• 제목/요약/키워드: Dielectric degradation

검색결과 223건 처리시간 0.032초

Effect of dielectric barrier discharge parameters on degradation efficiency of ethyl acetate

  • Deng, Xu;Lu, SiHeng;Zheng, Kun;Yu, ZhiMin
    • 도시과학
    • /
    • 제8권2호
    • /
    • pp.13-18
    • /
    • 2019
  • Using self-made coil dielectric barrier discharge reactor, the removal efficiency of ethyl acetate under simulated experimental parameters such as initial concentration of waste gas, total flow rate, relative humidity and voltage was investigated. The results show that the degradation rate of ethyl acetate increases with the increase of output voltage. When other conditions remain unchanged, the degradation rate decreases with the increase of initial concentration of ethyl acetate; with the increase of total flow rate, the degradation rate of ethyl acetate decreases; with the increase of relative humidity, the degradation rate first increases and then decreases, and when the relative humidity is 64%, the degradation efficiency is the highest.

방사선 열화에 따른 PEEK의 유전특성과 동적 기계적 특성 (Dielectric Analysis and Dynamic Mechanical Analysis of Radiation Degradation of PEEK)

  • 김기엽;강현구;류부형;이청;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.1
    • /
    • pp.485-488
    • /
    • 2003
  • Radiation degradation of Poly(ether ether ketone) (PEEK) has been studied by dielectric analysis and dynamic mechanical analysis. It has been observed that dielectric properties are influenced by radiation degradation of PEEK. For radiation degradation of PEEK, dynamic mechanical properties were insensible.

  • PDF

Design of a Flexible Planar RFID Tag Antenna with Low Performance Degradation from Nearby Target Objects

  • Choo, Jae-Yul;Ryoo, Jeong-Ki;Choo, Ho-Sung
    • Journal of electromagnetic engineering and science
    • /
    • 제11권1호
    • /
    • pp.1-4
    • /
    • 2011
  • In this letter, we propose a novel tag antenna that has low performance degradation with nearby dielectric material. We obtained a stable reading performance and a broad matching bandwidth on nearby dielectric materials by employing a T-matching network with thick line width and capacitively slot-loaded arms. We then built the proposed antenna and measured the tag sensitivity to examine the reading characteristics with nearby dielectric materials. The measured results clearly demonstrate stable tag sensitivity with various nearby dielectric materials, such as foam, acrylic-plastic, glass, and ceramic plates. To more closely observe the antenna characteristics with nearby dielectric materials, we also examined the impedance variation and surface current distribution with respect to the dielectric constant of nearby target objects, which ranged from $1{\times}{\varepsilon}_0$ to $16{\times}{\varepsilon}_0$.

유전체 장벽 방전 플라즈마 반응기를 이용한 페놀 처리 (Phenol Treatment Plasma Reactor of Dielectric Barrier Discharge)

  • 박영식
    • 한국환경과학회지
    • /
    • 제21권4호
    • /
    • pp.479-488
    • /
    • 2012
  • A Dielectric barrier discharge (DBD) plasma is shown in the present investigation to be effective of phenol degradation in the aqueous solutions in batch reactor with continuous air bubbling. Removal of phenol and effects of various parameters on the removal efficiency in the aqueous solution with high-voltage streamer discharge plasma are studied. The effect of 1st voltage (80 ~ 220 V), air flow rate (3 ~ 7 L/min), pH (3 ~ 11), electric conductivity of solution (4.16 ${\mu}S$/cm, deionized water) ~ 16.57 mS/cm (addition of NaCl 10 g/L) and initial phenol concentration (2.5 ~ 20.0 mg/L) were investigated. The observed results showed that phenol degradation was higher in the basic solution than that of the acidic. The optimum values on the 1st voltage and air flow rate for phenol degradation were 140 V and 6 L/min, respectively. It was considered that absorbance variation of $UV_{254}$ of phenol solution can be use as an indirect indicator of change of the non-biodegradable organic compounds within the treated phenol solution. Electric conductivity was not influenced the phenol degradation. To obtain the removal efficiency of phenol and COD of phenol over 97 % (initial phenol concentration, 10.0 mg/L), 80 min and 120 min were need, respectively. Phenol and COD degradation showed a pseudo-first order kinetics.

