• 제목/요약/키워드: Diffusion tensor imaging

검색결과 114건 처리시간 0.022초

MEDICAL IMAGE ANALYSIS USING HIGH ANGULAR RESOLUTION DIFFUSION IMAGING OF SIXTH ORDER TENSOR

  • K.S. DEEPAK;S.T. AVEESH
    • Journal of applied mathematics & informatics
    • /
    • 제41권3호
    • /
    • pp.603-613
    • /
    • 2023
  • In this paper, the concept of geodesic centered tractography is explored for diffusion tensor imaging (DTI). In DTI, where geodesics has been tracked and the inverse of the fourth-order diffusion tensor is inured to determine the diversity. Specifically, we investigated geodesic tractography technique for High Angular Resolution Diffusion Imaging (HARDI). Riemannian geometry can be extended to a direction-dependent metric using Finsler geometry. Euler Lagrange geodesic calculations have been derived by Finsler geometry, which is expressed as HARDI in sixth order tensor.

The Software Development for Diffusion Tensor Imaging

  • Song, In-Chan;Chang, Kee-Hyun;Han, Moon-Hee
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2001년도 제6차 학술대회 초록집
    • /
    • pp.112-112
    • /
    • 2001
  • Purpose: We developed the software for diffusion tensor imaging and evaluated its feasibility in norm brains. Method: Five normal volunteers, aged from 25 to 29 years, were examined on a 1.5 T MR system. the diffusion tensor pulse sequence used a SE-EPI with 6 diffusion gradie directions of (1, 1, 0), (-1, 1,0), (1, 0, 1), (-1, 0, 1), (0, 1, 1), (0, 1, -1) and also with no diffusion gradient. A b-factor of 500 sec/mm2 was used. Measurement parameter were as follows; TR/TE=10000 ms/99 ms, FOV=240 mm, matrix=128$\times$128, slice thickness/gap=6 mm/0 mm, bandwidth=91 kHz and the number of total slices=20. Four repeated axial diffusion images were averaged for diffusion tensor imaging. A total scan 11 of 4 min 30 sec was used. Six full diffusion tensor components of Dxx, Dyy, Dzz, Dxy, Dxz and Dyz were obtained using two-point linear regression model from 7 diffusion-weight images at each pixel and fractional anisotropy and lattice index images was estimated fr their eigenvectors and eigenvalues. Our program was written on a platform of IDL. W evaluated the qualities of fractional anisotropy and lattice index images of normal brains a knew whether our software for diffusion tensor imaging may be feasible.

  • PDF

The Quantitative Diffusion-Tensor Anisotropy of Human Brain Using Fast STEAM DTI

  • 박현정;황문정;김용선;이상권;장용민
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2001년도 제6차 학술대회 초록집
    • /
    • pp.165-165
    • /
    • 2001
  • Purpose: To obtain quantitative diffusion-tensor anisotropy information of human cerebral structu using turbo STEAM diffusion-tensor imaging. Method: Quantitative diffusion anisotropy MR images were obtained in 7 healthy adults using turbo STEAM sequence and a combination of tetrahedral and orthogonal diffusi gradients. Both relative anisotropy(RA) and fractional anisotropy(FA) values were measured various brain regions. The anisotropy index was then compared with the reported valu resulting from EPI-based diffusion tensor imaging.

  • PDF

The Quantitative Diffusion-Tensor Anisotropy of Human Brain Using Fast STEAM DTI

  • 박현정;황문정;김용선;이상권;장용민
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2001년도 제6차 학술대회 초록집
    • /
    • pp.138-138
    • /
    • 2001
  • Purpose: To obtain quantitative diffusion-tensor anisotropy information of human cerebral structu using turbo STEAM diffusion-tensor imaging. Method: Quantitative diffusion anisotropy MR images were obtained in 7 healthy adults using turbo STEAM sequence and a combination of tetrahedral and orthogonal diffusi gradients. Both relative anisotropy(RA) and fractional anisotropy(FA) values were measured various brain regions. The anisotropy index was then compared with the reported valu resulting from EPI-based diffusion tensor imaging.

  • PDF

The Diffusion Tensor Imaging of Muscle Preliminary Results

  • 황문정;박현정;장용민;강덕식
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2001년도 제6차 학술대회 초록집
    • /
    • pp.167-167
    • /
    • 2001
  • Purpose: To obtain normative human skeletal muscle data and evaluate quantitative diffusion-ten anisotropy information using diffusion-tensor imaging technique. Method: Quantitative extremity muscle diffusion tensor MR images were obtained in 5 healt adults by using turbo STEAM sequence and a combination of tetrahedral and orthogon diffusion gradients. Relative anisotropy(RA) and fractional anisotropy(FA) values we measured in soleus and gastrocnemius muscle in addition to mean ADC value.

