• 제목/요약/키워드: Difference Voltage

검색결과 1,059건 처리시간 0.032초

전압형 Dual PWM 컨버터의 변조각 지연에 따른 보상법 및 순시전류 제어기 구성 (The Compensation Method of the Modulation-delay for the Voltage type Dual PWM Converter and Composition of the Instantaneous Current Controller)

  • 정연택;김원철;이사영;전지용;김현봉;이근홍
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.369-372
    • /
    • 1994
  • In this paper, a voltage type dual PWM converter which achives the bidirectional power flow between a AC supply and a DC bus voltage is described. In PWM modulator, there exist a time difference between the sampling time and carrier wave, it achieves stable modulation even the disturbance in the synchronous AC source voltage. And this paper proposes the compensation method and the control method related a disturbance of synchronous signal using the low pass filter and phase shifter for the stable modulation. As a result the voltage type dual PWM converter makes the imput current wave as sinusoid, and performs the high power factor driving.

  • PDF

플라잉 커패시터 멀티-레벨 인버터의 커패시티 잔압 균형을 위한 캐리어 비교방식의 펄스 폭 변조 기법 (The Carrier-based SVPWM method for voltage balance of flying capacitor multilevel inverter)

  • 강대욱
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.313-316
    • /
    • 2000
  • This paper proposes a new solution by carrier-based SVPWM method to solve the most serious problem of Flying Capacitor Multi-level Inverter that is unbalance of capacitor voltages The voltage unbalance is occurred by the difference of each capacitor's charging and discharging time applied to Flying Capacitor Multi-level Inverter. It controls the variation of capacitor voltages into the mean'0' during some period by means of new carriers using the leg voltage redundancy in the Inverter. The solution can be easily expanded to the multi-level. Also this method can make the switching loss and conduction loss of device equal by the use of leg voltage redundancy. First the unbalance of capacitor voltage is analyzed and the conventional theory of self-balance using phase-shifted carrier is reviewed. And then the new method that is suitable to the Flying Capacitor Inverter is explained. The simulation results would be shown to verify the proposed method

  • PDF

권선형 유도 발전기 CVCF 발전을 위한 2차 여자 제어법에 관한 연구 (A Study on the 2nd exitation method for CVCF Generation of doubly-fed induction Generator)

  • 안진우;김철우;황영문
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 추계학술대회 논문집 학회본부
    • /
    • pp.341-344
    • /
    • 1988
  • This paper derives a condition foe constant voltage i constant frequency generation of doubly-fed induction generator. The condition is varied by the magnitude of output voltage, load current and its power factor, slip of the machine. Magnitude of output voltage is controlled by exiting voltage which is caculated by derived equation from operating condition. frequency of output voltage is controlled by injecting slip frequency to the rotor which is the difference between wanted output frequency and rotor frequency.

  • PDF

대칭분 전압 단위 벡터를 이용한 송전선로 보호용 고장상 선택 알고리즘 (Fault Phase Selection Algorithm using Unit Vector of Sequence Voltages for Transmission Line Protection)

  • 이명수;이재규;김수남;유석구
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권9호
    • /
    • pp.460-466
    • /
    • 2002
  • A reliable fault phase selection algorithm plays a very important role in transmission line protection, Particularly in Extra High Voltage (EHV) networks. The conventional fault phase selection algorithm used the phase difference between positive and negative sequence current excluding load current. But, it is difficult to pick out only fault current since we can not know when a fault occurs and select the fault phase in weak-infeed conditions that dominate zero-sequence current in phase current. The proposed algorithm can select the accurately fault phase using the sum of unit vectors which are calculated by positive-sequence voltage and negative-sequence voltage.

AVR 기능 부가 off-line UPS 설계 (Design of off-line UPS with AVR)

  • 이성희;박태준;이진희;이왕하;이치환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.605-607
    • /
    • 2001
  • In this paper, an off-tine UPS with CVT(constant voltage transformer) is designed and the experimental result and problems of the designed UPS is given and discussed. This off-line UPS consists of triple-port CVT and PWM inverter which acts as charger and inverter. It can be evaluated in low price because haying simple structure. It offers high performance because CVT restricts the short current automatically about two or three times of rated current, has nearly unit power factor and constant output voltage to varying input voltage. The weak points of this UPS are that the output voltage waveform is not perfect sinusoidal and has phase difference to input voltage. The experimental result and problems of the designed UPS is given.

