• Title/Summary/Keyword: Difference tomography

Search Result 769, Processing Time 0.035 seconds

Application of Ultrasound Tomography for Non-Destructive Testing of Concrete Structure (초음파 tomography를 응용한 콘크리트 구조물의 비파괴 시험에 관한 연구)

  • Kim, Young-Ki;Yoon, Young-Deuk;Yoon, Chong-Yul;Kim, Jung-Soo;Kim, Woon-Kyung;Song, Moon-Ho
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.37 no.1
    • /
    • pp.27-36
    • /
    • 2000
  • As a potential approach for non-destructive testing of concrete structures, we evaluate the time-of-flight (TOF) ultrasound tomography technique In conventional X ray tomography, the reconstructed Image corresponds to the internal attenuation coefficient However, in TOF ultrasound tomography, the reconstructed Image is proportional to the retractive index of the medium Because refractive effects are minimal for X-rays, conventional reconstruction techniques are applied to reconstruct the Image in X-ray tomography However, since ultrasound travels in curved path, due to the spatial variations in the refractive index of the medium, the path must be known to correctly reconstruct the Image. Algorithm for determining the ultrasound path is developed from a Geometrical Optics point view and the image reconstruction algorithm, since the paths are curved It requires the algebraic approach, namely the ART or the SIRT Here, the difference between the computed and the measured TOP data is used as a basis, for the iteration process First the initial image is reconstructed assuming straight paths. It then updates the path based on the recently reconstructed image This process of reconstruction and path determination repeats until convergence The proposed algorithm is evaluated by computer simulations, and in addition is applied to a real concrete structure.

  • PDF

Comparative Analysis of Accuracy between Computerized Tomography and Cephalogram for 3-Dimensional Measurement of Maxillofacial Structure (악안면 3차원 계측시 컴퓨터 단층촬영과 두부 방사선 규격사진의 정확성 비교 분석)

  • Paek, Jong-Su;Song, Jae-Chul;Lee, Hee-Kyung
    • Journal of Yeungnam Medical Science
    • /
    • v.18 no.1
    • /
    • pp.123-137
    • /
    • 2001
  • Background: The purpose of this study is to evaluate the accuracy of measurements obtained from 3-dimensional computerized tomography and 3-dimensional cephalogram constructed by using the frontal and lateral cephalogram of six human dry skulls. Materials and Methods: After CT scans and each cephalograms were taken, 3-dimensional coordinates (X, Y, Z) of landmarks were obtained using computer programs. In this study, the accuracy of both methods were determined by means of 14 linear measurements compare with caliper measurements. Results: The standard deviation of landmarks of 3-dimensional CT and 3-dimensional cephalogram were 0.23 mm, and 0.30 mm in X axis, 0.27 mm and 0.25 mm in Y axis, and 0.27 mm and 0.31 mm in Z axis. In both methods, the standard deviation were less than 0.5 mm in all landmarks, and the most of landmarks showed less than 1 mm in range. Concerning the accuracy, the mean difference between 3-dimensional CT and manual measurements was 0.33 mm, and 1.13 mm between 3-dimensional cephalogram and manual measurements. The distance between RGo and LGo showed the largest difference (2.03 mm). There were highly significant, and large correlation with manual measurements in both methods (p<0.01). Conclusion: It is concluded that closeness of repeated measures to each skulls reveal the precision of both methods. Computerized tomography and cephalogram for 3-dimensional measurement of maxillofacial structure are equivalent in quality to caliper measurements.

  • PDF

ACCURACY OF CONE-BEAM COMPUTED TOMOGRAPHY IN PREDICTING THE DIAMETER OF UNERUPTED TEETH (Cone-beam computed tomography를 이용한 미맹출 영구치의 계측)

  • Kim, Seong-Hee;Kim, Young-Jong;Kim, Shin;Jeong, Tae-Sung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.39 no.2
    • /
    • pp.139-144
    • /
    • 2012
  • The purpose of this study was to evaluate the accuracy and reproducibility of measuring the size of unerupted permanent tooth via cone beam computed tomography(CBCT). Ten children were scanned with dental CBCT, and 3-dimensional reconstruction of the dentitions were generated CBCT. Mesio-distal dimension and buccolingual dimension of the teeth were made directly on the model with a high-precision digitalcaliper and on the CBCT by using three-dimensional dental imaging software. Reliability and accuracy were assessed by using intraclass correlation and paired $t$-tests. ($p$ <0.05) The results were as follows : 1. Intraclass correlations were above 0.9 for Both the CBCT and the model measurements, showinghigh reliability. 2. Although there were high correlation values(r=0.91) between CBCT and model messurement methods, comparisons between the CBCT and model messurement methods showed a statistically significant difference($p$ <0.05). 3. The CBCT measurements tended to slightly underestimate by 0.2 mm. But, the systematic difference of CBCT measurements were clinically acceptable Therefore, CBCT measurement method can be used to measure the size of unerupted teeth in a sufficiently accurate way.

