• Title/Summary/Keyword: Differential sensing

Search Result 174, Processing Time 0.02 seconds

Implementation of Optimized 1st-Order Masking AES Algorithm Against Side-Channel-Analysis (부채널 분석 대응을 위한 1차 마스킹 AES 알고리즘 최적화 구현)

  • Kim, Kyung Ho;Seo, Hwa Jeong
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.8 no.9
    • /
    • pp.225-230
    • /
    • 2019
  • Recently, with the development of Internet technology, various encryption algorithms have been adopted to protect the sensing data measured by hardware devices. The Advanced Encryption Standard (AES), the most widely used encryption algorithm in the world, is also used in many devices with strong security. However, it has been found that the AES algorithm is vulnerable to side channel analysis attacks such as Differential Power Analysis (DPA) and Correlation Power Analysis (CPA). In this paper, we present a software optimization implementation technique of the AES algorithm applying the most widely known masking technique among side channel analysis attack methods.

Differential Transmission Spectra of Terahertz Metamaterial Resonances for Sensing Microorganisms (미생물에 의한 테라헤르츠 메타물질의 공명주파수 변화)

  • Park, S.J.;Ahn, Y.H.
    • Korean Journal of Optics and Photonics
    • /
    • v.27 no.6
    • /
    • pp.229-232
    • /
    • 2016
  • Metamaterials operating in the terahertz frequency range show promising potential for use in highly sensitive microbial sensors that are capable of effectively detecting microorganisms in the ambient environment. We were able to detect extremely small numbers of microorganisms by measuring the differential transmission spectra (DTS) of the metamaterial resonances. This was possible because their sizes are on the same scale as the microgaps of the terahertz metamaterials. DTS depend critically on the number of microorganisms placed in the gap area, and their dielectric constant. In addition, these metamaterial microbial sensors are reusable, because the microorganisms can be completely removed by fungicide solution. Finite-difference time-domain simulations successfully reproduce our experimental data.

The 4bit Cell Array Structure of PoRAM and A Sensing Method for Drive this Structure (PoRAM의 4bit 셀 어레이 구조와 이를 동작시키기 위한 센싱 기법)

  • Kim, Jung-Ha;Lee, Sang-Sun
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.6 s.360
    • /
    • pp.8-18
    • /
    • 2007
  • In this paper, a 4bit cell way structure of PoRAM and the sensing method to drive this structure are researched. PoRAM has a different operation from existing SRAM and DRAM. The operation is that when certain voltage is applied between top electrode and bottom electrode of PoRAM device we can classify the cell state by measuring cell current which is made by changing resistance of the cell. In the decoder selected by new-addressing method in the cell array, the row decoder is selected "High" and the column decoder is selected "Low" then certain current will flow to the bit-line. Because this current is detect, in order to make large enough current, the voltage sense amplifier is used. In this case, usually, 1-stage differential amplifier using current mirror is used. Furthermore, the detected value at the cell is current, so a diode connected NMOSFET, that is, a device resistor is used at the input port of the differential amplifier to converter current into voltage. Using this differential amplifier, we can classify the cell states, erase mode is "Low" and write mode is "High", by comparing the input value, Vin, that is a product of current value multiplied by resistor value with a reference voltage, Vref.

Application of 2-pass DInSAR to Improve DEM Precision (DEM 정밀도 향상을 위한 2-pass DInSAR 방법의 적용)

  • 윤근원;김상완;민경덕;원중선
    • Korean Journal of Remote Sensing
    • /
    • v.17 no.3
    • /
    • pp.231-242
    • /
    • 2001
  • In 2-pass differential SAR interferometry(DInSAR), the topographic phase signature can be removed by using a digital elevation model(DEM) to isolate the contribution of deformation from interferometric phase. This method has an advantage of no unwrapping process, but applicability is limited by precision of the DEM used. The residual phase in 2-pass differential interferogram accounts for error of DEM used in the processing provided that no actual deformation exits. The objective of this paper is a preliminary study to improve DEM precision using low precision DEM and 2-pass DInSAR technique, and we applied the 2-pass DInSAR technique to Asan area. ERS-1/2 tandem complex images and DTED level 0 DEM were used for DInSAR, and the precision of resulting DEM was estimated by a 1:25,000 digital map. The input DEM can be improved by simply adding the DInSAR output to the original low precision DEM. The absolute altitude error of the improved DEM is 9.7m, which is about the half to that of the original DTED level 0 data. And absolute altitude error of the improved DEM is better than that from InSAR technique, 15.8m. This approach has an advantage over the InSAR technique in efficiently reducing layover effects over steep slope region. This study demonstrates that 2-pass DInSAR can also be used to improve DEM precision.