수처리용 유전체장벽 플라즈마 반응기에 대한 기초 연구 (A Basic Study of Plasma Reactor of Dielectric Barrier Discharge for the Water Treatment)

  • 김동석;박영식
    • 한국환경과학회지
    • /
    • 제20권5호
    • /
    • pp.623-630
    • /
    • 2011
  • This study investigated the degradation of N, N-Dimethyl-4-nitrosoaniline (RNO, indicator of the generation of OH radical) by using dielectric barrier discharge (DBD) plasma. The DBD plasma reactor of this study consisted of a quartz dielectric tube, titanium discharge (inner) and ground (outer) electrode. The effect of shape (rod, spring and pipe) of ground electrode, diameter (9~30 mm) of ground electrode of spring shape and inside diameter (4~13 mm) of quartz tube, electrode diameter (1~4 mm), electrode materials (SUS, Ti, iron, Cu and W), height difference of discharge and ground electrode (1~15.5 cm) and gas flow rate (1~7 L/min) were evaluated. The experimental results showed that shape of ground electrode and materials of ground and discharge electrode were not influenced the RNO degradation. The thinner the diameter of discharge and ground electrode, the higher RNO degradation rate observed. The effect of height gap of discharge between ground electrode on RNO degradation was not high within the experimented value. Among the experimented parameters, inside diameter of quartz tube and gas flow rate were most important parameters which are influenced the decomposition of RNO. Optimum inside diameter of quartz tube and gas flow rate were 7 mm and 4 L/min, respectively.

방사선이 폴리프로필렌의 결정구조에 미치는 영향과 유전특성 (The effects on the crystal structure of Polypropylene exposed Radiation and Its dielectric properties)

  • 강전홍;김한준;유광민;박강식;김종석;한상옥
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.894-896
    • /
    • 2001
  • The Polypropylene films which are made by refinement of its pellet and formed as crystals are exposed to Radiation. As the results, degradation effects were observed in non-crystalline regions. It is thus considered that the effects occur by destroying of lattice binding force by Radiation. The distribution of degradation was increased with irradiation quantities of Radiation and dielectric constant of Polypropylene sheets irradiated Radiation was rapidly increased from above 10 MHz.

  • PDF

22/154kV급 XLPE의 유전특성과 절연열화 (Degradation and Dielectric Properties of 22/154kV XLPE sheets)

  • 이관우;이종복;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.84-87
    • /
    • 2001
  • In this paper, degradation and dielectric properties of XLPE sheets moved from 22/154kV power cables were investigated. At the results of dielectric property of 22kV/154kV XLPE sheet, We earned that $tan{\delta}$ is $7.4{\times}10^{-4}$, $2.15{\times}10^{-4}$ and dielectric constant is 2.3, 2.24. Temperature dependance of $tan{\delta}$ inclined to increasing with temperature and increase of $tan{\delta}$ of 22kV XLPE sheet is higher than it of 154kV XLPE sheet. And increasement of XLPE sheet with water is higher than it without water.

  • PDF

수처리용 다중 유전체 방벽 방전 플라즈마 반응기 개발 (Development of Multi Dielectric Barrier Discharge Plasma Reactor for Water Treatment)

  • 김동석;박영식
    • 한국환경과학회지
    • /
    • 제22권7호
    • /
    • pp.863-871
    • /
    • 2013
  • Dielectric discharges are an emerging technique in environmental pollutant degradation, which that are characterized by the production of hydroxyl radicals as the primary degradation species. For practical application of the plasma reactor, reactor that can handle large amounts of water are needed. Plasma research to date has focused on small-scale water treatment. This study was carried out basic study for scale-up of a single DBD (dielectric barrier discharge) plasma reactor. The degradation of N, N-Dimethyl-4-nitrosoaniline (RNO, indicator of the generation of OH radical) was used as a performance indicator of multi-plasma reactor. The experiments is divided into two parts: design parameters [effect of distance of single plasma module (1~14 cm), arrangement of ground electrode (single and multi), rector number (1~5) and power number (1~5)]; operation parameter [effect of applied voltage (60~220 V), air flow rate (1~5 L/min), electric conductivity of solution ($1.4{\mu}S/cm$, deionized water)~18.8 mS/cm (addition of NaCl 10 g/L) and pH (5~9)]. Considering the electric stability of the plasma reactor, optimum spacing between the single plasma module was 2 cm. Multi discharge electrodes - single ground electrode array was selected. Combination of power 3-plasma module 5 was the optimal combination for maximum RNO degradation. The optimum 1st voltage and air flow rate for RNO degradation were 180 V and 4 L/min, respectively. The pH and conductivity of the solution was not influencing the RNO degradation.

