• Title/Summary/Keyword: Different metal

Search Result 3,355, Processing Time 0.03 seconds

Porous Metals of Northwest Institute for Non-ferrous Metal Research

  • Huiping, Tang;Jichang, Liao;Jilei, Zhu
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09b
    • /
    • pp.903-904
    • /
    • 2006
  • In recent years, the research in porous metal got rapid development in China, especial in Northwest Institute for Non-ferrous Metal Research (NIN). Many porous metals with different raw material and different shapes were developed, which successfully employed in many fields. We believe we will earn more rapid development in the future.

  • PDF

Comparison of the marginal fit of POM restorations with different thickness of metal copings (코핑 두께의 차이에 따른 POM 보철물의 변연적합도 연구)

  • Lim, Hyung-Tek
    • Journal of Technologic Dentistry
    • /
    • v.34 no.2
    • /
    • pp.135-143
    • /
    • 2012
  • Purpose: The purpose of this in vitro study was to compare the marginal fit of POM restorations with 3 different thickness of metal coping. Methods: 2.0mm Occlusal reduction, 1.0mm preparation of axial wall with 6degree taper, and chamfer margin was prepared a maxillary first premolar on dentiform. Duplicate prepared die and, make 30 individual dies with Ni-Cr metal. Make 3 groups of 30 press ceramic on Metal crown with different thickness of metal coping; 10 of 0.1mm, 10 of 0.3mm, 10 of 0.5mm thickness metal coping. The marginal fit of the crowns was evaluated 50 points per 1 crown, around the crown margin circumference under a optical microscope at original magnification ${\times}100$. A 1-way analysis of variance (ANOVA) was used to compare data. Results: The mean marginal discrepancy for POM with 0.1mm metal copings was $72.56{\mu}m$, $67.83{\mu}m$ for 0.3mm metal coping POMs, and $72.56{\mu}m$ for 0.5mm metal coping POM. The 1-way ANOVA showed significant difference among 3 groups. Conclusion: The marginal fit of pressed-on-metal (POMs) was best with 0.3mm thickness of metal coping, fallowing by 0.1mm, and 0.5mm in the order.

A SCANNING ELECTRON MICROSCOPIC STUDY ON THE LABIAL MARGINAL FIT OF METAL CERAMIC CROWNS MADE BY DIFFERENT TECHNIQUES (도재전장주조관의 제작방법에 따른 순측 치경부 변연 적합도에 관한 주사전자현미경적 연구)

  • Yoon, Il-Joong;Chang, Wan-Shik;Yang, Jae-Ho;Lee, Sun-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.24 no.1
    • /
    • pp.151-164
    • /
    • 1986
  • The purpose of this study was to evaluate the marginal fit of metal ceramic crowns made by different techniques. The techniques were metal butt margin technique, platinum foil technique, shoulder powder techniques and wax technique. The latter three techniques were for the fabrication of collarless metal ceramic crowns. Ten crowns were made of each techniques, and marginal fit was evaluated using scanning electron microscope under X200 magnification. The results were as follows. 1. The marginal fit in the descending order were wax technique shoulder powder technique, platinum foil technique and metal butt margin, before cementation, and wax technique, shoulder powder technique, metal butt margin, and platinum foil technique, after cementation. 2. The fit of collarless metal ceramic crowns was comparable to metal ceramic crowns with metal butt margins. 3. There were no statistically significant differences between marginal fit of metal ceramic crowns made by different techniques.

  • PDF

Evaluation of Sequential Extraction Techniques for Selected Heavy Metal Speciation in Contaminated Soils

  • Lee, Jin-Ho;Doolittle, James J.;Oh, Byung-Taek
    • Korean Journal of Environmental Agriculture
    • /
    • v.25 no.3
    • /
    • pp.236-246
    • /
    • 2006
  • In this study, we give insight into questionable results that can be encountered in the conventional sequential extraction of heavy metals (Cd, Cu, and Zn) from soils. Objectives of this study were to determine the extraction variability of exchangeable (EXC)-metals as using six different EXC-extractants commonly accepted, and to investigate selectivity problems with carbonates bound (CAB)-metal fraction, a buffered acetate (1.0 M NaOAc; pH 5.0) extractable-metal fraction, leading to erratic results in especially non-calcareous soils. The contents of EXC-metals were markedly varied with the different extractability of various EXC-metal extractants used. The contents of EXC-Cd fraction were ranged from 2.0 to 74.3% of total Cd content in all of the metal spiked soils studied. The contents of EXC-Zn fraction extracted with the different EXC-extractants were varied with soil types, which were from 0.4 to 3.9% of total Zn in the calcareous soils, from 7.6 to 17.9% in the acidic soil, and from 13.6 to 56.8% in the peat soil. However, the contents of EXC-Cu fraction were relatively similar among the applications of different EXC-meal extractants, 0.2 to 2.1 % of total Cu, in all soils tested. Also, these varied amounts of EXC-metal fractions, especially Cd and Zn, seriously impacted the contents of subsequent metal fractions in the procedure. Furthermore, the CAB-Cd, -Cu, and -Zn fractions extracted by the buffered acetate solution were in critical problem. That is, the buffered acetate solution dissolved not only CAB-metals but also metals that bound or occupied to subsequent fractions, especially OXD-metal fraction, in both calcareous and non-calcareous soils. The erratic results of CAB-fraction also seriously impacted the amounts of subsequent metal fractions. Therefore, the conventional sequential extraction should be reconsidered theoretically and experimentally to quantify the target metal fractions or might be progressively discarded.

