• Title/Summary/Keyword: Difference tomography

Search Result 778, Processing Time 0.036 seconds

Evaluation of Average CT to Reduce the Artifact in PET/CT (PET/CT 검사에서 호흡에 따른 인공산물을 줄이기 위한 Average CT의 유용성)

  • Kim, Jung-Sun;Nam, Ki-Pyo;Park, Seung-Yong;Ryu, Jae-Kwang;Cha, Min-Kyeong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.3-7
    • /
    • 2010
  • Purpose: The usefulness of Positron Emission Tomography (PET) images in diagnosis, staging, recurrent and treatment response evaluation has already been known. However, tumors which are small size, located in lower lobe of lung or upper lobe of liver are shown misalignment, distortion and different Standard Uptake Value (SUV) by respiration in PET images. Therefore, if radiotherapy based on normal respiration, it may cause low treatment response or more side effects because targets which had to treat, out of treat range or over dose to normal tissue. The purpose of this study is to evaluate attenuation-correction with Average CT (ACT) for more accuracy SUV measurement and minimize artifact by respiration. Materials and Methods: 13 patients, who had tumors which are around the diaphragm, underwent ACT scan after Helical CT (HCT) scan with PET/CT (Discovery DSTE 8; GE Healthcare). We quantified the differences between attenuation corrected image with HCT and attenuation corrected image with ACT in artifact size and maximum SUV ($SUV_{max}$). Artifacts were evaluated by measurement of the curved photogenic area in the lower thorax of the PET images for all patients. $SUV_{max}$ was measured separately at the primary tumors. Analysis program was Advantage Workstation v4.3 (GE Healthcare). Patients were injected with 7.4 MBq (0.2 $mC_i$) per kg of $^{18}F$-FDG and scanned 1 hour after injection. The PET acquisition was 3 minute per bed. Results: Significantly lower artifact were observed in PET/ACT images than in PET/HCT images (below-thoracic artifacts caused by under corrected $1.5{\pm}3.5$ cm vs. $13.4{\pm}4.2$ cm). Significantly higher $SUV_{max}$ were noted in PET/ACT images than in PET/HCT images in the primary tumor. Compared with PET/HCT images, $SUV_{max}$ in PET/ACT images were higher by $5.3{\pm}3.9%$ (mean value) tumor. The highest difference was observed in Lower lobe of lung (7.7 to 8.7; 13%). Conclusion: Due to its significantly reduced artifacts in lower thoracic, attenuation corrected image with ACT images provided more reliable $SUV_{max}$ and may be helpful in monitoring treatment response. Moreover, ACT can separate upper lobe of liver and lower lobe of lung, it may be helpful in interpretation. ACT will be clinically useful, considering increased dose caused by ACT scan and adapt.

  • PDF

Incidence of Malignancy and Its Predictive Factors in Intrapulmonary Nodules Associated with cT1-2N0M0 Non Small Cell Lung Cancer (임상적 병기 T1-2N0M0인 비소세포폐암에 동반된 폐결절의 악성여부 및 그 예측인자)

  • Yoon, Ho Il;Yim, Jae-Jun;Lee, Choon-Taek;Kim, Young Whan;Han, Sung Koo;Shim, Young-Soo;Yoo, Chul-Gyu
    • Tuberculosis and Respiratory Diseases
    • /
    • v.56 no.2
    • /
    • pp.151-158
    • /
    • 2004
  • Background : When a non small cell lung caner patient at the $_cT_{1-2}N_0M_0$ stage is diagnosed with intrapulmonary nodule(s), the treatment plan and prognosis of the patient largely depend on whether the nodule is benign or malignant. In most cases, however, it is hard to conduct a biopsy on such a nodule, due to its small size. Furthermore, the predictive factors that may imply benignancy or malignancy of the nodules remain unknown. As such, the purpose of our study was to validate the incidence of malignant nodules in such cases, and find if there are any predictive factors. Methods : Chest computed tomography(CT) scans and the medical records of 444 patients, who had undergone non small cell lung cancer surgery, between July, 2001 and September, 2003, at Seoul National University Hospital, were retrospectively reviewed. Among $_cT_{1-2}N_0M_0$ non small cell lung cancer patients, with intrapulmonary nodule(s), only those cases where a CT scan or a biopsy of the nodules had been conducted, and had been followed up at intervals of more than 6 months were included. However, patients who had received chemotherapy or radiation therapy, pre- or post-operatively, or with calcified nodules, were excluded. Results : Our study group consisted of 39 patients, divided into two groups. The first group, 33 patients, had benign nodules, and the second group, 6 patients, had malignant nodules. The two groups were compared with regard to gender, age, cell type, pathologic stage, shape, size, location and number of nodules and presence of calcification around the nodules. There was no statistically significant difference between the two groups. Conclusion : The intrapulmonary nodules in non small cell lung cancer patients at the $_cT_{1-2}N_0M_0$ stage were mostly benign. Therefore, surgical treatment for such patients can be considered. Moreover, without predictive factors, pathological confirmation of the diagnosed nodules should be sought in all patients.

