• Title/Summary/Keyword: Diffusion-weighted imaging (DWI)

Search Result 102, Processing Time 0.025 seconds

Quantitative and Qualitative Evaluation of Brain Diffusion Weighted Magnetic Resonance Imaging: Comparision with 1.5 T and 3.0 T Units (뇌 확산강조 자기공명영상에 대한 정량적, 성적 평가: 1.5 T와 3.0 T 기기 비교)

  • Goo, Eun-Hoe;Dong, Kyung-Rae
    • Journal of Radiation Industry
    • /
    • v.10 no.4
    • /
    • pp.227-230
    • /
    • 2016
  • DWI of biological effects are independent of magnetic field strength in various regions. High field strength, however, does affect the signal to noise ratio (SNR) and artifacts of diffusion weighted imaging (DWI) images, which ultimately will influence the quantitative of diffusion imaging. In this study, the effects of field strength on DWI are reviewed. The effects of the diseases also are discussed. Comparing DWI in cerebellum, WM, GM, Hyperacute region measurements both as a function of field strength (1.5T and 3.0T). Overall, the SNR of the DWI roughly doubled going from 1.5 T to 3.0 T. In summary, DWI studies at 3.0 T is provided significantly improved DWI measurements relative to studies at 1.5T.

Assessment of Diffusion-Weighted Imaging-FLAIR Mismatch: Comparison between Conventional FLAIR versus Shorter-Repetition-Time FLAIR at 3T

  • Goh, Byeong Ho;Kim, Eung Yeop
    • Investigative Magnetic Resonance Imaging
    • /
    • v.20 no.2
    • /
    • pp.88-94
    • /
    • 2016
  • Purpose: Fluid-attenuated inversion recovery (FLAIR) imaging can be obtained faster with shorter repletion time (TR), but it gets noisier. We hypothesized that shorter-TR FLAIR obtained at 3 tesla (3T) with a 32-channel coil may be comparable to conventional FLAIR. The aim of this study was to compare the diagnostic value between conventional FLAIR (TR = 9000 ms, FLAIR9000) and shorter-TR FLAIR (TR = 6000 ms, FLAIR6000) at 3T in terms of diffusion-weighted imaging-FLAIR mismatch. Materials and Methods: We recruited 184 patients with acute ischemic stroke (28 patients < 4.5 hours) who had undergone 5-mm diffusion-weighted imaging (DWI) and two successive 5-mm FLAIR images (no gap; in-plane resolution, $0.9{\times}0.9mm$) at 3T with a 32-channel coil. The acquisition times for FLAIR9000 and FLAIR6000 were 108 seconds (generalized autocalibrating partially parallel acquisitions [GRAPPA] = 2) and 60 seconds (GRAPPA = 3), respectively. Two radiologists independently assessed the paired imaging sets (DWI-FLAIR9000 and DWI-FLAIR6000) for the presence of matched hyperintense lesions on each FLAIR imaging. The signal intensity ratios (area of DWI lesion to contralateral normal-appearing region) on both FLAIR imaging sets were compared. Results: DWI-FLAIR9000 mismatch was present in 39 of 184 (21.2%) patients, which was perfectly the same on FLAIR6000. Three of 145 patients (2%) with DWI-matched lesions on FLAIR9000 had discrepancy on FLAIR6000, showing no significant difference (P > 0.05). Interobserver agreement was excellent for both DWI-FLAIR9000 and DWI-FLAIR6000 (k = 0.904 and 0.883, respectively). Between the two FLAIR imaging sets, there was no significant difference of signal intensity ratio (mean, standard deviation; $1.25{\pm}0.20$; $1.24{\pm}0.20$, respectively) (P > 0.05). Conclusion: For the determination of mismatch or match between DWI and FLAIR imaging, there is no significant difference between FLAIR9000 and FLAIR6000 at 3T with a 32-channel coil.

