• 제목/요약/키워드: Diffuser Design Parameters

검색결과 42건 처리시간 0.024초

고고도 모사용 초음속 디퓨져의 설계인자 및 작동인자에 대한 연구 (Study on Design- and Operating- Parameters of Supersonic Exhaust Diffusers Simulating high Altitude)

  • 윤상규;김진곤;성홍계;김용욱;오승협
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2007년도 제28회 춘계학술대회논문집
    • /
    • pp.303-306
    • /
    • 2007
  • 고고도 모사용 초음속 디퓨져의 설계 및 작동인자에 대한 영향을 파악하기 위하여 압축성 축대칭 Wavier-Stokes 방정식 기반의 two-layer k-$\varepsilon$ 난류 수치해석과 실험 결과를 비교 분석하였다. 디퓨져의 설계 및 작동인자인 노즐과 디퓨져의 면적비, 진공챔버의 크기, 제트의 공급압력에 대한 디퓨져내 유동 발달과 디퓨져 작동 특성을 살펴보았다.

  • PDF

원심압축기용 베인디퓨져의 탈설계점 성능연구 - 제2부 : 솔리디티가 작은 익렬디퓨져 - (Investigation of Off-Design Performance of Vaned Diffusers in Centrifugal Compressors - Part II : Low Solidity Cascade Diffuser -)

  • 오종식;이헌석
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2001년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.91-98
    • /
    • 2001
  • As the second part of the author's study, off-design behavior of the design and performance parameters in the low-solidity cascade diffuser in a centrifugal compressor is investigated. The experimental flange-to-flange compressor map serves the validity of application of the present CFD work to the detailed investigation of the low-solidity cascade diffuser. Some meanline design and performance parameters as well as three-dimensional internal secondary flow fields are studied when the flow rate is changed from deep choke to stall.

  • PDF

소형 디퓨저의 최적화 설계 (Optimization Design of Compact Diffuser)

  • 이영태
    • 반도체디스플레이기술학회지
    • /
    • 제21권4호
    • /
    • pp.163-167
    • /
    • 2022
  • In this paper, an optimization design method of a diffuser using Bernoulli's theorem was reviewed. The aspect ratio of the cylindrical diffuser chamber and the diameter ratio of the air inlet and outlet were used as design parameters. For the optimal design of the cylindrical diffuser chamber, the air flow inside the chamber was simulated using ANSYS while changing the aspect ratio of the chamber. In order to confirm the simulation results, the diffuser manufactured using the laser processing machine was measured. Through ANSYS simulation and measurement, it was found that the optimal design condition was when the aspect ratio (chamber height/radius) of the diffuser chamber was 1/2 and the diameter ratio of the air inlet and outlet was also 1/2.

원심압축기용 베인디퓨져의 탈설계점 성능연구 - 제1부 : 채널디퓨져 - (Investigation of Off-Design Performance of Vaned Diffusers in Centrifugal Compressors - Part I : A Channel-Wedge Diffuser -)

  • 오종식;현용익
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2001년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.83-90
    • /
    • 2001
  • Experimental and numerical investigations of the off·design performance of a simple channel-wedge diffuser in a small centrifugal compressor are presented. Surge and choke conditions as well as design point are considered using somewhat limited range of experimental data and also supplementary 3D CFD results. Some critical meanline design parameters' behavior is investigated numerically, to render the basis for improved modelings in the meanline performance prediction.

  • PDF

전투기 후류처리용 엄체호 최적설계에 관한 연구 (A Study on Optimal Design of the Fighter Igloo Diffuser)

  • 윤용현
    • 한국항공운항학회지
    • /
    • 제18권4호
    • /
    • pp.86-91
    • /
    • 2010
  • New Design configurations of the fighter aircraft igloo diffuser were studied based on the closed ventilation type in contrast to the conventional open distribution type. To validate the enhanced and safe performance, the exhaust flow patterns of the two igloo diffuser types were simulated by both experimental and computational approaches as design tools. Flow visualizations were conducted to investigate the exhaust flow patterns in experimental approach. In addition, the commercial code called Fluent was used to calculate flow field properties. Computational simulations provided detailed parametric studies that significantly reduced the amount of experimentation necessary to alter the design parameters of the existing fighter igloo diffuser. The closed ventilation type of the igloo diffuser was shown the better results.

예측수정된 Stanitz 방정식을 이용한 임펠러 출구 조건 해석 (Analysis of impeller exit condition using a modified Stanitz equation in a centrifugal refrigerant compressor)

  • 정진희;김춘동;이현구;이용덕
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1999년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.61-68
    • /
    • 1999
  • We have measured pressure distributions within the diffuser and pressures at the inlet and outlet of the compressor in orde to match impeller and low-solidity diffuser of 500RT centrifugal refrigerant-compressor which has been developed in LG Cable Ltd. Modified Stanitz equation is used to predict the measured data by tuning several parameters and then is validated. Using the validated parameters and modified Stanitz equation, we have obtained data necessary to design the diffuser.