Evaluation of Retrieval Accuracy of NO2 Column Density from Pandora Raw Data According to Wavelength Range and Absorption Cross-section Using DOAS Method (Pandora 원시자료로부터 차등흡수분광법을 이용하여 이산화질소 칼럼 농도 산출 시 파장 구간 및 흡수단면적에 따른 산출 정확도 평가)

  • Kim, Serin;Kim, Daewon;Lee, Hanlim
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.2
    • /
    • pp.215-222
    • /
    • 2022
  • In this study, the effect of wavelength range and absorption cross-section used to retrieve nitrogen dioxide (NO2) vertical column density (VCD) from Pandora was analyzed using Differential Optical Absorption Spectroscopy (DOAS). During the GEMS Map of the Air Pollution (GMAP) 2020 campaign, data from direct sunlight observation with Pandora instrument in Seosan was used, and NO2 VCD was retrieved under four conditions. The average NO2 VCD under the four conditions ranged from 1.22×1016~1.38×1016 molec. cm-2, with a maximum difference of 0.16×1016 molec. cm-2 between each condition. The fitting error averaged 3.19~9.59%, showing an error within 10% in all cases, and the RMS was 5.11×10-3~7.16×10-3 molec. cm-2. The retrieved NO2 VCD using 4 conditions shows a slope in the range of 0.98 to 1.09 and correlation of 0.96 to 0.98 in comparison with Pandonia Global Network (PGN).

Investigation of Absorption Cross-Section Effects on the Formaldehyde Column Density Retrieval from Direct Sun Measurement (태양 직달광 관측 자료로부터 포름알데히드 연직 농도 산출 시 흡수단면적이 미치는 영향 연구)

  • Gyeong Park;Jeonghyeon Park;Hanlim Lee
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.5_1
    • /
    • pp.551-561
    • /
    • 2023
  • In this study, we investigated the effects of the spectral fitting window and absorption cross-section on the retrieval of the formaldehyde (HCHO) slant column density (SCD) from the direct-sun measurement of pandora spectrometer system using differential optical absorption spectroscopy (DOAS). Pandora Level 1 data observed at Yonsei University in Seoul from October 12 to 31, 2022 were used. The HCHO column density was retrieved under eight ranges including the spectral fitting window used in the Second Cabauw Intercomparison campaign for Nitrogen Dioxide measuring Instruments (CINDI-2) and seven types of absorption cross-section composition. The spectral fitting window was selected from 336.5 to 359.0 nm with minimum residual and HCHO SCD error. When the nitrogen dioxide (NO2) absorption cross-section at 220 K was added to the cross-section composition used in the CINDI-2 campaign among seven types, the residual and HCHO SCD error were the smallest and the HCHO column density wasstably retrieved. The average HCHO SCD with the highest retrieval accuracy and the values retrieved under other conditions differed from a minimum of 4% to a maximum of 40%.

Experimental Study on Temperature Dependence of Nitrate Sensing using an ISE-based On-site Water Monitoring System

  • Jung, Dae-Hyun;Kim, Dong-Wook;Cho, Woo Jae;Kim, Hak-Jin
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.122-122
    • /
    • 2017
  • Recently, environmental problems have become an area of growing interests. In-situ monitoring of water quality is fundamental to most environmental applications. The accurate measurement of nitrate concentrations is fundamental to understanding biogeochemistry in aquatic ecosystems. Several studies have reported that one of the most feasible methods to measure nitrate concentration is the use of Ion Selective-electrodes (ISEs). The ISE application to water monitoring has several advantages, such as direct measurement methodology, high sensitivity, wide measurement range, low cost, and portability. However, the ISE methods may yield inconsistent results where there was a difference in temperature between the calibration and measurement solutions, which is associated with the temperature dependence of ionic activity coefficients in solution. In this study, to investigate the potential of using the combination of a temperature sensor and nitrate ISEs for minimizing the effect of temperature on real-time nitrate sensing in natural water, a prototype of on-site water monitoring system was built, mainly consisting of a sensor chamber, an array of 3 ISEs, an waterproof temperature sensor, an automatic sampling system, and an arduino MCU board. The analog signals of ISEs were obtained using the second-order Sallen-key filter for performing voltage following, differential amplification, and low pass filtering. The performance test of the developed water nitrate sensing system was conducted in a monitoring station of drinking water located in Jeongseon, Kangwon. A temperature compensation method based on two-point normalization was proposed, which incorporated the determination of temperature coefficient values using regression equations relating solution temperature and electrode signal determined in our previous studies.