수중 플라즈마 공정을 이용한 Rhodamine B 염료의 제거 (Removal of Rhodamine B Dye Using a Water Plasma Process)

  • 김동석;박영식
    • 한국환경보건학회지
    • /
    • 제37권3호
    • /
    • pp.218-225
    • /
    • 2011
  • Objectives: In this paper, a dielectric barrier discharge (DBD) plasma reactor was investigated for degrading the dye Rhodamine B (RhB) in aqueous solutions. Methods: The DBD plasma reactor system in this study consisted of a plasma component [titanium discharge (inner), ground (outer) electrode and quartz dielectric tube], power source, and gas supply. The effects of various parameters such as first voltage (input power), gas flow rate, second voltage (output power), conductivity and pH were investigated. Results: Experimental results showed that a 99% aqueous solution of 20 mg/l Rhodamine B is decolorized following an eleven minute plasma treatment. When comparing the performance of electrolysis and plasma treatment, the RhB degradation of the plasma process was higher that of the electrolysis. The optimum first voltage and air flow rate were 160 V (voltage of trans is 15 kV) and 3 l/min, respectively. With increased second voltage (4 kV to 15 kV), RhB degradation was increased. The higher the pH and the lower conductivity, the more Rhodamine B degradation was observed. Conclusions: OH radical generation of dielectric plasma process was identified by degradation of N, N-dimethyl-4-nitrosoaniline (RNO, indicator of OH radical generation). It was observed that the effect of UV light, which was generated as streamer discharge, on Rhodamine B degradation was not high. Rhodamine B removal was influenced by real second voltage regardless of initial first and second voltage. The effects of pH and conductivity were not high on the Rhodamine B degradation.

테프론의 가열에 의한 C-V 열화 특성에 관한 연구 (A Study on Properties of C-V Degradation due to Heating in Teflon)

  • 이성일
    • 한국전기전자재료학회논문지
    • /
    • 제27권11호
    • /
    • pp.730-735
    • /
    • 2014
  • In this study, the temperature characteristics of electrostatic capacity and dielectric loss for the sample of Teflon film which is degradated at the $120^{\circ}C{\sim}200^{\circ}C$ temperature range in the oven for 10 hours has been measured in through the applied frequency range of 0.1 kHz~4,800 kHz at temperature of $50^{\circ}C$, $90^{\circ}C$, $130^{\circ}C$, $170^{\circ}C$. Also, in the same conditions, the frequency characteristics of electrostatic capacity and dielectric loss for the sample of Teflon film has been measured in through the applied temperature range of $30^{\circ}C{\sim}70^{\circ}C$ on setting frequency of 0.1 kHz, 1 kHz, 10 kHz, 100 kHz. The results of this study are as follows. When the frequency range of 0.1 kHz~4,800 kHz applied to the sample of Teflon film, the electrostatic capacity has been measured at the temperature of $50^{\circ}C$, $90^{\circ}C$, $130^{\circ}C$, $170^{\circ}C$. Through this measurement, it found that the electrostatic capacity decreased with increasing temperature. Regarding this result, may be it is because the electromagnetic coupling is degraded by thermal degradation. When the sample of Teflon film heated at $280^{\circ}C$ for 10 hours in oven, the dielectric loss has changed from unstable status to stabilizing status with increasing the degradation temperature in the $120^{\circ}C$, $160^{\circ}C$, $200^{\circ}C$ range. In this measurement, the two spectrums of dielectric loss appeared. It considers that this spectrum of dielectric loss appeared in 300 Hz is caused by the molecular motion of the C-F or OH group. Through this study, It found that the electrostatic capacity decreased with increasing frequency and temperature, and there is no change in dielectric loss, although the frequency increases.