• 제목/요약/키워드: Digital Dentistry

검색결과 839건 처리시간 0.028초

Evaluating Measurements: A Comparative Study of Digital and Plaster Models for Orthodontic Applications in Mixed Dentition

  • Seo Young Shin;Yong Kwon Chae;Ko Eun Lee;Mi Sun Kim;Ok Hyung Nam;Hyo-seol Lee;Sung Chul Choi
    • 대한소아치과학회지
    • /
    • 제51권1호
    • /
    • pp.55-65
    • /
    • 2024
  • This study aimed to assess the accuracy of tooth widths, intermolar widths, and arch lengths acquired through two intraoral scanners, including iTero Element Plus Series (Align Technology, Santa Clara, CA, USA) and Trios 4 (3Shape, Copenhagen, Denmark), specifically on mixed dentition. A total of 30 subjects were divided into 2 groups, each undergoing both alginate impressions and intraoral scanning using either the iTero or Trios scanner. The plaster models were measured with a caliper, while the digital models were measured virtually. In the iTero group, all tooth width measurements exhibited differences compared to the plaster values, except for maxillary left lateral incisors (p = 0.179), mandibular right (p = 0.285), and left (p = 0.073) central incisors. The Trios group did not display significant differences in any of the tooth width measurements. Intermolar width comparisons for both groups indicated differences, except for mandibular primary canine to primary canine values (p = 0.426) in the iTero group. Regarding arch length, the mandibular anterior, maxillary right, and left arch lengths in the iTero group demonstrated larger caliper values than those of iTero. Conversely, in the Trios group, all parameters showed smaller caliper values, especially in upper anterior, maxillary right, mandibular right, and mandibular left arch lengths with significance (p = 0.027, 0.007, 0.003, and 0.047, respectively). Despite the differences between the two groups, digital models might be clinically suitable alternatives for plaster models. Pediatric dentists should carefully assess these differences, as a comprehensive evaluation would result in precise orthodontic treatment planning and favorable outcomes for young patients with mixed dentition.

치과 디지털 활용에 관한 치과위생사의 인식 (Perceptions of dental hygienists toward digital dentistry)

  • 김영선;박현숙;구인영
    • 한국치위생학회지
    • /
    • 제13권6호
    • /
    • pp.909-916
    • /
    • 2013
  • Objectives : The purpose of this study was to investigate the perceptions of dental hygienists toward digital dentistry. Methods : The subjects were 393 dental hygienists in Daegu Gyeongbuk. A total of 380 data were analyzed except the incomplete questionnaires. Data were analyzed by descriptive statistics, chi-square test, t-test, one-way ANOVA using SPSS version 18.0. Results : 1. Difference of perception by general characteristics was affected by age, academic background, working career, and married. 2. Difference of perception by utilization of digital facilities was affected by digital camera, CAD/CAM system, oral scanner, and computer system. 3. Difference of perception by digital education experience and intention of participation was affected by stronger intention to participate in digital education and practical exercise. Digital X-ray system and CAD/CAM system were the must-be equipment in education. Conclusions : Utilization of digital dentistry is the motive for education experience in dental hygienists.

Effect of scanning strategies on the accuracy of digital intraoral scanners: a meta-analysis of in vitro studies

  • Louis Hardan;Rim Bourgi;Monika Lukomska-Szymanska;Juan Carlos Hernandez-Cabanillas;Juan Eliezer Zamarripa-Calderon;Gilbert Jorquera;Sinan Ghishan;Carlos Enrique Cuevas-Suarez
    • The Journal of Advanced Prosthodontics
    • /
    • 제15권6호
    • /
    • pp.315-332
    • /
    • 2023
  • PURPOSE. This study aimed to investigate whether the accuracy of intraoral scanners is influenced by different scanning strategies in an in vitro setting, through a systematic review and meta-analysis. MATERIALS AND METHODS. This review was conducted in accordance with the PRISMA 2020 standard. The following PICOS approach was used: population, tooth impressions; intervention, the use of intraoral scanners with scanning strategies different from the manufacturer's instructions; control, the use of intraoral scanners following the manufacturers' requirements; outcome, accuracy of intraoral scanners; type of studies, in vitro. A comprehensive literature search was conducted across various databases including Embase, SciELO, PubMed, Scopus, and Web of Science. The inclusion criteria were based on in vitro studies that reported the accuracy of digital impressions using intraoral scanners. Analysis was performed using Review Manager software (version 5.3.5; Cochrane Collaboration, Copenhagen, Denmark). Global comparisons were made using a standardized mean difference based on random-effect models, with a significance level of α = 0.05. RESULTS. The meta-analysis included 15 articles. Digital impression accuracy significantly improved under dry conditions (P < 0.001). Moreover, trueness and precision were enhanced when artificial landmarks were used (P ≤ 0.02) and when an S-shaped pattern was followed (P ≤ 0.01). However, the type of light used did not have a significant impact on the accuracy of the digital intraoral scanners (P ≥ 0.16). CONCLUSION. The accuracy of digital intraoral scanners can be enhanced by employing scanning processes using artificial landmarks and digital impressions under dry conditions.