Development of Adaptive Spatial Filter to Improve Noise Characteristics of PET Images (PET 영상의 잡음개선을 위한 적응적 공간 필터 개발)

  • Woo, S. K.;Choi, Y.;Im, K. C.;Song, T. Y.;Jung, J. H.;Lee, K. H.;Kim, S. E.;Choe, Y. S.;Park, C. C.;Kim, B. T.
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.3
    • /
    • pp.253-261
    • /
    • 2002
  • A spatially adaptive falter was formulated to imrove PET image qualify and the Performance of the filter was evaluated using simulation and phantom and human PET studies. In the proposed filter. if a pixel was identified as the edge Pixel, the Pixel value was Preserved. Otherwise a Pixel was replaced by the mean of the pixel values weighted by 2:7: 2. A Pixel was identified as the edge Pixel. if it satisfies the following conditions : the number of ADs (absolute difference between center and neighborhood pixels) which is smaller than THl (($pix_max{\times}0.1/log_2(NPM)$, NPM : mean of 6 neighborhood pixels excluding minimum and maximum) is 8-k and the number of ADs which is lager than TH2 ($NPM{\times}0.1$) is k. where k : 2, 3, …, 6. The results of this study demonstrate the superior performance of the Proposed titter compared to Gaussian fitter, weight median filter and subset averaged median filter. The proposed tittering method is simple but effective in increasing uniformity and contrast with minimal degradation of spatial resolution of PET images and thus. is expected to Provide improved diagnositc quality PET images .

Usefulness of Dynamic $^{18}F-FDG$ PET Scan in Lung Cancer and Inflammation Disease (폐암과 폐 염증성질환의 동적양전자방출단층검사 (Dynamic $^{18}F-FDG$ PET)의 유용성)

  • Park, Hoon-Hee;Roh, Dong-Wook;Kim, Sei-Young;Rae, Dong-Kyeong;Lee, Min-Hye;Kang, Chun-Goo;Lim, Han-Sang;Oh, Ki-Back;Kim, Jae-Sam;Lee, Chang-Ho
    • Journal of radiological science and technology
    • /
    • v.29 no.4
    • /
    • pp.249-255
    • /
    • 2006
  • Purpose: The diagnostic utility of fluorine-18 2-deoxy-D-glucose positron emission tomograhpy ($^{18}F-FDG $PET) for the non-invasive differentiation of focal lung lesions originated from cancer or inflammation disease by combined visual image interpretation and semi-quantitative uptake value analysis has been documented. In general, Standardized Uptake Value(SUV) is used to diagnose lung disease. But SUV does not contain dynamic information of lung tissue for the glucose. Therefore, this study was undertaken to hypothesis that analysis of dynamic kinetics of focal lung lesions base on $^{18}F-FDG$ PET may more accurately determine the lung disease. So we compared Time Activity Curve(TAC), Standardized Uptake Value-Dynamic Curve(SUV-DC) graph pattern with Glucose Metabolic Rate(MRGlu) from Patlak analysis. Methods: With lung disease, 17 patients were examined. They were injected with $^{18}F-FDG$ over 30-s into peripheral vein while acquisition of the serial transaxial tomographic images were started. For acquisition protocol, we used twelve 10-s, four 30-s, sixteen 60-s, five 300-s and one 900-s frame for 60 mins. Its images were analyzed by visual interpretation TAC, SUV-DC and a kinetic analysis(Patlak analysis). The latter was based on region of interest(ROIs) which were drawn with the lung disease shape. Each optimized patterns were compared with itself. Results: In TAC patterns, it hard to observe cancer type with inflammation disease in early pool blood area but over the time cancer type slope more remarkably increased than inflammation disease. SUV-DC was similar to TAC pattern. In the result of Patlak analysis, In time activity curve of aorta, even though inflammation disease showed higher blood activity than cancer, at first as time went by, blood activity of inflammation disease became the lowest. However, in time activity curve of tissue, cancer had the highest uptake and inflammation disease was in the middle. Conclusion: Through the examination, TAC and SUV-DC could approached the results that lung cancer type and inflammation disease type has it's own difference shape patterns. Also, it has outstanding differentiation between cancer type and inflammation in Patlak and MRGlu analysis. Through these analysis methods, it will helpful to separation lung disease.