Serial Magnetic Resonance Images of a Right Middle Cerebral Artery Infarction : Persistent Hyperintensity on Diffusion-Weighted MRI Over 8 Months

  • Son, Seung-Nam;Choi, Dae-Seob;Choi, Nack-Cheon;Lim, Byeong-Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.50 no.4
    • /
    • pp.388-391
    • /
    • 2011
  • A lesion that is hyperintense on diffusion-weighted imaging (DWI) and hypointense on the apparent diffusion coefficient (ADC) map is a characteristic magnetic resonance imaging (MRI) finding in acute ischemic infarction. In some cases, however, these findings can persist for a few months after infarct onset. It is thought that these finding reflect the different evolution speeds of the infarcted tissue. We report a patient with a right middle cerebral artery territory infarction with persistent hyperintensity on DWI and hypointensity on the ADC map for over 8 months. To our knowledge, this is the most persistent case of hyperintensity lesion on DWI and the serial MRI images of this patient provide important information on the evolution of infarcted tissue.

Recurrence and Metastasis of Lung Cancer Demonstrate Decreased Diffusion on Diffusion-Weighted Magnetic Resonance Imaging

  • Usuda, Katsuo;Sagawa, Motoyasu;Motomo, Nozomu;Ueno, Masakatsu;Tanaka, Makoto;Machida, Yuichiro;Maeda, Sumiko;Matoba, Munetaka;Tonami, Hisao;Ueda, Yoshimichi;Sakuma, Tsutomu
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.16
    • /
    • pp.6843-6848
    • /
    • 2014
  • Background: Diffusion-weighted magnetic resonance imaging (DWI) is reported to be useful for detecting malignant lesions. The purpose of this study is to clarify characteristics of imaging, detection rate and sensitivity of DWI for recurrence or metastasis of lung cancer. Methods: A total of 36 lung cancer patients with recurrence or metastasis were enrolled in this study. While 16 patients underwent magnetic resonance imaging (MRI), computed tomography (CT) and positron emission tomography-computed tomography (PET-CT), 17 underwent MRI and CT, and 3 underwent MRI and PET-CT. Results: Each recurrence or metastasis showed decreased diffusion, which was easily recognized in DWI. The detection rate for recurrence or metastasis was 100% (36/36) in DWI, 89% (17/19) in PET-CT and 82% (27/33) in CT. Detection rate of DWI was significantly higher than that of CT (p=0.0244) but not significantly higher than that of PET-CT (p=0.22). When the optimal cutoff value of the apparent diffusion coefficient value was set as $1.70{\times}10^{-3}mm^2/sec$, the sensitivity of DWI for diagnosing recurrence or metastasis of lung cancer was 95.6%. Conclusions: DWI is useful for detection of recurrence and metastasis of lung cancer.

Differentiation between Glioblastoma and Solitary Metastasis: Morphologic Assessment by Conventional Brain MR Imaging and Diffusion-Weighted Imaging

  • Jung, Bo Young;Lee, Eun Ja;Bae, Jong Myon;Choi, Young Jae;Lee, Eun Kyoung;Kim, Dae Bong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.25 no.1
    • /
    • pp.23-34
    • /
    • 2021
  • Purpose: Differentiating between glioblastoma and solitary metastasis is very important for the planning of further workup and treatment. We assessed the ability of various morphological parameters using conventional MRI and diffusion-based techniques to distinguish between glioblastomas and solitary metastases in tumoral and peritumoral regions. Materials and Methods: We included 38 patients with solitary brain tumors (21 glioblastomas, 17 solitary metastases). To find out if there were differences in the morphologic parameters of enhancing tumors, we analyzed their shape, margins, and enhancement patterns on postcontrast T1-weighted images. During analyses of peritumoral regions, we assessed the extent of peritumoral non-enhancing lesion on T2- and postcontrast T1-weighted images. We also aimed to detect peritumoral neoplastic cell infiltration by visual assessment of T2-weighted and diffusion-based images, including DWI, ADC maps, and exponential DWI, and evaluated which sequence depicted peritumoral neoplastic cell infiltration most clearly. Results: The shapes, margins, and enhancement patterns of tumors all significantly differentiated glioblastomas from metastases. Glioblastomas had an irregular shape, ill-defined margins, and a heterogeneous enhancement pattern; on the other hand, metastases had an ovoid or round shape, well-defined margins, and homogeneous enhancement. Metastases had significantly more extensive peritumoral T2 high signal intensity than glioblastomas had. In visual assessment of peritumoral neoplastic cell infiltration using T2-weighted and diffusion-based images, all sequences differed significantly between the two groups. Exponential DWI had the highest sensitivity for the diagnosis of both glioblastoma (100%) and metastasis (70.6%). A combination of exponential DWI and ADC maps was optimal for the depiction of peritumoral neoplastic cell infiltration in glioblastoma. Conclusion: In the differentiation of glioblastoma from solitary metastatic lesions, visual morphologic assessment of tumoral and peritumoral regions using conventional MRI and diffusion-based techniques can also offer diagnostic information.