'Digital Smile Design'을 이용한 심미수복증례 (Esthetic restoration using Digital Smile Design: a case report)

  • 김광현;이규호;배아란;노관태;김형섭
    • 대한치과보철학회지
    • /
    • 제53권2호
    • /
    • pp.144-149
    • /
    • 2015
  • 심미적인 수복물을 제작하기 위해서는 환자의 안모를 고려한 시각화된 정보가 필요하다. 기준 수평, 수직선 같은 정보와 환자의 요구사항에 대한 소통 없이 제작된 수복물은 비심미적인 결과를 초래할 수 밖에 없다. 따라서 어떻게 이러한 정보를 전달하느냐가 심미적인 수복물을 제작할 수 있는 성공의 요건이 될 것이다. 디지털 진단도구인 'Digital Smile Design (DSD)' 을 이용하여 심미수복에 필요한 정보를 시각화하고 수복물을 설계하여 심미적인 결과를 도출해내는 일련의 과정을 보고하고자 한다.

Validation of three-dimensional digital model superimpositions based on palatal structures in patients with maximum anterior tooth retraction following premolar extraction

  • Liu, Jing;Koh, Kyong-Min;Choi, Sung-Hwan;Kim, Ji-Hoi;Cha, Jung-Yul
    • 대한치과교정학회지
    • /
    • 제52권4호
    • /
    • pp.258-267
    • /
    • 2022
  • Objective: This study aimed to evaluate the superimposition accuracy of digital modes for measuring tooth movement in patients requiring anterior retraction after premolar extraction based on the proposed reference regions. Methods: Forty patients treated with bilateral maxillary first premolar extraction were divided into two groups: moderate retraction (< 7.0 mm) and maximum retraction (≥ 7.0 mm). Central incisor displacement was measured using cephalometric superimpositions and three-dimensional (3D) digital superimpositions with the 3rd or 4th ruga as the reference point. The Wilcoxon signed-rank test and linear regression analyses were performed to test the significance of the differences and relationships between the two measurement techniques. Results: In the moderate retraction group, the central incisor anteroposterior displacement values did not differ significantly between 3D digital and cephalometric superimpositions. However, in the maximum-retraction group, significant differences were observed between the anteroposterior displacement evaluated by the 3rd ruga superimposition and cephalometric methods (p < 0.05). Conclusions: This study demonstrated that 3D digital superimpositions were clinically as reliable as cephalometric superimpositions in assessing tooth movements in patients requiring moderate retraction. However, the reference point should be carefully examined in patients who require maximum retraction.

총의치 제작에 적용 가능한 디지털 기술과 임상적 고찰 (Application and consideration of digital technology for removable complete denture)

  • 이정진;송광엽;박주미
    • 대한치과의사협회지
    • /
    • 제57권9호
    • /
    • pp.534-543
    • /
    • 2019
  • Digital technology has changed various aspects of the clinical dentistry. The intraoral scanner and Computer-aided design / Computer-aided manufacturing (CAD-CAM) technology are widely used in fabricating fixed prostheses and in implant surgery. These technologies greatly improved the efficiency of clinical and laboratory procedures. With all newly introduced software, devices, and clinical studies, digital technology has been actively applied in removable prostheses. It is now possible to fabricate the removable prostheses more quickly and easily through subtractive and additive manufacturing. Various clinical and laboratory protocols were introduced by many manufacturers. The purpose of this review is to summarize the literature on digital technology for fabricating complete denture with current status and future perspectives.