  • PDF

The Satisfaction Survey of Users and Patients on the Developed Disposable Tourniquet (개발한 일회용 지혈대의 사용자 및 환자 만족도 조사)

  • Kim, Sang-Hyun
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.615-622
    • /
    • 2016
  • The 18~20G needle is used to computer tomography (CT) contrast examination. Therefore, a patient has to apply a self-administering hemostasis (conventional method: CM) and often experience bleeding in the course. Thus, we developed the new disposable transparent tourniquet (TT) for reducing. This study was to compare the usefulness between the proposed transparent tourniquet and the existing hemostatic methods. A Satisfaction survey was conducted by 50 patients and 25nurses. The survey contained the satisfaction of the convenience, safety, sanitation, and wearing sensation of transparent tourniquet. We employed face-to-face interview on 5 points likert scales. And Chi-square, paired T-test were used for the statistics verification. As for the patients, the satisfaction levels were measured for each category with the gender, age. Patients evaluation, overall satisfaction high average sore used TT and there were statistical significance by paired T-test(p<0.05). The following is the average satisfaction level for each category: $4.4{\pm}0.53$ in; $4.28{\pm}0.57$ in safety; $4.52{\pm}0.54$ in sanitation; $4.16{\pm}0.54$ in wearing sensation. So the overall satisfaction level is measured at $4.34{\pm}0.51$. As for the nurses, CT work experience and the current satisfaction with tourniquet were counted as variables. The satisfaction level for each category is: $3.8{\pm}0.7$ in; $3.6{\pm}0.68$ in safety; $3.4{\pm}0.5$ in sanitation; $3.9{\pm}0.49$ in hemostasis. The overall satisfaction level is $3.8{\pm}0.3$. Patients' satisfaction levels were very high with little difference among variables. Nurses' satisfaction levels were different with the TT depending on their work experience but their overall satisfaction was high. This TT will be a starting point to minimizing patient's inconvenience and more studies are necessary to enhance their satisfaction.

A Study on Dose Assessment by 18F-FDG injected into Patients (환자에게 주입된 18F-FDG 의한 선량 평가에 대한 연구)

  • Kim, Chang-Ju;Kim, Jang-Oh;Jeong, Geun-Woo;Shin, Ji-Hey;Lee, Ji-Eun;Jeon, Chan-Hee;Min, Byung-In
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.467-475
    • /
    • 2020
  • The purpose of this study is to assess doses to 18F-FDG, a radioactive drug, during PET examinations, to alleviate anxiety about radiation in patients and carers, to minimize the indiscriminate examination progress caused by medical institution personnel and space clearance problems, and health examination. The dose assessment was measured using a thermo-fluorescent dosimeter (TLD) and an electronic personal dosimeter (EPD) at the location of the cervical (hypothyroid), thorax (heart), and lower abdomen (breeding line) which are the three highest tissue areas of the radiation tissue weighting. In addition, spatial dose rates and radioactivity in urine were measured using GM counters and ion boxes. The results are as follows: First, the personal dosimeter TLD was measured 0.0425±0.0277 mSv in the cervical region, 0.0440±0.0386 mSv in the thorax and 0.0485±0.0436 mSv in the lower abdomen, with little difference in the heart dose depending on radiation sensitivity. The EPD was measured at 0.942±0.141 mSv/h immediately after the cervical position, and 0.192±0.031 mSv/h after 120 minutes. Immediately after the thorax position, 0.516±0.085 mSv/h, 120 minutes later 0.128±0.040 mSv/h. Immediately after the lower abdomen position, 0.468±0.091 mSv/h, and after 120 minutes 0.105±0.021 mSv/h were measured. The spatial dose rate at the GM counter was measured immediately at 0.041±0.005 mSv/h, 120 minutes later at 0.014±0.002 mSv/h. The radioactivity in urine using ion chamber was measured at 0.113±0.24 MBq/cc after 60 minutes and 0.063±0.13 MBq/cc after 120 minutes. As a result, 18F-FDG should be administered, dose re-evaluated two hours after the PET test is completed, and caregivers should be avoided. In addition, it is deemed necessary to provide patients and carers with sufficient explanations and expected values of exposure dose to avoid reckless testing. It is hoped that the data tested in this study will help patients and families relieve anxiety about radiation, and that the radiation workers' exposure management system and institutional improvements will contribute to the development of medical radiation.