Analysis of Planar Metal Plasmon Waveguides

  • Jung, Jae-Hoon
    • Journal of the Semiconductor & Display Technology
    • /
    • v.9 no.2
    • /
    • pp.97-102
    • /
    • 2010
  • Propagation modes of symmetric metal-insulator-metal SPP waveguides are analyzed. Main characteristics of these waveguides such as mode effective index, propagation length, and penetration depths are calculated at the telecom wavelength for different layer thickness. We adopt Au, Al as a metal material and air, glass as a dielectric material and obtain different optical characteristics. The surface plasmon characteristics in this paper provide a numerical insight for designing nanostructure metal plasmon waveguide.

Surface Transition by Solvent Washing Effects and Biological Properties of Metal Treated Activated Carbons

  • Oh, Won-Chun
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.5
    • /
    • pp.639-646
    • /
    • 2004
  • Metal treated activated carbons are prepared using various metals. Adsorption behaviors, morphologies, as well as antibacterial effects of metal treated samples are compared before and after solvent washing. Adsorption isotherms are used to characterize the porous structure of metal treated activated carbons before and after the solvent washing with acetone or ethyl alcohol. From these data, it is noticed that the changes in physicochemical properties of metal treated activated carbons depend on the solvents employed. Similar results are observed from BET data obtained from nitrogen adsorption isotherms. From scanning electron microscopy (SEM) studies, the changes in shape and size of metal particles are observed after the samples are washed with solvents. These changes result in different blocking effects, which, in turn, affect the adsorption behavior of metal treated activated carbons. X-ray diffraction (XRD) patterns of the samples treated with different metals are different each other. High intense sharp peaks attributed to metals are observed from silver treated samples, while the peaks are not observed from copper treated samples. To compare thermodynamic behavior of metal treated activated carbons washed with different type of solvents, differential scanning calorimetric (DSC) analysis is carried out. The analysis shows similar endothermic curves for all of the samples. Finally, antibacterial effects of metal treated activated carbon against Escherichia coli are discussed. Comparing the effects among the metals employed, highest effects are obtained from Cd, while lowest effects are obtained from Cu. Antibacterial activity becomes higher with the increase of the amount of metals treated, Optimum concentrations of metals to treat activated carbons, obtained from a shake flask test, are known to be 0.4, 0.1, and 0.6 moles for Ag, Cd, and Cu, respectively.

A study on the depositional wear between different metals (이종 금속간의 용착마모에 관한 연구)

  • 신문교;이우환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.74-88
    • /
    • 1985
  • The wear becomes the most complicated cause of making various machineries short lives. In the studies by many scholors so far, the accurate and perfect methods to eliminate it completely are not found yet owing to many affected factors. On this view point of Depositional Wear, the wear test with seven different specimens from the part of frequent usage of which are carbon steel, nickel, copper, aluminum, zinc, lead and tin was attempted to make clear the relation between the wear of different metals and their melting point, crystal structure, sliding speed, load and lattice factors. The results of this study are summerized as follows; 1) Worn amount of each metal is maximum when each metal is same quality. 2) The easier becomes the the formation of solid solution in the course of friction proceeding, the more it results in worn amount of each metal. 3) The samer is each metal in crystal structure as well as lattice factor, the more it results in worn amount of each metal. These results might be of use in designing machineries, selecting materials and operating machineries.

  • PDF

C-V Characteristics of The MOS Devices by Using different Gate Metals (게이트 금속 변화에 의한 MOS 소자의 C-V 특성)

  • 최현식;서용진;유석빈;장의구
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1988.10a
    • /
    • pp.95-97
    • /
    • 1988
  • The instability of MOS devices is mainly caused by the oxide charges, and as the need to develop the gate metal grows researches for various new metal gate have been performed, and in these researches, the difference work function existing between the metal and the semiconductor should be considered. Here int his paper, the device is made by the sputtering and the LPCVD method using pure Al, compound metal. poly-si, as a gate metal, the result of the research was shown that the work function difference from using different gate metals effects on the flatband voltage shift. This means we can infer that the threshold voltage adjustment is possible by using different gate metals and this whole mechanism makes the devices behavior more stable.