  • PDF

Significance of Preoperative Nerve Reconstruction Using Diffusion Tensor Imaging Tractography for Facial Nerve Protection in Vestibular Schwannoma

  • Yuanlong Zhang;Hongliang Ge;Mingxia Xu;Wenzhong Mei
    • Journal of Korean Neurosurgical Society
    • /
    • 제66권2호
    • /
    • pp.183-189
    • /
    • 2023
  • Objective : The facial nerve trace on the ipsilateral side of the vestibular schwannoma was reconstructed by diffusion tensor imaging tractography to identify the adjacent relationship between the facial nerve and the tumor, and to improve the level of intraoperative facial nerve protection. Methods : The clinical data of 30 cases of unilateral vestibular schwannoma who underwent tumor resection via retrosigmoid approach were collected between January 2019 and December 2020. All cases underwent magnetic resonance imaging examination before operation. Diffusion tensor imaging and anatomical images were used to reconstruct the facial nerve track of the affected side, so as to predict the course of the nerve and its adjacent relationship with the tumor, to compare the actual trace of the facial nerve during operation, verify the degree of coincidence, and evaluate the nerve function (House-Brackmann grade) after surgery. Results : The facial nerve of 27 out of 30 cases could be displayed by diffusion tensor imaging tractography, and the tracking rate was 90% (27/30). The intraoperative locations of facial nerve shown in 25 cases were consistent with the preoperative reconstruction results. The coincidence rate was 92.6% (25/27). The facial nerves were located on the anterior middle part of the tumor in 14 cases, anterior upper part in eight cases, anterior lower part in seven cases, and superior polar in one case. Intraoperative facial nerve anatomy was preserved in 30 cases. Among the 30 patients, total resection was performed in 28 cases and subtotal resection in two cases. The facial nerve function was evaluated 2 weeks after operation, and the results showed grade I in 12 cases, grade II in 16 cases and grade III in two cases. Conclusion : Preoperative diffusion tensor imaging tractography can clearly show the trajectory and adjacent position of the facial nerve on the side of vestibular schwannoma, which is beneficial to accurately identify and effectively protect the facial nerve during the operation, and is worthy of clinical application and promotion.

Mini-Review of Studies Reporting the Repeatability and Reproducibility of Diffusion Tensor Imaging

  • Seo, Jeong Pyo;Kwon, Young Hyeon;Jang, Sung Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • 제23권1호
    • /
    • pp.26-33
    • /
    • 2019
  • Purpose: Diffusion tensor imaging (DTI) data must be analyzed by an analyzer after data processing. Hence, the analyzed data of DTI might depend on the analyzer, making it a major limitation. This paper reviewed previous DTI studies reporting the repeatability and reproducibility of data from the corticospinal tract (CST), one of the most actively researched neural tracts on this topic. Materials and Methods: Relevant studies published between January 1990 and December 2018 were identified by searching PubMed, Google Scholar, and MEDLINE electronic databases using the following keywords: DTI, diffusion tensor tractography, reliability, repeatability, reproducibility, and CST. As a result, 15 studies were selected. Results: Measurements of the CSTs using region of interest methods on 2-dimensional DTI images generally showed excellent repeatability and reproducibility of more than 0.8 but high variability (0.29 to 1.00) between studies. In contrast, measurements of the CST using the 3-dimensional DTT method not only revealed excellent repeatability and reproducibility of more than 0.9 but also low variability (repeatability, 0.88 to 1.00; reproducibility, 0.82 to 0.99) between studies. Conclusion: Both 2-dimensional DTI and 3-dimensional DTT methods appeared to be reliable for measuring the CST but the 3-dimensional DTT method appeared to be more reliable.

확산텐서영상을 이용한 확산 주축의 고유치 영상 재구성 (Image Reconstruction of Eigenvalue of Diffusion Principal Axis Using Diffusion Tensor Imaging)