Functional Brain Mapping Using $H_2^{15}O$ Positron Emission Tomography ( I ): Statistical Parametric Mapping Method ($H_2^{15}O$ 양전자단층촬영술을 이용한 뇌기능 지도 작성(I): 통계적 파라메터 지도작성법)

  • Lee, Dong-Soo;Lee, Jae-Sung;Kim, Kyeong-Min;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.3
    • /
    • pp.225-237
    • /
    • 1998
  • Purpose: We investigated the statistical methods to compose the functional brain map of human working memory and the principal factors that have an effect on the methods for localization. Materials and Methods: Repeated PET scans with successive four tasks, which consist of one control and three different activation tasks, were performed on six right-handed normal volunteers for 2 minutes after bolus injections of 925 MBq $H_2^{15}O$ at the intervals of 30 minutes. Image data were analyzed using SPM96 (Statistical Parametric Mapping) implemented with Matlab (Mathworks Inc., U.S.A.). Images from the same subject were spatially registered and were normalized using linear and nonlinear transformation methods. Significant difference between control and each activation state was estimated at every voxel based on the general linear model. Differences of global counts were removed using analysis of covariance (ANCOVA) with global activity as covariate. Using the mean and variance for each condition which was adjusted using ANCOVA, t-statistics was performed on every voxel To interpret the results more easily, t-values were transformed to the standard Gaussian distribution (Z-score). Results: All the subjects carried out the activation and control tests successfully. Average rate of correct answers was 95%. The numbers of activated blobs were 4 for verbal memory I, 9 for verbal memory II, 9 for visual memory, and 6 for conjunctive activation of these three tasks. The verbal working memory activates predominantly left-sided structures, and the visual memory activates the right hemisphere. Conclusion: We conclude that rCBF PET imaging and statistical parametric mapping method were useful in the localization of the brain regions for verbal and visual working memory.

  • PDF

Tc-99m ECD Brain SPECT in Patients with Traumatic Brain Injury: Evaluating Distribution of Hypoperfusion and Assesment of Cognitive and Behavioral Impairment in Relation to Thalamic Hypoperfusion (뇌외상 환자의 Tc-99m ECD 뇌 SPECT에서 뇌 혈류감소의 분포 및 시상의 혈류감소에 대한 인지 및 행동장애 평가)

  • Park, Soon-Ah;Lim, Seok-Tae;Sohn, Myung-Hee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.6
    • /
    • pp.445-455
    • /
    • 2000
  • Purpose: We evaluated the distribution of hypoperfusion in patients with traumatic brain injury (TBI) and the relationship of thalamic hypoperfusion to severity of cognitive and behavioral sequelae. Materials and Methods: Tc-99m ECD SPECT and MRI were performed in 103 patients (M/F=81/22, mean age $34.7{\pm}15.4$ yrs) from 0.5 to 55 months (mean 10.3 months) after TBI. The patients were divided into three groups showing no abnormalities (G1), focal (G2) and diffuse injury (G3) on MRI. Psychometric tests assessed 11 cognitive or behavioral items. In all patients, we evaluated the distribution of hypoperfused areas in SPECT, and in 57/103 patients, neuropsychological (NP) abnormalities in patients with thalamic hypoperfusion were compared with those of patients without thalamic hypoperfusion. Results: The perfusion deficits were most frequently located in the frontal lobe (G1, 42.3%: G2 34.5%: G3 33.3%), temporal lobe ($24{\sim}26%$) thalami ($21{\sim}22.4%$), parietal and occipital lobe (${\leq}10%$). Numbers of NP abnormalities in the cases of cortical hypoperfusion with or without concomitant thalamic hypoperfusion were following: the former $4.7{\pm}1.5$ and the latter $3.2{\pm}1.4\;in\;G1,\;5.0{\pm}1.1\;and\;4.8{\pm}1.2\;in\;G2,\;6.8{\pm}1.8\;and\;6.3{\pm}1.1\;in\;G3$, respectively. This difference according to thalamic hypoperfusion was significant in G1 (p=0.002), but was not significant in G2 or G3. Conclusion: SPECT in patients with TBI had demonstrated hypoperfusion mostly involving the frontal, temporal and thalami. In normal group on MRI, frontal hypoperfusion was more prominent than that of any other group, Furthermore in this group, SPECT could predict severity of NP outcome by concomitant thalamic hypoperfusion with cerebral cortical abnormalities.