Performance Evaluation of a Rapid Three Dimensional Diffusion MRI

  • Numano, Tomokazu;Homma, Kazuhiro;Nishimura, Katsuyuki
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.356-358
    • /
    • 2002
  • MRI, particularly diffusion weighted imaging (DWI), plays vital roles in detection of the acute brain infarction$\^$1-4/ and others metabolic changes of biological tissues. In general, every molecule in biological tissues may diffuse and move randomly in three-dimensional space. However, in clinical diagnosis, only 2D-DWI is used. The authors have developed a new method for rapid three-dimensional DWI (3D-DWI). In this method, by refocusing of the magnetized spin with the applied gradient field, direction of which is opposite to phase encoding field. Magnetized spin of $^1$H is kept under the SSFP (steady state free precession)$\^$5-6/. Under SSFP, in addition of FID, spin echo and stimulated echo are also generated, so the acquired signal is increased. The signal intensity is increased depending on flip angle (FA) of magnetized spin. This phenomenon is confirmed by human brain and phantom studies. The performance of this method is quantitatively analyzed by using both of conventional spin echo DWI and 3D-DWI. From experimental results, three dimensional diffusion weighted images are obtained correctly for liquid phantoms (water, acetone and oil), diffusion coefficient is enhanced in each image. Therefore, this method will provide useful information for clinical diagnosis.

  • PDF

An Unusual Case of Japanese Encephalitis Involving Unilateral Deep Gray Matter and Temporal Lobe on Diffusion-Weighted MRI

  • Seok, Hee Young;Lee, Dong Hoon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.20 no.4
    • /
    • pp.250-253
    • /
    • 2016
  • Acute Japanese encephalitis (JE) is an endemic viral infectious disease in various parts of Far East and Southeast Asian countries including Korea. Bilateral thalami are the most common involving sites in JE. Other areas including the basal ganglia, substantia nigra, red nucleus, pons, cerebral cortex and cerebellum may be also involved. We report an extremely unusual brain diffusion-weighted MR imaging (DWI) findings in a 53-year-old man with serologically proven JE involving unilateral deep gray matter and temporal lobe, which shows multifocal high signal intensities in left thalamus, left substantia nigra, left caudate nucleus and left medial temporal cortex on T2-weighted image and DWI with iso-intensity on apparent diffusion coefficient (ADC) map.

Diffusion-Weighted Magnetic Resonance Imaging in the Diagnosis of Cerebral Venous Thrombosis : A Meta-Analysis

  • Lv, Bin;Jing, Feng;Tian, Cheng-lin;Liu, Jian-chao;Wang, Jun;Cao, Xiang-yu;Liu, Xin-feng;Yu, Sheng-yuan
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.3
    • /
    • pp.418-426
    • /
    • 2021
  • Objective : A role of diffusion-weighted imaging (DWI) in the diagnosis of cerebral venous thrombosis (CVT) is not well-understood. This study evaluates the effectiveness of DWI in the diagnosis of CVT. Methods : Literature search was conducted in electronic databases for the identification of studies which reported the outcomes of patients subjected to DWI for CVT diagnosis. Random-effects meta-analyses were performed to achieve overall estimates of important diagnostic efficiency indices including hyperintense signal rate, the sensitivity and specificity of DWI in diagnosing CVT, and the apparent diffusion coefficient (ADC) of DWI signal areas and surrounding tissue. Results : Nineteen studies (443 patients with 856 CVTs; age 40 years [95% confidence interval (CI), 33 to 43]; 28% males [95% CI, 18 to 38]; symptom onset to DWI time 4.6 days [95% CI, 2.3 to 6.9]) were included. Hyperintense signals on DWI were detected in 40% (95% CI, 26 to 55) of the cases. The sensitivity of DWI for detecting CVT was 22% (95% CI, 11 to 34) but specificity was 98% (95% CI, 95 to 100). ADC values were quite heterogenous in DWI signal areas. However, generally the ADC values were lower in DWI signal areas than in surrounding normal areas (mean difference-0.33×10-3 ㎟/s [95% CI, -0.44 to -0.23]; p<0.00001). Conclusion : DWI has a low sensitivity in detecting CVT and thus has a high risk of missing many CVT cases. However, because of its high specificity, it may have supporting and exploratory roles in CVT diagnosis.