  • PDF

중형버스 다출구 덕트의 최적설계에 관한 해석적 고찰 (A Numerical Analysis on the Optimum Design of a Duct with Multiple Outlets in a Medium Bus)

  • 김민호;천인범;이대훈
    • 한국자동차공학회논문집
    • /
    • 제10권4호
    • /
    • pp.223-233
    • /
    • 2002
  • The air distribution duct with multiple outlets is an essential part of automotive air-conditioning system In a bus. The estimation of airflow rate in an automotive air-conditioning duct is typically very complicate due to large variations in cross-sectional area and abrupt changes in flow direction, as well as unbalanced distribution of the flow. In this paper, the flow characteristic in a duct with multiple outlets is investigated through experiment, CFD simulation and a one-dimensional simulation. Numerical simulations have been performed for two simplified air conditioning ducts with multiple outlets used in a medium bus. The three dimensional Navier-Stokes code was used to evaluate the overall pressure, velocity Held, and distribution rate at each diffuser according to the change of various design parameters such as ratio of cross-sectional area and radius of bifurcated region. In addition, a one-dimensional program based on Bernoulli equation was developed to obtain optimized diffuser area required to equalize discharge flow rate at each outlet. As a result of this study, optimized diffuser area of design variable by one-dimensional program was very reasonable as compared to the trend deduced from CFD Simulation. Therefore, the simple and convenient one-dimensional analysis developed in this study can be applied in practical design procedure for air-conditioning duct.

고도모사용 2 차목 초음속 디퓨져 시동특성에 영향을 미치는 파라미터에 관한 연구 (Investigation of the essential parameters governing starting characteristic in the second throat exhaust diffuser for high altitude simulation)

  • 박성현;박병훈;임지환;윤웅섭
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2642-2647
    • /
    • 2008
  • Starting characteristics of the axi-symmetric supersonic exhaust diffuser(SED) with a second throat are numerically investigated. Main purpose of this study is to predict theoretical starting pressure of STED using 1-D normal shock theory and to present the range of optimum starting pressure through parametric study with essential design parameters of STED influencing on starting performance. Renolds-Average Navier-Stokes equations with a standard ${\kappa}-{\varepsilon}$ turbulence model incorporated with standard wall function are solved to simulate the diffusing evolutions of the nozzle plume. Minimum(optimum) starting pressure difference of $20{\sim}25%$ between 1-D theory and experimental evidences validated from previous results[5] is also applied to predict those in this system. The analysis results indicate that dominant parameters for diffuser starting in this system is diffuser expansion ratio($A_d/A_t$), which has optimum value 120 and second throat area ratio($A_d/A_{st}$), which has optimum range $3.3{\sim}3.5$.

  • PDF

성층축열조의 성능에 대한 설계인자의 영향 (Effect of Design Factors on the Performance of Stratified Thermal Storage Tank)

  • 정재동;박주혁;조성환
    • 설비공학논문집
    • /
    • 제16권11호
    • /
    • pp.1077-1083
    • /
    • 2004
  • This study is to systematically analyze the effect of various kinds of design factors on the performance of stratified thermal storage tank. Taguchi method, known as a very reasonable tool in the parametric study, is employed in the present work. Three dimensional unsteady numerical experiment is conducted for 4 design parameters of stratified thermal storage tank: inlet Reynolds number, Froude number, diffuser size d with 3 levels (Re=400, 800, 1200, Fr=0.5, 1.0, 2.0 and d=150 mm, 200mm, 300 mm) and diffuser shape with 2 levels. Orthogonal array $L_{18}(2{\times}3^7)$ is adopted for the analysis of variance. The result gives quantitative estimation of the various design parameters affecting the performance and helps to select the main factors for the optimum design of stratified thermal storage tank. Reynolds number is found to be the most dominant parameter and the diffuser shape plays significant role on the performance of stratified thermal storage tank. Based on this finding, the prior questions on the contribution of the diffuser shape proposed by the authors become clear. The optimum condition for the performance is a set of d=300mm, Re=800, and radial regulated plate diffuser. Conformation test shows the repeatability in the analysis and $1.3\%$ difference between the estimated thermocline thickness and that of numerical result.

Flow Dynamics in a Supersonic Diffuser at Minimum Starting Condition to Simulate Rocket's High Altitude Test on the Ground

  • Yeom, Hyo-Won;Yoon, Sang-Kyu;Sung, Hong-Gye;Kim, Yong-Wook;Oh, Seung-Hyup
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년 영문 학술대회
    • /
    • pp.442-447
    • /
    • 2008
  • A numerical analysis has been conducted to investigate and characterize the unsteadiness of flow structure and oscillatory vacuum pressure inside of a supersonic diffuser equipped to simulate the high-altitude rocket test on the ground. A physical model of concern includes a rocket motor, a vacuum chamber, and a diffuser, which have axisymmetric configurations, using nitrogen gas as a driving fluid. Emphasis is placed on investigating physical phenomena of very complex and oscillatory flow evolutions in the diffuser operating at very close to the starting condition, i.e. minimum starting condition, which is one of major important parameters in diffuser design points of view.

  • PDF