  • PDF

Dopamine Transporter Density Assessed with $[^{123}I]IPT$ SPECT Before and After Risperidone Treatment in Children with Tourette's Disorder (뚜렛 장애 아동에서 Risperidone 치료 전후 $[^{123}I]IPT$ SPECT로 측정한 기저 신경절 도파민 운반체 밀도)

  • Kim, Tae-Hoon;Ryu, Won-Gee;Park, Se-Young;Chi, Dae-Yoon;Choi, Tae-Hyun;Lee, Kyung-Yul;Cheon, Keun-Ah;Yun, Mi-Jin;Kim, Jai-Keun;Lee, Jong-Doo;Ryu, Young-Hoon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.1
    • /
    • pp.41-51
    • /
    • 2004
  • PURPOSE: Tourette's disorder (TD), which is characterized by multiple waxing and waning motor tics and one or more vocal tics, is known to be associated with abnormalities in the dopaminergic system. To testify our hypothesis that risperidone would improve tic symptoms of TD patients through the change of the dopaminergic system, we measured the dopamine transporter (DAT) densities between drug-naive children with TD and normal children, and investigated the DAT density before and after treatment with risperidone in drug-naive children with TD, using iodine-123 labelled $N-(3-iodopropen-2-yl)-2{\beta}-carbomethoxy-3beta-(4-chlorophenyl)tropane$ ($[^{123}I]IPT$) single photon omission computed tomography (SPECT). MATERIALS and METHODS: $[^{123}I]IPT$ SPECT Imaging and Yale Global Tic Severity Scale-Korean version (YGTSS-K) for assessing the tic symptom severity were carried out before and after treatment with risperidone for 8 weeks in nine drug-naive children with TD. Eleven normal children also underwent SPECT imaging 2 hours after an intravenous administration of $[^{123}I]IPT$. RESULTS: Drug-naive children with TD had a significantly greater increase in the specific/nonspecific DAT binding ratio of both basal ganglia compared with the normal children. However, no significant difference in the specific/nonspecific DAT binding ratio of the basal ganglia before and after treatment with risperidone in children with TD was found, although tic symptoms were significantly improved with risperidone. CONCLUSION: These findings suggest that DAT densities are directly associated with the pathophysiology of TD, however, that the effect of risperidone on tic symptoms in children with TD is not attributed to the change of dopaminergic system.

Consideration on Measured Patients Dose of Three-Dimensional and Four-Dimensional Computer Tomography when CT-Simulation to Radiation Therapy (방사선치료를 위한 CT 검사 시 3DCT와 4DCT에 대한 피폭선량 고찰)

  • Park, Ryeong-Hwang;Kim, Min-Jung;Lee, Sang-Kyu;Park, Kwang-Woo;Jeon, Byeong-Cheol;Cho, Jeong-Hee;Yoo, Beong-Gyu;Lee, Jong-Seok
    • Journal of radiological science and technology
    • /
    • v.34 no.4
    • /
    • pp.341-349
    • /
    • 2011
  • This study was to measure the patient dose difference between 3D treatment planning CT and 4D respiratory gating CT. Study was performed with each 10 patients who have lung and liver cancer for measured patient exposure dose by using SOMATON SENSATION OPEN(SIMENS, GERMANY). CTDIvol and DLP value was used to analyze patient dose, and actual dose was measured in the location of liver and kidney for abdominal examination and lung, heart and spinal cord for chest examination. Rando phantom were used for the experiment. OSLD was used for in-vitro and in-vivo dosimetry. Increasing overall actual dose in 4D respiratory gated CT-simulation using OSLD increase the dose by 5.5 times for liver cancer patients and 6 times for lung cancer patients. In CT simulation of 10 lung cancer patients, CTDIvol value was increased by 5.7 times and DLP 2.4 times. For liver cancer patients, CTDIvol was risen by 3.8 times and DLP 1.6 times. The accuracy of treatment volume could be increased in 4D CT planning for position change due to the breaths of patient in the radiation therapy. However, patients dose was increased in 4D CT than 3D CT. In conclusion, constant efforts is required to reduce patients dose by reducing scan time and scan range.