• 제목/요약/키워드: Diffusion Ratio

검색결과 891건 처리시간 0.027초

물시멘트비 및 도장재 종류에 따른 콘크리트의 염소이온 확산특성에 관한 실험적 연구 (An Experimental Study on the Chloride Diffusion Properties in Concrete according to the Water-Cement Ratio and Coating Materials)

  • 이태희;김용로;김재환;강석표;권영진;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.679-684
    • /
    • 2002
  • In this study we performed test to compare and analyze the chloride diffusion properties in concrete according to organic coating materials used at concrete structures widely and inorganic coating materials as eco-materials in recently. The results of study were shown as follow ; 1) Chloride diffusion coefficient was low as low as and that of organic and inorganic painted was lower than non-painting 2) In case of inorganic coating material applied in this study, it should be possible to evaluate the chloride diffusion properties by CTH method. Because presumption value by CTH method is similar with real estimate value by digestion experiment.

  • PDF

An Experimental Study of the Diffusion Flame Characteristics for the Gas Fueled Torch System

  • Choi, Hyun-Kyung;Choi, Seong-Man
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제7권2호
    • /
    • pp.50-55
    • /
    • 2006
  • Currently, a gas fueled diffusion flame is used for the relay torch system. It could be burned cleanly but should be stable at severe weather condition such as rain of up to 55 mm/h, winds of up to 70 km/h and also produce a highly bright yellow visible flame. This paper presents torch diffusion flame characteristics on the various wind speeds and rainfall conditions. From the results, flame lengths are controlled by the momentum flux ratio of fuel and ambient air flow and flame stability is much influenced by the mixing characteristics with air flow. Flame is fluctuated above than 200 mm/h rainfall and blow out is occurred about 300 mm/h rainfall condition.

광물질 혼화재가 콘크리트의 염화물 확산계수에 미치는 영향 (Effect of Mineral Admixture on Coefficient of Chloride Diffusion in Concrete)

  • 김명유;양은익;민석홍;심상배;최중철;이광교
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.281-284
    • /
    • 2003
  • When concrete structures are exposed under marine condition for a long time, the steel in concrete is corroded due to the ingression of chlorides in the sea water. Because the damages of corrosion resulting from the chloride ion are very serious, many research have been performed. In this study, it was experimentally investigated that the mechanical and diffusion characteristics of concrete substituted with ordinary portland cement, silica fume and blast furnace slag to investigate the chloride ingress characteristics with concrete quality. Chloride diffusion coefficients in concrete shows increasing tendency as w/c ratio increase. Also test results indicate that blend of admixture become lower chloride diffusion coefficients in concrete as compared with normal concrete.

  • PDF

순환잔골재를 사용한 모르타르의 염화물확산계수 평가 (Evaluation on Chloride Diffusion Coefficient of Mortar with Recycled Fine Aggregate)

  • 윤민호;김규용;최경철;황의철;서원우;이상윤
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 춘계 학술논문 발표대회
    • /
    • pp.209-210
    • /
    • 2016
  • Mechanical properties and durability of recycled aggregate concrete was known to decrease due to the adhesive mortar of recycled aggregate. But in this study, As the result of chloride diffusion resistance of recycled fine aggregate mortar, the mechanical properties are reduced according to the increase of the substitute ratio of recycled fine aggregate. But the chloride diffusion coefficient was almost same with natural fine aggregate mortar.

  • PDF

Formation and Growth of Hydride Blisters in Zr-2.5Nb Pressure Tubes

  • Cheong, Yong-Moo;Gong, Un-Sik;Choo, Ki-Nam;Kim, Sung-Soo;Kim, Young-Suk
    • Nuclear Engineering and Technology
    • /
    • 제33권2호
    • /
    • pp.192-200
    • /
    • 2001
  • Hydride blisters were formed on the outer surface of Zr-2.5Nb pressure tube by a non- uniform steady thermal diffusion process. A thermal gradient was applied to the pressure tube with a heat bath kept at a temperature of 415$^{\circ}C$ and an aluminum cold finger cooled with flowing water of 15$^{\circ}C$. Optical microscopy and tree-dimensional laser profilometry were used to characterize the hydride blisters with different hydrogen concentrations and thermal diffusion time. Hydride blisters were expected to start at a hydrogen concentration of 30 - 70 ppm and a thermal diffusion time of 4 - 6$\times$10$^{5}$ sec. The hydride blister size increases with higher hydrogen concentrations and longer thermal diffusion time . Some of the samples revealed cracks on the hydride blisters. The ratio of hydride blister depth to height was estimated as approximately 8: 1.

  • PDF

Diffusion of ICT from the view of ICT generation: The experience in the UK during the 1980s

  • Hwang, Gyu-hee
    • 한국기술혁신학회:학술대회논문집
    • /
    • 한국기술혁신학회 2001년도 춘계학술대회:발표자료
    • /
    • pp.205-242
    • /
    • 2001
  • This paper aims to provide a better understanding about how Information and Communication technology (ICT) has diffused. The investigation is conducted with the consideration of ICT evolution in terms of technological change and usage pattern. The definition used is presented as 'the ICT is a process of convergence of technologies between information-processing and information-transforming technologies, mainly due to the advent of microelectronlcs'. After examining technological changes of ICT, the diffusion path of ICT is traced through the usage ratio in total input and/or investment based on Input-Output tables (I-O). It shows that the evolution of ICT from the change of usage pattern is an up-and-down usage pattern rather than a uni-modal usage time path. With this recognition, the diffusion index is prepared. JEL classification : C43, L63, O33.

