• 제목/요약/키워드: Dielectric degradation

검색결과 223건 처리시간 0.022초

기-액 혼합 플라즈마 방전 시스템에서 화학적 활성종의 생성 (Study on the Generation of Chemically Active Species Using Gas-liquid Mixing Plasma Discharging System)

  • 김동석;박영식
    • 한국물환경학회지
    • /
    • 제30권4호
    • /
    • pp.394-402
    • /
    • 2014
  • High-voltage dielectric discharges are an emerging technique in environmental pollutant degradation, which are characterized by the production of hydroxyl radicals as the primary degradation species. The initiation and propagation of the electrical discharges depends on several physical, chemical, and electrical parameters such as 1st and 2nd voltage of power, gas supply, conductivity and pH. These parameters also influence the physical and chemical characteristics of the discharges, including the production of reactive species such as OH, $H_2O_2$ and $O_3$. The experimental results showed that the optimum 1st voltage and oxygen flow rate for RNO (N-Dimethyl-4-nitrosoaniline, indicator of the generation of OH radical) degradation were 160 V (2nd voltage of is 15 kV) and 4 L/min, respectively. As the 2nd voltage (4 kV to 15 kV) was increase, RNO degradation was increased and, generated $H_2O_2$ and $O_3$ concentration were increased. The conductivity of the solution was not influencing the RNO degradation, $H_2O_2$ and $O_3$ generation. The pH effect on RNO degradation was not high. However, the lower pH and the conductivity, the higher $H_2O_2$ and $O_3$ generation were observed.

철도차량 견인전동기의 가속열화수명평가 기술현황 (A technology State of Accelerating Degradation and Life Estimation on the Traction Motor for Railway Rolling Stock)

  • 왕종배;김기준;최영찬
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 제2회 학술대회 논문집 일렉트렛트 및 응용기술전문연구회
    • /
    • pp.25-28
    • /
    • 2000
  • In this paper, the technology for accelerating degradation & life estimation on the traction motor was introduced with the stator form-winding sample coils of the 200 Class insulation system The accelerative degradation was performed in 10 cycles, which were composed of thermal stress, fast rising surge voltage, vibration, water immersion and overvoltage applying. After aging of 10 cycles, condition diagnosis test such as insulation resistance & polarization index, capacitance & dielectric loss and partial discharge properties were investigated in the temperature range of $20{\sim}160^{\circ}C$. Relationship between degradation conditions and diagnosis results were analyzed to find an dominative degradation factor at the end-life point

  • PDF

부분방전 시스템을 이용한 절연 열화에 관한 연구 (A Study on the Dielectric Degradation Using Partial Discharge System)

  • 김성홍;이우상;정재용
    • 전자공학회논문지T
    • /
    • 제35T권1호
    • /
    • pp.1-6
    • /
    • 1998
  • 본 연구는 부분방전 시스템을 이용하여 열화진단을 실시하였다. 열화 분석 방법으로는 위상각 부분방전 펄스진폭 열화시간과 위상각 부분방전 펄스수 열화시간의 양상을 왜도와 첨쇄도로 3차원 분석하여 열화의 정보로 이용하였다. 두번째로는 C (경도), G (무게중심)의 통계적 파라메터를 이용하여 방전의 군소화가 발생하는 시간을 구하여 그 지점으로부터 수명 4예측을 하였다.

  • PDF

유입식 변압기의 열화시간에 따른 절연 열화특성 및 선형회귀법을 이용한 상관관계 분석 (Analysis for Insulating Degradation Characteristics with Aging Time for Oil-filled Transformers and/or Correlation between using Linear Regression Method)

  • 이승민
    • 전기학회논문지
    • /
    • 제59권4호
    • /
    • pp.693-699
    • /
    • 2010
  • General transformer's life is known as paper insulation' life. If a transformer is degraded by these aging factors, it is known that electrical, mechanical and chemical characteristics for transformer's oil-paper are changed. When the kraft paper is aged, the cellulose polymer chains break down into shorter lengths. It causes decrease in both tensile strength and degree of polymerization of paper insulation. The paper breakdown is accompanied by an increase in the content of furanic compounds within the dielectric liquid. In this paper it is aimed at analysis on correlation between aging characteristics for insulating diagnosis of thermally aged paper. For investigating the accelerated aging process of oil-paper samples accelerating aging cell was manufactured for estimating variation of paper insulation during 500 hours at $140^{\circ}C$ temperature. To derive the results, it was performed analysis such as tensile strength(TS), depolymerization(DP), dielectric strength(DS), relative permittivity, water content(WC) and furan compound(FC) for aged paper. Also for analyzing correlation between insulating degradation characteristics, we used linear regression method. As as results of linear regression analysis, there was a close correlation between TS and DP. WC, FC. But dielectric strength was a weak correlation with aging time.

