• Title/Summary/Keyword: Difference Voltage

Search Result 1,059, Processing Time 0.024 seconds

Study on the Nonlinear Electromagnetic Acoustic Resonance Method for the Evaluation of Hidden Damage in a Metallic Material (금속 재료의 잠닉손상 평가를 위한 비선형 전자기음향공진 기법에 관한 연구)

  • Cho, Seung-Wan;Cho, Seung-Hyun;Park, Choon-Su;Seo, Dae-Cheol;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.4
    • /
    • pp.277-282
    • /
    • 2014
  • Recently, much attention has been paid to nonlinear ultrasonic technology as a potential tool to assess hidden damages that cannot be detected by conventional ultrasonic testing. One nonlinear ultrasonic technique is measurement of the resonance frequency shift, which is based on the hysteresis of the material elasticity. Sophisticated measurement of resonance frequency is required, because the change in resonance frequency is usually quite small. In this investigation, the nonlinear electromagnetic acoustic resonance (NEMAR) method was employed. The NEMAR method uses noncontact electromagnetic acoustic transducers (EMATs) in order to minimize the effect of the transducer on the frequency response of the object. Aluminum plate specimens that underwent three point bending fatigue were tested with a shear wave EMAT. The hysteretic nonlinear parameter ${\alpha}$, a key indicator of damage, was calculated from the resonance frequency shift at several levels of input voltage. The hysteretic nonlinear parameter of a damaged sample was compared to that of an intact one, showing a difference in the values.

A Study on the Torque Characteristics Depending on the Elastic Body Materials of a Hexadecagon Shaped Ultrasonic Motor (탄성체 재질 변화에 따른 16각형 초음파모터의 토크 특성 연구)

  • Cheon, Seong-Kyu;Jeong, Seong-Su;Lee, Byung-Ha;Ha, Yong-Woo;Kim, Myong-Ho;Park, Tae-Gone
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.5
    • /
    • pp.286-291
    • /
    • 2014
  • In this study, novel ultrasonic rotary motor of hexadecagon shape stator was proposed. Stator of the hexadecagon ultrasonic motor was composed of an elastic ring and ceramics. The elastic ring had sixteen sides and sixteen angular points. Eight ceramics were attached on the outer surface of the eight sides of the ring. When rotor of cylindrical shaft was inserted inside of the ring stator, central lines of the sixteen sides of the stator hold the shaft by the slight pressures(frictions). This slight pressure was a preload of the motor and it could be controlled by radius and thickness of the ring. When two sinusoidal voltages which have 90 degree phase difference were applied to each four ceramics, elliptical displacements of inner surface of the ring were obtained. These elliptical displacements of the inner surface rotated the shaft rotor through the frictions. The proposed hexadecagon ultrasonic motor was designed and analyzed by using the finite element method (FEM), depending on materials of the elastic ring. Based on the FEM results, one model of motor which showed maximum displacement at contact points was chosen and fabricated. And characteristics of the motor were compared with simulated results. When the motor was fabricated with these results, EL20ET0.5CT0.5CW2 model showed 115[rpm] speed about input voltage of 60[Vrms] at 65.6[kHz]. And the maximum torque of 6[gfcm] was obtained. From these results, the hexadecagon shaped ultrasonic motor can be used to actuator for optical device which needs detailed position control. Also it can be used to medical and portable device by reducing size and weight.

A Study on Improvement of Image Quality Decrease due to Tooth Restoration in Facial CT (안면부 CT 검사 시 치아 충전물에 의한 화질 저하 개선 방안에 관한 연구)