  • PDF

AN EXPERIMENTAL STUDY ON THE CERVICAL MARGIN FITNESS IN THE COLLARLESS METAL CERAMIC CROWNS FORMED BY DIFFERENT TECHNIQUES (Collarless도재소부전장금관의 제작방법에 따른 치경부 변연적합도에 관한 실험적 연구)

  • Lee, Jae-Hyeuk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.28 no.1
    • /
    • pp.203-216
    • /
    • 1990
  • The purpose of this study was to evaluate the cervical margin fitness in the collarless metal ceramic crowns formed by different techniques. Specimens were divided as follows : the metal ceramic crowns with metal butt margin as group I, the collarless metal ceramic crowns formed with resin binder technique as group II, and the collarless metal ceramic crowns formed with shoulder powder mixed with phosphate-bonded investment liquids on a refractory die as group III. Each group was made of five specimens, and their marginal fitness on each epoxy die was evaluated under scanning electron microscope of x200 magnification at three measuring points : mesial, central, distal. The following results were obtained. 1. The metal ceramic crowns with metal butt margin exhibited significantly better marginal fitness than the collarless metal ceramic crowns. The marginal fitness in descending order was group I, III, II. 2. The collarless metal ceramic crown formed with resin binder technique had the worst marginal fitness & showed cervical color variation and dermacation between the corrected porcelain & the dentin porcelain. 3. The collarless metal ceramic crowns formed with shoulder powder mixed with phosphate-bonded investment liquids on a refractory die exhibited significantly better marginal fitness & sharper marginal configuration than the other collarless group.

  • PDF

Availability of Heavy Metals in Soils with Different Characteristics and Controversial Points for Analytical Methods of Soil Contamination in Korea (토양특성별 중금속 유효도와 토양오염 평가방법의 개선점)

  • Jung, Goo-Bok;Kim, Won-Il;Lee, Jong-Sik;Shin, Joung-Du;Kim, Jin-Ho;Yun, Sun-Gang
    • Korean Journal of Environmental Agriculture
    • /
    • v.24 no.2
    • /
    • pp.106-116
    • /
    • 2005
  • This experiment was conducted to investigate available extraction capacity and potential mobility of heavy metal according to the distribution property and contamination level of heavy metals in soils and to suggest a reform measure of soil environment assessment methodology applied with soil quality and the official soil heavy metal test methods in domestic and foreign countries. The soils were collected from the natural forest paddy with long-term application of same type fertilizer, and paddies near metal mine and industrial complex. The post-treatment methods of soil were partial extraction, acid digestion and sequential extraction methods. For the heavy metal contents with different soil properties, it was shown that their natural forest and paddy soil were slightly low and similar to the general paddy soil, while their paddies near metal mine and industrial complex were higher than the standard level of Soil Environment Protection Act. Heavy metal concentrations in the soils with different soil properties had difference between $HNO_3\;and\;HNO_3+HCl$ extractant by US-EPA 3051a method. There were highly significant positive relationships in both two methods. It was appeared that the higher extractable concentration ratio with 0.1N-HCl to total heavy metal content with $HNO_3+HCl$ extractant the greater total heavy metal content. There were highly significant positive correlationship between total heavy metal content and extractable content with 0.1N-HCl. For extractable capacity of soil extractable solution compared to the total heavy metal content it was appeared that it extractable method with 0.1N-HCl was higher than those with EDTA and DTPA. In extractable ratio with 0.1N-HCl in the contaminated paddy soils near mine and industrial complex, it was shown that the lower soil pH, the higher total heavy metal content. The order of a potential mobility coefficient by distribution of heavy metal content with ie different typies in the soil was Cd>Ni>Zn>Cu>Pb. It could be known that contamination characteristics of heavy metals with different types of soils were affected by different heavy metal components, contamination degree and soil chemical properties, and heavy metal concentration with different extractable methods had great variations with adjacent environment. To be compared with assessment methodology of soil environment impact at domestic and foreign countries with our results, it might be considered that there was necessary to make a single analysis method based on total heavy metal content with environmental overloading concept because of various analysis methods for total heavy metal content and present analysis method with great variation according to soil environment. In spite of showing higher concentration of heavy metal with acidic digestion than the extractable method, it might be considered that there is need to be adjusted the national standard of soil heavy metal contamination.