• Title/Summary/Keyword: Difference of-Stress

Search Result 3,429, Processing Time 0.032 seconds

The Phonology and Phonetics of the Stress Patterns of English Compounds and Noun Phrases

  • Lee, Joo-Kyeong
    • Speech Sciences
    • /
    • v.14 no.1
    • /
    • pp.21-35
    • /
    • 2007
  • This paper attempts to investigate phonetic substances of the stress patterns of English compounds and noun phrases, showing that the theoretically derived stress structures are not consistent with the accentual patterns in real utterances. Even though it has been long claimed that compounds have the stress pattern [1 3] and that noun phrases, [2 1] as in Chomsky & Halle (1968), their difference has not been yet explored empirically or phonetically. I present a phonetic experiment conducted to see if there is any difference along the tonal contours, mostly focusing on their pitch accent distribution. 36 different compounds and 36 different noun phrases included in carrier sentences were examined, and they were varied in position within a sentence. Results showed that various accentual patterns were produced, and among them, [H* X] predominantly occurs in all three positions in both compounds and noun phrases, whereas the patterns [X H*] and [X X] appear relatively more frequently in final position than in initial and medial position. Furthermore, the pattern [Ac + No], in which the preceding element is pitch-accented with no accent on the following one, is the major stress pattern in both compounds and noun phrases and in all three sentence positions. This suggests that there seems to be no difference in accentual patterns between compounds and noun phrases, which is not consistent with the hypothesis. The results are interpreted as saying that the preceding element alone tends to be prominent with no accent following it both in compounds and noun phrases, and that therefore, theoretically speculated phonological claims are not always phonetically supported.

  • PDF

A STUDY ON STRESS DISTRIBUTION IN IMZ IMPLANT WITH A PLASTIC OR A TITANIUM IME USING FINITE ELEMENT ANALYSIS (유한요소법을 이용한 IMZ임플란트의 플라스틱 및 티타늄 IME의 응력분포에 관한 연구)

  • Ha Chi-Yang;Choi Boo-Byung;Woo Yi-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.4
    • /
    • pp.625-642
    • /
    • 1993
  • Whether stress-absorbing elements are functional in an implant system has been an issue of interest in oral implantology. The unique feature of the IMZ implant system is the planned imitation of the stress-distributing function of the structural unit of the tooth, periodontium, and alveolar bone through the use of an intramobile element(IME). The purpose of this study was to compare the difference in the displacement and the stress distibutions of IMZ implant with a polyoxymethylene(POM) or a titanium IME under static load. Two dimensional finite element analysis(FEA) was applied for this study and two finite element models were created. PATRAN program(DPA Co.,USA), a software for FEA, and SUN-SPARC2GX(SUN Co., USA), a workstation computer, were used. $1Kg/mm^2$ of static load was loaded individually on each three point of crown of implant prosthesis ; central fossa(load 1), mesial cusp tip(load 2), distal cusp tip(load 3), The displacements of X- and Y-axis and total displacement were measured at mesial and distal cusp tips, mesial and distal points between crown and IME, and implant apex. The von Mises stress was measured at mesial and distal points between crown and IME, mesial and distal points between IME and TIE, mesial and distal alveolar crest, the mesial and distal midpoints of implant, and implant apex. The difference in resultant values were compared and evaluated statistically using paired t-test. The results were as follows : 1. Under the load 1, all the displacement of implant with titanium IME at 5 measuring points was larger than that of with POM IME except total and Y-axis displacement at implant apex. And the differences in stress distributions with POM and titanium were varied. 2. Under the load 2, all the displacement of implant with titanium IME at 5 measuring points was larger than that of with POM IME except X-axis displacement at distal cusp tip. And the differences in stress distributions were varied. 3. Under the load 3, all the displacement of implant with titanium IME at 5 measuring points was larger than that of with POM IME except Y-axis displacement at mesial cusp tip. And the differences in stress distributions were varied. 4. For the displacement, there was significant difference statistically only in total displacement (P<0.1), but was no significant difference in X- and Y-axis displacement(P>0.1). For the stress, there was no significant difference among the compared values.

  • PDF

A STUDY OF THE STRESS TRANSMISSION OF VARIOUS ARTIFICIAL TEETH AND DENTURE BASE MATERIALS TO THE UNDER-LYING SUPPORTING TISSUES (인공치와 의치상의 재질에 따른 의치상 하부 지지조직에의 응력전달에 관한 연구)