  • Kim, Hyeon ju;Yoon, Joon
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.4
    • /
    • pp.497-503
    • /
    • 2018
  • The purpose of this study was to investigate the degree of image degradation and the improvement of image quality caused by the density difference between the orthodontic filling material and the surrounding anatomical structure during the examination of the facial CT by quantitative and qualitative analysis. The teeth were scanned using 64-MDCT (Discovery 750 HD, GE HEALTH CARE, Milwaukee, USA). The teeth were scanned and compared according to tube voltage, silicone application, and MAR application. As a result, 10.36% CT value decreased at 140 kVp and 5.81% decrease at the application of silicon material. As a result of the qualitative evaluation, it was evaluated that 7 of the 10 observers and 3 of the acceptors were applied to the MAR algorithm. Therefore, it is possible to reduce the unnecessary burden on the radiation exposure dose as well as to reduce the loss of image data by reducing the high density artifacts, as well as the inspection parameters used in the current clinical application and various algorithms that can reduce the high density artifacts. It can be expected to provide a lot of image information.

Parthenogenetic Activation of Porcine Oocytes and Isolation of Embryonic Stem Cells-like Derived from Parthenogenetic Blastocysts

  • Xu, X.M.;Hua, J.L.;Jia, W.W.;Huang, W.;Yang, C.R.;Dou, Z.Y.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.20 no.10
    • /
    • pp.1510-1516
    • /
    • 2007
  • These experiments were carried out to optimize the parameters of electrical activation, methods of parthenogenetic activation and embryo culture in vitro and meanwhile to isolate embryonic stem cells-like (ESCs) derived from porcine parthenogenetic blastocysts (pPBs). These results showed that, as the electric field strength increased from 1.0 to 2.7 kV/cm, the cleavage rate of parthenogenetic embryos increased gradually but the rate of oocyte lysis was significantly increased when using 2.7 kV/cm field strength. The rate of cleavage in 2.2 and 2.7 kV/cm groups was significantly increased in comparison with that of the 1.0 kV/cm group. A voltage field strength of 2.2 kV/cm DC was used to investigate blastocyst development following activation with a single pulse of 30 or $60-{\mu}sec$ pulse duration. The optimum pulse duration was 30-${\mu}sec$, with a blastocyst rate of 20.7%. Multiple pulses were inferior to a single pulse for blastocyst yield (8.0% vs. 29.9) (p<0.05). For porcine oocyte parthenogenetic activation methods, the rates of cleavage (79.0% vs. 59.8%) and blastocysts (19.4% vs. 3.4%) were significantly increased in electrical activation in contrast to chemical activation with ionomycin/6-DMAP (p<0.05). Rates of cleavage and blastocyst formation in NCSU-23 and PZM-3 embryo media were higher than those of G1.3/G2.3 serial culture media, but there was no significant difference among the three groups. The total cell number of blastocysts in PZM-3 embryo culture media containing $5{\mu}g/ml$ insulin was significantly higher than that of the control (no insulin) ($44.3{\pm}9.1$ vs. $33.9{\pm}11.7$). For isolation of PESCs-like, the rates of porcine blastocysts attached to feeder layers and ICM colony formation in Method B (nude embryo culture) were better than those in Method A (intact embryo culture).

Effect of Thermal Management of Lithium-Ion Battery on Driving Range of Electric Vehicle (리튬이온 배터리의 열관리가 전기자동차 주행거리에 미치는 영향)

  • Park, Chul-Eun;Yoo, Se-Woong;Jeong, Young-Hwan;Kim, Kibum
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.5
    • /
    • pp.22-28
    • /
    • 2017
  • The performance of lithium ion batteries used in electric vehicles (EV) varies greatly depending on the battery temperature. In this paper, the finite difference method was used to evaluate the temperature change, state of charge (SOC), internal resistance, and voltage change of the battery due to heat generation in the battery. The simulation model was linked with AMESim to calculate the driving range of an EV traveling in New European Driving Cycle (NEDC) mode. As the temperature dropped below $25^{\circ}C$, the internal resistance of the battery increased, which increased the amount of heat generated and decreased the driving range of EV. At battery temperatures above $25^{\circ}C$, the driving range was also decreased due to reduced SOC that deteriorated the battery performance. The battery showed optimal performance and the driving range was maximized at $25^{\circ}C$. When battery temperatures of $-20^{\circ}C$ and $45^{\circ}C$, the driving range of EV decreased by 33% and 1.8%, respectively. Maintaining the optimum battery temperature requires heating the battery at low temperature and cooling it down at high temperature through efficient battery thermal management. Approximately 500 W of heat should be supplied to the battery when the ambient temperature is $-20^{\circ}C$, while 250 W of heat should be removed for the battery to be maintained at $25^{\circ}C$.