Chitin-fibroin-hydroxyapatite membrane for guided bone regeneration: micro-computed tomography evaluation in a rat model

  • Baek, Young-jae;Kim, Jung-Han;Song, Jae-Min;Yoon, Sang-Yong;Kim, Hong-Sung;Shin, Sang-Hun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.38
    • /
    • pp.14.1-14.6
    • /
    • 2016
  • Background: In guided bone regeneration (GBR) technique, many materials have been used for improving biological effectiveness by adding on membranes. The new membrane which was constructed with chitin-fibroin-hydroxyapatite (CNF/HAP) was compared with a collagen membrane (Bio-$Gide^{(R)}$) by means of micro-computed tomography. Methods: Fifty-four rats were used in this study. A critical-sized (8 mm) bony defect was created in the calvaria with a trephine bur. The CNF/HAP membrane was prepared by thermally induced phase separation. In the experimental group (n = 18), the CNF/HAP membrane was used to cover the bony defect, and in the control group (n = 18), a resorbable collagen membrane (Bio-$Gide^{(R)}$) was used. In the negative control group (n = 18), no membrane was used. In each group, six animals were euthanized at 2, 4, and 8 weeks after surgery. The specimens were analyzed using micro-CT. Results: Bone volume (BV) and bone mineral density (BMD) of the new bone showed significant difference between the negative control group and membrane groups (P < 0.05). However, between two membranes, the difference was not significant. Conclusions: The CNF/HAP membrane has significant effect on the new bone formation and has the potential to be applied for guided bone regeneration.

Cone-beam computed tomography versus digital periapical radiography in the detection of artificially created periapical lesions: A pilot study of the diagnostic accuracy of endodontists using both techniques

  • Campello, Andrea Fagundes;Goncalves, Lucio Souza;Guedes, Fabio Ribeiro;Marques, Fabio Vidal
    • Imaging Science in Dentistry
    • /
    • v.47 no.1
    • /
    • pp.25-31
    • /
    • 2017
  • Purpose: The aim of this study was to compare the diagnostic accuracy of previously trained endodontists in the detection of artificially created periapical lesions using cone-beam computed tomography (CBCT) and digital periapical radiography (DPR). Materials and Methods: An ex vivo model using dry skulls was used, in which simulated apical lesions were created and then progressively enlarged using #1/2, #2, #4, and #6 round burs. A total of 11 teeth were included in the study, and 110 images were obtained with CBCT and with an intraoral digital periapical radiographic sensor (Instrumentarium dental, Tuusula, Finland) initially and after each bur was used. Specificity and sensitivity were calculated. All images were evaluated by 10 previously trained, certified endodontists. Agreement was calculated using the kappa coefficient. The accuracy of each method in detecting apical lesions was calculated using the chisquare test. Results: The kappa coefficient between examiners showed low agreement (range, 0.17-0.64). No statistical difference was found between CBCT and DPR in teeth without apical lesions (P=.15). The accuracy for CBCT was significantly higher than for DPR in all corresponding simulated lesions(P<.001). The correct diagnostic rate for CBCT ranged between 56.9% and 73.6%. The greatest difference between CBCT and DPR was seen in the maxillary teeth (CBCT, 71.4%; DPR, 28.6%; P<.01) and multi-rooted teeth (CBCT, 83.3%; DPR, 33.3%; P<.01). Conclusion: CBCT allowed higher accuracy than DPR in detecting simulated lesions for all simulated lesions tested. Endodontists need to be properly trained in interpreting CBCT scans to achieve higher diagnostic accuracy.

Changes of Clinical Practice in Gastrointestinal Perforation with the Increasing Use of Computed Tomography

  • Park, Ji-Min;Yoon, Young-Hoon;Horeczko, Timothy;Kaji, Amy Hideko;Lewis, Roger J
    • Journal of Trauma and Injury
    • /
    • v.30 no.2
    • /
    • pp.25-32
    • /
    • 2017
  • Purpose: The use of computed tomography (CT) to evaluate acute abdominal complaints has increased over the past two decades. We investigated how the clinical practice of patients with intestinal perforation has changed with the increasing use of abdominal CT in the emergency department (ED). Methods: We compared ED arrival to CT time, ED arrival to surgical consultation time, and ED arrival to operation time according to the method of diagnosis from 2003-2004 and 2013-2014. Results: In patients with gastrointestinal perforation, time from ED arrival to CT was shorter ($111.4{\pm}66.2min$ vs. $199.0{\pm}97.5min$, p=0.001) but time to surgical consultation was longer ($135.1{\pm}78.8$ vs. $77.9{\pm}123.7$, p=0.006) in 2013-2014 than in 2003-2004. There was no statistically significant difference in time to operation for perforation confirmed either by plain film or CT between the two time periods. There was no statistically significant difference in length of hospital or ICU stay or mortality between the two groups. Conclusion: With the increasing use of abdominal CT in ED, ED arrival to CT time has decreased and ED arrival to surgical consultation time has increased in gastrointestinal perforation. These changes of clinical performance do not delay ED arrival to operation time or adversely influence patient outcome.

