• Title/Summary/Keyword: Differential pressure

Search Result 757, Processing Time 0.026 seconds

Reliability Assessment Criteria of Differential Pressure Sensor for DPF (자동차용 DPF 차압센서의 신뢰성 평가기준)

  • Chung, Wooyoung;Min, Joonwon;Park, Dongkyu;Choi, Jungwoon;Choi, Wooseok;Kim, Sidong
    • Journal of Applied Reliability
    • /
    • v.15 no.1
    • /
    • pp.67-75
    • /
    • 2015
  • Differential pressure sensor for DPF (Diesel Particulate Filter) is the important part of a automobile exhaust system. This device measures the pressure of before DOC and after DPF to determine whether the DPF regenerate. In this paper reliability assessment criteria for DPF differential pressure sensor are established on terms of quality calcification test and lifetime test. The former quality certification test comprises general performance test and environmental test. Items which pass the test undergo lifetime test which guarantees the extent of mean lifetime with certain confidence.

Numerical analysis of the differential pressure venturi-cone flowmeter (차압식 벤튜리콘 유량계에 대한 유동해석)

  • 윤준용;맹주성;이정원
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.6
    • /
    • pp.714-720
    • /
    • 1998
  • The differential pressure venturi-cone flowmeter is an advanced flowmeter which has many advantages such as wide range of measurement, high accuracy, excellent flow turn-down ratio, low headless, short installation pipe length requirement, and etc. Like other differential pressure flowmeters, the venturi-cone flowmeter uses the law of energy conservation, but its shape and position make it perform better than others. The cone acts as its own flow conditioner and mixer, fully conditioning and mixing the flow prior to measurement. For the analysis, we used Reynolds-averaged Wavier-Stokes equations and k-$\omega$ turbulence model. The equations were fully transformed into the computational domain, the pressure-velocity coupling was made through SIMPLER algorithm, and the equations were discretized using finite analytic solutions of the liberalized equations(Finite Analytic Method). To control the separation phenomenon on the cone surface, we proposed a new shape of cone, and analyzed the flowfield in the new flowmeter system, and found the improvement on the performance of the new cone flowmeter.

  • PDF

A Study on the MR Cylinder with Built-in alves (밸브 내장형 MR 실린더에 관한 연구)

  • Song Joo-Young;Ahn Kyoung-Kwan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.7 s.172
    • /
    • pp.130-136
    • /
    • 2005
  • A new MR cylinder with built-in valves using MR fluid (MR valve) is suggested and fabricated fur fluid control systems. The MR fluid is a newly developed functional fluid whose obvious viscosity is controlled by the applied magnetic field intensity. The MR cylinder is composed of cylinder with small clearance and piston with electromagnet. The differential pressure is controlled by the applied magnetic field intensity. It has the characteristics of simple, compact and reliable structure. The size of MR cylinder and piston has $\varphi30mm\times300mm$ and $\varphi28.5mm\times120mm$ in face size, respectively and 0.8mm in gap length. Through experiments, it was found that the differential pressure is controlled by the applied magnetic field intensity under little influence of the flow rate, which corresponds to a pressure control valve. The differential pressure of 0.47MPa was obtained with the input current of 1.5A. The rising time was 2.3s in step response of a manipulator using the MR cylinder. The effectiveness of the MR cylinder was also demonstrated through the position control.

A Study on Flow Rate Characteristics of a Triangular Separate Bar Differential Pressure Flow Meter according to the Variation of Gas Flow Temperature (유동 가스 온도 변화에 따른 삼각 분리 막대형 차압 유량계 유량 특성에 관한 연구)

  • Kim, Kwang-Il;Yoo, Won-Yuel;Lee, Choong-Hoon
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.4
    • /
    • pp.89-94
    • /
    • 2008
  • Differential pressure flow meters which have a shape of triangular separate bar(TSB) were tested for investigating the flow rate characteristics of the flow meters with varying the temperature of the gas flow. Three kinds of the triangular separate bar flow meters whose aerodynamic angles are different one another are used. The mass flow rate of the flow meters are evaluated using a non-dimensional parameter which includes the gas temperature, exhaust gas pressure and differential pressure at the flow meters, and atmospheric pressure. A burner system which is similar to gas turbine was used for raising the gas flow temperature. The burner system was operated with varying the air/fuel ratio by controlling both the fuel injection rate from the fuel nozzle and air flow rate from a blower. An empirical correlation between the mass flow rate at the TSB flow meter and the non-dimensional parameter was obtained. The empirical correlation showed linear relationship between the mass flow rate and the non-dimensional parameter H. Also, the mass flow rate characteristics at the TSB flow meter was affected by the gas temperature.