Development of Smart Multi-function Ground Resistivity Measuring Device using Arduino in Wind Farm (풍력 발전단지내 아두이노를 활용한 스마트 다기능 대지 고유 저항 측정 장치 개발)

  • Kim, Hong-Yong;Yoon, Dong-Gi;Shin, Seung-Jung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.6
    • /
    • pp.65-71
    • /
    • 2019
  • Conventional methods of measuring ground resistance and ground resistance field measurement are used to measure voltage drop according to the resistance value of the site by applying current by installing a constant interval of measurement electrode. If the stratified structure of the site site is unique, errors in boundary conditions will occur in the event of back acid and the analysis of the critical ground resistance in the ground design will show much difference from simulation. This study utilizes the Arduino module and smart ground measurement technology in the convergent information and communication environment to develop a reliable smart land resistance measuring device even if the top layer of land is unique, to analyze the land resistance and accumulate data to predict the change in the age of the land. Considering the topographical characteristics of the site, we propose a ground resistance measuring device and its method of measuring ground resistance so that the auxiliary electrode can be installed by correctly positioning the angle and distance in measuring ground resistance. Not only is ground resistance value obtained through electrodes installed to allow accurate ground resistance values to be selected, but it can also be used as a useful material for installing electrical facilities in similar areas. Moreover, by utilizing reliable data and analyzing the large sections of the site, a precise analysis of the site, which is important in ground design as well as construction cost, is expected to be used much in ground facility design such as potential rise.

A Design of 0.357 ps Resolution and 200 ps Input Range 2-step Time-to-Digital Converter (0.357 ps의 해상도와 200 ps의 입력 범위를 가진 2단계 시간-디지털 변환기의 설계)

  • Park, An-Soo;Park, Joon-Sung;Pu, Young-Gun;Hur, Jeong;Lee, Kang-Yoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.5
    • /
    • pp.87-93
    • /
    • 2010
  • This paper presents a high resolution, wide input range 2-step time-to-digital converter used in digital PLL. TDC is used to compare the DPLL output frequency with reference frequency and should be implemented with high resolution to improve the phase noise of DPLL. The conventional TDC consists of delay line realized inverters, whose resolution is determined by delay time of inverter and transistor size, resulting in limited resolution. In this paper, 2-step TDC with phase-interpolation and Time Amplifier is proposed to meet the high resolution and wide input range by implement the delay time less than an inverter delay. The gain of Time Amplifier is improved by using the delay time difference between two inverters. It is implemented in $0.13{\mu}m$ CMOS process and the die area is $800{\mu}m{\times}850{\mu}m$ Current consumption is 12 mA at the supply voltage of 1.2 V. The resolution and input range of the proposed TDC are 0.357 ps and 200 ps, respectively.

Design of Low Noise Readout Circuit for 2-D Capacitive Microbolometer FPAs (정전용량 방식의 이차원 마이크로볼로미터 FPA를 위한 저잡음 신호취득 회로 설계)

  • Kim, Jong Eun;Woo, Doo Hyung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.10
    • /
    • pp.80-86
    • /
    • 2014
  • A low-noise readout circuit is studied for 2-D capacitive microbolometer focal plane arrays (FPAs). In spite of the merits of the integration method, a simple and effective pixelwise readout circuit without integration is used for input circuit because of a small pixel size and narrow noise bandwidth. To reduce the power consumption and the kT/C noise, which is the dominant noise of the capacitive microbolometer FPAs with small capacitance, a new correlated double sampling (CDS) is used for columnwise circuit. The proposed circuit has been designed using a $0.35-{\mu}m$ 2-poly 4-metal CMOS process for a microbolometer array with a pixel size of $50{\mu}m{\times}50{\mu}m$. The proposed circuit effectively reduces the kT/C noise and the other low-frequency noise of microbolometer, and the noise characteristics of the fabricated chip have been verified by measurements. The rms noise voltage of the proposed circuit is reduced from 30 % to 55 % compared to that of the simple readout input circuit, and the noise equivalent temperature difference (NETD) of the proposed circuit is very low value of 21.5 mK.

