• 제목/요약/키워드: Diffraction

검색결과 8,643건 처리시간 0.039초

도체와 유전체가 복합된 쐐기에 의한 E-편파된 전자파의 회절, II:확장된 회절계수 (E-polarized electromagnetic diffraction by a composite wedge, II:Extended diffraction coefficients)

  • 김세윤;김상욱
    • 전자공학회논문지D
    • /
    • 제34D권7호
    • /
    • pp.1-7
    • /
    • 1997
  • The physical optical solution to the E-polarized diffraction by a composite wedge consisting of perfect conductor and lossless dielectric cannot sayisfy not only the boundary conditions at the wedge interfaces but also the edge condition at the wedge tip. Its diffraction coefficients are extended outside the composite wedge to become the exact solution to the perfectly conducting wedge as its relative dielectric constant increases to infinite or decreases to 1. It is assured that the extended diffraction coefficients approach zero in the arificially complementary region of the composite wedge.

  • PDF

복합쐐기의 유전체 영역에서 확장된 E-편파 회절계수 (E-polarized diffraction coefficients extended inside dielectric region of a composite wedge)

  • 김세윤
    • 전자공학회논문지D
    • /
    • 제34D권7호
    • /
    • pp.8-14
    • /
    • 1997
  • The phusical optics approximation to an E-polarized diffraction by a composite wedge provides its diffraction coefficients in terms of finite series of cotangent functions. In this paper, its diffraction coefficients inside the dielectric part are extended to become the exact solution to the perfectly conducting wedge as its relative dielectric constant increases to infinite or decreases to 1. It is assured that the extended diffraction coefficients satisfy the boundary condition at th econducting interface and become zero in the artificially complementary region of the composite wedge.

  • PDF

Review of the Hidden Rays of Diffraction

  • Kim, Se-Yun
    • Journal of electromagnetic engineering and science
    • /
    • 제15권1호
    • /
    • pp.1-5
    • /
    • 2015
  • A high-frequency analysis technique, called the hidden rays of diffraction (HRD), is reviewed in this paper. The physical optics and the rigorous diffraction coefficients of a perfectly conducting wedge illuminated by a plane wave are compared. The physical existence of hidden rays on the shadow boundary is explained in view of the geometric theory of diffraction (GTD). In particular, a systematic tracing of hidden rays and its visualization are precisely described by introducing the concept of the supplementary boundary. The physical meaning of the null-field condition in the complementary region is also explained.

전자회절실험에 의한 알루미늄 합금 (Al-Cu-Mg)의 미세 S-상 석출입자에 대한 결정구조 연구 (A Study of the Crystal Structure of the Fine S-Phase Precipitate in Al-Cu-Mg Alloy by Electron Diffraction Experiments)

  • 김황수
    • Applied Microscopy
    • /
    • 제35권4호
    • /
    • pp.1-9
    • /
    • 2005
  • 이 논문에서 Al-Cu-Mg 합금의 미세 석출 입자의 S-상 ($Al_2CuMg$) 결정구조에 대해 전자회절실험에 의한 포괄적인 연구 결과가 보고 되어 있다. 이 실험에는 한 S-상 입자를 포함하는 최소 영역의 일정 zone축의 회절패턴(SAED) 관찰과 이에 대응되는 운동학적 이론을 기초로 한 패턴의 시물레이션과의 비교 분석, 그리고 관측된 회절 패턴 필름으로부터 각 Bragg회절 점의 강도의 정량적 데이터 추출과 운동학적 및 동역학적 회절 강도 계산과의 비교 검토의 과정을 포함하고 있다. 이러한 연구의 한 결과 S-상의 결정구조는 일찍이 X-ray 방법으로부터 얻은 PW 모델결정(Perlitz and Westgren, 1943)과 일치함을 보여주고 있고, HREM 방법에 의해 새로이 구한 RaVel (Radmilovic et al., 1999) 모델과는 전혀 맞지않음이 판명되었다.