  • 김인성;김주현;연근;서경진;유돈식;강덕식;배성진;장용민
    • Investigative Magnetic Resonance Imaging
    • /
    • 제11권2호
    • /
    • pp.110-118
    • /
    • 2007
  • 목적: 확산텐서자기공명영상(DT-MRI: Diffusion Tensor Image)을 이용하여 확산의 주축을 구성하는 세 성분에 대한 고유치 (eigefvalue)의 영상을 구현해 보고자 하였다. 대상 및 방법: 고유치 영상을 구현하기 위해서 3.0 테슬러 MRI(Magnetic Resonance Imaging)를 이용하여 확산텐서영상을 얻었으며, Moore-Penrose pseudo-inverse 방법과 SVD(single value decomposition) 방법을 이용하여 확산 주축을 계산하였다. 이 과정을 픽셀단위로 반복적으로 계산하여 새로운 확산 주축 영상들을 만들었으며, 이 확산 주축 영상들과 분할 비등방성 영상의 관계를 조사하였다. 결과: 확산텐서영상 기법으로 얻어진 확산텐서영상을 이용하여, 세 방향의 확산 주축에 대한 고유치 영상을 구성하였으며, 고유치 영상들과 분할 비등방성 영상을 함께 분석함으로써, 뇌의 해부학적 구조물에 따른 분할 비등방성 값의 차이를 확인할 수 있었다. 또한, 확산 주축에 대한 고유치의 변화에 대한 컴퓨터 모의실험에서, 변화하는 고유치에 따른 분할 비등방성 값의 변동 추이를 알아볼 수 있었다. 그리고 확산 주축의 크기가 비등방성을 좌우하는 것이 아니라, 세 확산 주축의 조합으로 비등방성의 정도를 표현한다는 것을 확인할 수 있었다. 확산 주축 방향의 고유치들을 분리하여 영상화 함으로써, 뇌의 병변에 의한 비등방성의 변화의 원인이 확산 주축의 어떠한 변화에 의해 발생하는 것인지 확인할 수 있을 것으로 기대된다.

  • PDF

일회 영상으로 확산텐서 자기공명영상을 얻을 수 있는 다편-다에코 펄스 경사자장 스핀에코(MePGSE) 시퀀스의 초기 결과 (Multi-slice Multi-echo Pulsed-gradient Spin-echo (MePGSE) Sequence for Diffusion Tensor Imaging MRI: A Preliminary Result)

  • 장건호
    • 한국의학물리학회지:의학물리
    • /
    • 제18권2호
    • /
    • pp.65-72
    • /
    • 2007
  • 대부분의 임상용 자기공명영상 장치에서 확산텐서(difiusion tensor) 영상을 얻기 위하여 에코플렌(EPI) 스핀에코(spin-echo) 시퀀스를 사용한다. 하지만 이 영상법은 자화감수성에 매우 예민한 단점이 있다. 따라서 본 연구의 목적은 자화감수성에 의해 발생하는 영상의 변질을 최소화하면서 확산텐서를 한번에 얻을 수 있는 시퀀스를 개발하는데 있다. 모든 확산 텐서 성분을 한번에 얻기 위하여 다편(multi-slice) 8에코 스핀에코 시퀀스(MePGSE)가 개발되었다. 모든 180도 펄스는 기존에 사용된 방법과는 달리 선택된(slice selective) 경사자장을 이용하였다. 처음 7개의 에코 영상은 확산텐서 영상을 위하여 사용하였고, 마지막 에코 영상에서는 영상을 얻는 경사자장은 사용하지 않고 남아있는 자화를(residual magnetization) 최소화하기 위하여 삼차원 경사자장(crusher gradients)만을 사용하였다. 따라서 6개의 텐서 성분을 단 한번의 실험에 의하여 얻을 수 있었다. 이 시퀀스를 사용하여 물과 수박을 이용하여 실험을 하였으며 물에서의 확산 값이 기존에 출판된 값과 유사하게 나타나 본 연구에서 MePGSE 시퀀스의 신뢰를 가질 수 있었다.

  • PDF

In vivo Visualization of Human White Matter Tract by Diffusion Tensor Imaging Fiber Tractography (DTI-FT)

  • Lee, Seung-Koo;Kim, Dong-Ik
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2002년도 제7차 학술대회 초록집
    • /
    • pp.85-85
    • /
    • 2002
  • Purpose: To evaluate the white matter fiber connectivity of normal human using diffusion tensor MRI. Method: Normal young healthy volunteers (2 women and 1 man) and 3 brain tumor patients participated in this study. All studies were performed using a 1.5T Philips Gyroscan Intern system. Diffusion weighted imaging was performed using single-shot echo planar imaging, with navigator echo phase correction and SENSE. Diffusion weighting was performed along six independent axes, using diffusion weighting of b=800s/$\textrm{mm}^2$. 128matrix, 23cm FOV, 2.5mm slice thickness were used for Imaging parameters. Data were processed on a Window-2000 PC equipped with IDL and PRIDE (Philips Medical System). Corticospinal tract was traced from mid-pons level via posterior limb of internal capsule. Corpus callosum, cerebellar peduncles and frontal fibers were traced by fiber tractography.