  • Chung, Hyun-Gun;Chung, Moon-Kyu;Lee, Ho-Yong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.27 no.2
    • /
    • pp.79-100
    • /
    • 1989
  • The Purpose of this study was to investigate material differences in stress transmission among various artificial teeth and denture base materials. For this study, a two-dimensional finite element model and a two-dimensional photoelastic model of a mandible with complete denture were made. A resin tooth and a porcelain tooth were used as artificial teeth, and a resin base, a metal lined base, and a soft-liner lined base were used as denture bases. An occlusal load was applied and principal stresses generated in the supporting tissues were compared. To test the impact stress transmission, strain gauge attached to the denture base specimens made of the different materials were made in thick and thin groups. Voltage outputs from hitting the specimen with a steel ball were compared. The results were as follows : 1. In FEM, increasing the mucosal thickness reduced the maximum principal stresses in the supporting tissues, but altering the tooth materials and the base materials induced no difference in the stresses. 2. In photoelastic model study, no difference in fringe order among the specimens were observed, but the thick mucosa group and the soft-liner lined group revealed a more uniform distribution of the load. 3. In strain measuring, the impact force transmission was highest in the soft-liner lined group, and was the lowest in the metal lined group(p<0.01). 4. In the thin group using the resin base, the porcelain tooth showed higher impact stress transmission than the resin tooth(p<0.01), but no difference was observed between them in the thick group. In the soft-liner lined group, the porcelain tooth showed higher impact stress transmission than the resin tooth(p<0.01), but no difference was observed between them in the metal lined group. 5. The thick group showed lower impact stress transmission than the thin group(p<0.01).

  • PDF

A Comparative Study on the Impacts of Emotional Labor of Workers with the Types of Hospital Influencing Job Stress by Health Care - General Hospital and Nursing Hospital (헬스케어에 따른 병원종별 종사자의 감정노동이 직무스트레스에 미치는 영향 비교 : 일반병원과 요양병원)

  • Jeong, Yeon-Ja
    • Journal of Korea Entertainment Industry Association
    • /
    • v.14 no.7
    • /
    • pp.659-666
    • /
    • 2020
  • This study is a comparative study on the impacts of workers' emotional labor influencing job stress by health care and the types of hospitals. The research used 387 questionnaires as final assay data, which were obtained by health care workers who work for hospitals or higher-level hospitals located in G-metropolitan city, JD through the direct survey method. The results are as follows. First, after analyzing the difference of emotional labor and job stress in terms of socio-demographic characteristics, there was a significant difference in both general hospital and nursing hospital: In case of general hospitals, a significant difference in emotional labor is shown based on monthly earnings and the years of employment at current hospital, and a significant difference in job stress is shown based on an academic career, the years of employment at current hospital, and the establishment classification. In case of nursing hospitals, there was a significant difference in emotional labor based on an academic career, alcohol use, and monthly earnings. Second, after analyzing the correlation between emotional stress and job stress by the type of hospital, a significant positive correlation is observed at both general hospital and nursing hospital. Third, after comparing the impacts of emotional labor on job stress by the type of hospital, it was shown that emotional labor has a significant positive impact on job stress at both general hospital and nursing hospital.

A Study on the Work Stress of Dental Technicians (치과기공사의 업무스트레스에 관한 연구)

  • Kwon, Eun-Ja;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.23 no.2
    • /
    • pp.105-119
    • /
    • 2002
  • This study was designed to grasp the degree of job stress affecting dental technicians and the degree of the symptoms of their job stress. With this in mind, the researcher selected a total of 170 dental technicians living in Seoul and Incheon, conducting a research in a period ranging from August 1,2001, to August 20, 2001. The researcher made use of a structured questionnaire whose reliability and feasibility are proved. The questionnaire is composed of a total of 55 questions: thirteen questions related to the subjects' general characteristics; 28 questions connected to the measurement of job stress and fourteen questions linked with the measurement of job-stress symptoms. The researcher analyzed the findings with the aid of SPSS(Statistical Package for Social Sciences). The research came to draw the following conclusions on the basis of frequency, percentage, T-test, and F-test, multiple regression. I. The analysis into the job stress of the subjects indicates that there is a significant difference in difficult questions among their work places, working hours, academic background, job satisfaction and jobs(P<.05). The job stress stands at 3.48 on the average, and the area of conflict among too much work and job performance turns out to be highly perceived. 2. The analysis into the degree of the symptoms of the job stress of the subjects shows that there is a significant difference in work place, working hours, job satisfaction and the continual maintenance of job(P<.05). The symptoms of job stress accounts for 2.65 on the average. Physical symptoms turn out to be highly perceived; The response 'My arms and legs are killing me' proves to stand for 3.03. 3. The correlation between job stress and the symptoms of job stress turns out to be significant(r=0.519, P<0.001), and there is a significant correlation between the average points of each job-stress area and the average points of the symptoms of job stress. All in all, it is necessary that dental technicians themselves should make positive efforts to control and relieve stress and that more efficient programs should be implemented with a view to dealing with stress.