비고용 V-Cu계 MA합금의 중성자 및 X선 회절에 의한 상분석 (Phase Analysis of Immiscible V-Cu MA Powders by Neutron and X-ray Diffraction)

  • 이충효;조재문;이상진;김지순
    • 한국재료학회지
    • /
    • 제14권5호
    • /
    • pp.348-352
    • /
    • 2004
  • The mechanical alloying (MA) effect in immiscible V-Cu system with positive heat of mixing was studied by not only the neutron and X-ray diffraction but also the analysis of DSC spectra. The total energy, ΔHt accumulated during MA for the mixture of $V_{50}$ $Cu_{50}$ / powders increased with milling time and approached the saturation value of 14 kJ/mol after 120 h of milling. It can be seen that the free energy difference between the amorphous phase and the pure V and Cu powders with an atomic ratio 5:5 is estimated to be 11 kJ/mol by Miedema et al. This is thermodynamically taken as one of the evidences for the amorphization. The structural changes of V-Cu MA powders were characterized by the X-ray diffraction and neutron diffraction. We take a full advantage of a negligibly small scattering length of the V atom in the neutron diffraction measurement. The neutron diffraction data definitely indicate that the amorphization proceeds gradually but incompletely even after 120 h of MA and bcc-Cu Bragg peaks appears after 60 h of MA.

기계적 합금화한 $\sigma$-VFe합금의 중성자 및 X선 회절에 의한 상분석 (Phase Analysis of Mechanically Alloyed $\sigma$-VFe Alloy Powders by Neutron and X-ray Diffraction)

  • 이충효;조재문;이상진;심해섭;이창희
    • 한국재료학회지
    • /
    • 제11권8호
    • /
    • pp.664-664
    • /
    • 2001
  • $\sigma$-VFe 금속간화합물에 대한 기계적 합금화(MA) 효과를 중성자 및 X선 회절법으로 조사하였다. MA 분말의 구조분석은 X선 회절(Cu-K$\alpha$) 린 중성자회절(HRPD, λ=1.835$\AA$)을 이용하여 행하였다. $\sigma$-VFe화합물의 MA시 큰 구조변화가 관찰되었으며, MA 60시간의 경우 Fe-Fe 훤자분포는 unit cell에 30개의 원자를 포함하고 있는 $\sigma$상의 tetragonal구조에서 $120^{\circ}C$이상에서 안정하게 존재하는 $\alpha$-(V,Fe) 고용체의 bcc 구조로 상변화함을 알 수 있었다. 또한 $\alpha$-VFe 화합물에 대한 중성자 및 X선 회절패턴의 비교분석을 행하였으며 그 결과 $\sigma$상이 가지는 화학적 규칙성에 기인하는 (101)과 (111) 회절 피크가 중성자 회절에서 뚜렷하게 관찰됨을 알 수 있었다.

Analysis on Design and Fabrication of High-diffraction-efficiency Multilayer Dielectric Gratings

  • Cho, Hyun-Ju;Lee, Kwang-Hyun;Kim, Sang-In;Lee, Jung-Hwan;Kim, Hyun-Tae;Kim, Won-Sik;Kim, Dong Hwan;Lee, Yong-Soo;Kim, Seoyoung;Kim, Tae Young;Hwangbo, Chang Kwon
    • Current Optics and Photonics
    • /
    • 제2권2호
    • /
    • pp.125-133
    • /
    • 2018
  • We report an in-depth analysis of the design and fabrication of multilayer dielectric (MLD) diffraction gratings for spectral beam combining at a wavelength of 1055 nm. The design involves a near-Littrow grating and a modal analysis for high diffraction efficiency. A range of wavelengths, grating periods, and angles of incidence were examined for the near-Littrow grating, for the $0^{th}$ and $-1^{st}$ diffraction orders only. A modal method was then used to investigate the effect of the duty cycle on the effective indices of the grating modes, and the depth of the grating was determined for only the $-1^{st}$-order diffraction. The design parameters of the grating and the matching layer thickness between grating and MLD reflector were refined for high diffraction efficiency, using the finite-difference time-domain (FDTD) method. A high reflector was deposited by electron-beam evaporation, and a grating structure was fabricated by photolithography and reactive-ion etching. The diffraction efficiency and laser-induced damage threshold of the fabricated MLD diffraction gratings were measured, and the diffraction efficiency was compared with the design's value.