Radiation Dose and Image Evaluation for Position Change in Low Extremity Teleography (하지전신계측검사에서 자세의 변화에 따른 방사선량 및 영상평가)

  • Kim, Yeongcheon;Song, Jongnam;Choi, Namgil;Jeong, Yeon;Han, Jaebok
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.7
    • /
    • pp.409-415
    • /
    • 2014
  • In this study, radiation doses of major organs in various postures in lower extremity teleography were measured and compared to investigate the utility of the test methods. Ten adult males who underwent lower extremity teleography at a tube voltage of 73 kVp, tube current of 32 mAs, and SID of 180 cm. Using rando phantom, glass dosimeter was attached to the eye lens, thyroid gland, and genital gland to measure the radiation dose in each area 5 times in each anteroposterior posture and posteroanterior posture. The results were compared and analyzed through Paired T-test. The images from the anteroposterior posture and posteroanterior posture were evaluated through the blind test on a scale of 5. As a result, the posteroanterior method could reduce the dose than the anteroposterior posture method: less dose for the eye lens by 6%, thyroid gland by 6%, and genital gland by 26%. Since there was no significant difference in image evaluation, the posteroanterior posture is considered better than the anteroposterior posture in lower extremity teleography.

Comparison Study of AAS and ISE Method in the Lithium Analysis of Serum and Urine (혈액 및 소변의 Lithium치 측정에 있어서 AAS법과 ISE법의 비교)

  • Lee, Soo-In;Lee, Chae-Hoon;Kim, Kyung-Dong;Kim, Chung-Sook
    • Journal of Yeungnam Medical Science
    • /
    • v.10 no.2
    • /
    • pp.409-416
    • /
    • 1993
  • In the method for lithium (Li) analysis, flame emission photometry and atomic absorption spectrophotometry (AAS) have been used most frequently. In addition, lithium can be analyzed by ion-selective electrode (ISE) or fluorscence polarization immunoassay. We evaluated the comparison between AAS method based on the principle of absorption of light at 670.8 nm by Li and ISE method based on the principle of voltage difference generated by Li in contact with lithium ionophore. We compared with those obtained by AAS (AA/AE Spectrophotometer 551, Instrumentation Laboratory Co.) and ISE(CSYNCHRON EL-ISE, Beckman Co.) in the serum and urine of 6 patients and evaluated time-related changes of serum lithium concentration after dosing in both methods. The results are summarized as follows : 1. In within-run precision study for lithium concentration, coefficient variations (CVs, %) ranged from 1.34 to 2.17 for AAS and from 0.34 to 0.85 for ISE method. In between-run precision study for lithium concentration, CVs ranged from 1.23 to 1.72 for AAS and from 0.61 to 1.38 for ISE method. 2. The correlation study between AAS and ISE method resulted in Y=0.946X+0.137 (N=32, r=0.933, X=AAS, Y=ISE) for serum lithium and Y=1.092X+0.977 (N=28, r=0.943, X=AAS, Y=ISE) for urine lithium. 3. Time-related changes of serum lithium concentration in both AAS and ISE method resulted in peak serum levels about 2 hours after dosing and then rapidly decreased after the peak serum level and finally arrived at nearly initial levels about 9 hours after dosing. 4. The reference range of serum lithium was found as undetectable level for both AAS and ISE method and the reference range of urine lithium to the urine creatinine was 0-0.00014 mmol/mg(mean 0.00002 mmol/mg) for AAS method.

  • PDF