  • PDF

Direct digital radiography versus conventional radiography for estimation of canal length in curved canals

  • Mohtavipour, Seiedeh Tahereh;Dalili, Zahra;Azar, Nasim Gheshlaghi
    • Imaging Science in Dentistry
    • /
    • 제41권1호
    • /
    • pp.7-10
    • /
    • 2011
  • Purpose : The purpose of this study was to compare the conventional and digital radiography in the estimation of working length in mandibular molars. Materials and Methods : Sixty molar teeth were selected and divided into three groups in the basis of canal curves (0-$15^{\circ}$, 15-$30^{\circ}$, > $30^{\circ}$). After the placement of a 15 K-file, radiographs were taken with a conventional film (Fspeed) and a digital sensor. Canal lengths were measured in these images by two observers. Statistical analysis was performed with repeated measures of ANOVA and paired sample t-test with 95% confidence. Results : There was a high inter-observer agreement on the measurements of working length in conventional and digital radiographs. There was no significant difference between the mean values of measurements in conventional and digital radiography. Moreover, there was no significant difference between conventional and digital radiography with the actual values in the basis of canal curves. Conclusion : The accuracy of conventional and digital radiography in the determination of the working length was in an acceptable range.

디지털영상을 이용한 치근이개부 실험병소의 판독능에 관한 연구 (An experimental study on the readability of digital images in the furcal bone defects)

  • 강형욱;황의환;이상래
    • Imaging Science in Dentistry
    • /
    • 제33권2호
    • /
    • pp.71-77
    • /
    • 2003
  • Purpose : To evaluate and compare the efficacy of digital radiographic images in the detection of bone loss at the bifurcation area of the mandibular first molar with traditional film-based periapical radiographs, Materials and Methods : One dried human mandible with minimal periodontal bone loss around the first molar was selected and an artificial alveolar bone defect at the bifurcation area was serially prepared over 18 steps. Images were taken using a direct CCD-based system and with F-speed periapical films. The images were evaluated by seven interpreters (3 radiologists, 3 periodontologists, and 1 general dentist) using a 5-point confidence rating scale. Results : The readability of both periapical radiographs and digital image increased as the size of the artificial lesion and exposure time increased (p < 0.05). Periapical radiographs offered greater readability of smaller bone defects than digital images, and the coefficient of variation of mean score between periapical radiographs and digital images showed a significant difference. Conclusion : The experimental results indicate that a significant difference in the coefficient of variation of mean score exists between periapical radiographs and digital images, and that traditional film-based periapical images offer greater readability of smaller bone defects than digital images can presently offer.

  • PDF

Clinical Validity of Tooth Size Measurements Obtained via Digital Methods with Intraoral Scanning

  • Mohammed, Alnefaie;Sun-Hyung, Park;Jung-Yul, Cha;Sung-Hwan, Choi
    • Journal of Korean Dental Science
    • /
    • 제15권2호
    • /
    • pp.132-140
    • /
    • 2022
  • Purpose: Dental diagnostic records derived from study models are a popular method of obtaining reliable and vital information. Conventional plaster models are the most common method, however, they are being gradually replaced by digital impressions as technology advances. Moreover, three-dimensional dental models are becoming increasingly common in dental offices, and various methods are available for obtaining them. This study aimed to evaluate the accuracy of the measurement of dental digital models by comparing them with conventional plaster and to determine their clinical validity. Materials and Methods: The study was conducted on 16 patients' maxillary and mandibular dental models. Tooth size (TS), intercanine width (ICW), intermolar width (IMW), and Bolton analysis were taken by using a digital caliper on a plaster model obtained from each patient, while intraoral scans were manually measured using two digital analysis software. A one-way analysis of variance test was used to compare the dental measurements of the three methods. Result: No significant differences were reported between the TS, the ICW and IMW, and the Bolton analysis through the conventional and two digital groups. Conclusion: Measurements of TS, arch width, and Bolton analysis produced from digital models have shown acceptable clinical validity. No significant differences were observed between the three dental measurement techniques.

Case report - Digital Mockup을 활용한 심미 수복 치료 증례보고 (Case report - An esthetic restoration treatment based on digital mockup)

  • 권형규
    • 대한심미치과학회지
    • /
    • 제31권2호
    • /
    • pp.64-74
    • /
    • 2022
  • 최근 치과 임상 영역에 디지털이 접목되면서 디지털을 활용한 임상 진료가 점차 일반화되어가고 있다. 현재까지의 디지털 치과진료는 구강스캔 등의 자료채득, 가이드를 활용한 수술, CAD CAM을 사용한 보철물 제작 등의 직접적인 부분에 다소 집중된 감이 있으나, 치과 진료의 시작인 진단 및 치료계획 수립 단계에서도 디지털의 활용은 큰 효용을 가지고 있다. 이번 증례에서는 전치부 수복을 위해 내원한 환자에게 구치부를 포함한 상악 전체의 수복을 이해시키고, 교합고경을 재설정하여 수복하는 과정의 가이드라인으로 사용한 digital mockup의 활용 예를 보고하고자 한다.