Differentiation of Benign from Malignant Adnexal Masses by Functional 3 Tesla MRI Techniques: Diffusion-Weighted Imaging and Time-Intensity Curves of Dynamic Contrast-Enhanced MRI

  • Malek, Mahrooz;Pourashraf, Maryam;Mousavi, Azam Sadat;Rahmani, Maryam;Ahmadinejad, Nasrin;Alipour, Azam;Hashemi, Firoozeh Sadat;Shakiba, Madjid
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.8
    • /
    • pp.3407-3412
    • /
    • 2015
  • Background: The aim of this study was to evaluate and compare the accuracy of diffusion-weighted imaging (DWI), apparent diffusion coefficient (ADC) value, and time-intensity curve (TIC) type analysis derived from dynamic contrast-enhanced MR imaging (DCE-MRI) in differentiating benign from malignant adnexal masses. Materials and Methods: 47 patients with 56 adnexal masses (27 malignant and 29 benign) underwent DWI and DCE-MRI examinations, prior to surgery. DWI signal intensity, mean ADC value, and TIC type were determined for all the masses. Results: High signal intensity on DWI and type 3 TIC were helpful in differentiating benign from malignant adnexal masses (p<0.001). The mean ADC value was significantly lower in malignant adnexal masses (p<0.001). An ADC value< $1.20{\times}10^{-3}mm^2/s$ may be the optimal cutoff for differentiating between benign and malignant tumors. The negative predictive value for low signal intensity on DWI, and type 1 TIC were 100%. The pairwise comparison among the receiver operating characteristic (ROC) curves showed that the area under the curve (AUC) of TIC was significantly larger than the AUCs of DWI and ADC (p<0.001 for comparison of TIC and DWI, p<0.02 for comparison of TIC and ADC value). Conclusions: DWI, ADC value and TIC type derived from DCE-MRI are all sensitive and relatively specific methods for differentiating benign from malignant adnexal masses. By comparing these functional MR techniques, TIC was found to be more accurate than DWI and ADC.

Hypointensity on Susceptibility-Weighted Images Prior to Signal Change on Diffusion-Weighted Images in a Hyperacute Ischemic Infarction: a Case Study

  • Kim, Dajung;Lee, Hyeonbin;Jung, Jin-Man;Lee, Young Hen;Seo, Hyung Suk
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.2
    • /
    • pp.131-134
    • /
    • 2018
  • Susceptibility-weighted imaging (SWI) is well known for detecting the presence of hemorrhagic transformation, microbleeds and the susceptibility of vessel signs in acute ischemic stroke. But in some cases, it can provide the tissue perfusion state as well. We describe a case of a patient with hyperacute ischemic infarction that had a slightly hypodense, patchy lesion at the left thalamus on the initial SWI, with a left proximal posterior cerebral artery occlusion on a magnetic resonance (MR) angiography and delayed time-to-peak on an MR perfusion performed two hours after symptom onset. No obvious abnormal signals at any intensity were found on the initial diffusion-weighted imaging (DWI). On a follow-up MR image (MRI), an acute ischemic infarction was seen on DWI, which is the same location as the lesion on SWI. The hypointensity on the initial SWI reflects the susceptibility artifact caused by an increased deoxyhemoglobin in the affected tissue and vessels, which reflects the hypoperfusion state due to decreasing arterial flow. It precedes the signal change on DWI that reflects a cytotoxic edema. This case highlights that, in some hyperacute stages of ischemic stroke, hypointensity on an SWI may be a finding before the hyperintensity is seen on a DWI.