  • PDF

고압전동기 결함신호의 특징추출에 관한 연구 (Feature Extraction for Fault Signals of High Voltage Motor Stator Windings)

  • 박재준;김희동
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.1154-1157
    • /
    • 2004
  • During normal machine operation, partial discharge(PD) measurements were performed with turbine generator analyzer(TGA) in imitation stator winding of high voltage motors. The motor was energized to 4.47kV, 6.67, respectively. Applied voltage to Imitation winding was used two voltage level, 4.47[KV]and 6.67[KV]. Motors having imitation stator winding were installed with 80pF capacitive couplers at the terminal box Case of PD Pattern regarding applied voltage phase angel, the PD patterns were displayed two dimensional and three dimensional. TGA summarizes each plot with two quantities such as the normalized quantity number(NQN) and the peak PD magnitude(Qm). As the result, we could discrimidate using TGA the difference of internal and surface discharge for imitation stator winding. We have used the other technique, in order to feature extraction of faulty signals on stator winding, Daubechies Discrete wavelet transform and Harmonics analysis(FFT) about faulty signals.

  • PDF

열전모듈의 냉각특성에 관한 실험적 연구 (An experimental study on cooling characteristic of a thermoelectric module)

  • 황준;강병하
    • 한국수소및신에너지학회논문집
    • /
    • 제15권4호
    • /
    • pp.341-347
    • /
    • 2004
  • An experimental study has been carried out on cooling perfonnance of a thennoelectric module. This problem is of particular interest in the design of the refrigeration systems using thermoelectric module, such as cosmetic refrigerator, wine cellar and air cooler. The effect of the input voltage and the hot side temperature on the cooling performance is studied in detail. The $\Delta$T, temperature difference between cold side and hot side surface of thermoelectric module, is described in terms of the input voltage and the hot side temperature. It is found that the cooling capacity can be improved by increasing the input voltage and by reducing the heat from the hot side of the thermoelectric module. However, COP is decreased with an increase in the input voltage, since power consumption is also increased. Thus, optimum input voltage can be selected based on cooling capacity and COP.

서지전압에 의한 저압유도전동기의 절연평가 (Insulation Evaluation of Low-voltage Induction Motors by Surge Voltages)

  • 최수연;최재성;박대원;길경석;송재용
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.1892-1896
    • /
    • 2008
  • Inverter-fed induction motors (IFM) are prevalent in traction vehicles. However, the winding insulation of IFM is substantially more stressed than of line-powered motors by surge voltages. Consequently, the winding insulation of IFM should be estimated by surge voltages. Also, the weakness of coil insulation can be detected by the surge voltage test. This paper described the insulation evaluation of induction motors by application of surge voltages. A surge voltage generator with the maximum voltage of 5 kV and the selectable rise-time in ranges of $50\;ns\;{\sim}\;500\;ns$ was fabricated. In the experiment, we applied surge voltages into induction motors with the magnitude and the risetime according to IEEE 522. By the analysis of applied surge voltage and current waveforms, we could find difference between normal and defection windings.

  • PDF

메탈헬라이드 램프의 순시재점등용 이그나이터 개발 (The Ignitor Development for Momentary Restarting of Metal Halide Lamps)

  • 박종연;배수호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 D
    • /
    • pp.2534-2536
    • /
    • 2001
  • The most of metalhalide lamp is what the momentary restarting cannot be realized when the arc tube is in the hot condition. But if the lamp is restarted in the hot conditidn, we must supply the high voltage pulse with 15kv between the both electrodes of lamp. The proposed ignitor has two ignitors. If we connect each ignitor at the both sides, the high voltages of two different frequencies are generated. if so, when the one of the ignitor generates the highest voltage and the other applied generates the lowest voltage. At this time, the widest difference of voltage is applied to electrodes of the lamp. In this way, we can restart the lamp with the voltage 15kv, even if the lamp is in the hot condition.

  • PDF

2-스위치 Buck-Boost 컨버터를 이용한 DC 링크 전압 가변형 인버터 설계 (A Cost Effective DC Link Variable Inverter Using 2-Switch Buck-Boost Converter)

  • 강현수;김준형;이병국;허진
    • 전기학회논문지
    • /
    • 제58권5호
    • /
    • pp.950-959
    • /
    • 2009
  • In this paper, a dc link voltage variable inverter system is proposed, which consists of a two-switch buck-boost converter and a four-switch inverter. In addition, as the current and torque ripples are generated by a voltage difference between back EMF and dc link voltage, these ripples could be reduced according to the controlled dc-link voltage according to the motor speed. The validity of the proposed inverter is verified by informative simulation and experimental results.