A comparative study between data obtained from conventional lateral cephalometry and reconstructed three-dimensional computed tomography images

  • Oh, Suseok;Kim, Ci-Young;Hong, Jongrak
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.40 no.3
    • /
    • pp.123-129
    • /
    • 2014
  • Objectives: The aim of this study was to verify the concordance of the measurement values when the same cephalometric analysis method was used for two-dimensional (2D) cephalometric radiography and three-dimensional computed tomography (3D CT), and to identify which 3D Frankfort horizontal (FH) plane was the most concordant with FH plane used for cephalometric radiography. Materials and Methods: Reference horizontal plane was FH plane. Palatal angle and occlusal plane angle was evaluated with FH plane. Gonial angle (GA), palatal angle, upper occlusal plane angle (UOPA), mandibular plane angle (MPA), U1 to occlusal plane angle, U1 to FH plane angle, SNA and SNB were obtained on 2D cephalmetries and reconstructed 3D CT. The values measured eight angles in 2D lateral cephalometry and reconstructed 3D CT were evaluated by intraclass correlation coefficiency (ICC). It also was evaluated to identify 3D FH plane with high degree of concordance to 2D one by studying which one in four FH planes shows the highest degree of concordance with 2D FH plane. Results: ICCs of MPA (0.752), UOPA (0.745), SNA (0.798) and SNB (0.869) were high. On the other hand, ICCs of gonial angle (0.583), palatal angle (0.287), U1 to occlusal plane (0.404), U1 to FH plane (0.617) were low respectively. Additionally GA and MPA acquired from 2D were bigger than those on 3D in all 20 patients included in this study. Concordance between one UOPA from 2D and four UOPAs from 3D CT were evaluated by ICC values. Results showed no significant difference among four FH planes defined on 3D CT. Conclusion: FH plane that can be set on 3D CT does not have difference in concordance from FH plane on lateral cephalometry. However, it is desirable to define FH plane on 3D CT with two orbitales and one porion considering the reproduction of orbitale itself.

The Clinical Analysis of the Nasal Septal Cartilage by Measurement Using Computed Tomography

  • Hwang, So Min;Lim, On;Hwang, Min Kyu;Kim, Min Wook;Lee, Jong Seo
    • Archives of Craniofacial Surgery
    • /
    • v.17 no.3
    • /
    • pp.140-145
    • /
    • 2016
  • Background: The nasal septal cartilage is often used as a donor graft in rhinoplasty operations but can vary widely in size across the patient population. As such, preoperative estimation of the cartilaginous area is important for patient counseling as well as operating planning. We aim to estimate septal cartilage area by using facial computed tomography (CT) studies. Methods: The study was performed using facial CT images taken from 200 patients between January 2012 to July 2015. Using the mid-sagittal image, the boundary of cartilaginous septum was delineated from soft tissue using the mean difference in signal intensity (or brightness). The area within this boundary was calculated. The calculated area for septal cartilage was then compared across age groups and sexes. Results: Overall, the mean area of nasal septal cartilage was $8.18cm^2$ with the maximum of $12.42cm^2$ and the minimum of $4.89cm^2$. The cartilage areas were measured to be larger in men than in women (p<0.05). The area decreased with advancing age (p<0.05). Conclusion: Measuring the size of septal cartilage using brightness difference is more precise and reliable than previously reported methods. This method can be utilized as the standard for prevention of postoperative complication.

STUDY ON THE ANATOMICAL POSITION OF MANDIBULAR CANAL USING COMPUTED TOMOGRAPHY IN MANDIBULAR PROGNATHISM PATIENTS (하악 전돌증 환자에서 전산화 단층 촬영을 이용한 하악관의 해부학적 위치에 관한 연구)

  • Lee, Dong-Hyun;Kim, Jae-Won;Lee, Su-Youn;Kim, Jae-Hyun;An, Sang-Heon;Lee, Sang-Han;Jang, Hyun-Jung
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.6
    • /
    • pp.510-518
    • /
    • 2009
  • Purpose: In this study, we analyzed and compared the anatomical position of the mandibular canal in normal occlusion and mandibular prognathism patients. Patients and Methods: Computed tomography image from 58 patients were divided into normal occlusion group and mandibular prognathism group, and each measurement were taken in the each measuring points(2nd premolar, 1st molar, 2nd molar, 3rd molar, ramus). Measurements were statistically analyzed by student's t-test. Results: BC (Thickness of the buccal cortex) value was 2.3~2.7 mm, CB (Distance from the canal to the lingual aspect of the buccal cortex) value was 1.3~4.3 mm, MC (Diameter of the canal) value was 3.2~3.8 mm, LI (Distance from the canal to the lingual aspect of the lingual cortex) value was 2.0~3.7 mm, TM (Thickness of the total mandible) value was 9.5~12.9 mm and CM (Distance from the canal to the inferior border of the mandible) value was 6.9~17.5 mm. Conclusion: In the comparison between two groups, there was statistically significant difference in CB value of 2nd, 3rd molar between normal occlusion and mandibular prognathism, and other value in the rest of the measuring points didn't show statistically significant difference.