급전 기판의 유전상수 및 두께가 개구면 결합 마이크로스트립 패치 안테나의 특성에 미치는 영향 (Effects of the Dielectric Constant and Thickness of a Feed Substrate on the Characteristics of an Aperture Coupled Microstrip Patch Antenna)

  • 박혜린;구환모;김부균
    • 전자공학회논문지
    • /
    • 제51권7호
    • /
    • pp.49-59
    • /
    • 2014
  • 개구면 결합 마이크로스트립 패치 안테나(aperture coupled microstrip patch antenna; ACMPA)의 급전 기판의 유전상수와 두께가 안테나 대역폭과 방사특성에 미치는 영향에 대하여 연구하였다. 급전 기판의 두께가 같은 여러 가지 유전상수의 급전기판을 가지는 ACMPA의 최적화된 반사손실 대역폭은 방사특성의 저하 없이 급전기판의 유전상수가 감소할수록 대역폭이 증가한다. MMIC(monolithic microwave integrated circuit)와 집적화가 가능한 높은 유전상수(${\epsilon}_r=10$)를 가지는 급전 기판을 사용한 ACMPA의 최적화된 반사손실 대역폭은 방사특성의 저하 없이 급전 기판의 두께가 감소할수록 대역폭이 증가한다. 따라서 ACMPA는 MMIC와 집적화하기에 좋은 구조를 가진 패치 안테나이다.

견인전동기 고정자 코일의 열화특성 연구 (Research of Degradation Properties on Stator Coil of Traction Motor)

  • 장동욱;변윤섭;왕종배;박현준;김길동;한영재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1430-1432
    • /
    • 2001
  • In this paper, 200-class insulation system for form-wound stator coils is designed for form-wound stator coils is designed for AC traction driven with VVVF inverter. Model coils are made to embody all essential elements representing a winding insulation system and structure. Acceleration degradation for model coils is applied exposure to heat(235$^{\circ}C$). In order to investigate the condition of the coils and to determine their insulation reliability, high voltage test and the dielectric properties such as dielectric loss and capacitance are performed. Also, partial discharge measurement is investigated for internal defects.

  • PDF

열 열화한 열전도성 실리콘 고무의 전기특성 (Electric Properties of Thermal Conductive Silicone Rubber due to Thermally Degradation)

  • 이성일
    • 한국전기전자재료학회논문지
    • /
    • 제29권12호
    • /
    • pp.835-840
    • /
    • 2016
  • In this study, the electrostatic capacity and dielectric loss tangent for $20{\mu}m$ thick thermal conductivity silicone rubber which is heated at 80 degrees for 8 hours has been measured at temperature of $30^{\circ}C{\sim}170^{\circ}C$, frequency of 0.1~1 MHz. The results of degradation evaluation by this study are as follows. In low frequency, it found that the electrostatic capacity decreased with increasing temperature. On the other hand, it confirmed that the range of the electrostatic capacity narrowed with increasing frequency. It confirmed that there are the carboxylic acid structure and C-O bonding at range of wave number 1,000cm-1 to 1,300cm-1.

몰드변압기용 에폭시 수지의 열 열화 특성에 관한 연구 (Study on the Thermal Degradation Properties of Epoxy Resin for the Cast Resin Transformer)

  • 남기동;정중일;허창수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1572-1574
    • /
    • 2000
  • In this paper, study on the properties of the thermal degradated epoxy resin which is used in cast resin transformer is performed to investigate the problems of the decreasing insulation characteristics and crack in the cast resin transformer. In the test, contact angle, weight loss, surface resistivity and relative dielectric constant are measured. As the results of the above measurements, the epoxy resin has increased to 150$^{\circ}C$ in the contact angle and surface resistivity but at the above 150$^{\circ}C$ the values have decreased. The relative dielectric constants have increased in the thermal treated samples with the degradation temperature. Consequently, the insulation properties of the epoxy resin which is used in cast resin transformer have increased by the 150$^{\circ}C$ but decreased in the above 150$^{\circ}C$.

  • PDF

산화된풀리에틸렌의 부분방전 특성 (The Partial Discharge Properties of Oxidized Polyethylene)

  • 이현수;한상옥
    • 대한전기학회논문지
    • /
    • 제41권7호
    • /
    • pp.802-808
    • /
    • 1992
  • To investigate degradation procedure and life time of the oxidized PE and the unoxidized PE, alternative voltage is applied to the CIGRE Method-II (CM-II) electrode system, which is loaded artificial void, and measures the distribution of partial discharging generation. From the results, the samples etched by oxidation had wide degradation area of dielectric strength. Furthermore, discharge starting voltage was shifted to low voltage, the discharge generation frequency was high and consequently, the quantity of mean charge becomes small. Also, life time of the oxdized sample is shortened according as the oxidation time is longer.

  • PDF

전경 물체 추출 기법을 이용한 전기트리 영상에서 열화 측정 (Degradation Measurement from Electrical Tree Image Using Foreground Object Extracting Skill)

  • 김형균;정기봉;고석만;오무송;김태성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.270-273
    • /
    • 2001
  • Electrical tree is studied widely by manufacture state of insulating material fare and blazing fire diagnosis system of use in phenomenon of part discharge that happen for main cause of dielectric breakdown of equipment for electric power. Use process that draw tree pattern here measuring above zero to study special quality of this electricity tree, real-time processing by image processing is proposed because reproduction of tree blazing fire process drops and pattern of tree is difficult correct quantification of tree growth by existent visual observation by involution. This research presents general process that need in image processing of tree blazing fire, and that remove various noises that happen in above zero by measuring electrical tree dividing background and complete view in measured above zero taking advantage of specially proposed complete view object abstraction techniques effectively and quantification of tree becomes easy naturally, can apply to dielectric breakdown estimate because can chase growth process of tree.

  • PDF