorithms are applied to detect the first frame of the Orthogonal Frequency Division Multiplexing (OFDM) demodulation symbol with sampling frequency offset (SFO). A frame detection algorithm that is robust to SFO is selected based on the performance analysis and simulation. Simulation results show that the proposed method reduces the time spent for initial sampling frequency synchronization even if SFO is present in the DRM signal. In addition, it is verify that inter-cell differential correlation used between reference cells is roubst to the effect of initial SFO.

Evaluation of Static Error Signal for Super Slim Optical Pick-up (초소형 광 픽업의 정적 오차 신호 검출)

  • Kang, S.M.;Cho, E.H.;Sohn, J.S.;Kim, W.C.;Park, N.C.;Park, Y.P.
    • Transactions of the Society of Information Storage Systems
    • /
    • v.1 no.2
    • /
    • pp.115-120
    • /
    • 2005
  • As a popularity of a portable digital device such as a cellular phone, a digital camera and a MP3 player is spreading, the demand of the mobile storage device increases rapidly. A bluray technology using 405nm laser diode and objective lens having high NA(Numerical Aperture), 0.85, satisfies a miniaturization and a high capacity which are the requirements of the portable device. To develop SFFOP(small form factor optical pickup), it is prerequisite to minimize the number of optical components and establish evaluation and assembly method of micro optical pickup system as well as mass production method of micro optical component. To minimize optical elements of optical pickup, there have been many researches to use P-HOE(Polarized Holographic Optical Element) due to its extremely small size and versatile function. However, P-HOE is handled and assembled very accurately in SFFOP. In this paper, static error signal detection method is developed for an alignment of P-HOE in SFFOP. Using developed static error signal detection method, P-HOE can be aligned very accurately with real time result of static error signals of pickup such as FES(focusing error signal) and TES(Tracking Error Signal). The developed static error signal detection method is verified by the evaluation of commercialized DVD Pickup. And finally. developed static error signal detection method is applied for the assembly of P-HOE in SFFOP system satisfies specification of BD(Blu-ray Disk).

  • PDF

A Facial Morphing Method Using Delaunay Triangle of Facial Landmarks (얼굴 랜드마크의 들로네 삼각망을 이용한 얼굴 모핑 기법)

  • Park, Kyung Nam
    • Journal of Digital Contents Society
    • /
    • v.19 no.1
    • /
    • pp.213-220
    • /
    • 2018
  • Face morphing, one of the most powerful image processing techniques that are often used in image processing and computer graphic fields, as it is a technique to change the image progressively and naturally from the original image to the target image. In this paper, we propose a method to generate Delaunay triangles using the facial landmark vertices generated by the Dlib face landmark detector and to implement morphing through warping and cross dissolving of Delaunay triangles between the original image and the target image. In this paper, we generate vertex points for face not manually but automatically, which is the major feature of the face such as eye, eyebrow, nose, and mouth, and is used to generate Delaunay triangles automatically which is the main characteristic of our face morphing method. Simulations show that we can add vertices manually and get more natural morphing results.

Real-Time Landmark Detection using Fast Fourier Transform in Surveillance (서베일런스에서 고속 푸리에 변환을 이용한 실시간 특징점 검출)

  • Kang, Sung-Kwan;Park, Yang-Jae;Chung, Kyung-Yong;Rim, Kee-Wook;Lee, Jung-Hyun
    • Journal of Digital Convergence
    • /
    • v.10 no.7
    • /
    • pp.123-128
    • /
    • 2012
  • In this paper, we propose a landmark-detection system of object for more accurate object recognition. The landmark-detection system of object becomes divided into a learning stage and a detection stage. A learning stage is created an interest-region model to set up a search region of each landmark as pre-information necessary for a detection stage and is created a detector by each landmark to detect a landmark in a search region. A detection stage sets up a search region of each landmark in an input image with an interest-region model created in the learning stage. The proposed system uses Fast Fourier Transform to detect landmark, because the landmark-detection is fast. In addition, the system fails to track objects less likely. After we developed the proposed method was applied to environment video. As a result, the system that you want to track objects moving at an irregular rate, even if it was found that stable tracking. The experimental results show that the proposed approach can achieve superior performance using various data sets to previously methods.

A Built-in Self-Test of Static Parameters for Analog-to-Digital Converters (아날로그-디지털 변환기의 정적 파라미터 테스트를 위한 내장 자체 테스트 방법)

  • Kim, In-Cheol;Jang, Jae-Won;Kang, Sung-Ho
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.49 no.5
    • /
    • pp.30-36
    • /
    • 2012
  • A new BIST(Built-In Self-Test) scheme to test ADC(Analog-to-Digital Converter) with a transition detector is proposed. The proposed BIST is able to replaces histogram method, the most popular approach in static testing of ADC. With a ramp signal as an input test stimulus, the proposed BIST calculates ADC's static parameters such as offset, gain, INL(Integral Non-Linearity) and DNL(Differential Non-Linearity). The three detectors in the proposed BIST can deal with a transient zone problem, a phenomenon due to random noise in real test environments and are cost efficient at various acceptable ranges determined as a test spec. The simulation results validate that our method performs accurate static test and show the reduction of the hardware overhead.