  • PDF

Design of High-Speed EEPROM IP Based on a BCD Process (BCD 공정기반의 고속 EEPROM IP 설계)

  • Jin, RiJun;Park, Heon;Ha, Pan-Bong;Kim, Young-Hee
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.10 no.5
    • /
    • pp.455-461
    • /
    • 2017
  • In this paper, a local DL (Data Line) sensing method with smaller parasitic capacitance replacing the previous distributed DB sensing method with large parasitic capacitance is proposed to reduce the time to transfer BL (Bit Line) voltage to DL in the read mode. A new BL switching circuit turning on NMOS switches faster is also proposed. Furthermore, the access time is reduced to 35.63ns from 40ns in the read mode and thus meets the requirement since BL node voltage is clamped at 0.6V by a DL clamping circuit instead of precharging the node to VDD-VT and a differential amplifier are used. The layout size of the designed 512Kb EEPROM memory IP based on a $0.13{\mu}m$ BCD is $923.4{\mu}m{\times}1150.96{\mu}m$ ($=1.063mm^2$).

RNAseq-based Transcriptome Analysis of Burkholderia glumae Quorum Sensing

  • Kim, Sunyoung;Park, Jungwook;Kim, Ji Hyeon;Lee, Jongyun;Bang, Bongjun;Hwang, Ingyu;Seo, Young-Su
    • The Plant Pathology Journal
    • /
    • v.29 no.3
    • /
    • pp.249-259
    • /
    • 2013
  • Burkholderia glumae causes rice grain rot and sheath rot by producing toxoflavin, the expression of which is regulated by quorum sensing (QS). The QS systems of B. glumae rely on N-octanoyl homoserine lactone, synthesized by TofI and its cognate receptor TofR, to activate the genes for toxoflavin biosynthesis and an IclR-type transcriptional regulator gene, qsmR. To understand genome-wide transcriptional profiling of QS signaling, we employed RNAseq of the wild-type B. glumae BGR1 with QS-defective mutant, BGS2 (BGR1 tofI::${\Omega}$) and QS-dependent transcriptional regulator mutant, BGS9 (BGR1 qsmR::${\Omega}$). A comparison of gene expression profiling among the wild-type BGR1 and the two mutants before and after QS onset as well as gene ontology (GO) enrichment analysis from differential expressed genes (DEGs) revealed that genes involved in motility were highly enriched in TofI-dependent DEGs, whereas genes for transport and DNA polymerase were highly enriched in QsmR-dependent DEGs. Further, a combination of pathways with these DEGs and phenotype analysis of mutants pointed to a couple of metabolic processes, which are dependent on QS in B. glumae, that were directly or indirectly related with bacterial motility. The consistency of observed bacterial phenotypes with GOs or metabolic pathways in QS-regulated genes implied that integration RNAseq with GO enrichment or pathways would be useful to study bacterial physiology and phenotypes.

Respiratory Air Flow Transducer Applicable to Cardiopulmonary Resuscitation Procedure (인공심폐소생술에 활용 가능한 호흡기류센서)

  • Kim, Kyung-Ah;Lee, In-Kwang;Lee, You-Mi;Yu, Hee;Kim, Young-Il;Han, Sang-Hyun;Cha, Eun-Jong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.6
    • /
    • pp.833-839
    • /
    • 2013
  • Cardiopulmonary resuscitation (CPR) is performed by thoracic compression and artificial ventilation for the patient under emergent situation to maintain at least the minimum level of respiration and blood circulation for life survival. Good quality CPR requires monitoring respiration, however, traditional respiratory air flow transducers cannot be used because the transducer elements are facing the whole area perpendicular to the flow axis. The present study developed a new air flow transducer conveniently applicable to CPR. Specially designed "sensing rod" samples the air velocity at 3 different locations of the flow cross-section, then transforms into average dynamic pressure by the Bernoulli's law. The symmetric structure of the sensing holes of the sensing rod enables bi-directional measurement simply by taking the difference in pressure by a commercial differential pressure transducer. Both inspiratory and expiratory flows were obtained with symmetric measurement characteristics. Quadratic curve fitting provided excellent calibration formula with a correlation coefficient>0.999 (P<0.0001) and the mean relative error<1%. The present results can be usefully applied to accurately monitor the air flow rate during CPR.