  • PDF

염해에 노출된 콘크리트의 내구수명 확보를 위한 최적 배합 도출에 대한 연구 - 유전자 알고리즘의 적용 (Study on Optimum Mixture Design for Service Life of RC Structure subjected to Chloride Attack - Genetic Algorithm Application)

  • 권성준;이성칠
    • 대한토목학회논문집
    • /
    • 제30권5A호
    • /
    • pp.433-442
    • /
    • 2010
  • 콘크리트의 염화물 확산계수의 제어는 염해에 노출된 콘크리트 구조물의 내구수명 확보에 필수적이며, 이를 위해 많은 연구가 진행되어 왔다. 본 연구는 목표 내구수명을 만족하는 목표확산계수를 도출하고 유전자 알고리즘을 통하여, 최적배합을 도출하는데 있다. 이를 위하여, 동일한 골재 및 혼화재를 사용한 30개의 배합과 그에 따른 염화물 확산계수를 분석하였으며, 27개를 대상으로 확산계수 예측식을 도출하였다. 확산계수 예측식의 변수로는 물-결합재비, 단위 혼화재량(슬래그, 플라이 애쉬, 실리카퓸), 단위 시멘트량, 단위 잔골재 및 굵은 골재량을 포함하도록 하였으며 나머지 3개의 배합에 대하여 검증을 수행하였다. 최적 함수식은 27개의 배합에 대하여 평균 18.7%의 오차와 16.0%의 변동계수를 보이고 있었다. 주어진 3개의 확산계수에 대하여, 유전자 알고리즘을 통하여 도출된 배합은 0.3%~12.2%의 오차범위를 가지며 각각의 배합인자를 도출하였다. 최종적으로 서로 다른 내구성 설계변수(목표내구수명, 피복두께, 표면염화물량, 혼화재량)와 노출환경(온도 및 습도)을 가정하여 목표 확산계수를 도출하였으며, 이에 만족하는 최적화된 콘크리트 배합을 제안하였다. 본 연구에서는 유전자 알고리즘을 이용하여, 내구성 콘크리트 배합도출에 대한 적용성을 평가하였으며, 제안된 기법은 다양한 확산계수의 범위를 가지는 광범위한 자료구축을 통하여 개선될 것이다.

고온 고분자 막 전해질 연료전지 캐소드의 가스 확산층 및 바인더 함량에 따른 완화 시간 분포(DRT) 저항 분석 (Resistance Analysis by Distribution of Relaxation Time According to Gas Diffusion Layers and Binder Amounts for Cathode of High-temperature Polymer Electrolyte Membrane Fuel Cell)

  • 김동희;정현승;박찬호
    • 한국수소및신에너지학회논문집
    • /
    • 제34권3호
    • /
    • pp.283-291
    • /
    • 2023
  • The physical properties were analyzed for four gas diffusion layers, and gas diffusion electrodes (GDEs) for the cathode of high-temperature polymer electrolyte membrane fuel cell were fabricated through bar coating with three binder to carbon (B/C) ratios. Among them, The GDE from JNT30-A6P showed a significant change in secondary pore volume at a B/C ratio of 0.31, which had the largest pore volume among all GDEs. In the polarization curve, JNT30-A6P GDE showed the best membrane electrode assembly (MEA) performance with a peak power density of 384 mW/cm2 at a a B/C ratio of 0.31. From the distribution of relaxation time analysis, the peak 1 corresponding to mass transfer resistance of oxygen reduction reaction (ORR) was significantly reduced in the JNT30-A6P GDE. This is the result that when the binder content decreased, the volume of the secondary pore increased, and the mass transfer resistance of ORR decreased, which played an essential role in the MEA performance.

고로슬래그 미분말 콘크리트의 분말도 및 치환율에 따른 염해 저항성 평가 (Evaluation of Chloride Penetration in Concrete with Ground Granulated Blast Furnace Slag considering Fineness and Replacement Ratio)

  • 이현호;권성준
    • 한국건설순환자원학회논문집
    • /
    • 제1권1호
    • /
    • pp.26-34
    • /
    • 2013
  • RC 구조물의 내구성능 피복두께의 변화뿐 아니라 배합조건에 따라 크게 변화한다. 고로슬래그 미분말은 유용한 혼화재료이며, 최근들어 염해에 대한 저항성을 확보하기 위해 많이 사용되고 있다. 본 연구는 고로슬래그 미분말을 30~70%로, 분말도를 $4,000{\sim}8,000cm^2/g$으로 변화시키면서 공극률, 압축강도, 확산계수의 변화를 분석하였다. 실험결과 고로슬래그 미분말을 혼입한 콘크리트는 보통 콘크리트에 비하여 조밀한 공극구조, 높은 강도발현과 확산계수 감소를 확보하였으며, 분말도보다 치환율에 더욱 민감하게 변화하였다. 고로슬래그 미분말 콘크리트에서 재령이 3일에서 91일로 증가함에 따라 공극률은 77.47% 수준으로 감소하였으며, 압축강도는 373%로 증가하였다. 또한 염화물 확산계수는 OPC 콘크리트의 64.4% 수준으로 감소하여 내구적 저항성이 크게 개선됨을 알 수 있었다.