X-Ray Diffraction Analysis of Various Calcium Silicate-Based Materials

  • An, So-Youn;Lee, Myung-Jin;Shim, Youn-Soo
    • 치위생과학회지
    • /
    • 제22권3호
    • /
    • pp.191-198
    • /
    • 2022
  • Background: The purpose of this study was to evaluate the composition of the crystal phases of various calcium silicate-based materials (CSMs): ProRoot white MTA (mineral trioxide aggregate) (WMTA), Ortho MTA (OM), Endocem MTA (EM), Retro MTA (RM), Endocem Zr (EN-Z), BiodentineTM (BD), EZ-sealTM (EZ), and OrthoMTA III (OM3). Methods: In a sample holder, 5 g of the powder sample was placed and the top surface of the material was packed flat using a sterilized glass slide. The prepared slides were mounted on an X-ray diffraction (XRD) instrument (D8 Advance; Bruker AXS GmbH, Germany). The X-ray beam 2θ angle range was set at 10~90° and scanned at 1.2° per minute. The Cu X-ray source set to operate at 40 kV and 40 mA in the continuous mode. The peaks in the diffraction pattern of each sample were analyzed using the software Diffrac (version 2.1). Then, the peaks were compared and matched with those of standard materials in the corresponding Powder Diffraction File (PDF-2, JCPDS International Center for Diffraction Data). A powder samples of the materials were analyzed using XRD and the peaks in diffraction pattern were compared to the Powder Diffraction File data. Results: Eight CSMs showed a similar diffraction pattern because their main component was calcium silicate. Eight CSMs showed similar diffraction peaks because calcium silicate was their main component. Two components were observed to have been added as radiopacifiers: bismuth oxide was detected in WMTA, OM, and EM while zirconium oxide was detected in RM, EN-Z, BD, EZ, and OM3. Unusual patterns were detected for the new material, OM3, which had strong peaks at low angles. Conclusion: It was caused by the presence of Brushite, which is believed to have resulted in crystal growth in a particular direction for a specific purpose.

무편광 유전체 다층박막 회절격자의 효율 보정 (Diffraction-efficiency Correction of Polarization-independent Multilayer Dielectric Gratings)

  • 조현주;김관하;김동환;이용수;김상인;조준용;김현태
    • 한국광학회지
    • /
    • 제33권1호
    • /
    • pp.22-27
    • /
    • 2022
  • 격자의 구조가 간단하고 격자의 대조비가 낮은 SBC 시스템 구성을 위한 무편광 유전체 다층박막 회절격자를 제작하였다. 제작된 박막의 굴절률과 두께 오차로 인하여, 제작된 회절격자의 회절 효율은 설계보다 낮은 값을 나타내었다. 오차를 발생시킨 원인을 분석하고, 제작된 회절격자 위에 추가의 코팅을 통하여 회절 효율 보정이 가능함을 시뮬레이션을 통하여 확인하였다. 시뮬레이션 결과를 확인하기 위하여 제작된 회절격자 위에 Ta2O5 추가층을 제작하고 회절격자를 측정한 결과 회절 효율 보상이 이루어졌으며, 최고 91.7%의 무편광 회절 효율을 얻었다.

중성자 회절에 의한 산화우라늄 핵연료 분말의 결정크기 측정 (Crystallite Size Measurement of Uranium Oxide Fuel Powders by Neutron Diffraction)

  • 류호진;강권호;문제선;송기찬;최용남
    • 한국분말재료학회지
    • /
    • 제10권5호
    • /
    • pp.318-324
    • /
    • 2003
  • The nano-scale crystallite sizes of uranium oxide powders in simulated spent fuel were measured by the neutron diffraction line broadening method in order to analyze the sintering behavior of the dry process fuel. The mixed $UO_2$ and fission product powders were dry-milled in an attritor for 30, 60, and 120 min. The diffraction patterns of the powders were obtained by using the high resolution powder diffractometer in the HANARO research reactor. Diffraction line broadening due to crystallite size was measured using various techniques such as the Stokes' deconvolution, profile fitting methods using Cauchy function, Gaussian function, and Voigt function, and the Warren-Averbach method. The non-uniform strain, stacking fault and twin probability were measured using the information from the diffraction pattern. The realistic crystallite size could be obtained after separation of the contribution from the non-uniform strain, stacking fault and twin.