A real-time sorting algorithm for in-beam PET of heavy-ion cancer therapy device

  • Ke, Lingyun;Yan, Junwei;Chen, Jinda;Wang, Changxin;Zhang, Xiuling;Du, Chengming;Hu, Minchi;Yang, Zuoqiao;Xu, Jiapeng;Qian, Yi;She, Qianshun;Yang, Haibo;Zhao, Hongyun;Pu, Tianlei;Pei, Changxu;Su, Hong;Kong, Jie
    • Nuclear Engineering and Technology
    • /
    • v.53 no.10
    • /
    • pp.3406-3412
    • /
    • 2021
  • A real-time digital time-stamp sorting algorithm used in the In-Beam positron emission tomography (In-Beam PET) is presented. The algorithm is operated in the field programmable gate array (FPGA) and a small amount of registers, MUX and memory cells are used. It is developed for sorting the data of annihilation event from front-end circuits, so as to identify the coincidence events efficiently in a large amount of data. In the In-Beam PET, each annihilation event is detected by the detector array and digitized by the analog to digital converter (ADC) in Data Acquisition Unit (DAQU), with a resolution of 14 bits and sampling rate of 50 MS/s. Test and preliminary operation have been implemented, it can perform a sorting operation under the event count rate up to 1 MHz per channel, and support four channels in total, count rate up to 4 MHz. The performance of this algorithm has been verified by pulse generator and 22Na radiation source, which can sort the events with chaotic order into chronological order completely. The application of this algorithm provides not only an efficient solution for selection of coincidence events, but also a design of electronic circuit with a small-scale structure.

A Study on the Sensor Module System for Real-Time Risk Environment Management (실시간 위험환경 관리를 위한 센서 모듈시스템 연구)

  • Cho, Young Chang;Kwon, Ki Jin;Jeong, Jong Hyeong;Kim, Min Soo
    • Journal of IKEEE
    • /
    • v.22 no.4
    • /
    • pp.953-958
    • /
    • 2018
  • In this study, a portable detection system was developed that can detect harmful gas and signals simultaneously in an enclosed space of industrial sites and underground facilities. The developed system is a sensor module for gas detection, a patch type 1 channel small ECG sensor, a module for three-axial acceleration detection sensor, and a system for statistics. In order to verify the performance of the system modules, the digital resolution, signal frequency, output voltage, and ultra-small modules were evaluated. As a result of the performance of the developed system, the digital resolution was 300 (rps) and the signal amplification gain was 500 dB or more, and the ECG module was manufactured with $50mm{\times}10mm{\times}10mm$ to increase patch utilization. It is believed that the product of this research will be valuable if it is used as an IoT-based management system for real-time monitoring of industrial workers.

A Study on the Scatter X-ray Signal and Noise Characteristics of Indirect Conversion-Type Detector for Radiography (산란선이 간접변환방식 엑스선 검출기의 신호 및 노이즈 특성에 미치는 영향에 관한 연구)

  • Kim, Junwoo
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.3
    • /
    • pp.345-353
    • /
    • 2021
  • Digital radiography imaging systems can also help diagnose lesions in patients, but if x-rays that enter the human body cause scatter x-ray due to interaction with substances, they affect the signal and noise characteristics of digital x-ray images. To regard the human body as polymethyl methacrylate (PMMA) and observe the properties of scattered x-ray generated from PMMA on x-ray images, we analyze signal and noise in the spatial domain as well as noise-power spectrum (NPS), and detective quantum efficiency (DQE) at zero frequency. As PMMA thickness increased, signals decreased, the noise increased, and NPS degradation was identified in overall spatial frequencies. Based on these characteristics, zero-frequency performance was also shown to be degraded. Comparative analysis with Monte-carlo simulations will need to be made to analyze the zero-frequency performance by scattered x-ray of indirect conversion-type x-ray detectors more quantitatively.

Evaluation of Image Quality for Diagnostic Digital Chest Image Using Ion Chamber in the Total Mastectomy (변형근치유방절제술 환자의 Ion chamber 변화에 따른 디지털 흉부 영상의 화질 평가)

  • Lee, Jin-Soo;Ko, Seong-Jin;Kang, Se-Sik;Kim, Jung-Hoon;Park, Hyong-Hu;Kim, Donghyun;Kim, Changsoo
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.3
    • /
    • pp.204-210
    • /
    • 2013
  • The patients who had been operated total mastectomy are different from general women in their breasts thickness due to breast surgery. As a result, digital chest image from total mastectomy patients will be different attenuation. The main objective for this study is to show that a proper Ion chamber standard combination measuring MTF which is objective basis for Digital image, when be x-ray for total mastectomy patient. We have designed the unique number that shown Left is 1, Right is 2, Center is 3 and have put the edge phantom on detector ion chamber. Lastly, we have obtained experiment images. The evaluations of all image quality have measured by 50% MTF of spatial resolution and absorption dose using Matlab(R2007a). The result showed that average exposure condition, MTF value, absorption dose for 1+3 and 2+3 combinations were 2.745 mAs, 1.925 lp/mm, 0.688 mGy. Consequently, that showed high MTF, DQE and low dose than other combinations. Therefore, a proper changes of ion chambers are able to improve image quality and to reduce radiation exposure when be X-ray for total mastectomy patients. Also, it will be possible to standard for application chamber combination and utilization on clinical detection.