  • PDF

Analysis of thermal stresses developed in plasma sprayed layer (플라즈마 용사층에 발생하는 응력해석)

  • 배강열;김희진
    • Journal of Welding and Joining
    • /
    • v.8 no.4
    • /
    • pp.58-68
    • /
    • 1990
  • The formation of thermal stresses by plasma spraying is generally considered as adverse. Therefore, the knowledge of stress distribution in the deposited layer during and after plasma spraying will be of special interest. In this study finite difference heat transfer analysis and finite element stress analysis were carried out to predict the change of stress distribution in the plasma coated layer with the variations of preheat temperature, number of scan, particle size, and bond coat. The results of the numerical analysis were as follows: 1) Transient stresses developed in the coated layer were up to the level of yiedl strength at the temperature. 2) The tensile stresses were developed in the deposited layer and the surface of the substrate, but the compressive stresses were developed in the rest of the substrate. 3) Transient and residual stresses were significantly affected by the preheat temperature. 4) The variations of temperature of powder particle and number of torch scan changed tensile stress distribution, but made no difference on the magnitude of the stresses. 5) Bond coated layer reduced the stree level of deposited layer.

  • PDF

The Study on the Effect of the Maternal Variables on the Verbal Abuse (아동에 대한 언어적 학대에 영향을 미치는 어머니 관련변인에 관한 연구)

  • 최정미;우희정
    • Journal of the Korean Home Economics Association
    • /
    • v.40 no.5
    • /
    • pp.225-235
    • /
    • 2002
  • The purpose of this research is to delineate the effect of maternal variables of the verbal abuse. Such variables as the mother's age, her education level, and maternal parenting stress have been chosen for the analysis. The sample subject were 659 pairs of fifth/sixth grade of elementary school and firs/second grade of middle school, and their mothers. The major findings of the research are as follows: first, looking at the correlation between the mother's age/education level and the verbal abuse, the verbal abuse factor shows difference correlating to the mother's age/education level. Second, looking at the correlation between the material parenting stress level and the verbal abuse, the verbal abuse factor shows difference correlating to the maternal parenting stress level. Third, the result of multiple regression analysis on the effects of the maternal variables to the verbal abuse indicates that material parenting stress is the significant contributing factor. All in all, the maternal variables account for 9% of the verbal abuse score.

The Effects of Job Stress on Burnout and Job Satisfaction of Flight Attendants -Focusing on Comparison between Full Service Carrier and Low Cost Carrier- (항공사 객실승무원의 직무스트레스가 소진과 직무만족에 미치는 영향 - 대형항공사와 저비용항공사 간 비교를 중심으로 -)

  • Han, Sue-Youn;Lee, Hee-Chan
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.22 no.3
    • /
    • pp.33-49
    • /
    • 2014
  • The object of this study is to verify the effects of job stress on burnout and job satisfaction of flight attendants and to confirm the difference in the effect on the consciousness of full service carrier and low cost carriers' flight attendants. In order to confirm, the study examines the relationship between job stress, burnout, and job satisfaction of airline cabin attendant. A survey was done for 55days from January 5th 2014 on flight attendants and total 200 valid samples were analysed. The results of the study demonstrated significant relationship and difference in job stress, burnout and job satisfaction of flight attendants between full service carrier and low cost carrier. As a result, the study is significant as it satisfaction between divergent airline work environment.

Stress Analysis of Rotor Part in Gas-Gas Heater (가스 재열기 로터 부위의 응력 해석)

  • 이후광;황석환;최재승
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.639-642
    • /
    • 2001
  • The possibility of weight reduction of rotor part in gas-gas geater(GGH) is studied from the viewpoint of allowable stress. In this work, finite element analysis(FEA) is performed with original model and three weight-reduced models with different diaphragm thickness, respectively. Stress concentrations at rotor diaphragm happen due to the dead weight, pressure difference between treated gas and untreated gas and thermal distribution in the rotor. As the thickness of diaphragm is decreased, the stress level is increased. The direction of treated gas and untreated gas flow may affect the stress level. Fatigue life assessment is not considered because pressure difference, the only cyclic load, can be ignored. The possible weight-reduced model is presented.

  • PDF

Study for Accessment of Structural Stability of SAS Reactor (SAS 반응기의 구조 안전성 평가 연구)

  • 이은우;정의동;김윤춘;김종배
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1995.10a
    • /
    • pp.43-49
    • /
    • 1995
  • Sasol Advanced Synthol Reactor was divided into two chambers by grid plate perforated with diffuser holes. The reactor has high stress level beacuse of membrane stress due to internal pressure, thermal stress due to temperature difference and local stress due to structural discontinuity at the juncture of grid plate and shell. Moreover, geometric nonlinear behaviors may appear in the grid plate because of pressure difference between two chambers. In order to survey the stress level and geometric nonlinear behaviors around grid plate, heat transfer analysis, linear static analysis and geometric nonlinear analysis were performed using NISA II developed by EMRC. This paper demonstrates the result of accessment for linear static and geometric nonlinear analysis under various load combinations.

  • PDF