A Study on Reduction of Cavitation with Orifice on High Differential Pressure Control Butterfly Valve (오리피스를 이용한 고차압 제어 버터플라이 밸브의 캐비테이션 저감에 관한 연구)

  • Lee, Sang-Beom
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.1
    • /
    • pp.131-139
    • /
    • 2022
  • The exchange of goods over the sea is a situation in which the amount of trade between countries is gradually increasing. In order to maintain the optimal operating condition, the ship maintains stability and optimal operating conditions by inserting or withdrawing ballast water from the ballast tank according to the loading condition of cargo capacity is also increasing. Control valves play an important role in controlling fluid flow in these pipes. When the flow rate is controlled using a control valve, problems such as cavitation, flashing, and suffocating flow may occur due to high differential pressure, and in particular, damage to valves and pipes due to cavitation is a major problem. Therefore, in this study, the cavitation phenomenon is reduced by installing orifices at the front and rear ends of the high differential pressure control butterfly valve to reduce the sudden pressure drop at the limiting part of the butterfly valve step by step. The flow coefficient according to the shape of the orifice, the degree of cavitation occurrence, and the correlation were analyzed using a CFD(Cumputational Fluid Dynamics), and an optimal orifice design for reducing cavitation is derived.

The Effect of In-Outlet Differential Pressure on a Valve Body Stress and Deformation by the Blow-by Gas Flow Characteristic in the PCV valve for Automobile (자동차용 PCV밸브내 유통특성에 의한 밸브응력 및 변형에 미치는 입출구 차압의 영향)

  • Kwon Oh-Heon;Lee Yeon-Won;Song Sang-Min;Lee Jong-Hoon;Kang Ji-Woong
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.1 s.69
    • /
    • pp.36-41
    • /
    • 2005
  • PCV(Positive Crankcase Ventilation) valve acts as a flow control valve to get a re-combustion of blow-by gas by having it flow from a crankcase to an inlet manifold suction tube. The blow-by gas of the crankcase should be eliminated or taken properly because it cause corrosion to critical parts, and contributes to increase crankcase pressure that can cause a drop in efficiency. The excessive stress and strain on the PCV valve that remove these harmful gas would be bring the difficult on the flow rate control and failure of the valve. Those condition inevitably induce the accident. Therefore, this study purpose is FEM evaluation of the stresses and deformation in the X3 PCV model according to the change of the differential pressure between inlet and outlet. From results, the maximum equivalent stresses increased linearly according to the increase of the differential pressure at the about 50mm from the inlet position and were under the yield strength of the valve. And the deformations were relatively small regardless of the in-outlet differential pressure variation.

Experimental Study for Performance Evaluation of Gate Valve (게이트밸브의 성능평가를 위한 실험적 연구)

  • Cho, Tack-Dong;Yang, Sang-Min
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.10
    • /
    • pp.884-888
    • /
    • 2007
  • It is necessary to evaluate periodically the performance of the AOV(air-operated valve) which is used for controlling flow and pressure in nuclear power plant. The required thrust for actuating valve and available thrust of actuator are calculated with conditions of flow through a valve in this study and operating performance is analyzed through comparing two thrusts. In general, differential pressure is increased according to increase the flow rate and differential pressure affects the required thrust of valve. We found the fact that it is possible not to close the valve perfectly because required thrust becomes bigger than available thrust of actuator.

Numerical Analysis of the Differential Pressure Venturi-cone Flowmeter (차압식 Venturi-cone 유량계에 대한 유동해석)

  • Yoon J. Y.;Maeng J. S.;Lee J. W.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.143-148
    • /
    • 1997
  • Differential pressure Venturi cone flowmeter is an advanced flowmeter which has many advantages such as wide range of measurement, high accuracy, excellent flow turndown ratio, low headless, and short installation pipe length requirement, etc. Like other differential pressure flowmeter, Venturi cone flowmeter uses the law of energy conservation, but its shape and position make it perform better than others. The cone acts as its own flow conditioner and mixer, fully conditioning and mixing the flow prior to measurement. For the analysis, we use Reynolds-averaged Navier-Stokes equations and $k-{\omega}$ turbulence model. The equations are fully trans-formed in the computational coordinates, the pressure-velocity coupling is made through SIMPLER algorithm, and the equations are discretized using analytic solutions of the linearized equations(Finite Analytic Method). At the end of the paper, using the result of analysis, We propose a new shape of cone with the hope of drag reduction and high performance.

  • PDF

The Characteristic Change of Pressure and Differential Transmitter due to a Rapid Change of Ambient Temperature (주위 온도의 급격한 변화에 따른 압력 및 차압 전송기의 특성 변화)

  • Chung, Jong-Tae;Ha, Young-Cheol;Lee, Cheol-Gu;Her, Jae-Young
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.321-326
    • /
    • 2004
  • The pressure and differential pressure(DP) transmitters are used for gas flow rate calculation on the orifice gas metering system. On site, the pressure and DP transmitters are installed in a shelter to diminish the affects of environmental change such as an ambient temperature. But there has been an argument about the effectiveness of the shelter and this brought up the necessity to verify the affects of ambient temperature. These experiments were performed to verify the ambient temperature effects as observing the output of transmitters when the ambient temperature were changed from $-30^{\circ}C$ to $50^{\circ}C$. The results showed that the most of transmitters were operated in the spec range of performance criteria presented by manufacturer but the rapid change of ambient temperature could cause the larger measurement error for the DP transmitter of low span than others. Therefore the pressure and DP transmitters need to be operated and controlled within the proper range of ambient temperature.

  • PDF